Chronic recording and electrochemical performance of Utah microelectrode arrays implanted in rat motor cortex
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Multisite implantable electrode arrays serve as a tool to understand cortical network connectivity and plasticity. Furthermore, they enable electrical stimulation to drive plasticity, study motor/sensory mapping, or provide network input for controlling brain-computer interfaces. Neurobehavioral rodent models are prevalent in studies of motor cortex injury and recovery as well as restoration of auditory/visual cues due to their relatively low cost and ease of training. Therefore, it is important to understand the chronic performance of relevant electrode arrays in rodent models. In this report, we evaluate the chronic recording and electrochemical performance of 16-channel Utah electrode arrays, the current state-of-the-art in pre-/clinical cortical recording and stimulation, in rat motor cortex over a period of 6 mo. The single-unit active electrode yield decreased from 52.8 ± 10.0 ( week 1) to 13.4 ± 5.1% ( week 24). Similarly, the total number of single units recorded on all electrodes across all arrays decreased from 106 to 15 over the same time period. Parallel measurements of electrochemical impedance spectra and cathodic charge storage capacity exhibited significant changes in electrochemical characteristics consistent with development of electrolyte leakage pathways over time. Additionally, measurements of maximum cathodal potential excursion indicated that only a relatively small fraction of electrodes (10–35% at 1 and 24 wk postimplantation) were capable of delivering relevant currents (20 µA at 4 nC/ph) without exceeding negative or positive electrochemical potential limits. In total, our findings suggest mainly abiotic failure modes, including mechanical wire breakage as well as degradation of conducting and insulating substrates. NEW & NOTEWORTHY Multisite implantable electrode arrays serve as a tool to record cortical network activity and enable electrical stimulation to drive plasticity or provide network feedback. The use of rodent models in these fields is prevalent. We evaluated chronic recording and electrochemical performance of 16-channel Utah electrode arrays in rat motor cortex over a period of 6 mo. We primarily observed abiotic failure modes suggestive of mechanical wire breakage and/or degradation of insulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 2×
“This level of multifold increase following implantation is highly consistent with previous observations of in vitro vs. in vivo impedances (Cogan 2008; Mercanzini et al. 2009; Musa et al. 2009; Prasad et al. 2012; Wang et al. 2013) and is attributable to tissue impedance and additional impedance at…”
MethodResultSelf-citationResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 2×
“to be a point of debate (Polikov et al. 2005), there is at least one”
BackgroundSchmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672 · cited 1×
“…including control of brain-computer interfaces (Brandman et al. 2017; Jarosiewicz et al. 2015), restoration of lost sensory function (e.g., hearing, vision; Dobelle et al. 1979; Lowery et al. 2015; Schmidt et al. 1996), and motor/sensory mapping for studies of cortical plasticity (Abe et al. 2015).”
BackgroundFailure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
Jarosiewicz, B., Sarma, A. A., Bacher, D., Masse, N. Y., Simeral, J. D., Sorice, B., Oakley, E. M., Blabe, C., Pandarinath, C., Gilja, V., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac7328 · Cited by 340 · cited 1×
“…developed for chronic intracortical recording and stimulation applications, including control of brain-computer interfaces (Brandman et al. 2017; Jarosiewicz et al. 2015), restoration of lost sensory function (e.g., hearing, vision; Dobelle et al. 1979; Lowery et al. 2015; Schmidt et al. 1996),…”
BackgroundPrasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298 · cited 2×
“in vivo impedances (Cogan 2008; Mercanzini et al. 2009; Musa et al. 2009; Prasad et al. 2012; Wang et al. 2013) and is attributable to tissue impedance and additional impedance at the electrode-electrolyte interface.”
BackgroundRelationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Winslow, B. D., Christensen, M. B., Yang, W.-K., Solzbacher, F., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.050 · Cited by 171 · cited 1×
“…time points typically associated with the onset of astrogliosis or fibrotic encapsulation (2–16 weeks; Karumbaiah et al. 2013; Nolta et al. 2015; Winslow et al. 2010), these data suggest that the impedance decreases between weeks 20 and 24 may be abiotic and associated with an increase in…”
BackgroundBarrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161 · cited 1×
“It is well established that the loss of recording or stimulation function with implantable electrode arrays depends on multiple factors (Barrese et al. 2016).”
Background
Cited by
Sponheim, C., Papadourakis, V., Collinger, J. L., Downey, J., Weiss, J., Pentousi, L., Elliott, K., & Hatsopoulos, N. G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3eaf · Cited by 66
Bullard, A. J., Hutchison, B. C., Lee, J., Chestek, C. A., & Patil, P. G. (2020) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.13069 · Cited by 65
Patel, P. R., Welle, E. J., Letner, J. G., Shen, H., Bullard, A. J., Caldwell, C. M., Vega-Medina, A., Richie, J. M., Thayer, H. E., Patil, P. G., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acab86 · Cited by 49
Rosenfeld, J. V., Wong, Y. T., Yan, E., Szlawski, J., Mohan, A., Clark, J. C., Rosa, M., & Lowery, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9e1c · Cited by 35
Metadata
- Authors
- Black, B. J., Kanneganti, A., Joshi-Imre, A., Rihani, R., Chakraborty, B., Abbott, J., Pancrazio, J. J., & Cogan, S. F.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2018-10-01
- Volume
- 120
- Issue
- 4
- Pages
- 2083-2090
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2883070631
- Cited by
- 62
- References
- 14
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic recording and electrochemical performance of Utah microelectrode arrays implanted in rat motor cortex. https://app.cochat.ai/papers/10.1152/jn.00181.2018
- The paper
- Black, B. J., Kanneganti, A., Joshi-Imre, A., Rihani, R., Chakraborty, B., Abbott, J., Pancrazio, J. J., & Cogan, S. F. (2018). Chronic recording and electrochemical performance of Utah microelectrode arrays implanted in rat motor cortex. Journal of Neurophysiology. https://doi.org/10.1152/jn.00181.2018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.