Brain activity mapping at multiple scales with silicon microprobes containing 1,024 electrodes
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The coordinated activity of neural ensembles across multiple interconnected regions has been challenging to study in the mammalian brain with cellular resolution using conventional recording tools. For instance, neural systems regulating learned behaviors often encompass multiple distinct structures that span the brain. To address this challenge we developed a three-dimensional (3D) silicon microprobe capable of simultaneously measuring extracellular spike and local field potential activity from 1,024 electrodes. The microprobe geometry can be precisely configured during assembly to target virtually any combination of four spatially distinct neuroanatomical planes. Here we report on the operation of such a device built for high-throughput monitoring of neural signals in the orbitofrontal cortex and several nuclei in the basal ganglia. We perform analysis on systems-level dynamics and correlations during periods of conditioned behavioral responding and rest, demonstrating the technology's ability to reveal functional organization at multiple scales in parallel in the mouse brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Complex brain networks: graph theoretical analysis of structural and functional systems
Bullmore, E., & Sporns, O. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2575 · Cited by 11,820
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225 · cited 1×
“Since local field potential (LFP) signals are related to the state of local synaptic 417 inputs (Buzsaki et al. 2012; Einevoll et al. 2013), a coherent signal between spike and LFP 418 activity is thought to indicate an interaction between two recording locations (Buzsaki and 419 Schomburg 2015).”
BackgroundMechanisms of Gamma Oscillations
Buzsáki, G., & Wang, X.-J. (2012) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-062111-150444 · Cited by 2,796
Stimulus-specific neuronal oscillations in orientation columns of cat visual cortex
Gray, C. M., & Singer, W. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.5.1698 · Cited by 2,463
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Intrinsic functional architecture in the anaesthetized monkey brain
Vincent, J. L., Patel, G. H., Fox, M. D., Snyder, A. Z., Baker, J. T., Van Essen, D. C., Zempel, J. M., Snyder, L. H., Corbetta, M., & Raichle, M. E. (2007) · Nature · doi:10.1038/nature05758 · Cited by 1,786
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Modulation of visual responses by behavioral state in mouse visual cortex
Niell, C. M., & Stryker, M. P. (2010) · Neuron · doi:10.1016/j.neuron.2010.01.033 · Cited by 1,483
Neuron-type-specific signals for reward and punishment in the ventral tegmental area
Cohen, J. Y., Haesler, S., Vong, L., Lowell, B. B., & Uchida, N. (2012) · Nature · doi:10.1038/nature10754 · Cited by 1,318
Multiple reward signals in the brain
Schultz, W. (2000) · Nature Reviews Neuroscience · doi:10.1038/35044563 · Cited by 1,303
Cited by
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Neuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings.
Steinmetz, N. A., Aydin, C., Lebedeva, A., Okun, M., Pachitariu, M., Bauza, M., Beau, M., Bhagat, J., Böhm, C., Broux, M., et al. (2021) · Science · doi:10.1126/science.abf4588 · Cited by 1,173
A Fully Automated Approach to Spike Sorting
Chung, J. E., Magland, J. F., Barnett, A. H., Tolosa, V. M., Tooker, A. C., Lee, K. Y., Shah, K. G., Felix, S. H., Frank, L. M., & Greengard, L. F. (2017) · Neuron · doi:10.1016/j.neuron.2017.08.030 · Cited by 490
Challenges and opportunities for large-scale electrophysiology with Neuropixels probes
Steinmetz, N. A., Koch, C., Harris, K. D., & Carandini, M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.009 · Cited by 333
Mesh electronics: a new paradigm for tissue-like brain probes
Hong, G., Yang, X., Zhou, T., & Lieber, C. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.11.007 · Cited by 159
“In comparison, the overall sizes of silicon microelectrode arrays are almost always >4 times larger than a single neuron regardless of channel numbers [7], and microwire-based brain probes become significantly larger than neuron somata with increasing channel numbers, despite subcellular feature size for single-channe…”
Metadata
- Authors
- Shobe, J. L., Claar, L. D., Parhami, S., Bakhurin, K. I., & Masmanidis, S. C.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2015-09
- Volume
- 114
- Issue
- 3
- Pages
- 2043-2052
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2259663018
- Cited by
- 146
- References
- 22
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Brain activity mapping at multiple scales with silicon microprobes containing 1,024 electrodes. https://app.cochat.ai/papers/10.1152/jn.00464.2015
- The paper
- Shobe, J. L., Claar, L. D., Parhami, S., Bakhurin, K. I., & Masmanidis, S. C. (2015). Brain activity mapping at multiple scales with silicon microprobes containing 1,024 electrodes. Journal of Neurophysiology. https://doi.org/10.1152/jn.00464.2015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.