The DOI matches its Crossref record; 73 of the 74 references it cites were found in a registry or an index.
Polytrodes: High-Density Silicon Electrode Arrays for Large-Scale Multiunit Recording
Abstract
We developed a variety of 54-channel high-density silicon electrode arrays (polytrodes) designed to record from large numbers of neurons spanning millimeters of brain. In cat visual cortex, it was possible to make simultaneous recordings from >100 well-isolated neurons. Using standard clustering methods, polytrodes provide a quality of single-unit isolation that surpasses that attainable with tetrodes. Guidelines for successful in vivo recording and precise electrode positioning are described. We also describe a high-bandwidth continuous data-acquisition system designed specifically for polytrodes and an automated impedance meter for testing polytrode site integrity. Despite having smaller interconnect pitches than earlier silicon-based electrodes of this type, these polytrodes have negligible channel crosstalk, comparable reliability, and low site impedances and are capable of making high-fidelity multiunit recordings with minimal tissue damage. The relatively benign nature of planar electrode arrays is evident both histologically and in experiments where the polytrode was repeatedly advanced and retracted hundreds of microns over periods of many hours. It was possible to maintain stable recordings from active neurons adjacent to the polytrode without change in their absolute positions, neurophysiological or receptive field properties.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, neural tissues are normally three-dimensional (3D) structures, and 2D neural probes are limited to recording signals from only planar brain regions4,5.”
From A flexible three-dimensional electrode mesh: An enabling technology for wireless brain–computer interface prostheses (2016) · cites this paper as [5]
Citations
Cites
On the generalized distance in statistics
Mahalanobis, P. C. (1936) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 6,068
Regulation of Synaptic Efficacy by Coincidence of Postsynaptic APs and EPSPs
Markram, H., Lübke, J., Frotscher, M., & Sakmann, B. (1997) · Science · doi:10.1126/science.275.5297.213 · Cited by 3,832
Interneurons of the hippocampus
Freund, T. F., & Buzsáki, G. (1998) · Hippocampus · doi:10.1002/(sici)1098-1063(1996)6:4 · Cited by 3,478
Numerical recipes in FORTRAN: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638a · Cited by 2,500
Dynamics of the Hippocampal Ensemble Code for Space
Wilson, M. A., & McNaughton, B. L. (1993) · Science · doi:10.1126/science.8351520 · Cited by 2,350
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Churchland, P. S., & Sejnowski, T. J. (1992) · doi:10.7551/mitpress/2010.001.0001 · Cited by 1,757
Mitzdorf, U. (1985) · Physiological Reviews · doi:10.1152/physrev.1985.65.1.37 · Cited by 1,690
A Synaptically Controlled, Associative Signal for Hebbian Plasticity in Hippocampal Neurons
Magee, J. C., & Johnston, D. (1997) · Science · doi:10.1126/science.275.5297.209 · Cited by 1,340
High-frequency network oscillation in the hippocampus
Buzsáki, G., Horváth, Z., Urioste, R., Hetke, J. F., & Wise, K. D. (1992) · Science · doi:10.1126/science.1589772 · Cited by 1,223
Self-citation
Research works printed but not linked: 1
- Fromherz P. Neuroelectronic interfacing: semiconductor chips with ion channels, nerve cells, and brain. In: Nanoelectronics and Information Technology, edited by Waser R. Berlin: Wiley-VCH Verlag, 2003, p. 781–810.
Cited by
Sorted by citations
Items 101–200 of 279
Leibig, C., Wächtler, T., & Zeck, G. M. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.06.006 · Cited by 38
Schultz, S. R., Copeland, C. S., Foust, A. J., Quicke, P., & Schuck, R. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2577380 · Cited by 38
Toward Nontransient Silk Bioelectronics: Engineering Silk Fibroin for Bionic Links
Patil, A. C., Xiong, Z., & Thakor, N. V. (2020) · Small Methods · doi:10.1002/smtd.202000274 · Cited by 37
Python for large-scale electrophysiology
Spacek, M. A. (2008) · Frontiers in Neuroinformatics · doi:10.3389/neuro.11.009.2008 · Cited by 37
Self-citationNeural electrodes for brain‐computer interface system: From rigid to soft
Yang, D., Tian, G., Chen, J., Liu, Y., Fatima, E., Qiu, J., Malek, N. A. N. N., & Qi, D. (2025) · BMEMat · doi:10.1002/bmm2.12130 · Cited by 37
How does the presence of neural probes affect extracellular potentials?
Buccino, A. P., Kuchta, M., Jæger, K. H., Ness, T. V., Berthet, P., Mardal, K., Cauwenberghs, G., & Tveito, A. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab03a1 · Cited by 35
Spatial Information Based OSort for Real-Time Spike Sorting Using FPGA
Schäffer, L., Nagy, Z., Kincses, Z., Fiáth, R., & Ulbert, I. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2996281 · Cited by 35
Microfabricated intracortical extracellular matrix-microelectrodes for improving neural interfaces
Shen, W., Das, S., Vitale, F., Richardson, A. G., Ananthakrishnan, A., Struzyna, L. A., Brown, D. P., Song, N., Ramkumar, M., Lucas, T. H., et al. (2018) · Microsystems & Nanoengineering · doi:10.1038/s41378-018-0030-5 · Cited by 37
Accurate action potential inference from a calcium sensor protein through biophysical modeling:Preprint
Greenberg, D. S., Wallace, D. J., Voit, K.-M., Wuertenberger, S., Czubayko, U., Monsees, A., Handa, T., Vogelstein, J. T., Seifert, R., Groemping, Y., et al. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/479055 · Cited by 34
Multichannel Silicon Probes for Awake Hippocampal Recordings in Large Animals
Ulyanova, A. V., Cottone, C., Adam, C. D., Gagnon, K. G., Cullen, D. K., Holtzman, T., Jamieson, B. G., Koch, P. F., Chen, H., Johnson, V. E., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00397 · Cited by 33
Veerabhadrappa, R., Hassan, M. U., Zhang, J., & Bhatti, A. (2020) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2020.00034 · Cited by 33
Compressive Multiplexing of Correlated Signals
Ahmed, A. M., & Romberg, J. (2014) · IEEE Transactions on Information Theory · doi:10.1109/tit.2014.2366459 · Cited by 32
Fiáth, R., Beregszászi, P., Horváth, D., Wittner, L., Aarts, A. A. A., Ruther, P., Neves, H. P., Bokor, H., Acsády, L., & Ulbert, I. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00318.2016 · Cited by 32
Classification of EEG abnormalities in partial epilepsy with simultaneous EEG–fMRI recordings
Pedreira, C., Vaudano, A. E., Thornton, R. C., Chaudhary, U. J., Vulliémoz, S., Laufs, H., Rodionov, R., Carmichael, D. W., Lhatoo, S. D., Guye, M., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.05.009 · Cited by 31
CMOS Neural Probe With 1600 Close-Packed Recording Sites and 32 Analog Output Channels
Herbawi, A. S., Christ, O., Kiessner, L., Mottaghi, S., Hofmann, U., Paul, O., & Ruther, P. (2018) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2018.2872619 · Cited by 30
Fan, X., Song, Y., Ma, Y., Zhang, S., Xiao, G., Yang, L., Xu, H., Zhang, D., & Cai, X. (2016) · Sensors · doi:10.3390/s17010061 · Cited by 30
Allen, B. D., Moore-Kochlacs, C., Bernstein, J. G., Kinney, J. P., Scholvin, J., Seoane, L. F., Chronopoulos, C., Lamantia, C., Kodandaramaiah, S. B., Tegmark, M., et al. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00650.2017 · Cited by 29
Beckers, G. J. L., & Gahr, M. L. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.6045-11.2012 · Cited by 28
Sub 100 nW Volatile Nano-Metal-Oxide Memristor as Synaptic-Like Encoder of Neuronal Spikes
Gupta, I., Serb, A., Khiat, A., Zeitler, R., Vassanelli, S., & Prodromakis, T. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2797939 · Cited by 26
Neural Processing of Short-Term Recurrence in Songbird Vocal Communication
Beckers, G. J. L., & Gahr, M. L. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011129 · Cited by 27
Khurram, A., & Seymour, J. P. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610179 · Cited by 26
Mols, K., Musa, S., Nuttin, B., Lagae, L., & Bonin, V. (2017) · Scientific Reports · doi:10.1038/s41598-017-15121-1 · Cited by 26
CMOS-Based High-Density Silicon Microprobe Array for Electronic Depth Control in Neural Recording
Seidl, K., Herwik, S., Nurcahyo, Y., Torfs, T., Keller, M., Schüettler, M., Neves, H. P., Stieglitz, T., Paul, O., & Ruther, P. (2009) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2009.4805361 · Cited by 25
A multi-shank silk-backed parylene neural probe for reliable chronic recording
Wu, F., Tien, L., Chen, F., Kaplan, D., Berke, J., & Yoon, E. (2013) · 2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII) · doi:10.1109/transducers.2013.6626910 · Cited by 24
Novel four-sided neural probe fabricated by a thermal lamination process of polymer films
Shin, S., Kim, J., Jeong, J., Gwon, T. M., Lee, S., & Kim, S. J. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.12.017 · Cited by 24
Interfacing Neurons with Nanostructured Electrodes Modulates Synaptic Circuit Features
Dominguez, A. L., Rodilla, B. L., Calaresu, I., Arché‐Núñez, A., González‐Mayorga, A., Scaini, D., Pérez, L., Camarero, J., Miranda, R., López‐Dolado, E., et al. (2020) · Advanced Biosystems · doi:10.1002/adbi.202000117 · Cited by 23
Intracranial neuronal ensemble recordings and analysis in epilepsy
Tóth, E., Fabó, D., Entz, L., Ulbert, I., & Erőss, L. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.09.028 · Cited by 23
Spike detection methods for polytrodes and high density microelectrode arrays
Swindale, N. V., & Spacek, M. A. (2014) · Journal of Computational Neuroscience · doi:10.1007/s10827-014-0539-z · Cited by 23
Self-citationGabran, S. R. I., Salam, M. T., Dian, J. A., El-Hayek, Y. H., Velázquez, J. L. P., Genov, R., Carlen, P. L., Salama, M. M. A., & Mansour, R. R. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2322077 · Cited by 23
Neuronal ‘Ensemble’ Recording and the Search for the Cell Assembly: A Personal History
McNaughton, B. L. (2024) · Hippocampus · doi:10.1002/hipo.23669 · Cited by 22
Why not record from every electrode with a CMOS scanning probe?Preprint
Dimitriadis, G., Neto, J. P., Aarts, A. A. A., Andrei, A., Ballini, M., Battaglia, F. P., Calcaterra, L., Chen, S., David, F., Fiáth, R., et al. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/275818 · Cited by 23
Greenspon, C. M., Battell, E. E., Devonshire, I. M., Donaldson, L. F., Chapman, V., & Hathway, G. J. (2018) · The Journal of Physiology · doi:10.1113/jp277036 · Cited by 26
Penetrating multichannel stimulation and recording electrodes in auditory prosthesis research
Anderson, D. J. (2008) · Hearing Research · doi:10.1016/j.heares.2008.01.010 · Cited by 20
Magnitude and behavior of cross-talk effects in multichannel electrophysiology experiments
Nelson, M. J., Valtcheva, S., & Venance, L. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00877.2016 · Cited by 20
Ovsepian, S. V. (2019) · Brain Structure and Function · doi:10.1007/s00429-019-01835-7 · Cited by 22
Characterization of extracellular spike waveforms recorded in wallaby primary visual cortex
Jung, Y. J., Sun, S. H., Almasi, A., Yunzab, M., Hamish Meffin, A., & Ibbotson, M. R. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1244952 · Cited by 19
Active Micro-Nano-Collaborative Bioelectronic Device for Advanced Electrophysiological Recording
Xiang, Y., Shi, K., Li, Y., Xue, J., Tong, Z., Li, H., Li, Z., Teng, C., Fang, J., & Hu, N. (2024) · Nano-Micro Letters · doi:10.1007/s40820-024-01336-1 · Cited by 19
Variability of acute extracellular action potential measurements with multisite silicon probes
Scott, K. M., Du, J., Lester, H. A., & Masmanidis, S. C. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.08.005 · Cited by 19
Sparse sampling: theory, methods and an application in neuroscience
Oñativia, J., & Dragotti, P. L. (2014) · Biological Cybernetics · doi:10.1007/s00422-014-0639-x · Cited by 19
Chauvière, L., Pothof, F., Gansel, K. S., Klon-Lipok, J., Aarts, A. A. A., Holzhammer, T., Paul, O., Singer, W., & Ruther, P. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00464 · Cited by 19
Xu, D., Fang, J., Yadid, M., Zhang, M., Wang, H., Xia, Q., Li, H., Cao, N., Dvir, T., & Hu, N. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114122 · Cited by 19
Fiáth, R., Raducanu, B. C., Musa, S., Andrei, A., López, C. M., Welkenhuysen, M., Ruther, P., Aarts, A. A. A., & Ulbert, I. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.08.020 · Cited by 19
A Taste Bud Organoid-Based Microelectrode Array Biosensor for Taste Sensing
Liu, S., Zhu, P., Tian, Y., Chen, Y., Liu, Y., Wang, M., Chen, W., Du, L., & Wu, C. (2022) · Chemosensors · doi:10.3390/chemosensors10060208 · Cited by 18
Construction of Direction Selectivity through Local Energy Computations in Primary Visual Cortex
Lochmann, T., Blanche, T. J., & Butts, D. A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0058666 · Cited by 18
Self-citationLee, Y., Lin, C.-W., Lin, C.-M., Yeh, S.-R., Chang, Y., & Fang, W. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/2/025014 · Cited by 18
Chronic, Reusable, Multiday Neuropixels Recordings during Free-Moving Operant Behavior
Song, Z., Alpers, A., Warner, K., Iacobucci, F. A., Hoskins, E., Disterhoft, J. F., Voss, J. L., & Widge, A. S. (2024) · eNeuro · doi:10.1523/eneuro.0245-23.2023 · Cited by 17
Extracellular matrix proteins as temporary coating for thin-film neural implants
Ceyssens, F., Deprez, M., Turner, N. J., Kil, D., van Kuyck, K., Welkenhuysen, M., Nuttin, B., Badylak, S. F., & Puers, R. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/14/1/014001 · Cited by 17
Temporal coding carries more stable cortical visual representations than firing rate over time
Zhu, H., He, F., Zolotavin, P., Patel, S. S., Tolias, A. S., Luan, L., & Xie, C. (2025) · Nature Communications · doi:10.1038/s41467-025-62069-2 · Cited by 21
Planar 2D-Array Neural Probe for Deep Brain Stimulation and Recording (DBSR)
Musa, S., Welkenhuysen, M., Huys, R., Eberle, W., van Kuyck, K., Bartic, C., Nuttin, B., & Borghs, G. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-89208-3_581 · Cited by 16
Lee, D., Moon, H. C., Tran, B.-T., Kwon, D.-H., Kim, Y. H., Jung, S., Joo, J. H., & Park, Y. S. (2018) · Experimental Neurobiology · doi:10.5607/en.2018.27.6.593 · Cited by 16
Cellular-scale silicon probes for high-density, precisely localized neurophysiology
Egert, D., Pettibone, J. R., Lemke, S. M., Patel, P. R., Caldwell, C. M., Cai, D., Ganguly, K., Chestek, C. A., & Berke, J. D. (2020) · Journal of Neurophysiology · doi:10.1152/jn.00352.2020 · Cited by 16
Resorbable scaffold based chronic neural electrode arrays
Ceyssens, F., van Kuyck, K., Velde, G. V., Welkenhuysen, M., Stappers, L., Nuttin, B., & Puers, R. (2013) · Biomedical Microdevices · doi:10.1007/s10544-013-9748-x · Cited by 15
Shielded Coaxial Optrode Arrays for Neurophysiology
Naughton, J. R., Connolly, T., Varela, J. A., Lundberg, J. N., Burns, M. J., Chiles, T. C., Christianson, J. P., & Naughton, M. J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00252 · Cited by 15
In Vivo Neural Interfaces—From Small- to Large-Scale Recording
Zhang, B., Deng, C., Cai, C., & Li, X. (2022) · Frontiers in Nanotechnology · doi:10.3389/fnano.2022.885411 · Cited by 15
Scalable Spike Source Localization in Extracellular Recordings using Amortized Variational InferencePreprint
Hurwitz, C., Xu, K., Srivastava, A., Buccino, A. P., & Hennig, M. H. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/656389 · Cited by 15
Hawkes-laguerre reduced rank model for point processes
Pasha, S. A., & Solo, V. (2013) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2013.6638836 · Cited by 14
Biophysics of Extracellular Spikes
Anastassiou, C. A., Buzsáki, G., & Koch, C. (2013) · CRC Press eBooks · doi:10.1201/b14756-4 · Cited by 15
Herbawi, A. S., Kiessner, L., Paul, O., & Ruther, P. (2017) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2017.7993977 · Cited by 14
Riera, J. J., Goto, T., & Kawashima, R. (2014) · Frontiers in Neural Circuits · doi:10.3389/fncir.2014.00004 · Cited by 14
Plugging Electronics Into Minds: Recent Trends and Advances in Neural Interface Microsystems
Kim, M. K., Jeon, H., Lee, H. J., & Je, M. (2019) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2019.2939337 · Cited by 13
Spatiotemporal receptive fields of cells in V1 are optimally shaped for stimulus velocity estimation
Cocci, G., Barbieri, D., & Sarti, A. (2011) · Journal of the Optical Society of America A · doi:10.1364/josaa.29.000130 · Cited by 12
A Visual Guide to Sorting Electrophysiological Recordings Using 'SpikeSorter'
Swindale, N. V., Mitelut, C., Murphy, T. H., & Spacek, M. A. (2017) · Journal of Visualized Experiments · doi:10.3791/55217 · Cited by 12
Self-citationLarge-Scale, High-Resolution Microelectrode Arrays for Interrogation of Neurons and Networks
Obien, M. E. J., & Frey, U. (2019) · Advances in neurobiology · doi:10.1007/978-3-030-11135-9_4 · Cited by 12
Ni, L., Kc, P., Mulvany, E., Zhang, G., & Zhe, J. (2019) · Biomedical Microdevices · doi:10.1007/s10544-019-0364-2 · Cited by 12
Guo, L. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8fc5 · Cited by 11
Multi-electrode array capable of supporting precisely patterned hippocampal neuronal networks
Zhou, T., Perry, S., Berdichevsky, Y., Petryna, S., Fluck, V., & Tatić-Lučić, S. (2015) · Biomedical Microdevices · doi:10.1007/s10544-014-9907-8 · Cited by 11
EEG Recording in Rodents, with a Focus on Epilepsy
del Campo, C. M., Velázquez, J. L. P., & Freire, M. A. C. (2009) · Current Protocols in Neuroscience · doi:10.1002/0471142301.ns0624s49 · Cited by 11
Depth recording capabilities of planar high-density microelectrode arrays
Frey, U., Egert, U., Jäckel, D., Šedivý, J., Ballini, M., Livi, P., Faraci, F. D., Heer, F., Hafizovic, S., Roscic, B., et al. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109270 · Cited by 11
Improving Detection Accuracy of Memristor-Based Bio-Signal Sensing Platform
Gupta, I., Serb, A., Khiat, A., & Prodromakis, T. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2580499 · Cited by 10
Long-term in-vivo recording performance of flexible penetrating microelectrode arrays
Jang, J., Kang, Y. N., Seo, H. W., Kim, B., Choe, H. K., Park, S. H., Lee, M., & Kim, S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3656 · Cited by 10
Multiscale imaging informs translational mouse modeling of neurological disease
Wang, Y., LeDue, J. M., & Murphy, T. H. (2022) · Neuron · doi:10.1016/j.neuron.2022.09.006 · Cited by 13
CMOS-Based High-Density Microelectrode Arrays: Technology and Applications
Obien, M. E. J., Gong, W., Frey, U., & Bakkum, D. J. (2017) · Series in bioengineering · doi:10.1007/978-981-10-3957-7_1 · Cited by 10
Juxtacellular Labeling and Chemical Phenotyping of Extracellularly Recorded Neurons In Vivo
Toney, G. M., & Daws, L. C. (2006) · Humana Press eBooks · doi:10.1385/1-59745-095-2:127 · Cited by 10
Kernel Analysis for Estimating the Connectivity of a Network with Event Sequences
Tezuka, T., & Claramunt, C. (2016) · Journal of Artificial Intelligence and Soft Computing Research · doi:10.1515/jaiscr-2017-0002 · Cited by 9
Xu, X., Tian, Y., Wang, G., & Tian, X. (2014) · Behavioural Brain Research · doi:10.1016/j.bbr.2014.05.034 · Cited by 9
Gabran, S. R. I., Salam, M. T., Dian, J. A., El-Hayek, Y. H., Velázquez, J. L. P., Genov, R., Carlen, P. L., Salama, M. M. A., & Mansour, R. R. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2279403 · Cited by 9
Compressive multiplexers for correlated signals
Ahmed, A. M., & Romberg, J. (2012) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/acssc.2012.6489159 · Cited by 9
High-density optrodes for multi-scale electrophysiology and optogenetic stimulation
Chamanzar, M., Borysov, M., Maharbiz, M. M., & Blanche, T. J. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945199 · Cited by 9
Self-citationRobotic multi-probe single-actuator inchworm neural microdrive
Smith, R. D., Kolb, I., Tanaka, S., Lee, A. K., Harris, T. D., & Barbic, M. (2022) · eLife · doi:10.7554/elife.71876 · Cited by 9
Hawkes-Laguerre dynamic index models for point processes
Pasha, S. A., & Solo, V. (2013) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2013.6761003 · Cited by 8
Lee, Y., Yeh, S., Chang, Y., & Fang, W. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.037 · Cited by 8
Matteucci, G., Riggi, M., & Zoccolan, D. (2020) · Journal of Neurophysiology · doi:10.1152/jn.00033.2020 · Cited by 8
Verification of multichannel electrode array integrity by use of cross-channel correlations
Swindale, N. V., & Spacek, M. A. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.02.009 · Cited by 8
Self-citationA Novel and Simple Spike Sorting Implementation
Petrantonakis, P. C., & Poirazi, P. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2640858 · Cited by 8
What can neuronal populations tell us about cognition?
Arandia-Romero, I., Nogueira, R., Mochol, G., & Moreno‐Bote, R. (2017) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.07.008 · Cited by 8
Localizing neuronal somata from Multi-Electrode Array in-vivo recordings using deep learning
Buccino, A. P., Ness, T. V., Einevoll, G. T., Cauwenberghs, G., & Hafliger, P. D. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036988 · Cited by 7
Voltage distributions in extracellular brain recordings
Swindale, N. V., Rowat, P. F., Krause, M. R., Spacek, M. A., & Mitelut, C. (2021) · Journal of Neurophysiology · doi:10.1152/jn.00633.2020 · Cited by 7
Self-citationFerreira‐Fernandes, E., Laranjo, M., Reis, T., Canijo, B., Ferreira, P. A., Martins, P. F., Vilarinho, J. P. G., Tavakoli, M., Kunicki, C., & Peça, J. (2023) · Frontiers in Neural Circuits · doi:10.3389/fncir.2023.1293620 · Cited by 7
Rogers, N., Thunemann, M., Devor, A., & Gilja, V. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00763 · Cited by 7
Topology identification of dynamic point process networks
Pasha, S. A., & Solo, V. (2014) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2014.6853621 · Cited by 7
Müller, J., Ballini, M., Livi, P., Chen, Y., Shadmani, A., Frey, U., Jones, I. L., Michele, F., Radivojević, M., Bakkum, D. J., et al. (2013) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2013.6626873 · Cited by 7
Sorelli, M., Meo, D. D., Bradley, S., Cheli, F., Ramazzotti, J., Caria, F. F., Perego, L., Destrieux, C., Hof, P. R., Pavone, F. S., et al. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121581 · Cited by 6
Validation of a novel three-dimensional electrode array within auditory cortex
Langhals, N. B., & Kipke, D. R. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333958 · Cited by 6
Scalable, Modular Three-Dimensional Silicon Microelectrode Assembly via Electroless Plating
Scholvin, J., Zorzos, A. N., Kinney, J. P., Bernstein, J., Moore-Kochlacs, C., Kopell, N., Fonstad, C. G., & Boyden, E. S. (2018) · Micromachines · doi:10.3390/mi9090436 · Cited by 6
Enabling single cell electrical stimulation and response recording via a microfluidic platform
Ni, L., Kc, P., Zhang, G., & Zhe, J. (2019) · Biomicrofluidics · doi:10.1063/1.5128884 · Cited by 6
Capturing the Electrical Activity of all Cortical Neurons: Are Solutions Within Reach?
Kaszás, A., Meszéna, D., Fiáth, R., Slézia, A., Ulbert, I., & Katona, G. (2025) · Advanced Science · doi:10.1002/advs.202506225 · Cited by 5
Scaling models for microfabricated in vivo neural recording technologies
Scholvin, J., Fonstad, C. G., & Boyden, E. S. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008321 · Cited by 5
Robust Discovery of Temporal Structure in Multi-neuron Recordings Using Hopfield Networks
Hillar, C. J., & Effenberger, F. (2015) · Procedia Computer Science · doi:10.1016/j.procs.2015.07.313 · Cited by 5
Rácz, R., Köllő, M., Racz, G., Bulz, C., Ackels, T., Warner, T. P. A., Wray, W., Kiskin, N. I., Chen, C., Ye, Z., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac514f · Cited by 5
Tran, H., Ranta, R., Cam, S. L., & Louis-Dorr, V. (2020) · Journal of Computational Neuroscience · doi:10.1007/s10827-019-00735-3 · Cited by 5
Metadata
- Authors
- Blanche, T. J., Spacek, M. A., Hetke, J. F., & Swindale, N. V.
- Affiliations
- University of British Columbia (CA)
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2005-05
- Volume
- 93
- Issue
- 5
- Pages
- 2987-3000
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2141361751
- Cited by
- 282
- References
- 74
- Citations by year
- 2026: 2 · 2025: 11 · 2024: 6 · 2023: 10 · 2022: 10 · 2021: 12 · 2020: 14 · 2019: 23 · 2018: 18 · 2017: 18 · 2016: 27 · 2015: 20 · 2014: 18 · 2013: 19 · 2012: 11
- FWCI
- 1.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5p41rr009754-09)
- National Center for Research Resources (P41-RR09754)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- multi-unit recording, cat visual cortex, electrode placement, impedance measurement, crosstalk, planar electrodes, tetrodes, receptive fields
- MeSH terms
- Action Potentials, Animals, Brain Mapping, Carbocyanines, Cats, Computer Simulation, Densitometry, Electric Conductivity, Electric Stimulation, Electrodes, Implanted, Electrophysiology, Evoked Potentials, Microelectrodes, Neurons, Online Systems, Research Design, Silicon, Time, Visual Cortex, Electric Impedance, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review