The DOI matches its Crossref record; 73 of the 74 references it cites were found in a registry or an index.
Polytrodes: High-Density Silicon Electrode Arrays for Large-Scale Multiunit Recording
Abstract
We developed a variety of 54-channel high-density silicon electrode arrays (polytrodes) designed to record from large numbers of neurons spanning millimeters of brain. In cat visual cortex, it was possible to make simultaneous recordings from >100 well-isolated neurons. Using standard clustering methods, polytrodes provide a quality of single-unit isolation that surpasses that attainable with tetrodes. Guidelines for successful in vivo recording and precise electrode positioning are described. We also describe a high-bandwidth continuous data-acquisition system designed specifically for polytrodes and an automated impedance meter for testing polytrode site integrity. Despite having smaller interconnect pitches than earlier silicon-based electrodes of this type, these polytrodes have negligible channel crosstalk, comparable reliability, and low site impedances and are capable of making high-fidelity multiunit recordings with minimal tissue damage. The relatively benign nature of planar electrode arrays is evident both histologically and in experiments where the polytrode was repeatedly advanced and retracted hundreds of microns over periods of many hours. It was possible to maintain stable recordings from active neurons adjacent to the polytrode without change in their absolute positions, neurophysiological or receptive field properties.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, neural tissues are normally three-dimensional (3D) structures, and 2D neural probes are limited to recording signals from only planar brain regions4,5.”
From A flexible three-dimensional electrode mesh: An enabling technology for wireless brain–computer interface prostheses (2016) · cites this paper as [5]
Citations
Cites
On the generalized distance in statistics
Mahalanobis, P. C. (1936) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 6,068
Regulation of Synaptic Efficacy by Coincidence of Postsynaptic APs and EPSPs
Markram, H., Lübke, J., Frotscher, M., & Sakmann, B. (1997) · Science · doi:10.1126/science.275.5297.213 · Cited by 3,832
Interneurons of the hippocampus
Freund, T. F., & Buzsáki, G. (1998) · Hippocampus · doi:10.1002/(sici)1098-1063(1996)6:4 · Cited by 3,478
Numerical recipes in FORTRAN: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638a · Cited by 2,500
Dynamics of the Hippocampal Ensemble Code for Space
Wilson, M. A., & McNaughton, B. L. (1993) · Science · doi:10.1126/science.8351520 · Cited by 2,350
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Churchland, P. S., & Sejnowski, T. J. (1992) · doi:10.7551/mitpress/2010.001.0001 · Cited by 1,757
Mitzdorf, U. (1985) · Physiological Reviews · doi:10.1152/physrev.1985.65.1.37 · Cited by 1,690
A Synaptically Controlled, Associative Signal for Hebbian Plasticity in Hippocampal Neurons
Magee, J. C., & Johnston, D. (1997) · Science · doi:10.1126/science.275.5297.209 · Cited by 1,340
High-frequency network oscillation in the hippocampus
Buzsáki, G., Horváth, Z., Urioste, R., Hetke, J. F., & Wise, K. D. (1992) · Science · doi:10.1126/science.1589772 · Cited by 1,223
Self-citationHarris, K. D., Henze, D. A., Csicsvari, J. L., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,153
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942
Barthó, P., Hirase, H., Monconduit, L., Zugaro, M., Harris, K. D., & Buzsáki, G. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01170.2003 · Cited by 912
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Gray, C. M., Maldonado, P., Wilson, M., & McNaughton, B. L. (1995) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00085-2 · Cited by 746
The two-dimensional spectral structure of simple receptive fields in cat striate cortex
Jones, J. P., Stepnoski, A., & Palmer, L. A. (1987) · Journal of Neurophysiology · doi:10.1152/jn.1987.58.6.1212 · Cited by 735
The Neural Basis of Perceptual Learning
Gilbert, C. D., Sigman, M., & Crist, R. E. (2001) · Neuron · doi:10.1016/s0896-6273(01)00424-x · Cited by 715
Nicholson, C., & Freeman, J. A. (1975) · Journal of Neurophysiology · doi:10.1152/jn.1975.38.2.356 · Cited by 699
The two-dimensional spatial structure of simple receptive fields in cat striate cortex
Jones, J. P., & Palmer, L. A. (1987) · Journal of Neurophysiology · doi:10.1152/jn.1987.58.6.1187 · Cited by 676
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Active Properties of Neuronal Dendrites
Johnston, D., Magee, J. C., Colbert, C. M., & Christie, B. R. (1996) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.19.030196.001121 · Cited by 608
McNaughton, B. L., O'Keefe, J. M., & Barnes, C. A. (1983) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(83)90097-3 · Cited by 580
In vivo studies of polypyrrole/peptide coated neural probes
Cui, X. T. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00415-5 · Cited by 505
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 484
Self-citationNowak, L. G., Azouz, R., Sanchez-Vives, M. V., Gray, C. M., & McCormick, D. A. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00580.2002 · Cited by 443
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Spatial Relationships among Three Columnar Systems in Cat Area 17
Hübener, M., Shoham, D., Grinvald, A., & Bonhoeffer, T. (1997) · Journal of Neuroscience · doi:10.1523/jneurosci.17-23-09270.1997 · Cited by 372
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 372
Drake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 364
Kandel, A., & Buzsáki, G. (1997) · Journal of Neuroscience · doi:10.1523/jneurosci.17-17-06783.1997 · Cited by 357
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Microfabrication Techniques for Integrated Sensors and Microsystems
Wise, K. D., & Najafi, K. (1991) · Science · doi:10.1126/science.1962192 · Cited by 309
A high-yield IC-compatible multichannel recording array
Najafi, K., Wise, K. D., & Mochizuki, T. (1985) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1985.22102 · Cited by 303
The identification of single units in central visual pathways
Bishop, P. O., Burke, W. J., & Davis, R. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006942 · Cited by 299
A multichannel neural probe for selective chemical delivery at the cellular level
Chen, J., Wise, K. D., Hetke, J. F., & Bledsoe, S. C. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605435 · Cited by 285
Self-citationFunctional connectivity between simple cells and complex cells in cat striate cortex
Alonso, J.-M., & Martinez, L. M. (1998) · Nature Neuroscience · doi:10.1038/1609 · Cited by 278
Chronic neural stimulation with thin-film, iridium oxide electrodes
Weiland, J. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846685 · Cited by 265
Stimulus Timing-Dependent Plasticity in Cortical Processing of Orientation
Yao, H., & Dan, Y. (2001) · Neuron · doi:10.1016/s0896-6273(01)00460-3 · Cited by 251
Mitzdorf, U., & Singer, W. (1978) · Experimental Brain Research · doi:10.1007/bf00235560 · Cited by 250
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Anderson, D. J., Najafi, K., Tanghe, S., Evans, D. A., Levy, K., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32101 · Cited by 229
Self-citationSingle-unit neural recording with active microelectrode arrays
Bai, Q., & Wise, K. D. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.936367 · Cited by 214
Orientation Selectivity in Pinwheel Centers in Cat Striate Cortex
Maldonado, P., Gödecke, I., Gray, C. M., & Bonhoeffer, T. (1997) · Science · doi:10.1126/science.276.5318.1551 · Cited by 209
Rousche, P. J., & Normann, R. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750552 · Cited by 187
A 32-site neural recording probe fabricated by DRIE of SOI substrates
Peter Norlin, A., Kindlundh, M., Mouroux, A., Yoshida, K., & Hofmann, U. (2002) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/12/4/312 · Cited by 184
Auditory Cortical Images of Cochlear-Implant Stimuli: Dependence on Electrode Configuration
Bierer, J. A., & Middlebrooks, J. C. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00212.2001 · Cited by 177
Functionally distinct inhibitory neurons at the first stage of visual cortical processing
Hirsch, J. A., Martinez, L. M., Pillai, C., Alonso, J.-M., Wang, Q., & Sommer, F. T. (2003) · Nature Neuroscience · doi:10.1038/nn1152 · Cited by 176
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Self-citationVornov, J. J., Tasker, R. C., & Coyle, J. T. (1991) · Experimental Neurology · doi:10.1016/0014-4886(91)90079-r · Cited by 172
Scaling limitations of silicon multichannel recording probes
Najafi, K., Ji, J., & Wise, K. D. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43605 · Cited by 165
Kovacs, G. T. A., Storment, C. W., Halks-Miller, M., Belczynski, C. R., Santina, C. C. D., Lewis, E. R., & Maluf, N. I. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293244 · Cited by 161
Somadendritic Backpropagation of Action Potentials in Cortical Pyramidal Cells of the Awake Rat
Buzsáki, G., & Kandel, A. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.3.1587 · Cited by 157
Temporal Specificity in the Cortical Plasticity of Visual Space Representation
Fu, Y.-X., Djupsund, K., Gao, H., Hayden, B. Y., Shen, K., & Dan, Y. (2002) · Science · doi:10.1126/science.1070521 · Cited by 155
ELECTRIC POTENTIALS OCCURRING AROUND A NEURONE DURING ITS ANTIDROMIC ACTIVATION
Fatt, P. (1957) · Journal of Neurophysiology · doi:10.1152/jn.1957.20.1.27 · Cited by 148
The interpretation of the extracellular response of single lateral geniculate cells
Bishop, P. O., Burke, W. J., & Davis, R. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006944 · Cited by 147
Strength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146
Self-citationMarking microelectrode penetrations with fluorescent dyes
DiCarlo, J. J., Lane, J. W., Hsiao, S. S., & Johnson, K. O. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00113-1 · Cited by 141
Kewley, D. T., Hills, M. D., Borkholder, D. A., Opris, I. E., Maluf, N. I., Storment, C. W., Bower, J. M., & Kovacs, G. T. A. (1997) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80221-x · Cited by 120
A micromachined silicon depth probe for multichannel neural recording
Yoon, T. H., Hwang, E. J., Shin, D. Y., Park, S. I., Oh, S., Jung, S. C., Shin, H. C., & Kim, S. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.855936 · Cited by 110
Tetrode technology: advances in implantable hardware, neuroimaging, and data analysis techniques
Jog, M., Connolly, C. I., Kubota, Y., Iyengar, D. R., Garrido, L., Harlan, R., & Graybiel, A. M. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00092-4 · Cited by 109
Chronic recording of regenerating viiith nerve axons with a sieve electrode
Mensinger, A. F., Anderson, D. J., Buchko, C. J., Johnson, M. A., Martin, D. C., Tresco, P. A., Silver, R. B., & Highstein, S. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.611 · Cited by 76
What Is the Other 85 Percent of V1 Doing?
Olshausen, B. A., & Field, D. J. (2006) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195148220.003.0010 · Cited by 66
Surgical Implantation and Biocompatibility of Central Nervous System Auditory Prostheses
Niparko, J. K., Altschuler, R. A., Wiler, J. A., Xue, X., & Anderson, D. J. (1989) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348948909801209 · Cited by 62
Receptive field and orientation scatter studied by tetrode recordings in cat area 17
Hetherington, P. A., & Swindale, N. V. (1999) · Visual Neuroscience · doi:10.1017/s0952523899164046 · Cited by 62
Self-citationTakahashi, K., & Matsuo, T. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)87009-2 · Cited by 47
Characterization of Implantable Microfabricated Fluid Delivery Devices
Rathnasingham, R., Kipke, D. R., Bledsoe, S. C., & McLaren, J. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820311 · Cited by 47
Maldonado, P., & Gray, C. M. (1996) · Visual Neuroscience · doi:10.1017/s095252380000818x · Cited by 42
What is the other 85% of V1 doing?
Olshausen, B. A., & Field, D. J. (2004) · Cited by 42
Viewing and doing: similar cortical mechanisms for perceptual and motor learning
Paz, R., Wise, S. P., & Vaadia, E. (2004) · Trends in Neurosciences · doi:10.1016/j.tins.2004.04.013 · Cited by 39
An Evaluation of Photoengraved Microelectrodes for Extracellular Single-Unit Recording
Starr, A., Wise, K. D., & Csongradi, J. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324194 · Cited by 34
Silicon-based microelectrodes for neurophysiology, micromachined from silicon-on-insulator wafers
Ensell, G., Banks, D., Richards, P. R., Balachandran, W., & Ewins, D. J. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344773 · Cited by 25
Dipole characteristics of pyramidal cell activity in cat postcruciate cortex.
Rosenthal, F., Woodbury, J. W., & Patton, H. D. (1966) · Journal of Neurophysiology · doi:10.1152/jn.1966.29.4.612 · Cited by 24
Zhu, Z. (2002) · Cerebral Cortex · doi:10.1093/cercor/12.6.585 · Cited by 10
A micromachined silicon multielectrode for multiunit recording
Spence, A. J., Hoy, R. R., & Isaacson, M. S. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00075-x · Cited by 10
Research works printed but not linked: 1
- Fromherz P. Neuroelectronic interfacing: semiconductor chips with ion channels, nerve cells, and brain. In: Nanoelectronics and Information Technology, edited by Waser R. Berlin: Wiley-VCH Verlag, 2003, p. 781–810.
Cited by
Sorted by citations
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Extracting information from neuronal populations: information theory and decoding approaches
Quiroga, R. Q., & Panzeri, S. (2009) · Nature reviews. Neuroscience · doi:10.1038/nrn2578 · Cited by 827
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
Activation of specific interneurons improves V1 feature selectivity and visual perception
Lee, S.-H., Kwan, A. C., Zhang, S., Phoumthipphavong, V., Flannery, J. G., Masmanidis, S. C., Taniguchi, H., Huang, Z. J., Zhang, F., Boyden, E. S., et al. (2012) · Nature · doi:10.1038/nature11312 · Cited by 593
How advances in neural recording affect data analysis
Stevenson, I. H., & Kording, K. P. (2011) · Nature Neuroscience · doi:10.1038/nn.2731 · Cited by 590
Metadata
- Authors
- Blanche, T. J., Spacek, M. A., Hetke, J. F., & Swindale, N. V.
- Affiliations
- University of British Columbia (CA)
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2005-05
- Volume
- 93
- Issue
- 5
- Pages
- 2987-3000
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2141361751
- Cited by
- 282
- References
- 74
- Citations by year
- 2026: 2 · 2025: 11 · 2024: 6 · 2023: 10 · 2022: 10 · 2021: 12 · 2020: 14 · 2019: 23 · 2018: 18 · 2017: 18 · 2016: 27 · 2015: 20 · 2014: 18 · 2013: 19 · 2012: 11
- FWCI
- 1.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5p41rr009754-09)
- National Center for Research Resources (P41-RR09754)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- multi-unit recording, cat visual cortex, electrode placement, impedance measurement, crosstalk, planar electrodes, tetrodes, receptive fields
- MeSH terms
- Action Potentials, Animals, Brain Mapping, Carbocyanines, Cats, Computer Simulation, Densitometry, Electric Conductivity, Electric Stimulation, Electrodes, Implanted, Electrophysiology, Evoked Potentials, Microelectrodes, Neurons, Online Systems, Research Design, Silicon, Time, Visual Cortex, Electric Impedance, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review