Multijoint Muscle Regulation Mechanisms Examined by Measured Human Arm Stiffness and EMG Signals
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Multijoint muscle regulation mechanisms examined by measured human arm stiffness and EMG signals. Stiffness properties of the musculo-skeletal system can be controlled by regulating muscle activation and neural feedback gain. To understand the regulation of multijoint stiffness, we examined the relationship between human arm joint stiffness and muscle activation during static force control in the horizontal plane by means of surface electromyographic (EMG) studies. Subjects were asked to produce a specified force in a specified direction without cocontraction or they were asked to keep different cocontractions while producing or not producing an external force. The stiffness components of shoulder, elbow, and their cross-term and the EMG of six related muscles were measured during the tasks. Assuming that the EMG reflects the corresponding muscle stiffness, the joint stiffness was predicted from the EMG by using a two-link six-muscle arm model and a constrained least-square-error regression method. Using the parameters estimated in this regression, single-joint stiffness (diagonal terms of the joint-stiffness matrix) was decomposed successfully into biarticular and monoarticular muscle components. Although biarticular muscles act on both shoulder and elbow, they were found to covary strongly with elbow monoarticular muscles. The preferred force directions of biarticular muscles were biased to the directions of elbow monoarticular muscles. Namely, the elbow joint is regulated by the simultaneous activation of monoarticular and biarticular muscles, whereas the shoulder joint is regulated dominantly by monoarticular muscles. These results suggest that biarticular muscles are innervated mainly to control the elbow joint during static force-regulation tasks. In addition, muscle regulation mechanisms for static force control tasks were found to be quite different from those during movements previously reported. The elbow single-joint stiffness was always higher than cross-joint stiffness (off-diagonal terms of the matrix) in static tasks while elbow single-joint stiffness is reported to be sometimes as small as cross-joint stiffness during movement. That is, during movements, the elbow monoarticular muscles were occasionally not activated when biarticular muscles were activated. In static tasks, however, monoarticular muscle components in single-joint stiffness were increased considerably whenever biarticular muscle components in single- and cross-joint stiffness increased. These observations suggest that biarticular muscles are not simply coupled with the innervation of elbow monoarticular muscles but also are regulated independently according to the required task. During static force-regulation tasks, covariation between biarticular and elbow monoarticular muscles may be required to increase stability and/or controllability or to distribute effort among the appropriate muscles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural, mechanical, and geometric factors subserving arm posture in humans
Mussa-Ivaldi, F., Hogan, N., & Bizzi, E. (1985) · The Journal of Neuroscience · doi:10.1523/jneurosci.05-10-02732.1985 · Cited by 1,158
The mechanics of multi-joint posture and movement control
Hogan, N. (1985) · Biological Cybernetics · doi:10.1007/bf00355754 · Cited by 978
The sensitivity of muscle spindle afferents to small sinusoidal changes of length
Matthews, P. B. C., & Stein, R. B. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008719 · Cited by 743 · cited 1×
“Muscle tensionT can be determined from muscle stiffnessS and the stretch length of each muscle (L0 2 L ) as follows.”
BackgroundSystem identification of human joint dynamics.
Kearney, R. E., & Hunter, I. W. (1990) · PubMed · Cited by 497
Human hand impedance characteristics during maintained posture
Tsuji, T., Morasso, P. G., Goto, K., & Ito, K. (1995) · Biological Cybernetics · doi:10.1007/bf00199890 · Cited by 469
Equilibrium-Point Control Hypothesis Examined by Measured Arm Stiffness During Multijoint Movement
Gomi, H., & Kawato, M. (1996) · Science · doi:10.1126/science.272.5258.117 · Cited by 463
Self-citationHuman arm stiffness and equilibrium-point trajectory during multi-joint movement
Gomi, H., & Kawato, M. (1997) · Biological Cybernetics · doi:10.1007/s004220050329 · Cited by 394
Self-citationCoordination and inhomogeneous activation of human arm muscles during isometric torques
van Zuylen, E. J., Gielen, C. C., & Denier van der Gon, J. J. (1988) · Journal of Neurophysiology · doi:10.1152/jn.1988.60.5.1523 · Cited by 393 · cited 1×
“The deterioration in estimation accuracy compared with the first data group might be ascribed to the difference in moment arms among the postures (van Zuylen et al. 1988).”
Hill-Based Muscle Models: A Systems Engineering Perspective
Winters, J. M. (1990) · Multiple Muscle Systems · doi:10.1007/978-1-4613-9030-5_5 · Cited by 386 · cited 2×
“For different postures, they are also constant if the moment arm can be assumed to be constant (Winters 1990).”
BackgroundCharacteristics of synergic relations during isometric contractions of human elbow muscles
Buchanan, T. S., Almdale, D. P., Lewis, J. L., & Rymer, W. Z. (1986) · Journal of Neurophysiology · doi:10.1152/jn.1986.56.5.1225 · Cited by 356
Cited by
Role of Cocontraction in Arm Movement Accuracy
Gribble, P. L., Mullin, L. I., Cothros, N., & Mattar, A. (2003) · Journal of Neurophysiology · doi:10.1152/jn.01020.2002 · Cited by 660
An EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531
Osu, R., Franklin, D. W., Kato, H., Gomi, H., Domen, K., Yoshioka, T., & Kawato, M. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.2.991 · Cited by 380
Self-citationGomi, H., & Osu, R. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-21-08965.1998 · Cited by 352
Self-citationAdaptive Impedance Control for an Upper Limb Robotic Exoskeleton Using Biological Signals
Li, Z., Huang, Z., He, W., & Su, C.-Y. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2538741 · Cited by 323
Santello, M., Bianchi, M., Gabiccini, M., Ricciardi, E., Salvietti, G., Prattichizzo, D., Ernst, M., Moscatelli, A., Jörntell, H., Kappers, A. M. L., et al. (2016) · Physics of Life Reviews · doi:10.1016/j.plrev.2016.02.001 · Cited by 307
Tele-impedance: Teleoperation with impedance regulation using a body–machine interface
Ajoudani, A., Tsagarakis, N., & Bicchi, A. (2012) · The International Journal of Robotics Research · doi:10.1177/0278364912464668 · Cited by 276
Yang, C., Zeng, C., Liang, P., Li, Z., Li, R., & Su, C.-Y. (2018) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2017.2743000 · Cited by 224
“Stiffness can be estimated using mechanical perturbation method [33], which is a useful way to identify the features of human arm stiffness [34].”
Loeb, G. E. (2012) · Biological Cybernetics · doi:10.1007/s00422-012-0514-6 · Cited by 203
Cheng, E. J., Brown, I. E., & Loeb, G. E. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00258-2 · Cited by 197
“For example, studies of joint stiffness and static and dynamic muscle function based on optimization criteria are often validated solely with electromyograms (EMG; e.g. Kaufman et al., 1991; van der Helm, 1994; Osu and Gomi, 1999); with a musculoskeletal model, force and impedance could be predicted from EMG and compa…”
ResultFranklin, D. W., Burdet, E., Osu, R., Kawato, M., & Milner, T. E. (2003) · Experimental Brain Research · doi:10.1007/s00221-003-1443-3 · Cited by 189
“The presence of the elbow torque term in the expression for shoulder stiffness reflects the contribution of the biarticular muscles which have been shown to be activated primarily to produce elbow torque (Buchanan et al. 1986; Flanders and Soechting 1990; Gomi and Osu 1998; Osu and Gomi 1999; Wadman et al. 1980).”
BackgroundSelf-citationAn sEMG-Based Human–Robot Interface for Robotic Hands Using Machine Learning and Synergies
Meattini, R., Benatti, S., Scarcia, U., De Gregorio, D., Benini, L., & Melchiorri, C. (2018) · IEEE Transactions on Components, Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2018.2799987 · Cited by 115
Pang, M., Guo, S., Huang, Q., Ishihara, H., & Hirata, H. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0033-8 · Cited by 53
Metadata
- Authors
- Osu, R., & Gomi, H.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1999-04-01
- Volume
- 81
- Issue
- 4
- Pages
- 1458-1468
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W1599420468
- Cited by
- 225
- References
- 36
- FWCI
- 4.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.