The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Using a Common Average Reference to Improve Cortical Neuron Recordings From Microelectrode Arrays
Open accessAbstract
In this study, we propose and evaluate a technique known as common average referencing (CAR) to generate a more ideal reference electrode for microelectrode recordings. CAR is a computationally simple technique, and therefore amenable to both on-chip and real-time applications. CAR is commonly used in EEG, where it is necessary to identify small signal sources in very noisy recordings. To study the efficacy of common average referencing, we compared CAR to both referencing with a stainless steel bone-screw and a single microelectrode site. Data consisted of in vivo chronic recordings in anesthetized Sprague-Dawley rats drawn from prior studies, as well as previously unpublished data. By combining the data from multiple studies, we generated and analyzed one of the more comprehensive chronic neural recording datasets to date. Reference types were compared in terms of noise level, signal-to-noise ratio, and number of neurons recorded across days. Common average referencing was found to drastically outperform standard types of electrical referencing, reducing noise by >30%. As a result of the reduced noise floor, arrays referenced to a CAR yielded almost 60% more discernible neural units than traditional methods of electrical referencing. CAR should impart similar benefits to other microelectrode recording technologies—for example, chemical sensing—where similar differential recording concepts apply. In addition, we provide a mathematical justification for CAR using Gauss-Markov theorem and therefore help place the application of CAR into a theoretical context.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pattern Recognition with Fuzzy Objective Function Algorithms
Bezdek, J. C. (1981) · doi:10.1007/978-1-4757-0450-1 · Cited by 9,881
A Fuzzy Relative of the ISODATA Process and Its Use in Detecting Compact Well-Separated Clusters
Dunn, J. C. (1973) · Journal of Cybernetics · doi:10.1080/01969727308546046 · Cited by 5,049
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x/9/4/001 · Cited by 1,370
Harris, K. D., Henze, D. A., Csicsvari, J., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,151
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Gray, C. M., Maldonado, P. E., Wilson, M., & McNaughton, B. (1995) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00085-2 · Cited by 742
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Self-citationRegression and the Moore-Penrose Pseudoinverse.
Troskie, C. G., & Albert, A. (1975) · Journal of the American Statistical Association · doi:10.2307/2285416 · Cited by 620
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Cui, X., & Martin, D. C. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00448-3 · Cited by 573
Schwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 559
Probability and Random Processes with Applications to Signal Processing
Stark, H., & Woods, J. (2001) · Medical Entomology and Zoology · Cited by 508
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Self-citationNeural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
Self-citationSuner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · cited 1×
“1 or greater corresponded well with observations of “moderate or better” unit quality based on SNR values from similar recording studies (Henze et al. 2000; Ludwig et al. 2006; Suner et al. 2005).”
BackgroundWilliams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Brain Research Protocols · doi:10.1016/s1385-299x(99)00034-3 · Cited by 395
Self-citationBurmeister, J. J., & Gerhardt, G. A. (2001) · Analytical Chemistry · doi:10.1021/ac0010429 · Cited by 289
Polytrodes: High-Density Silicon Electrode Arrays for Large-Scale Multiunit Recording
Blanche, T. J., Spacek, M. A., Hetke, J. F., & Swindale, N. V. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01023.2004 · Cited by 282
Liu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 271
Neuroprosthetics : Theory and Practice
Horch, K., & Dhillon, G. S. (2004) · doi:10.1142/4987#t=toc · Cited by 215
Spataro, L., Dilgen, J., Retterer, S., Spence, A. J., Isaacson, M., Turner, J. N., & Shain, W. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2004.08.037 · Cited by 215
Multivariate denoising using wavelets and principal component analysis
Aminghafari, M., Cheze, N., & Poggi, J.-M. (2006) · Computational Statistics & Data Analysis · doi:10.1016/j.csda.2004.12.010 · Cited by 193
Biocompatibility of silicon‐based electrode arrays implanted in feline cortical tissue
Schmidt, S., Horch, K., & Normann, R. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271106 · Cited by 183
Suppression of axonal conduction by sinusoidal stimulation in rat hippocampus in vitro
Jensen, A. L., & Durand, D. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/001 · Cited by 180
Review of signal distortion through metal microelectrode recording circuits and filters
Nelson, M. J., Pouget, P., Nilsen, E. A., Patten, C. D., & Schall, J. D. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.12.010 · Cited by 167
HermesB: A Continuous Neural Recording System for Freely Behaving Primates
Santhanam, G., Linderman, M. D., Gilja, V., Afshar, A., Ryu, S. I., Meng, T. H. Y., & Shenoy, K. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895753 · Cited by 152
The EEG as potential mapping: The value of the average monopolar reference
Offner, F. F. (1950) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(50)90040-x · Cited by 147
Yang, J., Kim, D., Hendricks, J. L., Leach, M. K., Northey, R., & Martin, D. C. (2004) · Acta Biomaterialia · doi:10.1016/j.actbio.2004.09.006 · Cited by 135
Otto, K. J., Johnson, M. D., & Kipke, D. R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862530 · Cited by 134
Self-citationRepeated voltage biasing improves unit recordings by reducing resistive tissue impedances
Johnson, M. D., Otto, K. J., & Kipke, D. R. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847373 · Cited by 130
Self-citationMinocycline increases quality and longevity of chronic neural recordings
Rennaker, R. L., Miller, J., Tang, H., & Wilson, D. A. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/l01 · Cited by 123
Extracellular Single-Unit Recording Methods
Humphrey, D. R., & Schmidt, E. M. (2003) · Humana Press eBooks · doi:10.1385/0-89603-185-3:1 · Cited by 101
Spatiotemporal pH dynamics following insertion of neural microelectrode arrays
Johnson, M. D., Kao, O. E., & Kipke, D. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.023 · Cited by 93
Self-citationSignal-to-noise ratio improvement in multiple electrode recording
Musiał, P., Baker, S. N., Gerstein, G. L., King, E. A., & Keating, J. G. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00516-7 · Cited by 73
Neuroprosthetics: Theory and Practice
Horch, K. W., & Dhillon, G. S. (2004) · Series on Bioengineering and Biomedical Engineering · doi:10.1142/4987 · Cited by 70
Zouridakis, G., & Tam, D. C. (2000) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(99)00032-2 · Cited by 69
Carbon fiber microelectrodes with multiple sensing elements for in vivo voltammetry
Dressman, S. F., Peters, J. L., & Michael, A. C. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00180-2 · Cited by 41
Noise reduction in multichannel neural recordings using a new array wavelet denoising algorithm
Oweiss, K. G., & Anderson, D. J. (2001) · Neurocomputing · doi:10.1016/s0925-2312(01)00533-1 · Cited by 39
Self-citationMulti-channel spike detection and sorting using an array processing technique
Bierer, S. M., & Anderson, D. J. (1999) · Neurocomputing · doi:10.1016/s0925-2312(99)00090-9 · Cited by 36
Self-citationDynamic local search for clustering with unknown number of clusters
Kärkkäinen, I., & Fränti, P. (2003) · doi:10.1109/icpr.2002.1048283 · Cited by 30
THE THEORY OF CENTRAL NERVOUS SYSTEM RECORDING
Shoham, S., & Nagarajan, S. S. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0014 · Cited by 10
Cited by
Spontaneous behaviors drive multidimensional, brainwide activity
Stringer, C., Pachitariu, M., Steinmetz, N., Reddy, C. B., Carandini, M., & Harris, K. D. (2019) · Science · doi:10.1126/science.aav7893 · Cited by 1,510
Distributed coding of choice, action and engagement across the mouse brain
Steinmetz, N. A., Zatka-Haas, P., Carandini, M., & Harris, K. D. (2019) · Nature · doi:10.1038/s41586-019-1787-x · Cited by 765
Kilosort: realtime spike-sorting for extracellular electrophysiology with hundreds of channels
Pachitariu, M., Steinmetz, N., Kadir, S., Carandini, M., & Kenneth D., H. (2016) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/061481 · Cited by 740
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
Self-citationJarosiewicz, B., Sarma, A. A., Bacher, D., Masse, N. Y., Simeral, J. D., Sorice, B., Oakley, E. M., Blabe, C., Pandarinath, C., Gilja, V., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac7328 · Cited by 340
Metadata
- Authors
- Ludwig, K. A., Miriani, R. M., Langhals, N. B., Joseph, M. D., Anderson, D. J., & Kipke, D. R.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2009-03
- Volume
- 101
- Issue
- 3
- Pages
- 1679-1689
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2103032521
- Cited by
- 420
- References
- 47
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).