Optical Image-Guided Cancer Surgery: Challenges and Limitations
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Optical image-guided cancer surgery is a promising technique to adequately determine tumor margins by tumor-specific targeting, potentially resulting in complete resection of tumor tissue with improved survival. However, identification of the photons coming from the fluorescent contrast agent is complicated by autofluorescence, optical tissue properties, and accurate fluorescent targeting agents and imaging systems. All these factors have an important influence on the image that is presented to the surgeon. Considering the clinical consequences at stake, it is a prerequisite to answer the questions that are essential for the surgeon. What is optical image-guided surgery and how can it improve patient care? What should the oncologic surgeon know about the fundamental principles of optical imaging to understand which conclusions can be drawn from the images? And how do the limitations influence clinical decision making? This article discusses these questions and provides a clear overview of the basic principles and practical applications. Although there are limitations to the intrinsic capacity of the technique, when practical and technical surgical possibilities are considered, optical imaging can be a very powerful intraoperative tool in guiding the future oncologic surgeon toward radical resection and optimal clinical results. Clin Cancer Res; 19(14); 3745–54. ©2013 AACR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanahan, D., & Weinberg, R. A. (2000) · Cell · doi:10.1016/s0092-8674(00)81683-9 · Cited by 29,219
Fang, J., Nakamura, H., & Maeda, H. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.04.009 · Cited by 3,559
Stummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423
In vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
Imaging in the era of molecular oncology
Weissleder, R., & Pittet, M. J. (2008) · Nature · doi:10.1038/nature06917 · Cited by 2,364
Vessel Cooption, Regression, and Growth in Tumors Mediated by Angiopoietins and VEGF
Holash, J., Maisonpierre, P. C., Compton, D., Boland, P., Alexander, C. R., Zagzag, D., Yancopoulos, G. D., & Wiegand, S. J. (1999) · Science · doi:10.1126/science.284.5422.1994 · Cited by 2,195
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896 · cited 2×
“The resolution in photoacoustic imaging is not limited by tissue scattering but by the attenuation of acoustic frequencies by tissue (12, 25).”
BackgroundMethodIn vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Looking and listening to light: the evolution of whole-body photonic imaging
Ntziachristos, V., Ripoll, J., Wang, L. V., & Weissleder, R. (2005) · Nature Biotechnology · doi:10.1038/nbt1074 · Cited by 1,557
van Dam, G. M., Themelis, G., Crane, L. M. A., Harlaar, N. J., Pleijhuis, R. G., Kelder, W., Sarantopoulos, A., de Jong, J. S., Arts, H. J. G., van der Zee, A. G. J., et al. (2011) · Nature Medicine · doi:10.1038/nm.2472 · Cited by 1,545
Kircher, M. F., de la Zerda, A., Jokerst, J. V., Zavaleta, C. L., Kempen, P. J., Mittra, E., Pitter, K., Huang, R., Campos, C., Habte, F., et al. (2012) · Nature Medicine · doi:10.1038/nm.2721 · Cited by 1,064
Near-infrared fluorescence: application to in vivo molecular imaging
Hilderbrand, S. A., & Weissleder, R. (2010) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2009.09.029 · Cited by 1,023
Schaafsma, B. E., Mieog, J. S. D., Hutteman, M., van der Vorst, J. R., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. H., & Vahrmeijer, A. L. (2011) · Journal of Surgical Oncology · doi:10.1002/jso.21943 · Cited by 816
Self-citationNew Technologies for Human Cancer Imaging
Frangioni, J. V. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.3065 · Cited by 800
Walter, S., Susanne, S., Simon, W., Herbert, S., Clemens, F., Claudia, G., Alwin, E. G., Rainer, K., & Hans, J. R. (1998) · Neurosurgery · doi:10.1097/00006123-199803000-00017 · Cited by 690
Image-Guided Surgery Using Invisible Near-Infrared Light: Fundamentals of Clinical Translation
Gioux, S., Choi, H. S., & Frangioni, J. V. (2010) · Molecular Imaging · doi:10.2310/7290.2010.00034 · Cited by 599
Role of Angiogenesis in Human Tumor Dormancy: Animal Models of the Angiogenic Switch
Naumov, G. N., Akslen, L. A., & Folkman, J. (2006) · Cell Cycle · doi:10.4161/cc.5.16.3018 · Cited by 500
Blum, G., von Degenfeld, G., Merchant, M. J., Blau, H. M., & Bogyo, M. (2007) · Nature Chemical Biology · doi:10.1038/nchembio.2007.26 · Cited by 467
Spectral Imaging and Linear Unmixing in Light Microscopy
Zimmermann, T. (2005) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/b102216 · Cited by 302 · cited 1×
“linear unmixing), the contribution of each fluorophore in a total fluorescent signal can be extracted (29).”
BackgroundStummer, W., Stepp, H., Möller, G., Ehrhardt, A., Leonhard, M., & Reulen, H. J. (1998) · Acta Neurochirurgica · doi:10.1007/s007010050206 · Cited by 281
Handbook of Biomedical Fluorescence
(2003) · CRC Press eBooks · doi:10.1201/9780203912096 · Cited by 265
The status of in vivo autofluorescence spectroscopy and imaging for oral oncology
De Veld, D. C. G., Witjes, M. J. H., Sterenborg, H. J. C. M., & Roodenburg, J. L. N. (2005) · Oral Oncology · doi:10.1016/j.oraloncology.2004.07.007 · Cited by 264
Self-citationMieog, J. S. D., Troyan, S. L., Hutteman, M., Donohoe, K. J., van der Vorst, J. R., Stockdale, A., Liefers, G.-J., Choi, H. S., Gibbs-Strauss, S. L., Putter, H., et al. (2011) · Annals of Surgical Oncology · doi:10.1245/s10434-011-1566-x · Cited by 249
Self-citationBird-Lieberman, E. L., Neves, A. A., Lao-Sirieix, P., O'Donovan, M., Novelli, M., Lovat, L. B., Eng, W. S., Mahal, L. K., Brindle, K. M., & Fitzgerald, R. C. (2012) · Nature Medicine · doi:10.1038/nm.2616 · Cited by 231
Olafsen, T., & Wu, A. M. (2010) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2009.12.005 · Cited by 223
CHANCE, B. (1998) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1998.tb08185.x · Cited by 216
Rassmussen-Taxdal, D. S., Ward, G. E., & Figge, F. H. J. (1955) · Cancer · doi:10.1002/1097-0142(1955)8:1<78::aid-cncr2820080109>3.0.co;2-l · Cited by 191
Fluorescence lifetime imaging microscopy for brain tumor image-guided surgery
Hatami, N. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3486612 · Cited by 171
Star, W. M. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/003 · Cited by 163
Noura, S., Ohue, M., Seki, Y., Tanaka, K., Motoori, M., Kishi, K., Miyashiro, I., Ohigashi, H., Yano, M., Ishikawa, O., et al. (2009) · Annals of Surgical Oncology · doi:10.1245/s10434-009-0711-2 · Cited by 145
Kovar, J. L., Volcheck, W., Sevick-Muraca, E., Simpson, M. A., & Olive, D. M. (2009) · Analytical Biochemistry · doi:10.1016/j.ab.2008.09.050 · Cited by 133
Towards oncological application of Raman spectroscopy
Nijssen, A., Koljenović, S., Schut, T. C. B., Caspers, P. J., & Puppels, G. J. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200810055 · Cited by 113
Pleijhuis, R. G., Langhout, G. C., Helfrich, W., Themelis, G., Sarantopoulos, A., Crane, L. M. A., Harlaar, N. J., de Jong, J. S., Ntziachristos, V., & van Dam, G. M. (2010) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2010.10.006 · Cited by 94
Rosenthal, E. L., Kulbersh, B. D., King, T., Chaudhuri, T. R., & Zinn, K. R. (2007) · Molecular Cancer Therapeutics · doi:10.1158/1535-7163.mct-06-0741 · Cited by 93
Raman's “Effect” on Molecular Imaging
Zavaleta, C. L., Kircher, M. F., & Gambhir, S. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.087775 · Cited by 88 · cited 1×
“the frequency of excitation photons that changes upon interaction with tissue, which is independent of optical tissue properties or autofluorescence (24, 26).”
BackgroundDetection limits of intraoperative near infrared imaging for tumor resection
Thurber, G. M., Figueiredo, J., & Weissleder, R. (2010) · Journal of Surgical Oncology · doi:10.1002/jso.21735 · Cited by 47
Xie, B.-W., Mol, I. M., Keereweer, S., van Beek, E. R., Que, I., Snoeks, T. J. A., Chan, A. B., Kaijzel, E. L., & Löwik, C. W. G. M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031875 · Cited by 47
Self-citationDiffusion Modeling Of Fluorescence In Tissue
Farrell, T. J., & Patterson, M. S. (2003) · CRC Press eBooks · doi:10.1201/9780203912096-2 · Cited by 22
Cited by
Clinical translation of an ultrasmall inorganic optical-PET imaging nanoparticle probe
Phillips, E., Penate-Medina, O., Zanzonico, P. B., Carvajal, R. D., Mohan, P., Ye, Y., Humm, J., Gönen, M., Kalaigian, H., Schöder, H., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3009524 · Cited by 712
Fundamentals and developments in fluorescence-guided cancer surgery
Mieog, J. S. D., Achterberg, F. B., Zlitni, A., Hutteman, M., Burggraaf, J., Swijnenburg, R.-J., Gioux, S., & Vahrmeijer, A. L. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-021-00548-3 · Cited by 389
Self-citationShao, J., Ruan, C., Xie, H., Li, Z., Wang, H., Chu, P. K., & Yu, X. (2018) · Advanced Science · doi:10.1002/advs.201700848 · Cited by 367
Real-time fluorescence imaging in intraoperative decision making for cancer surgery
Lauwerends, L. J., van Driel, P. B. A. A., Baatenburg de Jong, R. J., Hardillo, J. A. U., Koljenovic, S., Puppels, G., Mezzanotte, L., Löwik, C. W. G. M., Rosenthal, E. L., Vahrmeijer, A. L., et al. (2021) · The Lancet Oncology · doi:10.1016/s1470-2045(20)30600-8 · Cited by 276
Self-citationHoogstins, C. E. S., Tummers, Q. R. J. G., Gaarenstroom, K. N., de Kroon, C. D., Trimbos, J. B. M. Z., Bosse, T., Smit, V. T. H. B. M., Vuyk, J., van de Velde, C. J. H., Cohen, A. F., et al. (2016) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-15-2640 · Cited by 271
Self-citation
Metadata
- Authors
- Keereweer, S., Van Driel, P. B. A. A., Snoeks, T. J. A., Kerrebijn, J. D. F., Baatenburg de Jong, R. J., Vahrmeijer, A. L., Sterenborg, H. J. C. M., & Löwik, C. W. G. M.
- Venue
- Clinical Cancer Research
- Published
- 2013-07-15
- Volume
- 19
- Issue
- 14
- Pages
- 3745-3754
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2144917539
- Cited by
- 270
- References
- 39
- FWCI
- 15.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.