Safety and Tumor Specificity of Cetuximab-IRDye800 for Surgical Navigation in Head and Neck Cancer
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Purpose: Positive margins dominate clinical outcomes after surgical resections in most solid cancer types, including head and neck squamous cell carcinoma. Unfortunately, surgeons remove cancer in the same manner they have for a century with complete dependence on subjective tissue changes to identify cancer in the operating room. To effect change, we hypothesize that EGFR can be targeted for safe and specific real-time localization of cancer. Experimental Design: A dose escalation study of cetuximab conjugated to IRDye800 was performed in patients (n = 12) undergoing surgical resection of squamous cell carcinoma arising in the head and neck. Safety and pharmacokinetic data were obtained out to 30 days after infusion. Multi-instrument fluorescence imaging was performed in the operating room and in surgical pathology. Results: There were no grade 2 or higher adverse events attributable to cetuximab-IRDye800. Fluorescence imaging with an intraoperative, wide-field device successfully differentiated tumor from normal tissue during resection with an average tumor-to-background ratio of 5.2 in the highest dose range. Optical imaging identified opportunity for more precise identification of tumor during the surgical procedure and during the pathologic analysis of tissues ex vivo. Fluorescence levels positively correlated with EGFR levels. Conclusions: We demonstrate for the first time that commercially available antibodies can be fluorescently labeled and safely administered to humans to identify cancer with sub-millimeter resolution, which has the potential to improve outcomes in clinical oncology. Clin Cancer Res; 21(16); 3658–66. ©2015 AACR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423 · cited 1×
“The use of 5–ALA for glioma surgery has advanced to phase III clinical trials where it was shown to improve oncologic and functional outcomes (5).”
Methodvan Dam, G. M., Themelis, G., Crane, L. M. A., Harlaar, N. J., Pleijhuis, R. G., Kelder, W., Sarantopoulos, A., de Jong, J. S., Arts, H. J. G., van der Zee, A. G. J., et al. (2011) · Nature Medicine · doi:10.1038/nm.2472 · Cited by 1,545
Ang, K. K., Berkey, B. A., Tu, X., Zhang, H. Z., Katz, R. L., Hammond, E. H., Fu, K. K., & Milas, L. (2002) · PubMed · Cited by 1,398
Levels of TGF-α and EGFR Protein in Head and Neck Squamous Cell Carcinoma and Patient Survival
Grandis, J. R., Melhem, M. F., Gooding, W. E., Day, R., Holst, V. A., Wagener, M. M., Drenning, S. D., & Tweardy, D. J. (1998) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/90.11.824 · Cited by 1,113
Stummer, W., Novotny, A., Stepp, H., Goetz, C., Bise, K., & Reulen, H. J. (2000) · Journal of Neurosurgery · doi:10.3171/jns.2000.93.6.1003 · Cited by 881
Single-Dose Intravenous Toxicity Study of IRDye 800CW in Sprague-Dawley Rats
Marshall, M. V., Draney, D., Sevick-Muraca, E. M., & Olive, D. M. (2010) · Molecular Imaging and Biology · doi:10.1007/s11307-010-0317-x · Cited by 231
Clinical update on cancer: molecular oncology of head and neck cancer
Suh, Y., Amelio, I., Guerrero Urbano, T., & Tavassoli, M. (2014) · Cell Death & Disease · doi:10.1038/cddis.2013.548 · Cited by 188
Practical Theoretic Guidance for the Design of Tumor-Targeting Agents
Wittrup, K. D., Thurber, G. M., Schmidt, M. M., & Rhoden, J. J. (2012) · Methods in Enzymology · doi:10.1016/b978-0-12-396962-0.00010-0 · Cited by 171
Li, Y., Rey‐Dios, R., Roberts, D. W., Valdes, P. A., & Cohen‐Gadol, A. (2013) · World Neurosurgery · doi:10.1016/j.wneu.2013.06.014 · Cited by 167
Fluorescence-guided resections of malignant gliomas—An Overview
Stummer, W., Reulen, H. J., Novotny, A., Steppe, H., & Tonn, J. C. (2003) · Local Therapies for Glioma Present Status and Future Developments · doi:10.1007/978-3-7091-6090-9_3 · Cited by 128
Cited by
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Near‐Infrared‐II Molecular Dyes for Cancer Imaging and Surgery
Zhu, S., Tian, R., Antaris, A. L., Chen, X., & Dai, H. (2019) · Advanced Materials · doi:10.1002/adma.201900321 · Cited by 972
Beyond the margins: real-time detection of cancer using targeted fluorophores
Zhang, R. R., Schroeder, A. B., Grudzinski, J. J., Rosenthal, E. L., Warram, J. M., Pinchuk, A. N., Eliceiri, K. W., Kuo, J. S., & Weichert, J. P. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2016.212 · Cited by 485
Self-citationLatest developments in molecular tracers for fluorescence image-guided cancer surgery
Hernot, S., van Manen, L., Debie, P., Mieog, J. S. D., & Vahrmeijer, A. L. (2019) · The Lancet Oncology · doi:10.1016/s1470-2045(19)30317-1 · Cited by 471
Mallidi, S., Anbil, S., Bulin, A.-L., Obaid, G., Ichikawa, M., & Hasan, T. (2016) · Theranostics · doi:10.7150/thno.16183 · Cited by 449
Nagaya, T., Nakamura, Y. A., Choyke, P. L., & Kobayashi, H. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00314 · Cited by 398
Fundamentals and developments in fluorescence-guided cancer surgery
Mieog, J. S. D., Achterberg, F. B., Zlitni, A., Hutteman, M., Burggraaf, J., Swijnenburg, R.-J., Gioux, S., & Vahrmeijer, A. L. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-021-00548-3 · Cited by 389
Photobleaching of organic fluorophores: quantitative characterization, mechanisms, protection *
Demchenko, A. P. (2020) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/ab7365 · Cited by 370
Biocompatible Semiconductor Quantum Dots as Cancer Imaging Agents
McHugh, K. J., Jing, L., Behrens, A. M., Jayawardena, S., Tang, W., Gao, M., Langer, R., & Jaklenec, A. (2018) · Advanced Materials · doi:10.1002/adma.201706356 · Cited by 318
Near-Infrared-II (NIR-II) Bioimaging via Off-Peak NIR-I Fluorescence Emission
Zhu, S., Yung, B. C., Chandra, S., Niu, G., Antaris, A. L., & Chen, X. (2018) · Theranostics · doi:10.7150/thno.27995 · Cited by 303
Lamberts, L. E., Koch, M., de Jong, J. S., Adams, A. L. L., Glatz, J., Kranendonk, M. E. G., Terwisscha van Scheltinga, A. G. T., Jansen, L., de Vries, J., Lub-de Hooge, M. N., et al. (2017) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-16-0437 · Cited by 285
Self-citationReal-time fluorescence imaging in intraoperative decision making for cancer surgery
Lauwerends, L. J., van Driel, P. B. A. A., Baatenburg de Jong, R. J., Hardillo, J. A. U., Koljenovic, S., Puppels, G., Mezzanotte, L., Löwik, C. W. G. M., Rosenthal, E. L., Vahrmeijer, A. L., et al. (2021) · The Lancet Oncology · doi:10.1016/s1470-2045(20)30600-8 · Cited by 276
Self-citationHoogstins, C. E. S., Tummers, Q. R. J. G., Gaarenstroom, K. N., de Kroon, C. D., Trimbos, J. B. M. Z., Bosse, T., Smit, V. T. H. B. M., Vuyk, J., van de Velde, C. J. H., Cohen, A. F., et al. (2016) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-15-2640 · Cited by 271
Garland, M., Yim, J. J., & Bogyo, M. (2016) · Cell Chemical Biology · doi:10.1016/j.chembiol.2015.12.003 · Cited by 254
Fluorescence image-guided tumour surgery
Wang, K., Du, Y., Zhang, Z., He, K., Cheng, Z., Yin, L., Dong, D., Li, C., Li, W., Hu, Z., et al. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00017-1 · Cited by 239
Determination of Tumor Margins with Surgical Specimen Mapping Using Near-Infrared Fluorescence
Gao, R. W., Teraphongphom, N. T., van den Berg, N. S., Martin, B. A., Oberhelman, N. J., Divi, V., Kaplan, M. J., Hong, S. S., Lu, G., Ertsey, R., et al. (2018) · Cancer Research · doi:10.1158/0008-5472.can-18-0878 · Cited by 218
“This shows improved safety over cetuximab-IRDye800CW, a compound we previously used to demonstrate simple, initial feasibility and safety of a fluorescently labeled anti-EGFR antibody (10).”
BackgroundSelf-citationBai, J.-W., Qiu, S.-Q., & Zhang, G.-J. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01366-y · Cited by 210
Boogerd, L. S. F., Hoogstins, C. E. S., Schaap, D. P., Kusters, M., Handgraaf, H. J. M., van der Valk, M. J. M., Hilling, D. E., Holman, F. A., Peeters, K. C. M. J., Mieog, J. S. D., et al. (2018) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(17)30395-3 · Cited by 198
Gao, R. W., Teraphongphom, N., de Boer, E., Berg, N. S. V. D., Divi, V., Kaplan, M. J., Oberhelman, N. J., Hong, S. S., Capes, E., Colevas, A. D., et al. (2018) · Theranostics · doi:10.7150/thno.24487 · Cited by 190
Self-citationHarnessing Cyanine Reactivity for Optical Imaging and Drug Delivery
Gorka, A. P., Nani, R. R., & Schnermann, M. J. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00384 · Cited by 180
Voskuil, F. J., Steinkamp, P. J., Zhao, T., van der Vegt, B., Koller, M., Doff, J. J., Jayalakshmi, Y., Hartung, J. P., Gao, J., Sumer, B. D., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16814-4 · Cited by 180
Intraoperative Pancreatic Cancer Detection using Tumor-Specific Multimodality Molecular Imaging
Tummers, W. S., Miller, S. E., Teraphongphom, N. T., Gomez, A., Steinberg, I., Huland, D. M., Hong, S., Kothapalli, S.-R., Hasan, A., Ertsey, R., et al. (2018) · Annals of Surgical Oncology · doi:10.1245/s10434-018-6453-2 · Cited by 179
“showed the successful use of cetuximab-IRDye800 to image subclinical fragments of squamous cell carcinoma arising in the head and neck cancer patients.(11) EGFR also is highly expressed in PDAC and is a good target for fluorescence imaging, due to its transmembrane position.”
Self-citationPhotonanomedicine: a convergence of photodynamic therapy and nanotechnology
Obaid, G., Broekgaarden, M., Bulin, A.-L., Huang, H.-C., Kuriakose, J., Liu, J., & Hasan, T. (2016) · Nanoscale · doi:10.1039/c5nr08691d · Cited by 168
Miller, S. E., Tummers, W. S., Teraphongphom, N., van den Berg, N. S., Hasan, A., Ertsey, R. D., Nagpal, S., Recht, L. D., Plowey, E. D., Vogel, H., et al. (2018) · Journal of Neuro-Oncology · doi:10.1007/s11060-018-2854-0 · Cited by 160
“Moreover, we have demonstrated that a higher dose of cetuximab-IRDye800 leads to improved delineation between tumor and normal tissue, which is consistent with the aforementioned study in squamous cell carcinoma (SCC) with this agent [9], where increased doses led to higher signals in the primary tumor.”
BackgroundResultInfluentialSelf-citationBartelink, I. H., Jones, E. F., Shahidi‐Latham, S. K., Lee, P. R. E., Zheng, Y., Vicini, P., van ‘t Veer, L., Wolf, D., Iagaru, A., Kroetz, D. L., et al. (2019) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.1211 · Cited by 96
Research on Data Security and Privacy Protection of Wearable Equipment in Healthcare
Jiang, D., & Shi, G. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/6656204 · Cited by 48
“In terms of detection, Na et al. developed a hearing aid dynamic electromechanical device [16]; in terms of surgical navigation, Rosenthal and Harmsen designed a visual navigation software for cancer tumor resection [17–19].”
MethodRetractedCharacterizing short-wave infrared fluorescence of conventional near-infrared fluorophores
Byrd, B. K., Folaron, M. R., Leonor, J. P., Strawbridge, R. R., Cao, X., Brůža, P., & Davis, S. C. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.3.035004 · Cited by 22
“approved for human use in several clinical indications, and IRDye 800CW has been used widely in preclinical models and is under clinical investigation for a variety of indications.(12) The”
Method
Metadata
- Authors
- Rosenthal, E. L., Warram, J. M., de Boer, E., Chung, T. K., Korb, M. L., Brandwein-Gensler, M., Strong, T. V., Schmalbach, C. E., Morlandt, A. B., Agarwal, G., Hartman, Y. E., Carroll, W. R., Richman, J. S., Clemons, L. K., Nabell, L. M., & Zinn, K. R.
- Venue
- Clinical Cancer Research
- Published
- 2015-08-13
- Volume
- 21
- Issue
- 16
- Pages
- 3658-3666
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2106235642
- Cited by
- 469
- References
- 17
- FWCI
- 35.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.