The DOI matches its Crossref record.
Subsurface Imaging of Living Skin with Optical Coherence Microscopy
Abstract
BACKGROUND: A new type of microscope has been developed for acquiring cross-sectional images of living skin noninvasively. It takes advantage of the short temporal coherence of a broad-band light source to reject scattered light. Because this microscope is still in an early stage of development, its potential as a diagnostic tool in dermatology has not yet been determined. OBJECTIVE: This study was designed to explore potential applications of optical coherence microscopy in dermatology. The aim was to investigate the structures in skin that can be seen without staining or using sophisticated image-processing methods. METHODS: A prototype fiberoptic microscope was assembled that uses a 1,300-nm light-emitting diode as a light source. Scans were obtained from the skin on the index finger and forearm. Subsurface structures were identified based on knowledge of the anatomy of normal healthy skin. RESULTS: Structures located as deep as 1 mm below the surface of the skin could be imaged with a resolution of about 10 microns in the axial and lateral dimensions. In optical slices taken perpendicular to the skin surface, the contours of the epidermal ridges and the boundary between the epidermis and dermis were readily observed. CONCLUSIONS: The results of this study suggest that an optical coherence microscope may have value as a diagnostic tool for cases in which visualization of subcellular details is not required. The resolution, contrast and scanning speed of the microscope need to be improved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364
Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Biomechanical Properties of In Vivo Human Skin From Dynamic Optical Coherence Elastography
Liang, X., & Boppart, S. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033464 · Cited by 470
Combined In Vivo Confocal Raman Spectroscopy and Confocal Microscopy of Human Skin
Caspers, P. J., Lucassen, G. W., & Puppels, G. J. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74501-9 · Cited by 446
Optical coherence tomography of the human skin
Welzel, J., Lankenau, E., Birngruber, R., & Engelhardt, R. (1997) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(97)70072-0 · Cited by 442
Terahertz Pulse Imaging of ex vivo Basal Cell Carcinoma
Woodward, R. M., Wallace, V. P., Pye, R. J., Cole, B. E., Arnone, D. D., Linfield, E. H., & Pepper, M. (2003) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2003.12013.x · Cited by 434
Full-field optical coherence microscopy
Beaurepaire, E., Boccara, A. C., Lebec, M., Blanchot, L., & Saint-Jalmes, H. (1998) · Optics Letters · doi:10.1364/ol.23.000244 · Cited by 433
Optical coherence tomography and microscopy in gastrointestinal tissues
Izatt, J. A., Kulkarni, M. D., Wang, H.-W., Kobayashi, K., & Sivak, M. V. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577331 · Cited by 350
Turbulent nature of refractive-index variations in biological tissue
Schmitt, J. M., & Kumar, G. (1996) · Optics Letters · doi:10.1364/ol.21.001310 · Cited by 343
Self-citationTerahertz pulsed imaging of basal cell carcinoma ex vivo and in vivo
Wallace, V. P., Fitzgerald, A. J., Shankar, S., Flanagan, N., Pye, R., Cluff, J., & Arnone, D. D. (2004) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2004.06129.x · Cited by 329
Recruitment of Tendon Crimp With Applied Tensile Strain
Hansen, K. A., Weiss, J. A., & Barton, J. K. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427698 · Cited by 285
High resolution in vivo intra-arterial imaging with optical coherence tomography
Fujimoto, J. G., Boppart, S. A., Tearney, G. J., Bouma, B. E., Pitris, C., & Brezinski, M. E. (1999) · Heart · doi:10.1136/hrt.82.2.128 · Cited by 276
In vivo cellular optical coherence tomography imaging
Boppart, S. A., Bouma, B. E., Pitris, C., Southern, J. F., Brezinski, M. E., & Fujimoto, J. G. (1998) · Nature Medicine · doi:10.1038/nm0798-861 · Cited by 268
Advances in Optical Coherence Tomography Imaging for Dermatology
Pierce, M. C., Strasswimmer, J., Hyle Park, B., Cense, B., & de Boer, J. F. (2004) · Journal of Investigative Dermatology · doi:10.1111/j.0022-202x.2004.23404.x · Cited by 257
Optical coherence tomography for the characterization of basal cell carcinoma in vivo: A pilot study
Olmedo, J. M., Warschaw, K. E., Schmitt, J. M., & Swanson, D. L. (2006) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2006.03.013 · Cited by 120
Self-citationBarton, J. K., Gossage, K. W., Xu, W., Ranger-Moore, J. R., Saboda, K., Brooks, C. A., Duckett, L. D., Salasche, S. J., Warneke, J. A., & Alberts, D. S. (2003) · Technology in Cancer Research & Treatment · doi:10.1177/153303460300200605 · Cited by 85
Metadata
- Authors
- Schmitt, J. M., Yadlowsky, M. J., & Bonner, R. F.
- Venue
- Dermatology
- Publisher
- S. Karger AG
- Published
- 1995
- Volume
- 191
- Issue
- 2
- Pages
- 93-98
- ISSN
- 1018-8665 (ISSN-L)
- 1421-9832
- OpenAlex
- W2063352593
- Cited by
- 251
- References
- 0
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.