The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Mechanism of Syncope in Patients With Heart Disease and Negative Electrophysiologic Test
Abstract
BACKGROUND: In patients with syncope and structural heart disease, syncope is suspected to be attributable to a primary cardiac arrhythmia, but little is known of its mechanism when electrophysiologic study is unremarkable. METHODS AND RESULTS: We applied an implantable loop recorder in 35 patients with overt heart disease at risk of ventricular arrhythmia, because these were patients with previous myocardial infarction or cardiomyopathy with depressed ejection fraction or nonsustained ventricular tachycardia in whom an electrophysiologic study was unremarkable. During a follow-up of 3 to 15 months, syncope recurred in 6 patients (17%) after a mean of 6+/-5 months; in 3 patients, the mechanism of syncope was bradycardia with long pauses (sudden-onset AV block in 2 cases and sinus arrest in 1 case); in 1 patient, there was stable sinus tachycardia; and in 2 patients, who had chronic atrial fibrillation, there was an increase in ventricular rate. A total of 23 episodes of presyncope were documented in 8 patients (23%): no rhythm variation or mild tachycardia in 12 cases, paroxysmal atrial fibrillation or atrial tachycardia in 10 cases, and sustained ventricular tachycardia in 1 case. No patient died during the study period nor suffered from injury attributable to syncopal relapse. CONCLUSIONS: The patients with unexplained syncope, structural heart disease, and negative electrophysiologic study had a favorable medium-term outcome with no case of death and a low recurrence rate of syncope without related injury. The mechanism of syncope was heterogeneous, and ventricular tachyarrhythmia was unlikely.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Similar findings were subsequently observed with ILR use expanded in an early phase of evaluation in patients with recurrent syncope of uncertain origin, in the absence of highrisk criteria and structural heart disease, 176,180-183 and in suspected reflex syncope. 184-186 In particular, an asystolic pause was present during syncope in about 50% of these patients.”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [180]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Risk Stratification and Survival after Myocardial Infarction
The Multicenter Postinfarction Research Group (1983) · New England Journal of Medicine · doi:10.1056/nejm198308113090602 · Cited by 1,599
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951
Diagnostic value of history in patients with syncope with or without heart disease
Alboni, P., Brignole, M., Menozzi, C., Raviele, A., Del Rosso, A., Dinelli, M., Solano, A., & Bottoni, N. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01241-4 · Cited by 444
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2001) · Circulation · doi:10.1161/01.cir.104.1.46 · Cited by 405
Mechanism of Syncope in Patients With Isolated Syncope and in Patients With Tilt-Positive Syncope
Moya, A., Brignole, M., Menozzi, C., Garcia-Civera, R., Tognarini, S., Mont, L., Botto, G., Giada, F., Cornacchia, D., & on behalf of the International Study on Syncope of Uncertain Etiology (ISSUE) Investigators (2001) · Circulation · doi:10.1161/hc3601.095708 · Cited by 378
Self-citationUse of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
Mechanism of syncope in patients with bundle branch block and negative electrophysiological test
Brignole, M., Menozzi, C., Moya, A., Garcia-Civera, R., Mont, L., Alvarez, M., Errazquin, F., Beiras, J., Bottoni, N., Donateo, P., et al. (2001) · Circulation · doi:10.1161/hc4201.097837 · Cited by 328
Syncope in advanced heart failure: high risk of sudden death regardless of origin of syncope
Middlekauff, H. R., Stevenson, W. G., Stevenson, L. W., & Saxon, L. A. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90724-f · Cited by 311
Risk stratification of patients with syncope
Martin, T. P., Hanusa, B. H., & Kapoor, W. N. (1997) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(97)70217-8 · Cited by 285
Risk Factors for Syncope Recurrence After a Positive Tilt-Table Test in Patients With Syncope
Sheldon, R. S., Rose, S., Flanagan, P., Koshman, M. L., & Killam, S. (1996) · Circulation · doi:10.1161/01.cir.93.5.973 · Cited by 231
Cited by
Sorted by citations
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., CHAITMAN, B. R., FROMER, M. A., Gregoratos, G., Klein, G. J., Myerburg, R. J., Quiñones, M. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.010 · Cited by 1,975
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., CHAITMAN, B. R., FROMER, M. A., Gregoratos, G., Klein, G. J., Moss, A. J., Myerburg, R. J., et al. (2006) · EP Europace · doi:10.1093/europace/eul108 · Cited by 741
Guidelines on Management (diagnosis and treatment) of syncope ? update 2004
Brignole, M., Alboni, P., Benditt, D. G., Bergfeldt, L., Blanc, J., Thomsen, P. E. B., van Dijk, J. G., Fitzpatrick, A. P., Hohnloser, S. H., Janousek, J., et al. (2004) · EP Europace · doi:10.1016/j.eupc.2004.08.008 · Cited by 650
Guidelines on management (diagnosis and treatment) of syncope-update 2004. Executive Summary.
Brignole, M., Alboni, P., Benditt, D. G., Bergfeldt, L., Blanc, J., Thomsen, P. E. B., van Dijk, J. G., Fitzpatrick, A. P., Hohnloser, S. H., Janoušek, J., et al. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.09.004 · Cited by 566
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
Guía de práctica clínica para el diagnóstico y manejo del síncope (versión 2009)
Moya‐Mitjans, À., Sutton, R., Ammirati, F., Blanc, J., Brignole, M., Dahm, J. B., Deharo, J., Gajek, J. J., Gjesdal, K., Krahn, A. D., et al. (2009) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(09)73541-8 · Cited by 277
SOLANO, A. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.05.013 · Cited by 122
Diagnosis, management, and outcomes of patients with syncope and bundle branch block
Moya, A., Garcia-Civera, R., Croci, F., Menozzi, C., Brugada, J., Ammirati, F., Del Rosso, A., Bellver-Navarro, A., Garcia-Sacristan, J., Bortnik, M., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr071 · Cited by 124
Implantable loop recorder in clinical practice
Bisignani, A., Bonis, S. D., Mancuso, L., Ceravolo, G., & Bisignani, G. (2018) · Journal of Arrhythmia · doi:10.1002/joa3.12142 · Cited by 116
Brignole, M., Moya‐Mitjans, À., Menozzi, C., García–Civera, R., & Sutton, R. (2005) · EP Europace · doi:10.1016/j.eupc.2004.11.001 · Cited by 106
Left bundle‐branch block—pathophysiology, prognosis, and clinical management
Francia, P., Balla, C., Paneni, F., & Volpe, M. (2007) · Clinical Cardiology · doi:10.1002/clc.20034 · Cited by 103
Value of the implantable loop recorder for the management of patients with unexplained syncope
Boersma, L. V. A. (2003) · EP Europace · doi:10.1016/j.eupc.2003.09.006 · Cited by 87
Furukawa, T., Maggi, R., Bertolone, C., Fontana, D., & Brignole, M. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02133.x · Cited by 77
Utility of Implantable Loop Recorder (Reveal Plus®) in the Diagnosis of Unexplained Syncope
LOMBARDI, F., CALOSSO, E., MASCIOLI, G., MARANGONI, E., DONATO, A., ROSSI, S., PALA, M., FOTI, F., & LUNATI, M. (2005) · Europace · doi:10.1016/j.eupc.2004.09.003 · Cited by 76
BRIGNOLE, M., MENOZZI, C., MAGGI, R., SOLANO, A., DONATEO, P., BOTTONI, N., LOLLI, G., QUARTIERI, F., CROCI, F., & ODDONE, D. (2005) · Europace · doi:10.1016/j.eupc.2005.02.116 · Cited by 76
New Concepts in the Assessment of Syncope
Brignole, M., & Hamdan, M. H. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.056 · Cited by 76
Management of syncope: clinical and economic impact of a Syncope Unit
Ammirati, F., Colaceci, R., Cesario, A., Strano, S., Della Scala, A., Colangelo, I., De Santo, T., Toscano, E., Ricci, R., & Santini, M. (2008) · Europace · doi:10.1093/europace/eun061 · Cited by 73
The Reveal LINQ insertable cardiac monitor
Tomson, T. T., & Passman, R. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.953059 · Cited by 72
Insertable Loop Recorder Use for Detection of Intermittent Arrhythmias
Krahn, A. D., Klein, G. J., Skanes, A. C., & Yee, R. K. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00502.x · Cited by 66
Ruwald, M. H., Hansen, M. L., Lamberts, M., Hansen, C. M., Numé, A.-K., Vinther, M., Køber, L., Torp-Pedersen, C., Hansen, J., & Gislason, G. H. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.07.041 · Cited by 59
Effectiveness of remote monitoring in the management of syncope and palpitations
Furukawa, T., Maggi, R., Bertolone, C., Ammirati, F., Santini, M., Ricci, R., Giada, F., & Brignole, M. (2011) · Europace · doi:10.1093/europace/euq503 · Cited by 57
Benditt, D. G., & Nguyen, J. T. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.12.065 · Cited by 55
Kubala, M., Aïssou, L., Traullé, S., Gugenheim, A.-L., & Js, H. (2011) · EP Europace · doi:10.1093/europace/eur319 · Cited by 52
Pezawas, T., Stix, G., Kästner, J., Schneider, B., Wolzt, M., & Schmidinger, H. (2007) · Heart · doi:10.1136/hrt.2007.116616 · Cited by 52
Brembilla-Perrot, B., Suty-Selton, C., Beurrier, D., Houriez, P., Nippert, M., Terrier de la Chaise, A., Louis, P., Claudon, O., Andronache, M., Abdelaah, A., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.075 · Cited by 49
Ruwald, M. H., Okumura, K., Kimura, T., Aonuma, K., Shoda, M., Kutyifa, V., Ruwald, A.-C. H., McNitt, S., Zareba, W., & Moss, A. J. (2014) · Circulation · doi:10.1161/circulationaha.113.004196 · Cited by 50
Ermiş, C., Zhu, A. X., Pham, S., Li, J. M., Guerrero, M., Vrudney, A., Hiltner, L., Lü, F., Sakaguchi, S., Lurie, K. G., et al. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00889-0 · Cited by 50
Syncope: Diagnosis and Management
Walsh, K., Hoffmayer, K. S., & Hamdan, M. H. (2014) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2014.11.001 · Cited by 51
Improved Arrhythmia Detection in Implantable Loop Recorders
Brignole, M., Bellardine, C. L., Thomsen, P. E. B., Sutton, R., Moya‐Mitjans, À., STADLER, R. W., Cao, J. J., Messier, M., & Huikuri, H. V. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01156.x · Cited by 46
Berecki-Gisolf, J., SHELDON, A. G., Wieling, W., van Dijk, N., Costantino, G., Furlan, R., Shen, W.-K., & Sheldon, R. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0075255 · Cited by 44
Predicting the cause of syncope from clinical history in patients undergoing prolonged monitoring
Sud, S., Klein, G. J., Skanes, A. C., Gula, L. J., Yee, R., & Krahn, A. D. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2008.10.035 · Cited by 43
Krahn, A. D., Morillo, C. A., Kuś, T., Manns, B., Rose, S., Brignole, M., & Sheldon, R. S. (2012) · EP Europace · doi:10.1093/europace/eus005 · Cited by 43
Pierre, B., Fauchier, L., Breard, G., Marie, O., Poret, P., & Babuty, D. (2008) · EP Europace · doi:10.1093/europace/eun039 · Cited by 42
Insertable cardiac monitors: current indications and devices
Sakhi, R., Theuns, D. A. M. J., Szili‐Törok, T., & Yap, S. (2018) · Expert Review of Medical Devices · doi:10.1080/17434440.2018.1557046 · Cited by 43
Moya, A., Brignole, M., Sutton, R., Menozzi, C., Garcia-Civera, R., Wieling, W., Andresen, D., Benditt, D. G., Garcia-Sacristán, J. F., Beiras, X., et al. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.07.043 · Cited by 38
Recommendations for the use of electrophysiological study: Update 2018
Mureşan, L., Cismaru, G. L., Martins, R. P., Bataglia, A., Roşu, R., Puiu, M., Guşetu, G., Mada, R. O., Muresan, C., Ispas, D. R., et al. (2018) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2018.09.002 · Cited by 37
Use of the Implantable Loop Recorder in Evaluation of Patients with Unexplained Syncope
Krahn, A. D., Klein, G. J., Skanes, A. C., & Yee, R. K. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.14.s9.19.x · Cited by 35
Lacunza-Ruiz, F. J., Moya-Mitjans, A., Martínez-Alday, J., Barón-Esquivias, G., Ruiz-Granell, R., Rivas-Gándara, N., González-Enríquez, S., Leal-del-Ojo, J., F. Arcocha-Torres, M., Pérez-Villacastín, J., et al. (2013) · Circulation Journal · doi:10.1253/circj.cj-13-0201 · Cited by 34
Atrial fibrillation in Brugada syndrome: Current perspectives
Vlachos, K., Mascia, G., Martin, C. A., Bazoukis, G., Frontera, A., Cheniti, G., Letsas, K., Efremidis, M., Georgopoulos, S., Gkalapis, C., et al. (2020) · Cardiovascular Electrophysiology · doi:10.1111/jce.14361 · Cited by 30
Current and Emerging Indications for Implantable Cardiac Monitors
Giada, F., Bertaglia, E., Reimers, B., Noventa, D., & Raviele, A. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03411.x · Cited by 30
Implantable loop recorders in the investigation of unexplained syncope: a state of the art review
Parry, S. W., & Matthews, I. G. (2010) · Heart · doi:10.1136/hrt.2010.193417 · Cited by 31
Paruchuri, V., Adhaduk, M., Garikipati, N. V., Steinberg, J. S., & Mittal, S. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.01.039 · Cited by 28
Benditt, D. G., & Brignole, M. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02928-5 · Cited by 27
Arrhythmic syncope: From diagnosis to management
Pascual, J. F., Jordán-Marchite, P., Silva, J. R., & Rivas‐Gándara, N. (2023) · World Journal of Cardiology · doi:10.4330/wjc.v15.i4.119 · Cited by 29
Utility of implantable loop recorders for diagnosing unexplained syncope in clinical practice
Entem, F. R., Enríquez, S. G., Cobo, M., Expósito, V., Llano, M., Ruiz, M., Olalla, J. J., & Fernández, M. O. (2009) · Clinical Cardiology · doi:10.1002/clc.20342 · Cited by 25
Costa, A. D., Gulian, J.-L., Romeyer-Bouchard, C., Messier, M., Zarqane, N., Samuel, B., Khiel, A., & Isaaz, K. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2005.05.025 · Cited by 25
The use of monitoring strategies in patients with unexplained syncope
Krahn, A. D., Klein, G. J., Yee, R. K., & Skanes, A. C. (2004) · Clinical Autonomic Research · doi:10.1007/s10286-004-1008-y · Cited by 25
Syncope in adults: Systematic review and proposal of a diagnostic and therapeutic algorithm
Rosanio, S., Schwarz, E. R., Ware, D. L., & Vitarelli, A. (2011) · International Journal of Cardiology · doi:10.1016/j.ijcard.2011.11.021 · Cited by 25
Vitale, E., Ungar, A., Maggi, R., Francese, M., Lunati, M., Colaceci, R., Rosso, A. D., Castro, A., Santini, M., Giuli, S., et al. (2010) · EP Europace · doi:10.1093/europace/euq302 · Cited by 24
The implantable loop recorder in children
Yeung, B. P. M., & McLEOD, K. A. (2007) · Heart · doi:10.1136/hrt.2007.121855 · Cited by 23
Arrocha, A., Klein, G. J., Benditt, D. G., Sutton, R., & Krahn, A. D. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02857.x · Cited by 22
Sánchez, J. M., Katsiyiannis, W. T., Gage, B. F., Chen, J. S., Faddis, M. N., Gleva, M. J., Smith, T. W., & Lindsay, B. D. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2004.12.023 · Cited by 22
Ruwald, M. H., & Zaręba, W. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2013.08.007 · Cited by 22
2020 Clinical practice guidelines for Bradyarrhythmias and conduction disorders
Revishvili, A. S., Artyukhina, Е. А., Глезер, М. Г., Базаев, В. А., Batalov, R. E., Bokeria, L. A., Bokeria, O. L., Davtyan, K. V., Ivanitsky, E. A., Ковалев, А. С., et al. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4448 · Cited by 28
Current and Emerging Uses of Insertable Cardiac Monitors
Tomson, T. T., & PASSMAN, R. S. (2016) · Cardiology in Review · doi:10.1097/crd.0000000000000129 · Cited by 20
Cardiac Monitoring in Patients with Syncope: Making that Elusive Diagnosis
Subbiah, R. N., Chia, P., Gula, L. J., Klein, G. J., Skanes, A. C., Yee, R., & Krahn, A. D. (2014) · Current Cardiology Reviews · doi:10.2174/1573403x10666140214120056 · Cited by 18
Syncope: Review of Monitoring Modalities
Krahn, A. D., Subbiah, R. N., Gula, L. J., Klein, G. J., Skanes, A. C., & Yee, R. K. (2008) · Current Cardiology Reviews · doi:10.2174/157340308783565447 · Cited by 20
Kanjwal, K., Kanjwal, Y., Karabin, B. L., & Grubb, B. P. (2009) · International Journal of Medical Sciences · doi:10.7150/ijms.6.106 · Cited by 19
Should we treat severe vasovagal syncope with a pacemaker?
Sutton, R. (2017) · Journal of Internal Medicine · doi:10.1111/joim.12603 · Cited by 19
Rodríguez‐Entem, F., González‐Enríquez, S., Olalla-Antolín, J. J., Cobo-Belaustegui, M., Expósito-García, V., Llano-Cardenal, M., Casanova-Martín, M. A., & Villar, C. R. (2008) · Revista Española de Cardiología · doi:10.1157/13114953 · Cited by 19
Farwell, D. J., & Sulke, A. N. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.10.066 · Cited by 18
García–Civera, R., Ruiz‐Granell, R., Morell‐Cabedo, S., Mañez, R. S., FERRERO, A., Martínez-Brotons, Á. M., ROSELLÓ, A., Solana, S. B., & Llácer, Á. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.50029.x · Cited by 18
Implantable Diagnostic Monitors in the Early Assessment of Syncope and Collapse
Hong, P. S. G., & Sulke, N. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.11.009 · Cited by 17
Syncope in patients with structural heart disease
Arnar, D. O. (2013) · Journal of Internal Medicine · doi:10.1111/joim.12027 · Cited by 17
Lee, S. H., Kim, T.-H., Oh, Y.-S., Oh, S., Choi, J.-I., Kim, J.-B., Nah, J.-C., Im, S. I., Kang, K.-W., Han, S., et al. (2020) · Journal of Korean Medical Science · doi:10.3346/jkms.2020.35.e11 · Cited by 16
Implantable rhythm devices in the management of vasovagal syncope
Solbiati, M., & Sheldon, R. S. (2014) · Autonomic Neuroscience · doi:10.1016/j.autneu.2014.05.012 · Cited by 16
Use of implantable and external loop recorders in syncope with unknown causes
Tanno, K. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.03.006 · Cited by 16
Investigation of optimal position for implantable loop recorders by potential mapping with Reveal DX
Kawashima, A., Tanimoto, F., Nagao, T., Toyoshima, T., & Okuyama, Y. (2014) · Journal of Arrhythmia · doi:10.1016/j.joa.2014.09.005 · Cited by 16
Heart rhythm characterisation during unexplained transient loss of consciousness in dogs
Perego, M., Vàzquez, D. M. P., Ramera, L., Lombardo, S. F., Pane, C., Bontempi, L., & Santilli, R. A. (2020) · The Veterinary Journal · doi:10.1016/j.tvjl.2020.105523 · Cited by 15
Pascual, J. F., Ródenas‐Alesina, E., Rivas‐Gándara, N., Belahnech, Y., Olivella, A., Pérez‐Rodon, J., Benito, B., Santos‐Ortega, A., Moya‐Mitjans, À., Casas, G., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.12.009 · Cited by 13
Rodríguez‐Entem, F., González‐Enríquez, S., Olalla-Antolín, J. J., Cobo-Belaustegui, M., Expósito-García, V., Llano-Cardenal, M., Casanova-Martín, M. A., & Villar, C. R. (2008) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(08)60064-x · Cited by 13
Shanmugam, N., & Liew, R. (2012) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.v41n3p115 · Cited by 13
Investigating syncope: a review
Gould, P. A., Krahn, A. D., Klein, G. J., Yee, R. K., Skanes, A. C., & Gula, L. J. (2005) · Current Opinion in Internal Medicine · doi:10.1097/01.hco.0000198986.16626.86 · Cited by 14
Iravanian, S., Arshad, A., & Steinberg, J. S. (2005) · The American Journal of Geriatric Cardiology · doi:10.1111/j.1076-7460.2005.03354.x · Cited by 13
The ACCF/AHA Scientific Statement on Syncope
Benditt, D. G. (2006) · Clinical Autonomic Research · doi:10.1007/s10286-006-0370-3 · Cited by 13
Neurocardiogenic Mechanisms of Unexplained Syncope in Idiopathic Dilated Cardiomyopathy
LIVANIS, E. G., Κωστοπούλου, Ά., THEODORAKIS, G. N., Aggelopoulou, N., Adamopoulos, S. N., Degiannis, D., & Kremastinos, D. T. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.09.098 · Cited by 12
The implantable loop recorder: a critical review
Graf, D., Pascale, P., Pruvot, E., & Iglesias, F. (2009) · Kardiovask Med · doi:10.4414/cvm.2009.01406 · Cited by 12
Brembilla-Perrot, B., Beurrier, D., Houriez, P., Nippert, M., Chaise, A. T. D. L., Louis, P., Khaldi, E., Miljoen, H., Andronache, M., Djaballah, K., et al. (2004) · International Journal of Cardiology · doi:10.1016/j.ijcard.2003.06.021 · Cited by 12
Kusumoto, F. M., & Goldschlager, N. (2006) · Clinical Cardiology · doi:10.1002/clc.4960290603 · Cited by 12
Tilt Table Testing and Implantable Loop Recorders for Syncope
Sheldon, R. S. (2012) · Cardiology Clinics · doi:10.1016/j.ccl.2012.10.009 · Cited by 11
Shenthar, J., Prabhu, M. A., Banavalikar, B., Benditt, D. G., & Padmanabhan, D. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2019.01.021 · Cited by 12
de Cardiología, G. D. T. D. L. S. E. (2005) · Revista Española de Cardiología · doi:10.1157/13071892 · Cited by 11
The Value of Tilt Testing and Autonomic Nervous System Assessment
Sutton, R. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.003 · Cited by 10
The Implantable Loop Recorder: Current Uses, Future Directions
Kanjwal, K., Figueredo, V. M., Karabin, B. L., & Grubb, B. P. (2011) · Cited by 10
The ACCF/AHA Scientific Statement on Syncope: a document in need of thoughtful revision
Benditt, D. G. (2006) · EP Europace · doi:10.1093/europace/eul134 · Cited by 9
Loop recorders for syncope evaluation: what is the evidence?
Cheung, C. C., & Krahn, A. D. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1243463 · Cited by 9
Value of Ambulatory Electrocardiographic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.004 · Cited by 9
Guía de práctica clínica para el diagnóstico y manejo del síncope (versión 2009)
Moya‐Mitjans, À., Sutton, R., Ammirati, F., Blanc, J., Brignole, M., Dahm, J. B., Deharo, J., Gajek, J. J., Gjesdal, K., Krahn, A. D., et al. (2009) · Revista Española de Cardiología · doi:10.1016/s0300-8932(09)73132-x · Cited by 23
Tachyarrhythmias in congenital heart disease
Pascual, J. F., Mallofré, N., Santos‐Ortega, A., & Rivas‐Gándara, N. (2024) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2024.1395210 · Cited by 9
Pronóstico del presíncope en pacientes con cardiopatía estructural
Reverte, J. G., Lázaro, C. L., Garcı́a-Alberola, A., Zapata, M. G., García, R. G., Sánchez-Muñoz, J.-J., Sánchez, J. M., & Chávarri, M. V. (2004) · Revista Española de Cardiología · doi:10.1016/s0300-8932(04)77163-8 · Cited by 8
Single center experience in Japanese patients with syncope
Onuki, T., Ito, H., Ochi, A., Chiba, Y., Kawasaki, S., Onishi, Y., Munetsugu, Y., Kikuchi, M., Minoura, Y., Watanabe, N., et al. (2015) · Journal of Cardiology · doi:10.1016/j.jjcc.2014.12.009 · Cited by 9
Sardu, C., Marfella, R., Testa, G., Santamaria, M., Sacra, C., Ranauro, A., Paolisso, G., Rizzo, M. R., & Barbieri, M. (2018) · Medicine · doi:10.1097/md.0000000000011757 · Cited by 8
Kirsch, P., Mitro, P., Mudráková, K., & Valočík, G. (2007) · Bratislavské lekárske listy/Bratislava medical journal · doi:10.1007/bf03656978 · Cited by 8
Benditt, D. G., Ermiş, C., Pham, S., Hiltner, L., Vrudney, A., Lurie, K. G., & Sakaguchi, S. (2003) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1026220020639 · Cited by 8
Outcome of patients with syncope beyond the implantable loop recorder
Merlos, P., Rúmiz, E., Ruiz‐Granell, R., Martínez, A., Izquierdo, M., Ferrero, A., Domínguez, E., Sanchez, J. M., Morell, S., & García–Civera, R. (2012) · EP Europace · doi:10.1093/europace/eus264 · Cited by 8
Implantable Loop Recorders—Syncope, Cryptogenic Stroke, Atrial Fibrillation
Mittal, S. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.04.006 · Cited by 7
Jhanjee, R., Can, I., & Benditt, D. G. (2009) · Disease-a-Month · doi:10.1016/j.disamonth.2009.04.004 · Cited by 7
Metadata
- Authors
- Menozzi, C., Brignole, M., Garcia-Civera, R., Moya, A., Botto, G., Tercedor, L., Migliorini, R., & Navarro, X.
- Affiliations
- Hospital Clínico Universitario de Valencia (ES)
- From the Department of Cardiology, Ospedale S. Maria Nuova (C.M.), Reggio Emilia; Ospedali del Tigullio (M.B.), Lavagna; Ospedale S. Anna (G.B.), Como; and Medtronic Italy (R.M.), Milan, Italy; and Hospital General Vall d’Hebron (A.M.), Barcelona; Hospital Clinico Universitario (R.G.C.), Valencia; Hospital Virgen de las Nieves (L.T.), Granada; and Medtronic Iberica (X.N.), Madrid, Spain.
- Corresponding author
- Brignole, Michele
- Venue
- Circulation
- Published
- 2002-06-11
- Volume
- 105
- Issue
- 23
- Pages
- 2741-2745
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2153070746
- Cited by
- 204
- References
- 22
- Citations by year
- 2026: 2 · 2024: 4 · 2023: 3 · 2021: 4 · 2020: 5 · 2019: 3 · 2018: 6 · 2017: 6 · 2016: 4 · 2015: 5 · 2014: 13 · 2013: 17 · 2012: 9
- FWCI
- 12.09
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- syncope, structural heart disease, implantable loop recorder, ventricular tachyarrhythmia, atrial fibrillation, sinus arrest, atrioventricular block, presyncope, ventricular tachycardia, cardiomyopathy, myocardial infarction, syncope recurrence
- MeSH terms
- Aged, Arrhythmias, Cardiac, Electrocardiography, Female, Follow-Up Studies, Humans, Male, Cardiomyopathies, Syncope, Disease-Free Survival, Prostheses and Implants, Electrophysiologic Techniques, Cardiac, Endpoint Determination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review