Initial Experience With Remote Catheter Ablation Using a Novel Magnetic Navigation System: Magnetic Remote Catheter Ablation
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background— Catheters are typically stiff and incorporate a pull-wire mechanism to allow tip deflection. While standing at the patient’s side, the operator manually navigates the catheter in the heart using fluoroscopic guidance. Methods and Results— A total of 42 patients (32 female; mean age, 55±15 years) underwent ablation of common-type (slow/fast) or uncommon-type (slow/slow) atrioventricular nodal reentrant tachycardia (AVNRT) with the use of the magnetic navigation system Niobe (Stereotaxis, Inc). It consists of 2 computer-controlled permanent magnets located on opposite sides of the patient, which create a steerable external magnetic field (0.08 T). A small magnet embedded in the catheter tip causes the catheter to align and to be steered by the external magnetic field. A motor drive advances or retracts the catheter, enabling complete remote navigation. Radiofrequency current was applied with the use of a remote-controlled 4-mm, solid-tip, magnetic navigation–enabled catheter (55°C, maximum 40 W, 60 seconds) in all patients. The investigators, who were situated in the control room, performed the ablation using a mean of 7.2±4.7 radiofrequency current applications (mean fluoroscopy time, 8.9±6.2 minutes; procedure duration, 145±43 minutes). Slow pathway ablation was achieved in 15 patients, whereas slow pathway modulation was the end point in the remaining patients. There were no complications. Conclusions— The Niobe magnetic navigation system is a new platform technology allowing remote-controlled navigation of an ablation catheter. In conjunction with a motor drive unit, this system was used successfully to perform completely remote-controlled mapping and ablation in patients with AVNRT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jackman, W. M., Beckman, K. J., McClelland, J. H., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199207303270504 · Cited by 1,160
Haissaguerre, M., Gaita, F., Fischer, B., Commenges, D., Montserrat, P., d'Ivernois, C., Lemetayer, P., & Warin, J. F. (1992) · Circulation · doi:10.1161/01.cir.85.6.2162 · Cited by 607
Jazayeri, M. R., Hempe, S. L., Sra, J. S., Dhala, A. A., Blanck, Z., Deshpande, S. S., Avitall, B., Krum, D. P., Gilbert, C. J., & Akhtar, M. (1992) · Circulation · doi:10.1161/01.cir.85.4.1318 · Cited by 489
Kay, G. N., Epstein, A. E., Dailey, S. M., & Plumb, V. J. (1992) · Circulation · doi:10.1161/01.cir.85.5.1675 · Cited by 352
Novel, Magnetically Guided Catheter for Endocardial Mapping and Radiofrequency Catheter Ablation
Faddis, M. N., Blume, W., Finney, J., Hall, A., Rauch, J., Sell, J., Bae, K. T., Talcott, M., & Lindsay, B. (2002) · Circulation · doi:10.1161/01.cir.0000038704.84304.6f · Cited by 280
Experimental study of the magnetic stereotaxis system for catheter manipulation within the brain
Grady, M. S., Howard, M. A., Dacey, R. G., Blume, W., Lawson, M. A., Werp, P. R., & Ritter, R. C. (2000) · Journal of neurosurgery · doi:10.3171/jns.2000.93.2.0282 · Cited by 73
Erdogan, A., Schulte, B., Carlsson, J., Sperzel, J., Güttler, N., Berkowitsch, A., Pitschner, H. F., & Neuzner, J. (2001) · Medizinische Klinik - Intensivmedizin und Notfallmedizin · doi:10.1007/pl00002166 · Cited by 8
Cited by
Percutaneous Recanalization of Chronically Occluded Coronary Arteries: A Consensus Document: Part II
Stone, G. W., Reifart, N. J., Moussa, I., Hoye, A., Cox, D. A., Colombo, A., Baim, D. S., Teirstein, P. S., Strauss, B. H., Selmon, M., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.583716 · Cited by 562
Robotic Magnetic Navigation for Atrial Fibrillation Ablation
Pappone, C., Vicedomini, G., Manguso, F., Gugliotta, F., Mazzone, P., Gulletta, S., Sora, N., Sala, S., Marzi, A., Augello, G., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.058 · Cited by 402
Abbott, J. J., Diller, E., & Petruska, A. J. (2020) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-081219-082713 · Cited by 355
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review
Rafii-Tari, H., Payne, C. J., & Yang, G.-Z. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0946-8 · Cited by 288
Atrial Fibrillation Ablation Using a Robotic Catheter Remote Control System
Saliba, W., Reddy, V. Y., Wazni, O., Cummings, J. E., Burkhardt, J. D., Haissaguerre, M., Kautzner, J., Peichl, P., Neuzil, P., Schibgilla, V., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.03.027 · Cited by 275
Cheng, K., Li, T.-S., Malliaras, K., Davis, D. R., Zhang, Y., & Marbán, E. (2010) · Circulation Research · doi:10.1161/circresaha.109.212589 · Cited by 242
From Passive Tool Holders to Microsurgeons: Safer, Smaller, Smarter Surgical Robots
Bergeles, C., & Yang, G.-Z. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2293815 · Cited by 215
JCS/JHRS 2019 Guideline on Non-Pharmacotherapy of Cardiac Arrhythmias
Nogami, A., Kurita, T., Abe, H., Ando, K., Ishikawa, T., Imai, K., Usui, A., Okishige, K., Kusano, K., Kumagai, K., et al. (2021) · Circulation Journal · doi:10.1253/circj.cj-20-0637 · Cited by 200
Self-citationMagnetic control of continuum devices
Edelmann, J., Petruska, A. J., & Nelson, B. J. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364916683443 · Cited by 194
“The model is also directly adaptable to magnetic systems that use moving permanent magnets to generate the manipulation field (e.g. Ciuti et al., 2010; Ernst et al., 2004; Mahoney and Abbott, 2016).”
BackgroundMethodMagnetic Continuum Device with Variable Stiffness for Minimally Invasive Surgery
Chautems, C., Tonazzini, A., Boehler, Q., Jeong, S. H., Floreano, D., & Nelson, B. J. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.201900086 · Cited by 193
The Art of War: Innate and adaptive immune responses
Dempsey, P. W., Vaidya, S. A., & Cheng, G. (2003) · Cellular and Molecular Life Sciences CMLS · doi:10.1007/s00018-003-3180-y · Cited by 190
Remote-Control Percutaneous Coronary Interventions
Beyar, R., Gruberg, L., Deleanu, D., Roguin, A., Almagor, Y., Cohen, S., Kumar, G., & Wenderow, T. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.024 · Cited by 186
“Remote-control magnetically driven manipulation of catheters was recently applied to electrophysiologic procedures as well as to coronary wire navigation (15).”
Steerable catheters for minimally invasive surgery: a review and future directions
Hu, X., Chen, A., Luo, Y., Zhang, C., & Zhang, E. (2018) · Computer Assisted Surgery · doi:10.1080/24699322.2018.1526972 · Cited by 184
“NiobeVR ES magnetic navigation system is designed to make the treatment of complex cardiac arrhythmias safe and effective (Figure 10) (Stereotaxis 2016), [54].”
BackgroundMethodHwang, J., Kim, J.-Y., & Choi, H. (2020) · Intelligent Service Robotics · doi:10.1007/s11370-020-00311-0 · Cited by 181
JCS/JHRS 2019 guideline on non‐pharmacotherapy of cardiac arrhythmias
Nogami, A., Kurita, T., Abe, H., Ando, K., Ishikawa, T., Imai, K., Usui, A., Okishige, K., Kusano, K., Kumagai, K., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12491 · Cited by 164
Self-citationDI BIASE, L., NATALE, A., BARRETT, C., TAN, C., ELAYI, C. S., CHING, C. K., WANG, P., AL‐AHMAD, A., ARRUDA, M., BURKHARDT, J. D., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01355.x · Cited by 163
Di Biase, L., Fahmy, T. S., Patel, D., Bai, R., Civello, K., Wazni, O. M., Kanj, M., Elayi, C. S., Ching, C. K., Khan, M., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.05.023 · Cited by 158
“The emote MN system consists of 2 focused-field permanent agnets of a neodymium-iron-boron compound that are omputer controlled inside a fixing housing and located on ither side of the body (1,7).”
BackgroundBridging noninvasive and interventional electroanatomical imaging: role of magnetocardiography
Fenici, R., & Brisinda, D. (2007) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2006.10.032 · Cited by 17
From 3D to 4D imaging: is that useful for interventional cardiac electrophysiology?
Fenici, R., & Brisinda, D. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353714 · Cited by 10
Fenici, R., & Brisinda, D. (2007) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-72907-5_24 · Cited by 6
Metadata
- Authors
- Ernst, S., Ouyang, F., Linder, C., Hertting, K., Stahl, F., Chun, J., Hachiya, H., Bänsch, D., Antz, M., & Kuck, K.-H.
- Venue
- Circulation
- Published
- 2004-03-30
- Volume
- 109
- Issue
- 12
- Pages
- 1472-1475
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2079011887
- Cited by
- 353
- References
- 7
- FWCI
- 14.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.