Identification of the Ventricular Tachycardia Isthmus After Infarction by Pace Mapping
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Background— Ventricular tachycardia (VT) isthmuses can be defined by fixed or functional block. During sinus rhythm, pace mapping near the exit of an isthmus should produce a QRS similar to that of VT. Pace mapping at sites proximal to the exit may produce a similar QRS with a longer stimulus-to-QRS interval (S-QRS). The aim of the study was to determine whether a VT isthmus could be identified and followed by pace mapping. Methods and Results— Left ventricular pace mapping during sinus rhythm was performed at 819 sites in 11 patients with VT late after infarction, and corresponding CARTO maps were reconstructed. An isthmus site was defined by entrainment and/or VT termination by ablation. Pace-mapping data were analyzed from the identified isthmus site and from sites at progressively increasing distances from this initial isthmus site. Sites where pace mapping produced the same QRS with different S-QRS delays were identified to attempt to trace the course of the isthmus. In 11 patients, 13 confluent low-voltage infarct regions were present. In all these regions, parts of VT isthmuses were identified by pace mapping. In 11 of 13 of the identified isthmus parts, the QRS morphology of the pace map matched a VT QRS. In 10 of 11 patients, radiofrequency ablation rendered clinical VTs noninducible. Successful ablation sites were localized within an isthmus identified by pace mapping in all of these 10 patients. Conclusions— VT isthmuses can be identified and part of their course delineated by pace mapping during sinus rhythm. This method could help target isthmus sites for ablation during stable sinus rhythm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marchlinski, F. E., Callans, D. J., Gottlieb, C. D., & Zado, E. (2000) · Circulation · doi:10.1161/01.cir.101.11.1288 · Cited by 1,220
Slow conduction in the infarcted human heart. 'Zigzag' course of activation.
de Bakker, J. M., van Capelle, F. J., Janse, M. J., Tasseron, S., Vermeulen, J. T., de Jonge, N., & Lahpor, J. R. (1993) · Circulation · doi:10.1161/01.cir.88.3.915 · Cited by 842
de Bakker, J. M., van Capelle, F. J., Janse, M. J., Wilde, A. A., Coronel, R., Becker, A. E., Dingemans, K. P., van Hemel, N. M., & Hauer, R. N. (1988) · Circulation · doi:10.1161/01.cir.77.3.589 · Cited by 789
Soejima, K., Suzuki, M., Maisel, W. H., Brunckhorst, C. B., Delacretaz, E., Blier, L., Tung, S., Khan, H., & Stevenson, W. G. (2001) · Circulation · doi:10.1161/hc3101.093764 · Cited by 409
Self-citationExploring Postinfarction Reentrant Ventricular Tachycardia With Entrainment Mapping
Stevenson, W. G., Friedman, P. L., Sager, P. T., Saxon, L. A., Kocovic, D., Harada, T., Wiener, I., & Khan, H. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00065-x · Cited by 386 · cited 1×
“5 For analysis, any of the following criteria defined an isthmus site;3 (1) pacing at the site entrained VT with concealed fusion, with an S-QRS 70% of the VT cycle length and either an S-QRS that matched the electrogram QRS ( 20 ms) or a postpacing interval tachycardia cycle-length difference 30 ms; (2) RF current ap…”
MethodSelf-citationNonfluoroscopic, in vivo navigation and mapping technology
Ben-Haim, S. A., Osadchy, D., Scnuster, I., Gepstein, L., Hayam, G., & Josephson, M. E. (1996) · Nature Medicine · doi:10.1038/nm1296-1393 · Cited by 370
Josephson, M. E., Waxman, H. L., CAIN, M. E., Gardner, M. J., & Buxton, A. E. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)90003-0 · Cited by 229
Stevenson, W. G., Sager, P. T., Natterson, P. D., Saxon, L. A., Middlekauff, H. R., & Wiener, I. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)80026-d · Cited by 199
Self-citationEntrainment Techniques for Mapping Atrial and Ventricular Tachycardias
Stevenson, W. G., Sager, P. T., & FRIEDMAN, P. L. (1995) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1995.tb00771.x · Cited by 156
Self-citationVirtual cathode effects during stimulation of cardiac muscle. Two-dimensional in vivo experiments.
Wikswo, J. P., Wisialowski, T. A., Altemeier, W. A., Balser, J. R., Kopelman, H. A., & Roden, D. M. (1991) · Circulation Research · doi:10.1161/01.res.68.2.513 · Cited by 124
Cited by
Schmidt, A., Azevedo, C. F., Cheng, A., Gupta, S. N., Bluemke, D. A., Foo, T. K., Gerstenblith, G., Weiss, R. G., Marbán, E., Tomaselli, G. F., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.653568 · Cited by 823
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citationAliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Bella, P. D., Hindricks, G., Jais, P., Josephson, M. E., et al. (2009) · Europace · doi:10.1093/europace/eup098 · Cited by 416
Self-citationCatheter Ablation for Ventricular Tachycardia
Stevenson, W. G., & Soejima, K. (2007) · Circulation · doi:10.1161/circulationaha.106.655720 · Cited by 299
Self-citationSubstrate Mapping for Ventricular Tachycardia
Josephson, M. E., & Anter, E. (2015) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2015.09.001 · Cited by 221
JCS/JHRS 2019 Guideline on Non-Pharmacotherapy of Cardiac Arrhythmias
Nogami, A., Kurita, T., Abe, H., Ando, K., Ishikawa, T., Imai, K., Usui, A., Okishige, K., Kusano, K., Kumagai, K., et al. (2021) · Circulation Journal · doi:10.1253/circj.cj-20-0637 · Cited by 200
Self-citationTzou, W. S., Frankel, D. S., Hegeman, T., Supple, G. E., Garcia, F. C., Santangeli, P., Katz, D. F., Sauer, W. H., & Marchlinski, F. E. (2015) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.114.002310 · Cited by 190
“Potential isthmus or exit sites were identified by pacemapping, as previously defined: long stimulus-QRS times (>40 ms) and ≥1 of the following: (1) ≥10 of 12 morphology match to clinical or induced VTs; (2) overall paced QRS vector concordance with clinical or induced VTs (based on bundle branch morphology in V1, fro…”
Backgroundde Chillou, C., Groben, L., Magnin-Poull, I., Andronache, M., Abbas, M. M., Zhang, N., Abdelaal, A., Ammar, S., Sellal, J.-M., Schwartz, J., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2013.10.042 · Cited by 178
Sasano, T., Abraham, M. R., Chang, K.-C., Ashikaga, H., Mills, K. J., Holt, D. P., Hilton, J., Nekolla, S. G., Dong, J., Lardo, A. C., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.062 · Cited by 176
Ventricular Tachycardia Ablation: Evolution of Patients and Procedures Over 8 Years
Sacher, F., Tedrow, U. B., Field, M. E., Raymond, J.-M., Koplan, B. A., Epstein, L. M., & Stevenson, W. G. (2008) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.769471 · Cited by 166
Self-citationJCS/JHRS 2019 guideline on non‐pharmacotherapy of cardiac arrhythmias
Nogami, A., Kurita, T., Abe, H., Ando, K., Ishikawa, T., Imai, K., Usui, A., Okishige, K., Kusano, K., Kumagai, K., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12491 · Cited by 164
Self-citationAblating Premature Ventricular Complexes: Justification, Techniques, and Outcomes
Noheria, A., Deshmukh, A., & Asirvatham, S. J. (2015) · Methodist DeBakey Cardiovascular Journal · doi:10.14797/mdcj-11-2-109 · Cited by 54
Metadata
- Authors
- Brunckhorst, C. B., Delacretaz, E., Soejima, K., Maisel, W. H., Friedman, P. L., & Stevenson, W. G.
- Venue
- Circulation
- Published
- 2004-08-10
- Volume
- 110
- Issue
- 6
- Pages
- 652-659
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2156711379
- Cited by
- 179
- References
- 14
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.