Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 256

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Electroanatomic Substrate and Outcome of Catheter Ablative Therapy for Ventricular Tachycardia in Setting of Right Ventricular Cardiomyopathy

Marchlinski, Francis E., Zado, Erica, Dixit, Sanjay, Gerstenfeld, Edward, Callans, David J., Hsia, Henry, Lin, David, Nayak, Hemal, Russo, Andrea, Pulliam, Ward·2004·Circulation

Abstract

Background— To gain insight into the pathogenesis of right ventricular (RV) cardiomyopathy and ventricular tachycardia (VT), we determined the clinical and electroanatomic characteristics and outcome of ablative therapy in consecutive patients with (1) RV dilatation, (2) multiple left bundle-branch block (LBBB)–type VTs, and (3) an abnormal endocardial substrate defined by contiguous electrogram abnormalities. Methods and Results— All 21 patients had detailed RV bipolar electrogram voltage mapping. Eighteen patients had simultaneous left ventricular (LV) mapping, including all 4 patients with right bundle-branch block (RBBB) VT. VT was ablated in 19 patients by use of focal and/or linear lesions with irrigated-tip catheters in 10 of 19 patients. Eighteen patients were men, age 47±18 years, and none had a family history of RV dysplasia. RV volume was 223±89 cm 3 . Electrogram abnormalities extended from perivalvular tricuspid valves (5 patients), pulmonic valves (6 patients), or both valves (10 patients). Electrogram abnormalities always involved free wall, spared the apex, and included the septum in 15 patients (71%). The area of abnormality was 55±37 cm 2 (range, 12 to 130 cm 2 ) and represented 34±19% of the RV. In 52 of 66 LBBB VTs, the origin was from the RV perivalvular region. LV perivalvular low-voltage areas noted in 5 patients were associated with a RBBB VT origin. No VT recurred after ablation in 17 patients (89%) during 27±22 months. Conclusions— In patients with RV cardiomyopathy and VT, (1) perivalvular electrogram abnormalities represent the commonly identified substrate and source of most VT, (2) LV perivalvular endocardial electrogram abnormalities and VT can occasionally be identified, and (3) aggressive ablative therapy provides long-term VT control.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000145154.02436.90

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 256

Metadata

Authors
Marchlinski, F. E., Zado, E., Dixit, S., Gerstenfeld, E., Callans, D. J., Hsia, H., Lin, D., Nayak, H., Russo, A., & Pulliam, W.
Venue
Circulation
Published
2004-10-19
Volume
110
Issue
16
Pages
2293-2298
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2161802699
Cited by
256
References
15
FWCI
5.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electroanatomic Substrate and Outcome of Catheter Ablative Therapy for Ventricular Tachycardia in Setting of Right Ventricular Cardiomyopathy. https://app.cochat.ai/papers/10.1161/01.cir.0000145154.02436.90
The paper
Marchlinski, F. E., Zado, E., Dixit, S., Gerstenfeld, E., Callans, D. J., Hsia, H., Lin, D., Nayak, H., Russo, A., & Pulliam, W. (2004). Electroanatomic Substrate and Outcome of Catheter Ablative Therapy for Ventricular Tachycardia in Setting of Right Ventricular Cardiomyopathy. Circulation. https://doi.org/10.1161/01.cir.0000145154.02436.90

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.