The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Intravascular Ultrasound: Novel Pathophysiological Insights and Current Clinical Applications
Open accessAbstract
Abstract —Intravascular ultrasound (IVUS) is a valuable adjunct to angiography, providing new insights in the diagnosis of and therapy for coronary disease. Angiography depicts only a 2D silhouette of the lumen, whereas IVUS allows tomographic assessment of lumen area, plaque size, distribution, and composition. The safety of IVUS is well documented, and the assessment of luminal dimensions represents an important application of this modality. Comparative studies show the greatest disparities between angiography and ultrasound after mechanical interventions. In young subjects, normal intimal thickness is typically ≈0.15 mm. With IVUS, lipid-laden lesions appear hypoechoic, fibromuscular lesions generate low-intensity echoes, and fibrous or calcified tissues are echogenic. Calcium obscures the underlying wall (acoustic shadowing). The extent and severity of disease by angiography and ultrasound are frequently discrepant. Arterial remodeling refers to changes in vascular dimensions during the development of atherosclerosis. At diseased sites, the external elastic membrane may actually shrink in size, contributing to luminal stenosis. The interpretation of IVUS relies on simple visual inspection of acoustic reflections to determine plaque composition. However, different tissue components may look quite similar, and artifacts may adversely affect ultrasound images. IVUS commonly detects occult disease in angiographically “normal” sites. In ambiguous lesions, ultrasound permits lesion quantification, particularly for left main coronary disease. IVUS has emerged as the optimal method for the detection of transplant vasculopathy. An important potential application of ultrasound is the identification of atheromas at risk of rupture. The mechanisms of action of interventional devices have been elucidated using IVUS, and ultrasound is used by some operators to select the most suitable interventional device. IVUS-derived residual plaque burden is the most useful predictor of clinical outcome. In restenosis after balloon angioplasty, negative remodeling is a major mechanism of late lumen loss. IVUS is not routinely used for stent optimization, and there is no consensus regarding optimal procedural end points. Ultrasound has proven useful in evaluating brachytherapy. New and emerging applications for IVUS are continuing to evolve, particularly in atherosclerosis regression-progression trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Compensatory Enlargement of Human Atherosclerotic Coronary Arteries
Glagov, S., Weisenberg, E., Zarins, C. K., Stankunavicius, R., & Kolettis, G. J. (1987) · New England Journal of Medicine · doi:10.1056/nejm198705283162204 · Cited by 3,623
Little, W. C., Constantinescu, M., Applegate, R. J., Kutcher, M. A., Burrows, M. T., Kahl, F. R., & Santamore, W. P. (1988) · Circulation · doi:10.1161/01.cir.78.5.1157 · Cited by 1,474
Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
Patterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247
Topol, E. J., & Nissen, S. E. (1995) · Circulation · doi:10.1161/01.cir.92.8.2333 · Cited by 1,103
Self-citationArterial Remodeling After Coronary Angioplasty: A Serial Intravascular Ultrasound Study
Mintz, G. S., Popma, J. J., Pichard, A. D., Kent, K. M., Satler, L. F., Chiu Wong, S., Hong, M. K., Kovach, J. A., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.1.35 · Cited by 889
Interobserver variability in coronary angiography.
Zir, L. M., Miller, S. W., Dinsmore, R. E., Gilbert, J. P., & Harthorne, J. W. (1976) · Circulation · doi:10.1161/01.cir.53.4.627 · Cited by 768
Schoenhagen, P., Ziada, K. M., Kapadia, S. R., Crowe, T. D., Nissen, S. E., & Tuzcu, E. M. (2000) · Circulation · doi:10.1161/01.cir.101.6.598 · Cited by 753
Self-citationNissen, S. E., Gurley, J. C., Grines, C. L., Booth, D. C., McClure, R., Berk, M., Fischer, C., & DeMaria, A. N. (1991) · Circulation · doi:10.1161/01.cir.84.3.1087 · Cited by 667
Self-citationARNETT, E. N., ISNER, J. M., REDWOOD, D. R., KENT, K. M., BAKER, W. P., ACKERSTEIN, H., & ROBERTS, W. C. (1979) · Annals of Internal Medicine · doi:10.7326/0003-4819-91-3-350 · Cited by 628
Arterial wall characteristics determined by intravascular ultrasound imaging: An in vitro study
Gussenhoven, E. J., Essed, C. E., Lancée, C. T., Mastik, F., Frietman, P., van Egmond, F. C., Reiber, J., Bosch, H., van Urk, H., Roelandt, J., et al. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90471-3 · Cited by 613
Tobis, J. M., Mallery, J., Mahon, D. J., et al. (1991) · Circulation · doi:10.1161/01.cir.83.3.913 · Cited by 600
Mintz, G. S., Painter, J. A., Pichard, A. D., Kent, K. M., Satler, L. F., Popma, J. J., Chuang, Y. C., Bucher, T. A., Sokolowicz, L. E., & Leon, M. B. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00088-l · Cited by 592
Uretsky, B. F., Murali, S., Reddy, P. S., Rabin, B., Lee, A., Griffith, B. P., Hardesty, R. L., Trento, A., & Bahnson, H. T. (1987) · Circulation · doi:10.1161/01.cir.76.4.827 · Cited by 531
Gao, S.-Z., Alderman, E. L., Schroeder, J. S., Silverman, J. F., & Hunt, S. A. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90402-0 · Cited by 499
Correlation of the Antemortem Coronary Arteriogram and the Postmortem Specimen
VLODAVER, Z., FRECH, R., VAN TASSEL, R. A., & EDWARDS, J. E. (1973) · Circulation · doi:10.1161/01.cir.47.1.162 · Cited by 395
Hodgson, J. M., Reddy, K. G., Suneja, R., Nair, R. N., Lesnefsky, E. J., & Sheehan, H. M. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90714-c · Cited by 359
GRONDIN, C. M., DYRDA, I., PASTERNAC, A., CAMPEAU, L., BOURASSA, M. G., & LESPÉRANCE, J. (1974) · Circulation · doi:10.1161/01.cir.49.4.703 · Cited by 341
Mintz, G. S., Kent, K. M., Pichard, A. D., Satler, L. F., Popma, J. J., & Leon, M. B. (1997) · Circulation · doi:10.1161/01.cir.95.7.1791 · Cited by 319
Waller, B. F. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90248-9 · Cited by 318
Nissen, S. E., Grines, C. L., Gurley, J. C., Sublett, K., Haynie, D., Diaz, C., Booth, D. C., & DeMaria, A. N. (1990) · Circulation · doi:10.1161/01.cir.81.2.660 · Cited by 293
Self-citationPasterkamp, G., Wensing, P. J. W., Post, M. J., Hillen, B., Mali, W. P. T. M., & Borst, C. (1995) · Circulation · doi:10.1161/01.cir.91.5.1444 · Cited by 281
Isner, J. M., Kishel, J., Kent, K. M., Ronan, J. A., Ross, A. M., & Roberts, W. C. (1981) · Circulation · doi:10.1161/01.cir.63.5.1056 · Cited by 262
In vivo validation of compensatory enlargement of atherosclerotic coronary arteries
Hermiller, J. B., Tenaglia, A. N., Kisslo, K. B., Phillips, H. R., Bashore, T. M., Stack, R. S., & Davidson, C. J. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)91007-5 · Cited by 252
Intravascular ultrasound imaging of coronary arteries. Is three layers the norm?
Fitzgerald, P. J., St Goar, F. G., Connolly, A. J., Pinto, F. J., Billingham, M. E., Popp, R. L., & Yock, P. G. (1992) · Circulation · doi:10.1161/01.cir.86.1.154 · Cited by 244
Self-citationLosordo, D. W., Rosenfield, K., Kaufman, J., Pieczek, A., & Isner, J. M. (1994) · Circulation · doi:10.1161/01.cir.89.6.2570 · Cited by 240
Quantitation of coronary arterial narrowing at necropsy in sudden coronary death
Roberts, W. C., & Jones, A. A. (1979) · The American Journal of Cardiology · doi:10.1016/0002-9149(79)90248-0 · Cited by 230
Histopathologic validation of angioscopy and intravascular ultrasound.
Siegel, R. J., Ariani, M., Fishbein, M. C., Chae, J. S., Park, J. C., Maurer, G., & Forrester, J. S. (1991) · Circulation · doi:10.1161/01.cir.84.1.109 · Cited by 223
Stark, R. P., McGinn, A. L., & Wilson, R. F. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106203242507 · Cited by 222
Insensitivity of noninvasive tests to detect coronary artery vasculopathy after heart transplant
Smart, F. W., Ballantyne, C. M., Cocanougher, B., Farmer, J. A., Sekela, M. E., Noon, G. P., & Young, J. B. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90553-w · Cited by 204
Mintz, G. S., Popma, J. J., Pichard, A. D., Kent, K. M., Satler, L. F., Chien Chuang, Y., DeFalco, R. A., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.93.5.924 · Cited by 193
Goar, F. G. S., Pinto, F. J., Alderman, E. L., Fitzgerald, P. J., Stadius, M. L., & Popp, R. L. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90753-v · Cited by 183
How does angioplasty work? Serial analysis of human iliac arteries using intravascular ultrasound.
Losordo, D. W., Rosenfield, K., Pieczek, A., et al. (1992) · Circulation · doi:10.1161/01.cir.86.6.1845 · Cited by 153
Mintz, G. S., Pichard, A. D., Kovach, J. A., Kent, K. M., Satler, L. F., Javier, S. P., Popma, J. J., & Leon, M. B. (1994) · The American Journal of Cardiology · doi:10.1016/0002-9149(94)90670-x · Cited by 148
Target lesion calcification in coronary artery disease: An intravascular ultrasound study
Mintz, G. S., Douek, P., Pichard, A. D., Kent, K. M., Satler, L. F., Popma, J. J., & Leon, M. B. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90371-s · Cited by 146
The dilemma of diagnosing coronary calcification: Angiography versus intravascular ultrasound
Tuzcu, E. M., Berkalp, B., Franco, A. C. D., Ellis, S. G., Goormastic, M., Whitlow, P. L., Franco, I., Raymond, R. E., & Nissen, S. E. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00537-4 · Cited by 142
Self-citationPeters, R. J. G., Kok, W. E. M., Mario, C. D., Serruys, P. W. J. C., Bär, F. W. H. M., Pasterkamp, G., Borst, C., Kamp, O., Bronzwaer, J. G. F., Visser, C. A., et al. (1997) · Circulation · doi:10.1161/01.cir.95.9.2254 · Cited by 75
Cited by
Naghavi, M., Libby, P., Falk, E., Casscells, S. W., Litovsky, S., Rumberger, J., Badimon, J. J., Stefanadis, C., Moreno, P., Pasterkamp, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000087481.55887.c9 · Cited by 2,668
Nissen, S. E., Tuzcu, E. M., Schoenhagen, P., Brown, B. G., Ganz, P., Vogel, R. A., Crowe, T., Howard, G., Cooper, C. J., Brodie, B., et al. (2004) · JAMA · doi:10.1001/jama.291.9.1071 · Cited by 2,361
Self-citationNissen, S. E., Tsunoda, T., Tuzcu, E. M., Schoenhagen, P., Cooper, C. J., Yasin, M., Eaton, G. M., Lauer, M. A., Sheldon, W. S., Grines, C. L., et al. (2003) · JAMA · doi:10.1001/jama.290.17.2292 · Cited by 1,707
Self-citationStatin Therapy, LDL Cholesterol, C-Reactive Protein, and Coronary Artery Disease
Nissen, S. E., Tuzcu, E. M., Schoenhagen, P., Crowe, T., Sasiela, W. J., Tsai, J., Orazem, J., Magorien, R. D., O'Shaughnessy, C., & Ganz, P. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042000 · Cited by 1,325
Self-citationRioufol, G., Finet, G., Ginon, I., André-Fouët, X., Rossi, R., Vialle, E., Desjoyaux, E., Convert, G., Huret, J. F., & Tabib, A. (2002) · Circulation · doi:10.1161/01.cir.0000025609.13806.31 · Cited by 692
Retracted
Metadata
- Authors
- Nissen, S. E., & Yock, P.
- Venue
- Circulation
- Published
- 2001-01-30
- Volume
- 103
- Issue
- 4
- Pages
- 604-616
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2021609203
- Cited by
- 840
- References
- 37
- FWCI
- 41.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.