The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Transluminal, subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man.
Open accessAbstract
Assessment of coronary blood flow and the vasodilator reserve capacity of individual coronary arteries in the catheterization laboratory has been hampered by methodologic limitations. We have developed and validated a small Doppler catheter that can subselectively measure phasic coronary blood flow velocity (CBFV). In seven anesthetized calves, CBFV was varied from 0.1 to 5.7 times control CBFV. Changes in mean CBFV measured intraluminally by catheter in the left anterior descending and left circumflex arteries were similar to those measured simultaneously with an epicardial Doppler probe on the surface of the same vessel (n = 85, r = .95, slope = 1.04) and to changes in coronary sinus flow (n = 69, r = .97, slope = 1.06) measured with timed venous collections. Identical maximal coronary reactive hyperemic responses with the catheter present and absent in the artery being studied demonstrated that coronary obstruction by the catheter was minimal. Safety studies in six additional calves demonstrated that the catheter caused small changes in coronary endothelial permeability. Histologic studies revealed no endothelial denudation or thrombus formation. Stable phasic recordings of coronary blood flow velocity have been obtained in 58 of 70 patients studied. One of the 70 patients studied had abrupt coronary occlusion probably related to catheter-induced vasospasm. In 10 normal patients, intracoronary meglumine diatrizoate increased CBFV to 3.5 times that at rest (range 2.8 to 5.0). CBFV rose 5.0-fold after an intravenous infusion of dipyridamole (range 3.8 to 7.0). In each patient, dipyridamole produced greater vasodilation than meglumine diatrizoate. The time- and dose-response characteristics to dipyridamole infusion were heterogeneous, underscoring the advantage of continuous on-line measurement of CBFV in the measurement of vasodilator reserve. This method of measuring CBFV and assessing vasodilator reserve in the catheterization laboratory should facilitate studies of the coronary circulation in man.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiologic basis for assessing critical coronary stenosis
Gould, K. L., Lipscomb, K., & Hamilton, G. W. (1974) · The American Journal of Cardiology · doi:10.1016/0002-9149(74)90743-7 · Cited by 1,532
Opherk, D., Mall, G., Zebe, H., Schwarz, F., Weihe, E., Manthey, J., & Kübler, W. (1984) · Circulation · doi:10.1161/01.cir.69.1.1 · Cited by 381
An ultrasonic pulsed Doppler system for measuring blood flow in small vessels.
Hartley, C. J., & Cole, J. S. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.37.4.626 · Cited by 354
Self-citationVentricular function and coronary hemodynamics in hypertensive heart disease
Strauer, B.-E. (1979) · The American Journal of Cardiology · doi:10.1016/0002-9149(79)90235-2 · Cited by 352
Regulation of coronary blood flow
Rubio, R., & Berne, R. M. (1975) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(75)90001-8 · Cited by 251
Brown, B. G., Josephson, M. A., Petersen, R. B., Pierce, C. D., Wong, M., Hecht, H. S., Bolson, E., & Dodge, H. T. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90323-4 · Cited by 227
Klocke, F. J. (1983) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(83)80008-4 · Cited by 152
Coronary sinus reflux. A source of error in the measurement of thermodilution coronary sinus flow.
Mathey, D. G., Chatterjee, K., Tyberg, J. V., et al. (1978) · Circulation · doi:10.1161/01.cir.57.4.778 · Cited by 138
Rowe, G. G., Huston, J. H., Weinstein, A. B., Tuchman, H., Brown, J. F., Crumpton, C. W., Peterson, A., Welch, B., & Fosshage, P. (1956) · Journal of Clinical Investigation · doi:10.1172/jci103273 · Cited by 84
von Restorff, W., Höfling, B., Holtz, J., & Bassenge, E. (1975) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00584541 · Cited by 84
Cited by
Effect of Exercise on Coronary Endothelial Function in Patients with Coronary Artery Disease
Hambrecht, R., Wolf, A., Gielen, S., Linke, A., Hofer, J., Erbs, S., Schoene, N., & Schuler, G. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002173420702 · Cited by 1,340
Pijls, N. H., van Son, J. A., Kirkeeide, R. L., De Bruyne, B., & Gould, K. L. (1993) · Circulation · doi:10.1161/01.cir.87.4.1354 · Cited by 1,183
Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity.
Doucette, J. W., Corl, P. D., Payne, H. M., Flynn, A. E., Goto, M., Nassi, M., & Segal, J. (1992) · Circulation · doi:10.1161/01.cir.85.5.1899 · Cited by 1,016
Effects of adenosine on human coronary arterial circulation.
Wilson, R. F., Wyche, K., Christensen, B. V., Zimmer, S., & Laxson, D. D. (1990) · Circulation · doi:10.1161/01.cir.82.5.1595 · Cited by 906
Self-citationRelation between Myocardial Blood Flow and the Severity of Coronary-Artery Stenosis
Uren, N. G., Melin, J. A., De Bruyne, B., Wijns, W., Baudhuin, T., & Camici, P. G. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406233302503 · Cited by 881
The Effect of Atherosclerosis on the Vasomotor Response of Coronary Arteries to Mental Stress
Yeung, A. C., Vekshtein, V. I., Krantz, D. S., Vita, J. A., Ryan, T. J., Ganz, P., & Selwyn, A. P. (1991) · New England Journal of Medicine · doi:10.1056/nejm199111283252205 · Cited by 599
Hutchins, G. D., Schwaiger, M., Rosenspire, K. C., Krivokapich, J., Schelbert, H., & Kuhl, D. E. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90237-j · Cited by 552
Coronary flow reserve as a physiologic measure of stenosis severity
Gould, K. L., Kirkeeide, R. L., & Buchi, M. (1990) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80078-6 · Cited by 548
Bergmann, S. R., Herrero, P., Markham, J., Weinheimer, C. J., & Walsh, M. N. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90105-8 · Cited by 439
Hozumi, T., Yoshida, K., Akasaka, T., Asami, Y., Ogata, Y., Takagi, T., Kaji, S., Kawamoto, T., Ueda, Y., & Morioka, S. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00389-1 · Cited by 426
Golino, P., Piscione, F., Willerson, J. T., Cappelli-Bigazzi, M., Focaccio, A., Villari, B., Indolfi, C., Russolillo, E., Condorelli, M., & Chiariello, M. (1991) · New England Journal of Medicine · doi:10.1056/nejm199103073241001 · Cited by 426
Maximal Coronary Flow Reserve and Metabolic Coronary Vasodilation in Patients With Diabetes Mellitus
Nahser, P. J., Brown, R. E., Oskarsson, H., Winniford, M. D., & Rossen, J. D. (1995) · Circulation · doi:10.1161/01.cir.91.3.635 · Cited by 425
Atherosclerosis impairs flow-mediated dilation of coronary arteries in humans.
Cox, D. A., Vita, J. A., Treasure, C. B., Fish, R. D., Alexander, R. W., Ganz, P., & Selwyn, A. P. (1989) · Circulation · doi:10.1161/01.cir.80.3.458 · Cited by 414
Acute Effects of Passive Smoking on the Coronary Circulation in Healthy Young Adults
Otsuka, R. (2001) · JAMA · doi:10.1001/jama.286.4.436 · Cited by 410
Hozumi, T., Yoshida, K., Ogata, Y., Akasaka, T., Asami, Y., Takagi, T., & Morioka, S. (1998) · Circulation · doi:10.1161/01.cir.97.16.1557 · Cited by 405
Flow-dependent coronary artery dilatation in humans.
Drexler, H., Zeiher, A. M., Wollschläger, H., Meinertz, T., Just, H., & Bonzel, T. (1989) · Circulation · doi:10.1161/01.cir.80.3.466 · Cited by 334
Houghton, J. L., Frank, M. J., Carr, A. A., von Dohlen, T. W., & Prisant, L. M. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90173-m · Cited by 328
Demer, L. L., Gould, K. L., Goldstein, R. A., Kirkeeide, R. L., Mullani, N. A., Smalling, R. W., Nishikawa, A., & Merhige, M. E. (1989) · Circulation · doi:10.1161/01.cir.79.4.825 · Cited by 316
Iliceto, S., Marangelli, V, Memmola, C., & Rizzon, P. (1991) · Circulation · doi:10.1161/01.cir.83.1.61 · Cited by 294
Krivokapich, J., Smith, G. T., Huang, S. C., Hoffman, E. J., Ratib, O., Phelps, M. E., & Schelbert, H. R. (1989) · Circulation · doi:10.1161/01.cir.80.5.1328 · Cited by 280
Visual estimates of percent diameter coronary stenosis: “A battered gold standard”
Marcus, M. L., Skorton, D. J., Johnson, M. R., Collins, S. M., Harrison, D. G., & Kerber, R. E. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90226-4 · Cited by 262
Self-citationHildick-Smith, D. J. R. (2000) · Heart · doi:10.1136/heart.84.4.383 · Cited by 80
Kyriakidis, M., Triposkiadis, F., Dernellis, J., Androulakis, A. E., Mellas, P., Kelepeshis, G. A., & Gialafos, J. E. (1998) · Circulation · doi:10.1161/01.cir.97.14.1342 · Cited by 42
Uncertainty quantification of simulated biomechanical stimuli in coronary artery bypass grafts
Tran, J. S., Schiavazzi, D. E., Kahn, A. M., & Marsden, A. L. (2019) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2018.10.024 · Cited by 37
Metadata
- Authors
- Wilson, R. F., Laughlin, D. E., Ackell, P. H., Chilian, W. M., Holida, M. D., Hartley, C. J., Armstrong, M. L., Marcus, M. L., & White, C. W.
- Venue
- Circulation
- Published
- 1985-07
- Volume
- 72
- Issue
- 1
- Pages
- 82-92
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2077935074
- Cited by
- 509
- References
- 12
- FWCI
- 23.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.