The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Intracoronary stenting for acute and threatened closure complicating percutaneous transluminal coronary angioplasty.
Open accessAbstract
BACKGROUND. Acute closure remains a significant limitation of percutaneous transluminal coronary angioplasty (PTCA) and underlies the majority of ischemic complications. This study details the clinical and angiographic characteristics of a series of patients receiving an intracoronary stent device to manage acute and threatened closure and presents the early clinical results. METHODS AND RESULTS. From October 1989 through June 1991, 115 patients undergoing PTCA received intracoronary stents to treat acute or threatened closure in 119 vessels. Sixty-three percent had multivessel coronary disease, 33 (29%) had undergone prior coronary artery bypass grafting (CABG), and 52 (45%) had had previous PTCA. Using the American College of Cardiology/American Heart Association (ACC/AHA) classification, 15% of lesions were class A, 55% were class B, and 30% were class C. Eight patients were referred with severe coronary dissection and unstable angina after PTCA at other institutions. Acute closure was defined as occlusion of the vessel with TIMI (Thrombolysis in Myocardial Infarction) 0 or 1 flow immediately before stent placement. Threatened closure required two or more of the following criteria: 1) a residual stenosis greater than 50%, 2) TIMI grade 2 flow, 3) angiographic dissection comprising extraluminal dye extravasation and/or a length of greater than 15 mm, 4) evidence of clinical ischemia (either typical angina or ECG changes). Twelve vessels (10%) met the criteria for acute closure, and 87 vessels (73%) satisfied the criteria for threatened closure. Twenty vessels (17%) failed to meet two criteria. Stenting produced optimal angiographic results in 111 vessels (93%), with mean diameter stenosis (+/- 1 SD) reduced from 83 +/- 12% before to 18 +/- 29% after stenting. Overall, in-hospital mortality was 1.7% and CABG was required in 4.2%; Q wave myocardial infarction (MI) occurred in 7% and non-Q wave MI in 9%. Stent thrombosis occurred in nine patients (7.6%). For the 108 patients who presented to the catheterization laboratory without evolving MI, Q wave MI occurred in 4% and non-Q wave MI occurred in 7%. Angiographic follow-up has been performed in 81 eligible patients (76%), and 34 patients (41%) had a lesion of greater than or equal to 50%. CONCLUSIONS. This stent may be a useful adjunct to balloon dilatation in acute or threatened closure. Randomized studies comparing this stent with alternative technologies are required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines for percutaneous transluminal coronary angioplasty
Ryan, T. J. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90431-7 · Cited by 1,029
Percutaneous Transluminal Coronary Angioplasty in 1985–1986 and 1977–1981
Detre, K., Holubkov, R., Kelsey, S., Cowley, M., Kent, K., Williams, D., Myler, R., Faxon, D., Holmes, D., Bourassa, M., et al. (1988) · New England Journal of Medicine · doi:10.1056/nejm198802043180501 · Cited by 851
Percutaneous coronary angioplasty: Technique, indications, and results
Roubin, G. S., Gruentzig, A. R., & Casarella, W. J. (1986) · CardioVascular and Interventional Radiology · doi:10.1007/bf02577956 · Cited by 26
Self-citationLong-term outcome of unsuccessful percutaneous transluminal coronary angioplasty
Tuzcu, M., Simpfendorfer, C., Dorosti, K., et al. (1990) · American Heart Journal · doi:10.1016/s0002-8703(05)80313-8 · Cited by 18
Cited by
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
Bertrand, M. E., Rupprecht, H.-J., Urban, P., Gershlick, A. H., & Investigators, F. T. C. (2000) · Circulation · doi:10.1161/01.cir.102.6.624 · Cited by 1,010
Antithrombotic Therapy for Atrial Fibrillation
Lip, G. Y. H., Banerjee, A., Boriani, G., Chiang, C. E., Fargo, R., Freedman, B., Lane, D. A., Ruff, C. T., Turakhia, M., Werring, D., et al. (2018) · Chest · doi:10.1016/j.chest.2018.07.040 · Cited by 939
Antithrombotic Therapy for Atrial Fibrillation
You, J. J., Singer, D. E., Howard, P. A., Lane, D. A., Eckman, M. H., Fang, M. C., Hylek, E. M., Schulman, S., Go, A. S., Hughes, M., et al. (2012) · Chest · doi:10.1378/chest.11-2304 · Cited by 918
Serruys, P. W., Kutryk, M. J. B., & Ong, A. T. L. (2006) · New England Journal of Medicine · doi:10.1056/nejmra051091 · Cited by 762
Smith, S. C., Dove, J. T., Jacobs, A. K., Kennedy, J. W., Kereiakes, D., Kern, M. J., Kuntz, R. E., Popma, J. J., Schaff, H. V., Williams, D. O., et al. (2001) · Circulation · doi:10.1161/01.cir.103.24.3019 · Cited by 608
ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., Whitlow, P. L., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.001 · Cited by 532
Three-Year Follow-up after Implantation of Metallic Coronary-Artery Stents
Kimura, T., Yokoi, H., Nakagawa, Y., Tamura, T., Kaburagi, S., Sawada, Y., Sato, Y., Yokoi, H., Hamasaki, N., Nosaka, H., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602293340903 · Cited by 507
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.007 · Cited by 501
Bittl, J. A., Strony, J., Brinker, J. A., Ahmed, W. H., Meckel, C. R., Chaitman, B. R., Maraganore, J., Deutsch, E., & Adelman, B. (1995) · New England Journal of Medicine · doi:10.1056/nejm199509213331204 · Cited by 492
Primary and Secondary Prevention of Cardiovascular Disease
Vandvik, P. O., Lincoff, A. M., Gore, J. M., Gutterman, D. D., Sonnenberg, F. A., Alonso-Coello, P., Akl, E. A., Lansberg, M. G., Guyatt, G. H., & Spencer, F. A. (2012) · Chest · doi:10.1378/chest.11-2306 · Cited by 476
Percutaneous Transluminal Coronary Angioplasty
Landau, C., Lange, R. A., & Hillis, L. D. (1994) · New England Journal of Medicine · doi:10.1056/nejm199404073301407 · Cited by 445
Urban, P., Macaya, C., Rupprecht, H.-J., Kiemeneij, F., Emanuelsson, H., Fontanelli, A., Pieper, M., Wesseling, T., & Sagnard, L. (1998) · Circulation · doi:10.1161/01.cir.98.20.2126 · Cited by 445
ACC/AHA/SCAI Practice Guidelines, February 21, 2006
(2006) · Circulation · doi:10.1161/circulationaha.106.173220 · Cited by 422
Rodriguez, A., Bernardi, V., Navia, J., Baldi, J., Grinfeld, L., Martinez, J., Vogel, D., Grinfeld, R., Delacasa, A., Garrido, M., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01052-4 · Cited by 372
Serruys, P. W., Garcia-Garcia, H. M., & Onuma, Y. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr384 · Cited by 303
Stented segment length as an independent predictor of restenosis
Kobayashi, Y., De Gregorio, J., Kobayashi, N., Akiyama, T., Reimers, B., Finci, L., Di Mario, C., & Colombo, A. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00303-4 · Cited by 283
Hall, P., Nakamura, S., Maiello, L., Itoh, A., Blengino, S., Martini, G., Ferraro, M., & Colombo, A. (1996) · Circulation · doi:10.1161/01.cir.93.2.215 · Cited by 281
Bioresorbable scaffolds: rationale, current status, challenges, and future
Iqbal, J., Onuma, Y., Ormiston, J., Abizaid, A., Waksman, R., & Serruys, P. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht542 · Cited by 269
Cejna, M., Thurnher, S., Illiasch, H., Horvath, W., Waldenberger, P., Hornik, K., & Lammer, J. (2001) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(07)61397-9 · Cited by 254
Nitric Oxide: Implications for Vascular and Endovascular Surgery
Vural, K. M., & Bayazit, M. (2001) · European Journal of Vascular and Endovascular Surgery · doi:10.1053/ejvs.2001.1448 · Cited by 43
Metadata
- Authors
- Roubin, G. S., Cannon, A. D., Agrawal, S. K., Macander, P. J., Dean, L. S., Baxley, W. A., & Breland, J.
- Venue
- Circulation
- Published
- 1992-03
- Volume
- 85
- Issue
- 3
- Pages
- 916-927
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2087339238
- Cited by
- 582
- References
- 4
- FWCI
- 63.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.