The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Role of the Tricuspid Annulus and the Eustachian Valve/Ridge on Atrial Flutter: Relevance to Catheter Ablation of the Septal Isthmus and a New Technique for Rapid Identification of Ablation Success
Abstract
Background Typical atrial flutter (AFL) results from right atrial reentry by propagation through an isthmus between the inferior vena cava (IVC) and tricuspid annulus (TA). We postulated that the eustachian valve and ridge (EVR) forms a line of conduction block between the IVC and coronary sinus (CS) ostium and forms a second isthmus (septal isthmus) between the TA and CS ostium. Methods and Results Endocardial mapping in 30 patients with AFL demonstrated atrial activation around the TA in the counterclockwise direction (left anterior oblique projection). Double atrial potentials were recorded along the EVR in all patients during AFL. Pacing either side of the EVR during sinus rhythm also produced double potentials, which indicated fixed anatomic block across EVR. Entrainment pacing at the septal isthmus and multiple sites around the TA produced a Δ return interval ≤8 ms in 14 of 15 patients tested. Catheter ablation eliminated AFL in all patients by ablation of the septal isthmus in 26 patients and the posterior isthmus in 4. AFL recurred in 2 of 12 patients (mean follow-up, 33.9±16.3 months) in whom ablation success was defined by the inability to reinduce AFL, compared with none of 18 patients (mean follow-up, 10.3±8.3 months) in whom success required formation of a complete line of conduction block between the TA and the EVR, identified by CS pacing that produced atrial activation around the TA only in the counterclockwise direction and by pacing the posterior TA with only clockwise atrial activation. Conclusions ( 1) The EVR forms a line of fixed conduction block between the IVC and the CS; (2) the EVR and the TA provide boundaries for the AFL reentrant circuit; and (3) verification of a complete line of block between the TA and the EVR is a more reliable criterion for long-term ablation success.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac Electrophysiology: From Cell to Bedside
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1069_5 · Cited by 2,385
Stevenson, W. G., Khan, H., Sager, P., Saxon, L. A., Middlekauff, H. R., Natterson, P. D., & Wiener, I. (1993) · Circulation · doi:10.1161/01.cir.88.4.1647 · Cited by 909
Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter
Cosio, F. G., López-Gil, M., Goicolea, A., Arribas, F., & Barroso, J. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)91014-9 · Cited by 551
Feld, G. K., Fleck, R. P., Chen, P. S., Boyce, K., Bahnson, T. D., Stein, J. B., Calisi, C. M., & Ibarra, M. (1992) · Circulation · doi:10.1161/01.cir.86.4.1233 · Cited by 527
Olgin, J. E., Kalman, J. M., Fitzpatrick, A. P., & Lesh, M. D. (1995) · Circulation · doi:10.1161/01.cir.92.7.1839 · Cited by 500
Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms.
Lesh, M. D., Van Hare, G. F., Epstein, L. M., Fitzpatrick, A. P., Scheinman, M. M., Lee, R. J., Kwasman, M. A., Grogin, H. R., & Griffin, J. C. (1994) · Circulation · doi:10.1161/01.cir.89.3.1074 · Cited by 461
Waldo, A. L., MacLean, W. A., Karp, R. B., Kouchoukos, N. T., & James, T. N. (1977) · Circulation · doi:10.1161/01.cir.56.5.737 · Cited by 443
Studies on flutter and fibrillation
Rosenblueth, A., & Ramos, J. G. (1947) · American Heart Journal · doi:10.1016/0002-8703(47)90084-7 · Cited by 276
Wells, J. L., MacLean, W. A., James, T. N., & Waldo, A. L. (1979) · Circulation · doi:10.1161/01.cir.60.3.665 · Cited by 257
Natural and evoked atrial flutter due to circus movement in dogs
Boineau, J. P., Schuessler, R. B., Mooney, C. R., Miller, C. B., Wylds, A. C., Hudson, R. D., Borremans, J. M., & Brockus, C. W. (1980) · The American Journal of Cardiology · doi:10.1016/0002-9149(80)90475-0 · Cited by 248
Klein, G. J., Guiraudon, G. M., Sharma, A. D., & Milstein, S. (1986) · The American Journal of Cardiology · doi:10.1016/0002-9149(86)90840-4 · Cited by 223
Waldo, A. L., Plumb, V. J., Arciniegas, J. G., MacLean, W. A., Cooper, T. B., Priest, M. F., & James, T. N. (1983) · Circulation · doi:10.1161/01.cir.67.1.73 · Cited by 215
Frame, L. H., Page, R. L., & Hoffman, B. F. (1986) · Circulation Research · doi:10.1161/01.res.58.4.495 · Cited by 195
Radiofrequency ablation of atrial flutter. Efficacy of an anatomically guided approach.
Kirkorian, G., Moncada, E., Chevalier, P., Canu, G., Claudel, J. P., Bellon, C., Lyon, L., & Touboul, P. (1994) · Circulation · doi:10.1161/01.cir.90.6.2804 · Cited by 190
Morady, F., Kadish, A., Rosenheck, S., Calkins, H., Kou, W. H., De Buitleir, M., & Sousa, J. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80184-6 · Cited by 190
Catheter ablation of the atrial myocardium in human type I atrial flutter.
Saoudi, N., Atallah, G., Kirkorian, G., & Touboul, P. (1990) · Circulation · doi:10.1161/01.cir.81.3.762 · Cited by 184
Validation of double-spike electrograms as markers of conduction delay or block in atrial flutter
Cosío, F. G., Arribas, F., Barbero, J. M., Kallmeyer, C., & Goicolea, A. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)91065-x · Cited by 155
Characterization of double potentials in human atrial flutter: Studies during transient entrainment
Olshansky, B., Okumura, K., Henthorn, R. W., & Waldo, A. L. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90283-u · Cited by 146
Frame, L. H., Page, R. L., Boyden, P. A., Fenoglio, J. J., & Hoffman, B. F. (1987) · Circulation · doi:10.1161/01.cir.76.5.1155 · Cited by 142
Inoue, H., Matsuo, H., Takayanagi, K., & Murao, S. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90139-9 · Cited by 126
Evidence of a reentry circuit in the common type of atrial flutter in man.
Disertori, M., Inama, G., Vergara, G., Guarnerio, M., Favero, A. D., & Furlanello, F. (1983) · Circulation · doi:10.1161/01.cir.67.2.434 · Cited by 109
Fontaine, G. H., Frank, R., Tonet, J., et al. (1989) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1989.tb02656.x · Cited by 80
Characterization of double potentials in a functionally determined reentrant circuit
Shimizu, A., Nozaki, A., Rudy, Y., & Waldo, A. L. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90793-z · Cited by 64
Boyden, P. A. (1988) · Circulation Research · doi:10.1161/01.res.62.3.596 · Cited by 57
HFrame, L., LPage, R., ABoyden, P., JFenoglio, J., & FHoffman, B. (1987) · Circulation · Cited by 57
Role of anatomic architecture in sustained atrial reentry and double potentials
Yamashita, T., Inoue, H., Nozaki, A., & Sugimoto, T. (1992) · American Heart Journal · doi:10.1016/0002-8703(92)90976-3 · Cited by 44
Tabuchi, T., Okumura, K., Matsunaga, T., Tsunoda, R., Jougasaki, M., & Yasue, H. (1995) · Circulation · doi:10.1161/01.cir.92.5.1312 · Cited by 40
Classic and Concealed Entrainment of Typical and Atypical Atrial Flutter
Beckman, K. J., HUANG‐TA‐LIN, Krafchek, J., & Wyndham, C. R. C. (1986) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1986.tb06632.x · Cited by 38
Self-citationTanoiri, T., Komatsu, C., ISHINAGA, T., Tokuhisa, Y., Makino, H., Nomoto, J., Mogi, J., & Okamura, T. (1991) · American Heart Journal · doi:10.1016/0002-8703(91)90955-h · Cited by 10
FUJIMOTO, T., INOUE, T., & Fukuzaki, H. (1990) · Japanese Circulation Journal-english Edition · doi:10.1253/jcj.54.21 · Cited by 10
ABSTRACT SESSION 22: PACEMAKERS; FUNCTION AND DYSFUNCTION
(1993) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1993.tb01690.x · Cited by 2
Cited by
Saoudi, N., Cosío, F., Waldo, A., Chen, S. A., Iesaka, Y., Lesh, M., Saksena, S., Salerno, J., & Schoels, W. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2658 · Cited by 464
Natale, A., Newby, K. H., Pisanó, E., Leonelli, F., Fanelli, R., Potenza, D., Beheiry, S., & Tomassoni, G. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00635-5 · Cited by 414
Characterization of Left Atrial Activation in the Intact Human Heart
Markides, V., Schilling, R. J., Yen Ho, S., Chow, A. W. C., Davies, D. W., & Peters, N. S. (2003) · Circulation · doi:10.1161/01.cir.0000048140.31785.02 · Cited by 284
Differential pacing for distinguishing block from persistent conduction through an ablation line
Shah, D., Haïssaguerre, M., Takahashi, A., Jaïs, P., Hocini, M., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.102.13.1517 · Cited by 242
Collins, K. K., Love, B. A., Walsh, E. P., Saul, J. P., Epstein, M. R., & Triedman, J. K. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01132-2 · Cited by 194
Metadata
- Authors
- Nakagawa, H., Lazzara, R., Khastgir, T., Beckman, K. J., McClelland, J. H., Imai, S., Pitha, J. V., Becker, A. E., Arruda, M., Gonzalez, M. D., Widman, L. E., Rome, M., Neuhauser, J., Wang, X., Calame, J. D., Goudeau, M. D., & Jackman, W. M.
- Venue
- Circulation
- Published
- 1996-08
- Volume
- 94
- Issue
- 3
- Pages
- 407-424
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2129964873
- Cited by
- 363
- References
- 31
- FWCI
- 23.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.