The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Pathology of Acute and Chronic Coronary Stenting in Humans
Abstract
Background —Despite the increasing use of stents, few reports have described human coronary artery morphology early and late after stenting. Methods and Results —Histology was performed on 55 stents in 35 coronary vessels (32 native arteries and 3 vein grafts) from 32 patients. The mean duration of stent placement was 39±82 days. Fibrin, platelets, and neutrophils were associated with stent struts ≤11 days after deployment. In stents implanted for ≤3 days, only 3% of struts in contact with fibrous plaque had >20 associated inflammatory cells compared with 44% of struts embedded in a lipid core and 36% of struts in contact with damaged media ( P <0.001). Neointimal growth determined late histological success, and increased neointimal growth correlated with increased stent size relative to the proximal reference lumen area. Neointimal thickness was greater for struts associated with medial damage than struts in contact with plaque ( P <0.0001) or intact media ( P <0.0001). When matched for time since treatment, neointimal cell density in stented arteries was similar to that in unstented arteries that had undergone balloon angioplasty and showed similar proteoglycan deposition. Conclusions —Morphology after coronary stenting demonstrates early thrombus formation and acute inflammation followed by neointimal growth. Medial injury and lipid core penetration by struts result in increased inflammation. Neointima increases as the ratio of stent area to reference lumen area increases. Deployment strategies that reduce medial damage and avoid stent oversizing may lower the frequency of in-stent restenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Schwartz, R. S., Huber, K. C., Murphy, J. G., Edwards, W. D., Camrud, A. R., Vlietstra, R. E., & Holmes, D. R. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90476-4 · Cited by 1,175
Self-citationEndovascular Stent Design Dictates Experimental Restenosis and Thrombosis
Rogers, C., & Edelman, E. R. (1995) · Circulation · doi:10.1161/01.cir.91.12.2995 · Cited by 543
Carter, A. J., Laird, J. R., Farb, A., Kufs, W., Wortham, D. C., & Virmani, R. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90126-0 · Cited by 229
Self-citationMonocyte Recruitment and Neointimal Hyperplasia in Rabbits: Coupled Inhibitory Effects of Heparin
Rogers, C., Welt, F. G. P., Karnovsky, M. J., & Edelman, E. R. (1996) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.16.10.1312 · Cited by 209
van Beusekom, H. M. M., van der Giessen, W. J., van Suylen, R. J., Bos, E., Bosman, F., & Serruys, P. W. J. C. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90715-d · Cited by 163
“Bailout” coronary stenting in patients with a recent myocardial infarction
Thomas, C. N., Weintraub, W. S., Shen, Y., et al. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)89326-5 · Cited by 6
Cited by
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Daemen, J., Wenaweser, P., Tsuchida, K., Abrecht, L., Vaina, S., Morger, C., Kukreja, N., Jüni, P., Sianos, G., Hellige, G., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60314-6 · Cited by 1,757
2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.006 · Cited by 1,558
Sata, M., Saiura, A., Kunisato, A., Tojo, A., Okada, S., Tokuhisa, T., Hirai, H., Makuuchi, M., Hirata, Y., & Nagai, R. (2002) · Nature Medicine · doi:10.1038/nm0402-403 · Cited by 1,148
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001038 · Cited by 829
Camenzind, E., Steg, P. G., & Wijns, W. (2007) · Circulation · doi:10.1161/circulationaha.106.666800 · Cited by 818
Newby, A. C. (2005) · Physiological Reviews · doi:10.1152/physrev.00048.2003 · Cited by 817
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Stent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model
Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., Klugherz, B. D., Papandreou, G., Narayan, P., Leon, M. B., et al. (2001) · Circulation · doi:10.1161/hc3601.093987 · Cited by 708
Self-citationA hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents
Babapulle, M. N., Joseph, L., Bélisle, P., Brophy, J. M., & Eisenberg, M. J. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16850-5 · Cited by 645
Byrne, R. A., Joner, M., & Kastrati, A. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv511 · Cited by 609
Morphological Predictors of Restenosis After Coronary Stenting in Humans
Farb, A., Weber, D. K., Kolodgie, F. D., Burke, A. P., & Virmani, R. (2002) · Circulation · doi:10.1161/01.cir.0000019071.72887.bd · Cited by 593
Self-citationExpression, Regulation, and Function of IGF-1, IGF-1R, and IGF-1 Binding Proteins in Blood Vessels
Delafontaine, P., Song, Y.-H., & Li, Y. (2004) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000105902.89459.09 · Cited by 542
Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
Köster, R., Vieluf, D., Kiehn, M., Sommerauer, M., Kähler, J., Baldus, S., Meinertz, T., & Hamm, C. W. (2000) · The Lancet · doi:10.1016/s0140-6736(00)03262-1 · Cited by 530
Pathological Mechanisms of Fatal Late Coronary Stent Thrombosis in Humans
Farb, A., Burke, A. P., Kolodgie, F. D., & Virmani, R. (2003) · Circulation · doi:10.1161/01.cir.0000091115.05480.b0 · Cited by 478
Self-citationThe role of nanometer and sub-micron surface features on vascular and bone cell adhesion on titanium
Khang, D., Lu, J., Yao, C., Haberstroh, K. M., & Webster, T. J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.009 · Cited by 437
The Insulin-Like Growth Factor Axis: A Review of Atherosclerosis and Restenosis
Bayes-Genis, A., Conover, C. A., & Schwartz, R. S. (2000) · Circulation Research · doi:10.1161/01.res.86.2.125 · Cited by 416
Self-citationCoronary in-stent restenosis: Current status and future strategies
Lowe, H. C., Oesterle, S. N., & Khachigian, L. M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01742-9 · Cited by 414
Grewe, P. H., Deneke, T., Machraoui, A., Barmeyer, J., & Müller, K.-M. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00486-6 · Cited by 401
Friedrich, E. B., Walenta, K., Scharlau, J., Nickenig, G., & Werner, N. (2006) · Circulation Research · doi:10.1161/01.res.0000205765.28940.93 · Cited by 333
Topol, E. J., Mark, D. B., Lincoff, A. M., Cohen, E., Burton, J., Kleiman, N., Talley, D., Sapp, S., Booth, J., Cabot, C. F., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)10018-7 · Cited by 324
Drug eluting stents: are human and animal studies comparable?
Virmani, R., Kolodgie, F. D., Farb, A., & Lafont, A. (2003) · Heart · doi:10.1136/heart.89.2.133 · Cited by 300
Self-citationDrug-Eluting Stents in Preclinical Studies: Recommended Evaluation From a Consensus Group
Schwartz, R. S., Edelman, E. R., Carter, A., Chronos, N., Rogers, C., Robinson, K. A., Waksman, R., Weinberger, J., Wilensky, R. L., Jensen, D. N., et al. (2002) · Circulation · doi:10.1161/01.cir.0000033485.20594.6f · Cited by 291
Self-citationLu, J., Rao, M. P., MacDonald, N. C., Khang, D., & Webster, T. J. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.07.008 · Cited by 290
A comparison of covered vs bare expandable stents for the treatment of aortoiliac occlusive disease
Mwipatayi, B. P., Thomas, S., Wong, J., Temple, S. E. L., Vijayan, V., Jackson, M., & Burrows, S. A. (2011) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2011.06.097 · Cited by 276
Chew, D. P., Bhatt, D. L., Robbins, M. A., Penn, M. S., Schneider, J. P., Lauer, M. S., Topol, E. J., & Ellis, S. G. (2001) · Circulation · doi:10.1161/hc3401.095074 · Cited by 260
Soeda, T., Uemura, S., Park, S.-J., Jang, Y., Lee, S., Cho, J.-M., Kim, S.-J., Vergallo, R., Minami, Y., Ong, D. S., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.014704 · Cited by 260
Ribichini, F., Tomai, F., De Luca, G., Boccuzzi, G., Presbitero, P., Pesarini, G., Ferrero, V., Ghini, A. S., Abukaresh, R., Aurigemma, C., et al. (2011) · The American Journal of Medicine · doi:10.1016/j.amjmed.2010.11.027 · Cited by 31
Endothelial biocompatibility and accumulation of SPION under flow conditions
Matuszak, J., Zaloga, J., Friedrich, R. P., Lyer, S., Nowak, J., Odenbach, S., Alexiou, C., & Cicha, I. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2014.09.005 · Cited by 24
Metadata
- Authors
- Farb, A., Sangiorgi, G., Carter, A. J., Walley, V. M., Edwards, W. D., Schwartz, R. S., & Virmani, R.
- Venue
- Circulation
- Published
- 1999-01-12
- Volume
- 99
- Issue
- 1
- Pages
- 44-52
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2063973040
- Cited by
- 871
- References
- 8
- FWCI
- 43.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.