Cardiac Microstructure: Implications for Electrical Propagation and Defibrillation in the Heart
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Our understanding of the electrophysiological properties of the heart is incomplete. We have investigated two issues that are fundamental to advancing that understanding. First, there has been widespread debate over the mechanisms by which an externally applied shock can influence a sufficient volume of heart tissue to terminate cardiac fibrillation. Second, it has been uncertain whether cardiac tissue should be viewed as an electrically orthotropic structure, or whether its electrical properties are, in fact, isotropic in the plane orthogonal to myofiber direction. In the present study, a computer model that incorporates a detailed three-dimensional representation of cardiac muscular architecture is used to investigate these issues. We describe a bidomain model of electrical propagation solved in a discontinuous domain that accurately represents the microstructure of a transmural block of rat left ventricle. From analysis of the model results, we conclude that (1) the laminar organization of myocytes determines unique electrical properties in three microstructurally defined directions at any point in the ventricular wall of the heart, and (2) interlaminar clefts between layers of cardiomyocytes provide a substrate for bulk activation of the ventricles during defibrillation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zienkiewicz, O. C. (1989) · Cited by 14,802
Reconstruction of the action potential of ventricular myocardial fibres
Beeler, G. W., & Reuter, H. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011853 · Cited by 1,421
Spach, M. S., & Dolber, P. C. (1986) · Circulation Research · doi:10.1161/01.res.58.3.356 · Cited by 892
LeGrice, I. J., Smaill, B. H., Chai, L. Z., Edgar, S. G., Gavin, J. B., & Hunter, P. J. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.269.2.h571 · Cited by 842
Self-citationGardner, P. I., Ursell, P. C., Fenoglio, J. J., & Wit, A. L. (1985) · Circulation · doi:10.1161/01.cir.72.3.596 · Cited by 686
Simulating the electrical behavior of cardiac tissue using the bidomain model.
Henriquez, C. S. (1993) · PubMed · Cited by 549
(2007) · doi:10.1007/978-0-387-48865-3 · Cited by 483
(1979) · PubMed · Cited by 470
Paradoxical Improvement of Impulse Conduction in Cardiac Tissue by Partial Cellular Uncoupling
Rohr, S., Kucera, J. P., Fast, V. G., & Kléber, A. G. (1997) · Science · doi:10.1126/science.275.5301.841 · Cited by 290
Robb, J. S., & Robb, R. C. (1942) · American Heart Journal · doi:10.1016/s0002-8703(42)90291-6 · Cited by 281
Cited by
Hunter, P. J., Pullan, A. J., & Smaill, B. H. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121537 · Cited by 291
Self-citationVerification of cardiac tissue electrophysiology simulators using an N -version benchmark
Niederer, S. A., Kerfoot, E., Benson, A. P., Bernabeu, M. O., Bernus, O., Bradley, C., Cherry, E. M., Clayton, R., Fenton, F. H., Garny, A., et al. (2011) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0139 · Cited by 275
Computational physiology and the physiome project
Crampin, E. J., Halstead, M., Hunter, P., Nielsen, P., Noble, D., Smith, N., & Tawhai, M. (2004) · Experimental Physiology · doi:10.1113/expphysiol.2003.026740 · Cited by 246
“Figs A and B, from Hooks et al. (2002) with permission.”
BackgroundSelf-citationVisualization of spiral and scroll waves in simulated and experimental cardiac tissue
Cherry, E. M., & Fenton, F. H. (2008) · New Journal of Physics · doi:10.1088/1367-2630/10/12/125016 · Cited by 236
Electrical coupling of fibroblasts and myocytes: relevance for cardiac propagation
Kohl, P., Camelliti, P., Burton, F. L., & Smith, G. L. (2005) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2005.06.096 · Cited by 233
“In both settings, fibroblasts could play important roles by connecting individual clusters of pacemaker cells in the SAN or by smoothing transmural ventricular propagation, which, given the highly anisotropic laminar substrate of the ventricular wall, would otherwise give rise to rather fractionated conduction pattern…”
A Mathematical Model of Electrotonic Interactions between Ventricular Myocytes and Fibroblasts
Andrew MacCannell, K., Bazzazi, H., Chilton, L., Shibukawa, Y., Clark, R. B., & Giles, W. R. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.101410 · Cited by 228
Human Atlas of the Cardiac Fiber Architecture: Study on a Healthy Population
Lombaert, H., Peyrat, J., Croisille, P., Rapacchi, S., Fanton, L., Cheriet, F., Clarysse, P., Magnin, I., Delingette, H., & Ayache, N. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2192743 · Cited by 227
“The cardiac fiber architecture, a complex organization of the myocardium fibers [28], [45], determines various cardiac mechanical functions [10], cardiac electrophysiology patterns [24], and remodeling processes [53].”
BackgroundA guide to modelling cardiac electrical activity in anatomically detailed ventricles
Clayton, R. H., & Panfilov, A. V. (2008) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2007.07.004 · Cited by 220
“Propagation of the action potential is two to three times faster in the fibre direction than orthogonal to it, and propagation orthogonal to sheets is believed to be two to three times slower than orthogonal to fibres (Hooks et al., 2002).”
BackgroundLaminar Arrangement of Ventricular Myocytes Influences Electrical Behavior of the Heart
Hooks, D. A., Trew, M. L., Caldwell, B. J., Sands, G. B., LeGrice, I. J., & Smaill, B. H. (2007) · Circulation Research · doi:10.1161/circresaha.107.161075 · Cited by 187
Self-citationCyber–Physical Modeling of Implantable Cardiac Medical Devices
Jiang, Z., Pajic, M., & Mangharam, R. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2161241 · Cited by 172
Bishop, M. J., Plank, G., Burton, R. A. B., Schneider, J. E., Gavaghan, D. J., Grau, V., & Kohl, P. (2010) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00606.2009 · Cited by 171
Colli Franzone, P., Pavarino, L. F., & Taccardi, B. (2005) · Mathematical Biosciences · doi:10.1016/j.mbs.2005.04.003 · Cited by 170
Organization of Ventricular Fibrillation in the Human Heart
Ten Tusscher, K. H. W. J., Hren, R., & Panfilov, A. V. (2007) · Circulation Research · doi:10.1161/circresaha.107.150730 · Cited by 159
Fibrous scaffolds for building hearts and heart parts
Capulli, A. K., MacQueen, L. A., Sheehy, S. P., & Parker, K. K. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.020 · Cited by 130
“The laminar architecture of ventricular myocardium thus gives rise to orthotropic electric properties with slow propagation normal to laminae [86,87].”
Influence of anisotropic conduction properties in the propagation of the cardiac action potential
Valderrábano, M. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2007.03.014 · Cited by 125
“, 1995) has important implications to propagation and defibrillation.(Hooks et al., 2002) Enhanced microscopic discontinuities present in nonuniform anisotropy greatly increase the susceptibility to anisotropic reentry.”
BackgroundInfluentialCarusi, A., Burrage, K., & Rodríguez, B. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01151.2011 · Cited by 102
“Conductivity values along and across fibers are indirectly determined to yield the conduction velocities in all directions and are measured experimentally in tissue (44).”
BackgroundThe IUPS Physiome Project: a framework for computational physiology
Hunter, P. J. (2004) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2004.02.006 · Cited by 66
“Here a tissue level model is used to examine current flow through myocardial sheet structures and then the conductivity parameters of a continuum model are optimized to match the tissue model (Hooks et al., 2001, 2002).”
MethodSelf-citationImage-Based Predictive Modeling of Heart Mechanics
Wang, V. Y., Nielsen, P. M. F., & Nash, M. P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040609 · Cited by 63
Kléber, A. G., & Jin, Q. (2021) · Biophysics Reviews · doi:10.1063/5.0050192 · Cited by 29
Nguyen, T. D., Kadri, O. E., & Voronov, R. S. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.529365 · Cited by 19
Metadata
- Authors
- Hooks, D. A., Tomlinson, K. A., Marsden, S. G., LeGrice, I. J., Smaill, B. H., Pullan, A. J., & Hunter, P. J.
- Venue
- Circulation Research
- Published
- 2002-08-23
- Volume
- 91
- Issue
- 4
- Pages
- 331-338
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2137128251
- Cited by
- 244
- References
- 27
- FWCI
- 11.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.