Pressure-flow characteristics of coronary stenoses in unsedated dogs at rest and during coronary vasodilation.
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The pressure-flow characteristics of 100 left circumflex stenoses in 10 chronically instrumented unsedated dogs were studied under resting conditions and during pharmacological coronary vasodilation. At rest, the pressure loss (deltaP) due to a stenosis and arterial flow velocity (V) were related by the equation, deltaP = FV + SV2, where F is the coefficient of pressure loss due to viscous friction in the stenotic segment and S is the coefficient of pressure loss due to flow separation at the diverging end of the stenosis. The linear term due to viscous friction accounted for 65% and the nonlinear term due to flow separation accounted for 35% of the total pressure loss at resting coronary flow. At peak coronary flow after coronary vasodilation, the pressure loss due to viscous friction accounted for 33% and pressure loss due to flow separation accounted for 67% of the total pressure loss. The pressure gradient-velocity relationship at high flows was characterized by the same general equation but with proportionately larger values of the coefficient S and therefore greater pressure loss associated with flow separation than predicted by the resting gradient-velocity relationship. The pressure loss predicted for high coronary flow velocities on the basis of the gradient-velocity equation at rest was only 64% of the actual experimentally observed pressure gradient at peak coronary flow. The augmented separation loss following coronary vasodilation probably was due to dilation of the epicardial artery adjacent to the fixed stenotic segment which caused more severe relative percent narrowing and a larger divergence angle at the distal end of the stenosis, the primary geometric determinants of separation losses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiologic basis for assessing critical coronary stenosis
Gould, K. L., Lipscomb, K., & Hamilton, G. W. (1974) · The American Journal of Cardiology · doi:10.1016/0002-9149(74)90743-7 · Cited by 1,532
Self-citationFluid Mechanics with Engineering Applications
Daugherty, R. L., & Franzini, J. B. (1965) · CERN Document Server (European Organization for Nuclear Research) · Cited by 911
Effects of coronary stenoses on coronary flow reserve and resistance
Gould, K. L., & Lipscomb, K. (1974) · The American Journal of Cardiology · doi:10.1016/0002-9149(74)90092-7 · Cited by 882
Self-citationExperimental Subendocardial Ischemia in Dogs with Normal Coronary Arteries
BUCKBERG, G. D., FIXLER, D. E., ARCHIE, J. P., & HOFFMAN, J. I. E. (1972) · Circulation Research · doi:10.1161/01.res.30.1.67 · Cited by 845
Interobserver variability in coronary angiography.
Zir, L. M., Miller, S. W., Dinsmore, R. E., Gilbert, J. P., & Harthorne, J. W. (1976) · Circulation · doi:10.1161/01.cir.53.4.627 · Cited by 768
Flow characteristics in models of arterial stenoses — II. Unsteady flow
Young, D. F., & Tsai, F. Y. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90012-2 · Cited by 680
Variability in the analysis of coronary arteriograms.
DeRouen, T. A., Murray, J. A., & Owen, W. (1977) · Circulation · doi:10.1161/01.cir.55.2.324 · Cited by 485
Observer agreement in evaluating coronary angiograms.
Detre, K. M., Wright, E., Murphy, M. L., & Takaro, T. (1975) · Circulation · doi:10.1161/01.cir.52.6.979 · Cited by 447
Correlation of the Antemortem Coronary Arteriogram and the Postmortem Specimen
VLODAVER, Z., FRECH, R., VAN TASSEL, R. A., & EDWARDS, J. E. (1973) · Circulation · doi:10.1161/01.cir.47.1.162 · Cited by 395
GRONDIN, C. M., DYRDA, I., PASTERNAC, A., CAMPEAU, L., BOURASSA, M. G., & LESPÉRANCE, J. (1974) · Circulation · doi:10.1161/01.cir.49.4.703 · Cited by 341
Fluid dynamics of coronary artery stenosis.
Mates, R. E., Gupta, R. L., Bell, A. C., & Klocke, F. J. (1978) · Circulation Research · doi:10.1161/01.res.42.1.152 · Cited by 196
Local Regulation of Vascular Cross Section during Changes in Femoral Arterial Blood Flow in Dogs
Lie, M., Sejersted, O. M., & Kiil, F. (1970) · Circulation Research · doi:10.1161/01.res.27.5.727 · Cited by 157
Transmural distribution of myocardial blood flow during systole in the awake dog.
Hess, D., & Bache, R. J. (1976) · Circulation Research · doi:10.1161/01.res.38.1.5 · Cited by 145
Distribution of myocardial blood flow in the exercising dog with restricted coronary artery inflow.
Ball, R. M., & Bache, R. J. (1976) · Circulation Research · doi:10.1161/01.res.38.2.60 · Cited by 111
Epicardial Coronary Artery Compliance in the Dog
DOUGLAS, J. E., & Greenfield, J. C. (1970) · Circulation Research · doi:10.1161/01.res.27.6.921 · Cited by 91
Range of the Sympathetic Control of the Dog Femoral Artery
Gerová, M., & GERO, J. (1969) · Circulation Research · doi:10.1161/01.res.24.3.349 · Cited by 47
Ingebrigtsen, R., & Leraand, S. (1970) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1970.tb04757.x · Cited by 45
Cited by
Ku, D. N. (1997) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.29.1.399 · Cited by 1,477
Fluid Mechanics of Vascular Systems, Diseases, and Thrombosis
Wootton, D. M., & Ku, D. N. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.299 · Cited by 559
A Preliminary Report Comparing Magnetic Resonance Coronary Angiography with Conventional Angiography
Manning, W. J., Li, W., & Edelman, R. R. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303253281202 · Cited by 544
Brown, B. G., Bolson, E., Petersen, R. B., Pierce, C. D., & Dodge, H. T. (1981) · Circulation · doi:10.1161/01.cir.64.6.1089 · Cited by 458
Reconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure Measurements
Bos, W. J. W., van Goudoever, J., van Montfrans, G. A., van den Meiracker, A. H., & Wesseling, K. H. (1996) · Circulation · doi:10.1161/01.cir.94.8.1870 · Cited by 365
Metadata
- Authors
- Gould, K. L.
- Venue
- Circulation Research
- Published
- 1978-08
- Volume
- 43
- Issue
- 2
- Pages
- 242-253
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2171820116
- Cited by
- 368
- References
- 17
- FWCI
- 11.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.