Stroke Magnetic Resonance Imaging Is Accurate in Hyperacute Intracerebral Hemorrhage: A Multicenter Study on the Validity of Stroke Imaging
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Background and Purpose— Although modern multisequence stroke MRI protocols are an emerging imaging routine for the diagnostic assessment of acute ischemic stroke, their sensitivity for intracerebral hemorrhage (ICH), the most important differential diagnosis, is still a matter of debate. We hypothesized that stroke MRI is accurate in the detection of ICH. To evaluate our hypotheses, we conducted a prospective multicenter trial. Methods— Stroke MRI protocols of 6 university hospitals were standardized. Images from 62 ICH patients and 62 nonhemorrhagic stroke patients, all imaged within the first 6 hours after symptom onset (mean, 3 hours 18 minutes), were analyzed. For diagnosis of hemorrhage, CT served as the “gold standard.” Three readers experienced in stroke imaging and 3 final-year medical students, unaware of clinical details, separately evaluated sets of diffusion-, T2-, and T2*-weighted images. The extent and phenomenology of the hemorrhage on MRI were assessed separately. Results— Mean patient age was 65.5 years; median National Institutes of Health Stroke Scale score was 10. The experienced readers identified ICH with 100% sensitivity (confidence interval, 97.1 to 100) and 100% overall accuracy. Mean ICH size was 17.3 mL (range, 1 to 101.5 mL). The students reached a mean sensitivity of 95.16% (confidence interval, 90.32 to 98.39). Conclusions— Hyperacute ICH causes a characteristic imaging pattern on stroke MRI and is detectable with excellent accuracy. Even raters with limited film-reading experience reached good accuracy. Stroke MRI alone can rule out ICH and demonstrate the underlying pathology in hyperacute stroke.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Plasminogen Activator for Acute Ischemic Stroke
(1995) · New England Journal of Medicine · doi:10.1056/nejm199512143332401 · Cited by 11,654
Hacke, W., Kaste, M., Fieschi, C., von Kummer, R., Davalos, A., Meier, D., Larrue, V., Bluhmki, E., Davis, S., Donnan, G., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(98)08020-9 · Cited by 3,662 · cited 1×
“All MRI machines used had echo-planar capabilities but were different 1.5-T systems: Siemens Vision ( 4 ), Siemens Symphony (1), and Marconi Edge (1).”
MethodInfluentialSelf-citationThe ABCs of Measuring Intracerebral Hemorrhage Volumes
Kothari, R. U., Brott, T., Broderick, J. P., Barsan, W. G., Sauerbeck, L. R., Zuccarello, M., & Khoury, J. (1996) · Stroke · doi:10.1161/01.str.27.8.1304 · Cited by 2,222
Sorensen, A. G., Buonanno, F. S., Gonzalez, R. G., Schwamm, L. H., Lev, M. H., Huang-Hellinger, F. R., Reese, T. G., Weisskoff, R. M., Davis, T. L., Suwanwela, N., et al. (1996) · Radiology · doi:10.1148/radiology.199.2.8668784 · Cited by 730
The ischemic penumbra: Operationally defined by diffusion and perfusion MRI
Schlaug, G., Benfield, A., Baird, A. E., Siewert, B., Lövblad, K. O., Parker, R. A., Edelman, R. R., & Warach, S. (1999) · Neurology · doi:10.1212/wnl.53.7.1528 · Cited by 663
Magnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 545
Fiebach, J. B., Schellinger, P. D., Jansen, O., Meyer, M., Wilde, P., Bender, J., Schramm, P., Jüttler, E., Oehler, J., Hartmann, M., et al. (2002) · Stroke · doi:10.1161/01.str.0000026864.20339.cb · Cited by 507
Self-citationKidwell, C. S., Alger, J. R., & Saver, J. L. (2003) · Stroke · doi:10.1161/01.str.0000097608.38779.cc · Cited by 473
Magnetic Resonance Imaging Detection of Microbleeds Before Thrombolysis: An Emerging Application
Kidwell, C. S., Saver, J. L., Villablanca, J. P., Duckwiler, G., Fredieu, A., Gough, K., Leary, M. C., Starkman, S., Gobin, Y. P., Jahan, R., et al. (2002) · Stroke · doi:10.1161/hs0102.101792 · Cited by 346
A Standardized MRI Stroke Protocol: Comparison with CT in Hyperacute Intracerebral Hemorrhage
Schellinger, P. D., Jansen, O., Fiebach, J. B., Hacke, W., & Sartor, K. (1999) · Stroke · doi:10.1161/01.str.30.4.765 · Cited by 319
Self-citationNighoghossian, N., Hermier, M., Adeleine, P., Blanc-Lasserre, K., Derex, L., Honnorat, J., Philippeau, F., Dugor, J. F., Froment, J. C., & Trouillas, P. (2002) · Stroke · doi:10.1161/hs0302.104615 · Cited by 301
MRI Features of Intracerebral Hemorrhage Within 2 Hours From Symptom Onset
Linfante, I., Llinas, R. H., Caplan, L. R., & Warach, S. (1999) · Stroke · doi:10.1161/01.str.30.11.2263 · Cited by 296
Linfante, I., Llinas, R. H., Selim, M., Chaves, C., Kumar, S., Parker, R. A., Caplan, L. R., & Schlaug, G. (2002) · Stroke · doi:10.1161/01.str.0000021001.18101.a5 · Cited by 262
Detection of Hyperacute Primary Intraparenchymal Hemorrhage by Magnetic Resonance Imaging
Patel, M. R., Edelman, R. R., & Warach, S. (1996) · Stroke · doi:10.1161/01.str.27.12.2321 · Cited by 242
Thrombolysis in acute ischemic stroke: controlled trials and clinical experience.
Hacke, W., Brott, T. G., Caplan, L. R., Meier, D., Fieschi, C., von Kummer, R., Donnan, G. A., Wd, H., Wahlgren, N. G., Spranger, M., et al. (1999) · PubMed · Cited by 240
Self-citationStroke magnetic resonance imaging within 6 hours after onset of hyperacute cerebral ischemia
Schellinger, P. D., Fiebach, J. B., Jansen, O., Ringleb, P. A., Mohr, A., Steiner, T., Heiland, S., Schwab, S., Pohlers, O., Ryssel, H., et al. (2001) · Annals of Neurology · doi:10.1002/ana.95 · Cited by 226
Self-citationStroke MRI in Intracerebral Hemorrhage: Is There a Perihemorrhagic Penumbra?
Schellinger, P. D., Fiebach, J. B., Hoffmann, K., Becker, K., Orakcioglu, B., Kollmar, R., Jüttler, E., Schramm, P., Schwab, S., Sartor, K., et al. (2003) · Stroke · doi:10.1161/01.str.0000076010.10696.55 · Cited by 209
Self-citationThe Gold Standard: What it Means and How it Works
Hogg, D. (1932) · Royal United Services Institution. Journal · doi:10.1080/03071843209420327 · Cited by 207
Intracerebral hemorrhage versus infarction: Stroke severity, risk factors, and prognosis
Jørgensen, H. S., Nakayama, H., Raaschou, H. O., & Olsen, T. S. (1995) · Annals of Neurology · doi:10.1002/ana.410380110 · Cited by 204
CACNA1A mutations: Hemiplegic migraine, episodic ataxia type 2, and the others
Tournier-Lasserve, E. (1999) · Neurology · doi:10.1212/wnl.53.1.3 · Cited by 197
Selim, M., Fink, J. N., Kumar, S., Caplan, L. R., Horkan, C., Chen, Y., Linfante, I., & Schlaug, G. (2002) · Stroke · doi:10.1161/01.str.0000023577.65990.4e · Cited by 189
Schellinger, P. D., Jansen, O., Fiebach, J. B., Heiland, S., Steiner, T., Schwab, S., Pohlers, O., Ryssel, H., Sartor, K., & Hacke, W. (2000) · Stroke · doi:10.1161/01.str.31.6.1318 · Cited by 188
Self-citationHyperacute Stroke: Ultrafast MR Imaging to Triage Patients prior to Therapy
Sunshine, J. L., Tarr, R. W., Lanzieri, C. F., Landis, D. M. D., Selman, W. R., & Lewin, J. S. (1999) · Radiology · doi:10.1148/radiology.212.2.r99au52325 · Cited by 176
Diffusion-perfusion MR evaluation of perihematomal injury in hyperacute intracerebral hemorrhage
Kidwell, C. S., Saver, J. L., Mattiello, J., Warach, S., Liebeskind, D. S., Starkman, S., Vespa, P. M., Villablanca, J. P., Martin, N. A., Frazee, J., et al. (2001) · Neurology · doi:10.1212/wnl.57.9.1611 · Cited by 158
MR of hemorrhage: a new approach.
Edelman, R. R., Johnson, K., Buxton, R. B., Shoukimas, G. M., Rosen, B. R., Davis, K. R., & Brady, T. J. (1986) · PubMed · Cited by 142
MR detection of hyperacute parenchymal hemorrhage of the brain.
Atlas, S. W., & Thulborn, K. R. (1998) · PubMed Central · Cited by 136
Treatment of Relevant Nerve Roots Involved in Nerve Sheath Tumors: Removal or Preservation?
Celli, P. (2002) · Neurosurgery · doi:10.1097/00006123-200209000-00012 · Cited by 105
MRI: The New Gold Standard for Detecting Brain Hemorrhage?
von Kummer, R. (2002) · Stroke · doi:10.1161/01.str.0000019882.06696.d6 · Cited by 27
Cited by
Jauch, E. C., Saver, J. L., Adams, H. P., Bruno, A., Connors, J. J. (., Demaerschalk, B. M., Khatri, P., McMullan, P. W., Qureshi, A. I., Rosenfield, K., et al. (2013) · Stroke · doi:10.1161/str.0b013e318284056a · Cited by 7,634
Powers, W. J., Rabinstein, A. A., Ackerson, T., Adeoye, O. M., Bambakidis, N. C., Becker, K., Biller, J., Brown, M., Demaerschalk, B. M., Hoh, B., et al. (2019) · Stroke · doi:10.1161/str.0000000000000211 · Cited by 7,468
Hemphill, J. C., Greenberg, S. M., Anderson, C. S., Becker, K., Bendok, B. R., Cushman, M., Fung, G. L., Goldstein, J. N., Macdonald, R. L., Mitchell, P. H., et al. (2015) · Stroke · doi:10.1161/str.0000000000000069 · Cited by 3,994
Adams, H. P., del Zoppo, G., Alberts, M. J., Bhatt, D. L., Brass, L., Furlan, A., Grubb, R. L., Higashida, R. T., Jauch, E. C., Kidwell, C., et al. (2007) · Stroke · doi:10.1161/strokeaha.107.181486 · Cited by 2,475
van Gijn, J., Kerr, R. S., & Rinkel, G. J. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60153-6 · Cited by 1,677
Metadata
- Authors
- Fiebach, J. B., Schellinger, P. D., Gass, A., Kucinski, T., Siebler, M., Villringer, A., Ölkers, P., Hirsch, J. G., Heiland, S., Wilde, P., Jansen, O., Röther, J., Hacke, W., & Sartor, K.
- Venue
- Stroke
- Published
- 2004-02
- Volume
- 35
- Issue
- 2
- Pages
- 502-506
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2152868178
- Cited by
- 434
- References
- 28
- FWCI
- 23.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.