Bilateral magnetic stimulation of the phrenic nerves from an anterolateral approach.
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We investigated whether bilateral magnetic stimulation of the phrenic nerves from an anterolateral approach (BAMPS) could combine the reproducibility and ease of use of cervical magnetic stimulation (CMS) with the specificity of bilateral electrical stimulation (BES) and whether it could be used in supine subjects. We placed two double 43-mm coils over the phrenic nerves in the neck. BAMPS produced supramaximal phrenic stimulation by electromyogram (EMG) assessment in six of seven subjects. There was no significant difference in the twitch gastric pressure/twitch esophageal pressure ratio (twitch Pgas/Pes) between BAMPS (1.2) and BES (1.3). Both differed from CMS (0.9, p < 0.001). The effect of a change in posture on twitch transdiaphragmatic pressure (TwPdi) and Pgas/Pes ratio was the same for BAMPS and BES. In normal subjects and patients BAMPS correlated significantly with BES (r = 0.97), maximal sniffs (r = 0.85), and CMS (r = 0.92). The mean difference between BAMPS and BES was 0.3 cm H2O (SD = 2.3). Two-minute maximal isocapnic ventilation produced a 19% fall in TwPdi elicited by BAMPS. BAMPS is easy, well tolerated and can be used in the supine subject. TwPdi and partitioning of Pes and Pgas were very close for BAMPS and BES, suggesting similar specificity for the diaphragm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Improved technique for estimating pleural pressure from esophageal balloons
Milic-Emili, J., Mead, J., Turner, J. M., & Glauser, E. M. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.2.207 · Cited by 863
Exercise‐induced diaphragmatic fatigue in healthy humans.
Johnson, B. D., Babcock, M. A., Suman, O. E., & Dempsey, J. A. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019477 · Cited by 364
Similowski, T., Fleury, B., Launois, S., Cathala, H. P., Bouche, P., & Derenne, J. P. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.4.1311 · Cited by 324
The Maximal Sniff in the Assessment of Diaphragm Function in Man
Miller, J. M., Moxham, J., & Green, M. (1985) · Clinical Science · doi:10.1042/cs0690091 · Cited by 263
Self-citationFatigue of inspiratory muscles and their synergic behavior
Roussos, C., Fixley, M., Gross, D., & Macklem, P. T. (1979) · Journal of Applied Physiology · doi:10.1152/jappl.1979.46.5.897 · Cited by 259
Assessment of human diaphragm strength and activation using phrenic nerve stimulation
Bellemare, F., & Bigland-Ritchie, B. (1984) · Respiration Physiology · doi:10.1016/0034-5687(84)90003-3 · Cited by 229
Detection of diaphragmatic fatigue in man by phrenic stimulation
Aubier, M., Farkas, G., De Troyer, A., Mozes, R., & Roussos, C. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.50.3.538 · Cited by 209
Technical and Practical Aspects of Magnetic Nerve Stimulation
Jalinous, R. (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199101000-00004 · Cited by 203
Contractile properties and fatigue of the diaphragm in man.
Moxham, J., Morris, A. J., Spiro, S. G., Edwards, R. H., & Green, M. (1981) · Thorax · doi:10.1136/thx.36.3.164 · Cited by 141
Self-citationWragg, S., Aquilina, R., Moran, J., Ridding, M. C., Hamnegärd, C. H., Fearn, T., Green, M., & Moxham, J. (1994) · European Respiratory Journal · doi:10.1183/09031936.94.07101788 · Cited by 121
Self-citation
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Dres, M., Dubé, B.-P., Mayaux, J., Delemazure, J., Reuter, D., Brochard, L., Similowski, T., & Demoule, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201602-0367oc · Cited by 539
Demoule, A., Jung, B., Prodanovic, H., Molinari, N., Chanques, G., Coirault, C., Matecki, S., Duguet, A., Similowski, T., & Jaber, S. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201209-1668oc · Cited by 459
Exercise-induced respiratory muscle fatigue: implications for performance
Romer, L. M., & Polkey, M. I. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01157.2007 · Cited by 352
Self-citationHermans, G., Agten, A., Testelmans, D., Decramer, M., & Gayan-Ramirez, G. (2010) · Critical Care · doi:10.1186/cc9094 · Cited by 274
Effect of Bronchoscopic Lung Volume Reduction on Dynamic Hyperinflation and Exercise in Emphysema
Hopkinson, N. S., Toma, T. P., Hansell, D. M., Goldstraw, P., Moxham, J., Geddes, D. M., & Polkey, M. I. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200407-961oc · Cited by 243
Self-citationWatson, A. C., Hughes, P. D., Louise Harris, M., Hart, N., Ware, R. J., Wendon, J., Green, M., & Moxham, J. (2001) · Critical Care Medicine · doi:10.1097/00003246-200107000-00005 · Cited by 234
“Phrenic nerve stimulation was achieved with two 43-mm magnetic coils (Magstim, Dyfed, Wales) placed firmly anterolaterally on either side of the neck, lateral to the cricoid cartilage (9).”
BackgroundMethodResultSelf-citationDiaphragm Dysfunction: Diagnostic Approaches and Management Strategies
Dubé, B.-P., & Dres, M. (2016) · Journal of Clinical Medicine · doi:10.3390/jcm5120113 · Cited by 230
Clinical review: The ABC of weaning failure - a structured approach
Heunks, L. M., & van der Hoeven, J. G. (2010) · Critical Care · doi:10.1186/cc9296 · Cited by 220
“Laghi and colleagues [41] found that, in a heterogeneous group of mechanically ventilated patients (± 29 days), transdiaphragmatic pressure obtained after magnetic stimulation of the phrenic nerves was only approximately 35% compared with healthy subjects [42].”
Dubé, B.-P., Dres, M., Mayaux, J., Demiri, S., Similowski, T., & Demoule, A. (2017) · Thorax · doi:10.1136/thoraxjnl-2016-209459 · Cited by 216
Man, W. D.-C. (2003) · Thorax · doi:10.1136/thorax.58.8.665 · Cited by 160
Influence of acute lung volume change on contractile properties of human diaphragm
Polkey, M. I., Hamnegård, C.-H., Hughes, P. D., Rafferty, G. F., Green, M., & Moxham, J. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.4.1322 · Cited by 63
“pBAMPS has the advantage of minimizing twitch potentiation but, in addition, is also selective for the diaphragm (28), allowing the investigator to be confident of supramaximality by assessment of the Pditw.”
InfluentialSelf-citationInspiratory muscles do not limit maximal incremental exercise performance in healthy subjects
Romer, L. M., Miller, J. D., Haverkamp, H. C., Pegelow, D. F., & Dempsey, J. A. (2007) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2006.10.008 · Cited by 48
Lozano-García, M., Sarlabous, L., Moxham, J., Rafferty, G. F., Torres, A., Jané, R., & Jolley, C. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-35024-z · Cited by 32
Self-citation
Metadata
- Authors
- Mills, G. H., Kyroussis, D., Hamnegard, C. H., Polkey, M. I., Green, M., & Moxham, J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-10
- Volume
- 154
- Issue
- 4
- Pages
- 1099-1105
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2089196135
- Cited by
- 183
- References
- 15
- FWCI
- 6.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.