The Comet-tail Artifact: An Ultrasound Sign of Alveolar-Interstitial Syndrome
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Can ultrasound be of any help in the diagnosis of alveolar-interstitial syndrome? In a prospective study, we examined 250 consecutive patients in a medical intensive care unit: 121 patients with radiologic alveolar-interstitial syndrome (disseminated to the whole lung, n = 92; localized, n = 29) and 129 patients without radiologic evidence of alveolar-interstitial syndrome. The antero-lateral chest wall was examined using ultrasound. The ultrasonic feature of multiple comet-tail artifacts fanning out from the lung surface was investigated. This pattern was present all over the lung surface in 86 of 92 patients with diffuse alveolar-interstitial syndrome (sensitivity of 93.4%). It was absent or confined to the last lateral intercostal space in 120 of 129 patients with normal chest X-ray (specificity of 93.0%). Tomodensitometric correlations showed that the thickened sub-pleural interlobular septa, as well as ground-glass areas, two lesions present in acute pulmonary edema, were associated with the presence of the comet-tail artifact. In conclusion, presence of the comet-tail artifact allowed diagnosis of alveolar-interstitial syndrome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Bedside Ultrasound Sign Ruling Out Pneumothorax in the Critically III
Lichtenstein, D. A., & Menu, Y. (1995) · Chest · doi:10.1378/chest.108.5.1345 · Cited by 787
Self-citationLaing, W. A., Ogren, W. L., & Hageman, R. H. (1974) · Plant Physiology · doi:10.1104/pp.54.5.678 · Cited by 662
Pneumothorax: evaluation by ultrasound—preliminary results
Wernecke, K., Galanski, M., Peters, P. E., & Hansen, J. (1987) · Journal of Thoracic Imaging · doi:10.1097/00005382-198704000-00015 · Cited by 163
Rantanen, N. W. (1986) · Veterinary Clinics of North America Equine Practice · doi:10.1016/s0749-0739(17)30732-0 · Cited by 132
Dorne, H. L. (1986) · Radiology · doi:10.1148/radiology.158.1.3510027 · Cited by 64
Cited by
International evidence-based recommendations for point-of-care lung ultrasound
International Liaison Committee on Lung Ultrasound (ILC-LUS) for the International Consensus Conference on Lung Ultrasound (ICC-LUS), Volpicelli, G., Elbarbary, M., Blaivas, M., Lichtenstein, D. A., Mathis, G., Kirkpatrick, A. W., Melniker, L., Gargani, L., Noble, V. E., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2513-4 · Cited by 2,874
Self-citationRelevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure*: The BLUE Protocol
Lichtenstein, D. A., & Mezière, G. A. (2008) · Chest · doi:10.1378/chest.07-2800 · Cited by 2,068
Self-citationMoore, C. L., & Copel, J. A. (2011) · New England Journal of Medicine · doi:10.1056/nejmra0909487 · Cited by 1,788
Lichtenstein, D., Goldstein, I., Mourgeon, E., Cluzel, P., Grenier, P., & Rouby, J.-J. (2004) · Anesthesiology · doi:10.1097/00000542-200401000-00006 · Cited by 1,077
Self-citationBedside Ultrasound Assessment of Positive End-Expiratory Pressure–induced Lung Recruitment
Bouhemad, B., Brisson, H., Le-Guen, M., Arbelot, C., Lu, Q., & Rouby, J.-J. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201003-0369oc · Cited by 735
Lung ultrasound in the critically ill
Lichtenstein, D. A. (2014) · Annals of Intensive Care · doi:10.1186/2110-5820-4-1 · Cited by 711
Self-citationBLUE-Protocol and FALLS-Protocol
Lichtenstein, D. A. (2015) · Chest · doi:10.1378/chest.14-1313 · Cited by 691
Self-citationThe RUSH Exam: Rapid Ultrasound in SHock in the Evaluation of the Critically lll
Perera, P., Mailhot, T., Riley, D., & Mandavia, D. (2010) · Emergency Medicine Clinics of North America · doi:10.1016/j.emc.2009.09.010 · Cited by 671
Ultrasound diagnosis of occult pneumothorax*
Lichtenstein, D. A., Mezière, G., Lascols, N., Biderman, P., Courret, J.-P., Gepner, A., Goldstein, I., & Tenoudji-Cohen, M. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000164542.86954.b4 · Cited by 632
Self-citation“Ultrasound Comet-Tail Images”: A Marker Of Pulmonary Edema
Agricola, E., Bove, T., Oppizzi, M., Marino, G., Zangrillo, A., Margonato, A., & Picano, E. (2005) · Chest · doi:10.1378/chest.127.5.1690 · Cited by 597
Copetti, R., Soldati, G., & Copetti, P. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-16 · Cited by 555
Soummer, A., Perbet, S., Brisson, H., Arbelot, C., Constantin, J.-M., Lu, Q., & Rouby, J.-J. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31824e68ae · Cited by 519
Lung Ultrasound for Critically Ill Patients
Mojoli, F., Bouhemad, B., Mongodi, S., & Lichtenstein, D. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201802-0236ci · Cited by 513
Self-citationUltrasound diagnosis of alveolar consolidation in the critically ill
Lichtenstein, D. A., Lascols, N., Mezière, G., & Gepner, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2075-6 · Cited by 512
Self-citationThe comet-tail artifact: an ultrasound sign ruling out pneumothorax
Lichtenstein, D., Mezière, G., Biderman, P., & Gepner, A. (1999) · Intensive Care Medicine · doi:10.1007/s001340050862 · Cited by 466
Self-citationIs There a Role for Lung Ultrasound During the COVID‐19 Pandemic?
Soldati, G., Smargiassi, A., Inchingolo, R., Buonsenso, D., Perrone, T., Briganti, D. F., Perlini, S., Torri, E., Mariani, A., Mossolani, E. E., et al. (2020) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15284 · Cited by 447
Lichtenstein, D., & Mezière, G. (1998) · Intensive Care Medicine · doi:10.1007/s001340050771 · Cited by 412
Self-citationLung Ultrasound-Implemented Diagnosis of Acute Decompensated Heart Failure in the ED
Pivetta, E., Goffi, A., Lupia, E., Tizzani, M., Porrino, G., Ferreri, E., Volpicelli, G., Balzaretti, P., Banderali, A., Iacobucci, A., et al. (2015) · Chest · doi:10.1378/chest.14-2608 · Cited by 405
Lichtenstein, D. A., Mezière, G. A., Lagoueyte, J.-F., Biderman, P., Goldstein, I., & Gepner, A. (2009) · Chest · doi:10.1378/chest.09-0001 · Cited by 401
Self-citationThe “lung pulse”: an early ultrasound sign of complete atelectasis
Lichtenstein, D. A., Lascols, N., Prin, S., & Mezière, G. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1930-9 · Cited by 372
Self-citationNew International Guidelines and Consensus on the Use of Lung Ultrasound
Demi, L., Wolfram, F., Klersy, C., De Silvestri, A., Ferretti, V. V., Muller, M., Miller, D., Feletti, F., Wełnicki, M., Buda, N., et al. (2023) · Journal of Ultrasound in Medicine · doi:10.1002/jum.16088 · Cited by 328
Lung ultrasound: a new tool for the cardiologist
Gargani, L. (2011) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-9-6 · Cited by 322
Maw, A. M., Hassanin, A., Ho, P. M., McInnes, M. D. F., Moss, A., Juarez-Colunga, E., Soni, N. J., Miglioranza, M. H., Platz, E., DeSanto, K., et al. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.0703 · Cited by 309
Ultrasound in the management of thoracic disease
Lichtenstein, D. A. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000260674.60761.85 · Cited by 307
Self-citationLung Ultrasound in Respiratory Distress Syndrome: A Useful Tool for Early Diagnosis
Copetti, R., Cattarossi, L., Macagno, F., Violino, M., & Furlan, R. (2008) · Neonatology · doi:10.1159/000113059 · Cited by 287
Coiro, S., Rossignol, P., Ambrosio, G., Carluccio, E., Alunni, G., Murrone, A., Tritto, I., Zannad, F., & Girerd, N. (2015) · European Journal of Heart Failure · doi:10.1002/ejhf.344 · Cited by 281
Gargani, L., Frassi, F., Soldati, G., Tesorio, P., Gheorghiade, M., & Picano, E. (2008) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2007.10.009 · Cited by 272
Cortellaro, F., Colombo, S., Coen, D., & Duca, P. G. (2012) · Emergency Medicine Journal · doi:10.1136/emj.2010.101584 · Cited by 263
The ‘Double Lung Point’: An Ultrasound Sign Diagnostic of Transient Tachypnea of the Newborn
Copetti, R., & Cattarossi, L. (2007) · Neonatology · doi:10.1159/000097454 · Cited by 260
Transthoracic Sonography of Diffuse Parenchymal Lung Disease: The Role of Comet Tail Artifacts
Reißig, A., & Kroegel, C. (2003) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2003.22.2.173 · Cited by 223
“Pulmonary fibrosis (26) Idiopathic pulmonary fibrosis (17); collagen Histologically established, HRCT (13); BAL, disorders (7); extrinsic allergic alveolitis (1); HRCT, serologic tests (5); HRCT, serologic acute interstitial pneumonia (1) tests (8) Sarcoidosis (7) Sarcoidosis stage II (5); sarcoidosis stage III (2) Hi…”
BackgroundAcute heart failure and cardiogenic shock: a multidisciplinary practical guidance
Mebazaa, A., Tolppanen, H., Mueller, C., Lassus, J., DiSomma, S., Baksyte, G., Cecconi, M., Choi, D. J., Cohen Solal, A., Christ, M., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4041-5 · Cited by 220
“The presence of at least three B-lines per field of scan seen longitudinally between two ribs using a phased array or sector probe, with a distance between two B-lines of\7 ± 1 mm, is the current criteria for abnormality [32].”
BackgroundThe role of ultrasound lung artifacts in the diagnosis of respiratory diseases
Soldati, G., Demi, M., Smargiassi, A., Inchingolo, R., & Demi, L. (2019) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2019.1565997 · Cited by 206
Enghard, P., Rademacher, S., Nee, J., Hasper, D., Engert, U., Jörres, A., & Kruse, J. M. (2015) · Critical Care · doi:10.1186/s13054-015-0756-5 · Cited by 202
“Using lung ultrasound to detect so-called B lines proved to be a useful diagnostic tool in diagnosing pulmonary edema in the emergency medicine setting and in animal studies, where the detection and quantification of so-called B lines showed correlation with clinical assessment, radiologic findings, natriuretic peptid…”
Frassi, F., Gargani, L., Tesorio, P., Raciti, M., Mottola, G., & Picano, E. (2007) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2007.07.003 · Cited by 183
“A lung comet was defined as a hyperechogenic, coherent bundle with a narrow basis, spreading from the transducer to the further border of the screen.(9) The ULCs described here extend to the edge of the screen and arise only from the pleural line (Fig.”
BackgroundKristensen, M. S., Teoh, W. H., Graumann, O., & Laursen, C. B. (2014) · Insights into Imaging · doi:10.1007/s13244-014-0309-5 · Cited by 179
“aging, 21–28 % have multiple B-lines in the lower lateral intercostal space [2, 109, 138].”
BackgroundModified Lung Ultrasound Score for Assessing and Monitoring Pulmonary Aeration
Mongodi, S., Bouhemad, B., Orlando, A., Stella, A., Tavazzi, G., Via, G., Iotti, G., Braschi, A., & Mojoli, F. (2017) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0042-120260 · Cited by 178
“Although air is an obstacle to the passage of ultrasound, artefacts from the pleura permit a distinction between normal and pathological patterns [7].”
BackgroundLung ultrasound in bronchiolitis: comparison with chest X-ray
Caiulo, V. A., Gargani, L., Caiulo, S., Fisicaro, A., Moramarco, F., Latini, G., & Picano, E. (2011) · European Journal of Pediatrics · doi:10.1007/s00431-011-1461-2 · Cited by 177
“In the presence of pathological processes that lead to thickening of peripheral interlobular septa, A-lines are replaced by other comet-tail artifacts, perpendicular to the pleural line, called B-lines (also known as ultrasound lung comets) [16].”
BackgroundLung Ultrasound in the Critically Ill Neonate
A. Lichtenstein, D., & Mauriat, P. (2012) · Current Pediatric Reviews · doi:10.2174/157339612802139389 · Cited by 162
“In the adult, ultrasound has proved more accurate than radiography (Tables 1 and 2) and nearly as accurate as CT [35, 36, 38, 42-45, 55], and superior on occasion [56].”
BackgroundMethodProsen, G., Klemen, P., Strnad, M., & Grmec, Š. (2011) · Critical Care · doi:10.1186/cc10140 · Cited by 161
“[9] first described comet-tail signs or B lines indicating interstitial pulmonary edema, and Lichtenstein and Mezière [10] described a systematic approach to lung ultrasound.”
BackgroundRole of thoracic ultrasound in the assessment of pleural and pulmonary diseases
Sperandeo, M., Filabozzi, P., Varriale, A., Carnevale, V., Piattelli, M. L., Sperandeo, G., Brunetti, E., & Decuzzi, M. (2008) · Journal of Ultrasound · doi:10.1016/j.jus.2008.02.001 · Cited by 87
Kuroda, Y., Kaneko, T., Yoshikawa, H., Uchiyama, S., Nagata, Y., Matsushita, Y., Hiki, M., Minamino, T., Takahashi, K., Daida, H., et al. (2023) · PLOS ONE · doi:10.1371/journal.pone.0281127 · Cited by 36
Metadata
- Authors
- LICHTENSTEIN, D., MÉZIÈRE, G., BIDERMAN, P., GEPNER, A., & BARRÉ, O.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-11-01
- Volume
- 156
- Issue
- 5
- Pages
- 1640-1646
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2119638066
- Cited by
- 1,075
- References
- 5
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.