Long-term Acceptance of Continuous Positive Airway Pressure in Obstructive Sleep Apnea
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
We studied the long-term acceptability of nasal continuous positive airway pressure (CPAP) treatment in 168 consecutive patients, 147 with obstructive sleep apnea (OSA) and 21 with snoring. Follow-up was between 1.5 and 78 months. At latest follow-up 107 of 168 (64%) were still using CPAP. Acceptance of CPAP was least for patients with snoring alone (6 of 21 persisted) and best for patients with both excessive daytime somnolence and severe hypoxemia (minimum SaO2 less than 75%), of whom 40 of 45 (89%) persisted with treatment. Patients with excessive daytime somnolence but without severe hypoxemia were less tolerant of CPAP (39 of 71, 55%, persisted) than patients with no symptoms of excessive somnolence but with severe hypoxemia (21 of 30, 70%, persisted). The most common reasons for discontinuing CPAP were intolerance of the mask (26 of 61), the inconvenience of treatment (16 of 61), and the lack of symptomatic benefit from treatment (10 of 61). We concluded that long-term acceptance of CPAP was difficult to predict in advance but that it was most likely in patients with the most severe sleep apnea. Because intolerance of the mask and inconvenience were the most common reasons for ceasing treatment, improvements in the design of CPAP systems and careful patient training may improve the acceptability of CPAP substantially.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mortality and Apnea Index in Obstructive Sleep Apnea
He, J., Kryger, M. H., Zorick, F. J., Conway, W., & Roth, T. (1988) · Chest · doi:10.1378/chest.94.1.9 · Cited by 1,514
Katan, M., & Van De Bovenkamp, P. (1987) · The Lancet · doi:10.1016/s0140-6736(87)91641-2 · Cited by 964
Gould, G. A., Whyte, K. F., Rhind, G. B., Airlie, M. A. A., Catterall, J. R., Shapiro, C. M., & Douglas, N. J. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/137.4.895 · Cited by 480
Patient Compliance with Nasal CPAP Therapy for Sleep Apnea
Sanders, M. H., Gruendl, C. A., & Rogers, R. M. (1986) · Chest · doi:10.1378/chest.90.3.330 · Cited by 192
Positive Nasal Airway Pressure Eliminates Snoring As Well As Obstructive Sleep Apnea
Berry, R. B., & Block, A. J. (1984) · CHEST Journal · doi:10.1378/chest.85.1.15 · Cited by 109
Nasal CPAP Effect on Patterns of Sleep Apnea
SANDERS, M. H. (1984) · CHEST Journal · doi:10.1378/chest.86.6.839 · Cited by 91
Management of obstructive sleep apnea: Comparison of various treatment modalities
Katsantonis, G. P., Branham, G. H., Chambers, G., Schweitzer, P. K., & Walsh, J. K. (1988) · The Laryngoscope · doi:10.1288/00005537-198803000-00013 · Cited by 79
Severe obstructive sleep apnoea treated with long term nasal continuous positive airway pressure.
Frith, R., & CANT, B. R. (1985) · Thorax · doi:10.1136/thx.40.1.45 · Cited by 43
Cited by
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339
Long-term Use of CPAP Therapy for Sleep Apnea/Hypopnea Syndrome
McARDLE, N., DEVEREUX, G., HEIDARNEJAD, H., ENGLEMAN, H. M., MACKAY, T. W., & DOUGLAS, N. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9807111 · Cited by 820
Ferguson, K. A., Ono, T., Lowe, A. A., Keenan, S. P., & Fleetham, J. A. (1996) · Chest · doi:10.1378/chest.109.5.1269 · Cited by 495
Improving CPAP use by patients with the sleep apnoea/hypopnoea syndrome (SAHS)
Engleman, H. M., & Wild, M. R. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2001.0197 · Cited by 473
Side Effects of Nasal Continuous Positive Airway Pressure in Sleep Apnea Syndrome
Pépin, J. L., Leger, P., Veale, D., Langevin, B., Robert, D., & Lévy, P. (1995) · Chest · doi:10.1378/chest.107.2.375 · Cited by 422
Wright, J., Johns, R., Watt, I., Melville, A., & Sheldon, T. (1997) · BMJ · doi:10.1136/bmj.314.7084.851 · Cited by 414
Kribbs, N. B., Pack, A. I., Kline, L. R., Getsy, J. E., Schuett, J. S., Henry, J. N., Maislin, G., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.5.1162 · Cited by 395
Long-term Compliance Rates to Continuous Positive Airway Pressure in Obstructive Sleep Apnea
Sin, D. D., Mayers, I., Man, G. C. W., & Pawluk, L. (2002) · Chest · doi:10.1378/chest.121.2.430 · Cited by 379
Wozniak, D. R., Lasserson, T. J., & Smith, I. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007736.pub2 · Cited by 379
Nasal CPAP: an objective evaluation of patient compliance.
Reeves-Hoche, M. K., Meck, R., & Zwillich, C. W. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.1.8111574 · Cited by 357
Ohayon, M. M., Guilleminault, C., Priest, R. G., & Caulet, M. (1997) · BMJ · doi:10.1136/bmj.314.7084.860 · Cited by 303
PÉPIN, J. L., KRIEGER, J., RODENSTEIN, D., CORNETTE, A., SFORZA, E., DELGUSTE, P., DESCHAUX, C., GRILLIER, V., & LÉVY, P. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.4.9802027 · Cited by 274
The Pharyngeal Critical Pressure
Gold, A. R., & Schwartz, A. R. (1996) · Chest · doi:10.1378/chest.110.4.1077 · Cited by 273
Quality of Life in Patients with Obstructive Sleep Apnea
D’Ambrosio, C., Bowman, T., & Mohsenin, V. (1999) · Chest · doi:10.1378/chest.115.1.123 · Cited by 266
Positive Airway Pressure Treatment for Obstructive Sleep Apnea
Kakkar, R. K., & Berry, R. B. (2007) · Chest · doi:10.1378/chest.06-2432 · Cited by 258
Liu, Y., Lowe, A. A., Orthodont, D., Fleetham, J. A., & Park, Y.-C. (2001) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1067/mod.2001.118782 · Cited by 208
Efficacy of a Herbst mandibular advancement device in obstructive sleep apnea.
Eveloff, S. E., Rosenberg, C. L., Carlisle, C. C., & Millman, R. P. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.4.8143054 · Cited by 210
Tan, Y. K. (2002) · The European Journal of Orthodontics · doi:10.1093/ejo/24.3.239 · Cited by 206
“40–50 per cent (Waldhorn et al., 1990; Rolfe et al., 1991), but the milder the symptoms of OSA, the less likely were the subjects to accept nCPAP (Engleman et al.”
BackgroundLong-Term Compliance With CPAP Therapy in Obstructive Sleep Apnea Patients and in Snorers
Krieger, J., Kurtz, D., Petiau, C., Sforza, E., & Trautmann, D. (1996) · Sleep · doi:10.1093/sleep/19.suppl_9.s136 · Cited by 201
“gated; however, an AHI > 15 was the criterion in several studies (6,10,11).”
BackgroundResultInfluentialRisk of traffic accidents in patients with sleep-disordered breathing: reduction with nasal CPAP
Cassel, W., Ploch, T., Becker, C., Dugnus, D., Peter, J., & von Wichert, P. (1996) · European Respiratory Journal · doi:10.1183/09031936.96.09122606 · Cited by 201
“The noncompliance rate of 9% (7 out of 78) reported here is relatively low when compared to other studies [29, 30], in which higher rates of noncompliance have been reported, up to 36% in one study [31].”
ResultContinuous Versus Bilevel Positive Airway Pressure for Obstructive Sleep Apnea
Reeves-Hoché, M. K., Hudgel, D. W., Meck, R., Witteman, R., Ross, A., & Zwillich, C. W. (1995) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.151.2.7842204 · Cited by 192
Zozula, R., & Rosen, R. (2001) · Current Opinion in Pulmonary Medicine · doi:10.1097/00063198-200111000-00005 · Cited by 189
Hakama, M., Pukkala, E., HeikkilÄ, M., & Kallio, M. (1997) · BMJ · doi:10.1136/bmj.314.7084.864 · Cited by 161
Smith, I., & Lasserson, T. J. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub3 · Cited by 151
Abuzaid, A. S., Al Ashry, H. S., Elbadawi, A., Ld, H., Saad, M., Elgendy, I. Y., Elgendy, A., Mahmoud, A. N., Mentias, A., Barakat, A., et al. (2017) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2017.05.042 · Cited by 140
JANSON, C., NÖGES, E., SVEDBERG-BRANDT, S., & LINDBERG, E. (2000) · Respiratory Medicine · doi:10.1053/rmed.1999.0703 · Cited by 121
Turino, C., de Batlle, J., Woehrle, H., Mayoral, A., Castro-Grattoni, A. L., Gómez, S., Dalmases, M., Sánchez-de-la-Torre, M., & Barbé, F. (2017) · European Respiratory Journal · doi:10.1183/13993003.01128-2016 · Cited by 115
Deutsch, P. A., Simmons, M. S., & Wallace, J. M. (2006) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26508 · Cited by 103
Gay, P. C., Herold, D. L., & Olson, E. J. (2003) · Sleep · doi:10.1093/sleep/26.7.864 · Cited by 90
A Pilot Trial of a Telecommunications System in Sleep Apnea Management
DeMolles, D. A., Sparrow, D., Gottlieb, D. J., & Friedman, R. (2004) · Medical Care · doi:10.1097/01.mlr.0000132353.99209.fe · Cited by 88
Split-night versus full-night studies for sleep apnoea/hypopnoea syndrome
McArdle, N., Grove, A., Devereux, G., Mackay-Brown, L., Mackay, T., & Douglas, N. J. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.15d08.x · Cited by 84
Deng, T., Wang, Y., Sun, M., & Chen, B. (2013) · Sleep and Breathing · doi:10.1007/s11325-012-0766-3 · Cited by 50
Pépin, J.-L., Muir, J.-F., Gentina, T., Dauvilliers, Y., Tamisier, R., Sapene, M., Escourrou, P., Fleury, B., Philip-Joet, F., Philip, P., et al. (2009) · Chest · doi:10.1378/chest.08-2646 · Cited by 46
Khanna, R. (2003) · Sleep Medicine · doi:10.1016/s1389-9457(03)00063-7 · Cited by 46
Zhu, K., Roisman, G., Aouf, S., & Escourrou, P. (2015) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.4844 · Cited by 46
Goh, K. J., Soh, R. Y., Leow, L. C., Toh, S. T., Song, P. R., Hao, Y., Lee, K. C. H., Tan, G. L., & Ong, T. H. (2019) · Respirology · doi:10.1111/resp.13396 · Cited by 45
Means, M. K., & Edinger, J. D. (2007) · Behavioral Sleep Medicine · doi:10.1080/15402000701190572 · Cited by 39
Falcone, V. A., Damiani, M. F., Quaranta, V. N., Capozzolo, A., & Resta, O. (2014) · Respiratory Care · doi:10.4187/respcare.02491 · Cited by 33
Metadata
- Authors
- Rolfe, I., Olson, L. G., & Saunders, N. A.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-11
- Volume
- 144
- Issue
- 5
- Pages
- 1130-1133
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W1978595253
- Cited by
- 192
- References
- 8
- FWCI
- 4.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.