Accuracy of two ear oximeters at rest and during exercise in pulmonary patients.
The DOI matches its OpenAlex record.
Abstract
The accuracy of 2 ear oximeters (Hewlett-Packard 47201A and Biox IIA) was evaluated at rest and during exercise in 116 pulmonary patients. Ear oximetry measurements were compared with arterial oxygen saturation (SaO2) measured from simultaneous arterial blood samples. When used according to the manufacturer's instructions for stabilization during exercise testing, both oximeters demonstrated comparable accuracy in estimating arterial blood SaO2 both at rest and during exercise in these patients (95% confidence limits, 2 SEE = +/- 4 to 5%). The oximeters were more accurate in measuring a change in SaO2 from a previous reading (95% confidence limits, 2 SEE = +/- 2.5 to 3.5%). COHgb levels greater than 4% and dark skin pigmentation appeared to decrease the accuracy of ear oximetry measurements. Within the limitations of accuracy, both ear oximeters may be useful for clinical exercise testing in pulmonary patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
ERS statement on standardisation of cardiopulmonary exercise testing in chronic lung diseases
Radtke, T., Crook, S., Kaltsakas, G., Louvaris, Z., Berton, D., Urquhart, D. S., Kampouras, A., Rabinovich, R. A., Verges, S., Kontopidis, D., et al. (2019) · European Respiratory Review · doi:10.1183/16000617.0101-2018 · Cited by 338
Jubran, A., & Tobin, M. J. (1990) · Chest · doi:10.1378/chest.97.6.1420 · Cited by 296
Six-Minute Walk, Maximal Exercise Tests: Reproducibility in Fibrotic Interstitial Pneumonia
Eaton, T., Young, P., Milne, D., & Wells, A. U. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200405-578oc · Cited by 274
Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N. (1998) · Heart & Lung · doi:10.1016/s0147-9563(98)90086-3 · Cited by 243
Shi, C., Goodall, M., Dumville, J., Hill, J., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · doi:10.1101/2022.02.16.22271062 · Cited by 158
“• pulmonary/respiratory conditions including COVID-19,[38,49,53,54,60,62]”
BackgroundInfluentialRies, A. L., Prewitt, L. M., & Johnson, J. J. (1989) · Chest · doi:10.1378/chest.96.2.287 · Cited by 145
Self-citationReliability of noninvasive oximetry in black subjects during exercise and hypoxia
Zeballos, R. J., & Weisman, I. M. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.6.1240 · Cited by 108
Effect of skin pigmentation on pulse oximetry accuracy in the emergency department
Adler, J. N., Hughes, L. A., Vtvilecchia, R., & Jr., C. A. C. (1998) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1998.tb02772.x · Cited by 102
Metadata
- Authors
- Ries, A. L., Farrow, J. T., & Clausen, J. L.
- Venue
- PubMed
- Publisher
- National Institutes of Health
- Published
- 1985-09-01
- Volume
- 132
- Issue
- 3
- Pages
- 685-9
- OpenAlex
- W1676735874
- Cited by
- 106
- References
- 0
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.