Exhaled Breath Profiling Enables Discrimination of Chronic Obstructive Pulmonary Disease and Asthma
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
RATIONALE: Chronic obstructive pulmonary disease (COPD) and asthma can exhibit overlapping clinical features. Exhaled air contains volatile organic compounds (VOCs) that may qualify as noninvasive biomarkers. VOC profiles can be assessed using integrative analysis by electronic nose, resulting in exhaled molecular fingerprints (breathprints). OBJECTIVES: We hypothesized that breathprints by electronic nose can discriminate patients with COPD and asthma. METHODS: Ninety subjects participated in a cross-sectional study: 30 patients with COPD (age, 61.6 +/- 9.3 years; FEV(1), 1.72 +/- 0.69 L), 20 patients with asthma (age, 35.4 +/- 15.1 years; FEV(1) 3.32 +/- 0.86 L), 20 nonsmoking control subjects (age, 56.7 +/- 9.3 years; FEV(1), 3.44 +/- 0.76 L), and 20 smoking control subjects (age, 56.1 +/- 5.9 years; FEV(1), 3.58 +/- 0.78). After 5 minutes of tidal breathing through an inspiratory VOC filter, an expiratory vital capacity was collected in a Tedlar bag and sampled by electronic nose. Breathprints were analyzed by discriminant analysis on principal component reduction resulting in cross-validated accuracy values (accuracy). Repeatability and reproducibility were assessed by measuring samples in duplicate by two devices. MEASUREMENTS AND MAIN RESULTS: Breathprints from patients with asthma were separated from patients with COPD (accuracy 96%; P < 0.001), from nonsmoking control subjects (accuracy, 95%; P < 0.001), and from smoking control subjects (accuracy, 92.5%; P < 0.001). Exhaled breath profiles of patients with COPD partially overlapped with those of asymptomatic smokers (accuracy, 66%; P = 0.006). Measurements were repeatable and reproducible. CONCLUSIONS: Molecular profiling of exhaled air can distinguish patients with COPD and asthma and control subjects. Our data demonstrate a potential of electronic noses in the differential diagnosis of obstructive airway diseases and in the risk assessment in asymptomatic smokers. Clinical trial registered with www.trialregister.nl (NTR 1282).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
Rabe, K. F., Hurd, S., Anzueto, A., Barnes, P. J., Buist, S. A., Calverley, P., Fukuchi, Y., Jenkins, C., Rodriguez-Roisin, R., van Weel, C., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200703-456so · Cited by 4,925 · cited 5×
“Chronic obstructive pulmonary disease (COPD) and asthma are obstructive airways diseases that pose a major public health problem (1, 2).”
BackgroundMethodInfluentialGlobal strategy for asthma management and prevention: GINA executive summary
Bateman, E. D., Hurd, S. S., Barnes, P. J., Bousquet, J., Drazen, J. M., FitzGerald, M., Gibson, P., Ohta, K., O'Byrne, P., Pedersen, S. E., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00138707 · Cited by 3,203
(2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.1.ats11-99 · Cited by 2,467
The European Community Respiratory Health Survey
Burney, P., Luczynska, C., Chinn, S., & Jarvis, D. (1994) · European Respiratory Journal · doi:10.1183/09031936.94.07050954 · Cited by 1,996
Quantitative Analysis of Urine Vapor and Breath by Gas-Liquid Partition Chromatography
Pauling, L., Robinson, A. B., Teranishi, R., & Cary, P. (1971) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.68.10.2374 · Cited by 1,025
Endotyping asthma: new insights into key pathogenic mechanisms in a complex, heterogeneous disease
Anderson, G. P. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61452-x · Cited by 999
Exhaled Markers of Pulmonary Disease
KHARITONOV, S. A., & BARNES, P. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2009041 · Cited by 844
Human exhaled air analytics: biomarkers of diseases
Buszewski, B., Kęsy, M., Ligor, T., & Amann, A. (2007) · Biomedical Chromatography · doi:10.1002/bmc.835 · Cited by 792
Weston, A. D., & Hood, L. (2004) · Journal of Proteome Research · doi:10.1021/pr0499693 · Cited by 731
Cited by
A European Respiratory Society technical standard: exhaled biomarkers in lung disease
Horváth, I., Barnes, P. J., Loukides, S., Sterk, P. J., Högman, M., Olin, A.-C., Amann, A., Antus, B., Baraldi, E., Bikov, A., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00965-2016 · Cited by 638
Self-citationAdvances in Electronic-Nose Technologies Developed for Biomedical Applications
Wilson, A. D., & Baietto, M. (2011) · Sensors · doi:10.3390/s110101105 · Cited by 400
Solid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
Electronic Nose and Its Applications: A Survey
Karakaya, D., Ulucan, O., & Turkan, M. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-019-1212-9 · Cited by 353
The versatile use of exhaled volatile organic compounds in human health and disease
Boots, A. W., van Berkel, J. J. B. N., Dallinga, J. W., Smolinska, A., Wouters, E. F., & van Schooten, F. J. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/2/027108 · Cited by 352
Application of ’omics technologies to biomarker discovery in inflammatory lung diseases
Wheelock, C. E., Goss, V. M., Balgoma, D., Nicholas, B., Brandsma, J., Skipp, P. J., Snowden, S., Burg, D., D'Amico, A., Horvath, I., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00078812 · Cited by 272
Self-citationSaidi, T., Zaim, O., Moufid, M., El Bari, N., Ionescu, R., & Bouchikhi, B. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.10.178 · Cited by 255
Clinical use of exhaled volatile organic compounds in pulmonary diseases: a systematic review
van de Kant, K. D., van der Sande, L. J., Jöbsis, Q., van Schayck, O. C., & Dompeling, E. (2012) · Respiratory Research · doi:10.1186/1465-9921-13-117 · Cited by 252
van der Schee, M. P., Paff, T., Brinkman, P., van Aalderen, W. M. C., Haarman, E. G., & Sterk, P. J. (2015) · Chest · doi:10.1378/chest.14-0781 · Cited by 203
Self-citationElectronic Nose Technology in Respiratory Diseases
Dragonieri, S., Pennazza, G., Carratu, P., & Resta, O. (2017) · Lung · doi:10.1007/s00408-017-9987-3 · Cited by 179
“using the same e-nose were able to discriminate COPD from asthma (accuracy 96%) and less well with healthy smoker controls (accuracy 66%) [16].”
BackgroundMethodInfluentialSchleich, F. N., Zanella, D., Stefanuto, P.-H., Bessonov, K., Smolinska, A., Dallinga, J. W., Henket, M., Paulus, V., Guissard, F., Graff, S., et al. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201811-2210oc · Cited by 164
Breathomics for the clinician: the use of volatile organic compounds in respiratory diseases
Ibrahim, W., Carr, L., Cordell, R., Wilde, M. J., Salman, D., Monks, P. S., Thomas, P., Brightling, C. E., Siddiqui, S., & Greening, N. J. (2021) · Thorax · doi:10.1136/thoraxjnl-2020-215667 · Cited by 115
The smell of lung disease: a review of the current status of electronic nose technology
van der Sar, I. G., Wijbenga, N., Nakshbandi, G., Aerts, J. G. J. V., Manintveld, O. C., Wijsenbeek, M. S., Hellemons, M. E., & Moor, C. C. (2021) · Respiratory Research · doi:10.1186/s12931-021-01835-4 · Cited by 87
“Hanson 2005 [104] n = 19 VAP (clinical pneumonia score, CPIS ≥ 6) n = 19 controls (CPIS < 6) Diagnostic accuracy Correlation CPIS -breathprint R2 = 0.81 Cyranose 320 PLS Hockstein 2005 [105] n = 15 VAP (pneumonia score ≥ 7) n = 29 HC (ventilated) Diagnostic accuracy Acc 66–70% Cyranose 320 KNN Humphreys 2011 [99] n =…”
BackgroundResultInfluentialPeel, A. M., Wilkinson, M., Sinha, A., Loke, Y. K., Fowler, S. J., & Wilson, A. M. (2020) · Respiratory Medicine · doi:10.1016/j.rmed.2020.105984 · Cited by 40
“Awano (17) Brinkman (32) Dragonieri 2007 (18) Dragonieri 2018 (30) Fens 2009 (19) Fens 2011 (31) Ibrahim (20) Larstad (21) Lazar (39) Meyer (22) Montuschi (23) Olopade 44 (24) Paredi (25) Plaza (33) Reynolds (35) van der Schee 2013 (27) van der Schee 2013 (26) Timms, Thomas & Yates (28) de…”
Influential
Metadata
- Authors
- Fens, N., Zwinderman, A. H., van der Schee, M. P., de Nijs, S. B., Dijkers, E., Roldaan, A. C., Cheung, D., Bel, E. H., & Sterk, P. J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-12-01
- Volume
- 180
- Issue
- 11
- Pages
- 1076-1082
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2007698831
- Cited by
- 364
- References
- 41
- FWCI
- 13.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.