CoChat

Impairment of the Transient Pupillary Light Reflex in Rpe65−/−Mice and Humans with Leber Congenital Amaurosis

Aleman, Tomas S., Jacobson, Samuel G., Chico, John D., Scott, Michele L., Cheung, Andy Y., Windsor, Elizabeth A. M., Furushima, Masatoshi, Redmond, T. Michael, Bennett, Jean, Palczewski, Krzysztof, Cideciyan, Artur V. · 2004 · Investigative Opthalmology & Visual Science
Cited by 101

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

PURPOSE: To determine the impairment of the transient pupillary light reflex (TPLR) due to severe retinal dysfunction and degeneration in a murine model of Leber congenital amaurosis (LCA) and in patients with the disease. METHODS: Direct TPLR was elicited in anesthetized, dark-adapted Rpe65(-/-) and control mice with full-field light stimuli (0.1 second duration) of increasing intensities (-6.6 to +2.3 log scot-cd. m(-2)). 9-cis-Retinal was administered orally to a subset of Rpe65(-/-) mice, and TPLR was recorded 48 hours after the treatment. TPLR was also measured in a group of patients with LCA. RESULTS: Baseline pupillary diameters in Rpe65(-/-) and control mice were similar. TPLR thresholds of Rpe65(-/-) mice were elevated by 5 log units compared with those of control animals. The waveform of the TPLR in Rpe65(-/-) mice was similar to that evoked by 4.8-log-unit dimmer stimuli in control mice. Treatment of Rpe65(-/-) mice with 9-cis-retinal lowered the TPLR threshold by 2.1 log units. Patients with LCA had baseline pupillary diameters similar to normal, but the TPLR was abnormal, with thresholds elevated by 3 to more than 6 log units. When adjusted to the elevation of TPLR threshold, pupillary constriction kinetics in most patients were similar to those in normal subjects. CONCLUSIONS: Pupillometry was used to quantify visual impairment and to probe transmission of retinal signals to higher nervous centers in a murine model of LCA and in patients with LCA. Mouse results were consistent with a dominant role of image-forming photoreceptors driving the early phase of the TPLR when elicited by short-duration stimuli. The objective and noninvasive nature of the TPLR measurement, and the observed post-treatment change toward normal in the animal model supports the notion that this may be a useful outcome measure in future therapeutic trials of LCA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.03-1230

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Aleman, T. S., Jacobson, S. G., Chico, J. D., Scott, M. L., Cheung, A. Y., Windsor, E. A. M., Furushima, M., Redmond, T. M., Bennett, J., Palczewski, K., & Cideciyan, A. V.
Venue
Investigative Opthalmology & Visual Science
Published
2004-04-01
Volume
45
Issue
4
Pages
1259
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2164088504
Cited by
101
References
7
FWCI
1.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.