Depth-Dependent Transverse Shear Properties of the Human Corneal Stroma
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
PURPOSE: To measure the transverse shear modulus of the human corneal stroma and its profile through the depth by mechanical testing, and to assess the validity of the hypothesis that the shear modulus will be greater in the anterior third due to increased interweaving of lamellae. METHODS: Torsional rheometry was used to measure the transverse shear properties of 6 mm diameter buttons of matched human cadaver cornea pairs. One cornea from each pair was cut into thirds through the thickness with a femtosecond laser and each stromal third was tested individually. The remaining intact corneas were tested to measure full stroma shear modulus. The shear modulus from a 1% shear strain oscillatory test was measured at various levels of axial compression for all samples. RESULTS: After controlling for axial compression, the transverse shear moduli of isolated anterior layers were significantly higher than central and posterior layers. Mean modulus values at 0% axial strain were 7.71 ± 6.34 kPa in the anterior, 1.99 ± 0.45 kPa in the center, 1.31 ± 1.01 kPa in the posterior, and 9.48 ± 2.92 kPa for full thickness samples. A mean equilibrium compressive modulus of 38.7 ± 8.6 kPa at 0% axial strain was calculated from axial compression measured during the shear tests. CONCLUSIONS: Transverse shear moduli are two to three orders of magnitude lower than tensile moduli reported in the literature. The profile of shear moduli through the depth displayed a significant increase from posterior to anterior. This gradient supports the hypothesis and corresponds to the gradient of interwoven lamellae seen in imaging of stromal cross-sections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reinstein, D. Z., Archer, T. J., Gobbe, M., Silverman, R. H., & Coleman, D. J. (2008) · Journal of Refractive Surgery · doi:10.3928/1081597x-20080601-05 · Cited by 379
Full-field deformation of bovine cornea under constrained inflation conditions
Boyce, B. L., Grazier, J. M., Jones, R. E., & Nguyen, T. D. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.011 · Cited by 191
Abahussin, M., Hayes, S., Knox Cartwright, N. E., Kamma-Lorger, C. S., Khan, Y., Marshall, J., & Meek, K. M. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3669 · Cited by 162
Evaluating Corneal Collagen Organization Using High-Resolution Nonlinear Optical Macroscopy
Jester, J. V., Winkler, M., Jester, B. E., Nien, C., Chai, D., & Brown, D. J. (2010) · Eye & Contact Lens: Science & Clinical Practice · doi:10.1097/icl.0b013e3181ee8992 · Cited by 64
Cited by
Corneal biomechanics – a review
Kling, S., & Hafezi, F. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12345 · Cited by 194
“15 Collagen organisation is disturbed in certain degrading pathologies such as keratoconus, 16 demonstrating their importance for maintaining corneal shape.”
Three-dimensional distribution of transverse collagen fibers in the anterior human corneal stroma
Winkler, M., Shoa, G., Xie, Y., Petsche, S. J., Pinsky, P. M., Juhasz, T., Brown, D. J., & Jester, J. V. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-13150 · Cited by 152
“Imaging has shown this axial heterogeneity for some time, and the corresponding characterization of corneal biomechanical properties has recently been undertaken.(19,20,33) To the best of our knowledge, the depth-dependent angular distribution of transverse collagen fibers has only been implemented in a single finite…”
BackgroundSelf-citationWhitford, C., Studer, H., Boote, C., Meek, K. M., & Elsheikh, A. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.11.006 · Cited by 94
Transverse depth-dependent changes in corneal collagen lamellar orientation and distribution
Abass, A., Hayes, S., White, N., Sorensen, T., & Meek, K. M. (2015) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0717 · Cited by 78
“It has been suggested that the structural organization of the anterior cornea, which confers heightened elastic [3,5] and transverse shear moduli [6,7] and rigidity in extreme hydration [8], likely also plays a role in the maintenance of corneal curvature.”
Background
Metadata
- Authors
- Petsche, S. J., Chernyak, D., Martiz, J., Levenston, M. E., & Pinsky, P. M.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2012-02-21
- Volume
- 53
- Issue
- 2
- Pages
- 873
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2080427807
- Cited by
- 141
- References
- 4
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.