The DOI matches its Crossref record; 204 of the 204 references it cites were found in a registry or an index.
Conventional and Quantitative Electroencephalography in Psychiatry
Abstract
Electrical activity of each brain region is homeostatically regulated, resulting in predictable frequency composition of the background EEG. Replicated normative databases have established that the EEG power spectrum is independent of ethnic background. Artifact-free EEG evaluated relative to such norms displays few deviant values in healthy, normally functioning individuals. In subjects with psychiatric disorders, high proportions of abnormal findings have been reported with good concordance and high specificity and sensitivity across numerous studies, distinctive within a wide variety of disorders and often contributing to differential diagnosis and selection of treatment. New three-dimensional QEEG imaging methods offer an economical alternative to other functional brain imaging modalities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring the Accuracy of Diagnostic Systems
Swets, J. A. (1988) · Science · doi:10.1126/science.3287615 · Cited by 10,058
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Llinás, R. R. (1988) · Science · doi:10.1126/science.3059497 · Cited by 2,285
3D statistical neuroanatomical models from 305 MRI volumes
Evans, A. C., Collins, D. L., Mills, S. R., Brown, E. D., Kelly, R. L., & Peters, T. M. (2005) · 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference · doi:10.1109/nssmic.1993.373602 · Cited by 1,487
Basic mechanisms of cerebral rhythmic activities
Steriade, M., Gloor, P., Llinás, R. R., Lopes da Silva, F. H., & Mesulam, M.-M. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90001-z · Cited by 1,137
McCormick, D. A. (1992) · Progress in Neurobiology · doi:10.1016/0301-0082(92)90012-4 · Cited by 1,117
Left frontal hypoactivation in depression.
Henriques, J. B., & Davidson, R. J. (1991) · Journal of Abnormal Psychology · doi:10.1037//0021-843x.100.4.535 · Cited by 920
Handbook of electroencephalography and clinical neurophysiology
Pfurtscheller, G. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90281-x · Cited by 711
Two bilateral sources of the late AEP as identified by a spatio-temporal dipole model
Scherg, M., & Von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90033-4 · Cited by 683
Henriques, J. B., & Davidson, R. J. (1990) · Journal of Abnormal Psychology · doi:10.1037//0021-843x.99.1.22 · Cited by 635
Cited by
Barry, R. J., Clarke, A. R., & Johnstone, S. J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00362-0 · Cited by 819
Millisecond by Millisecond, Year by Year: Normative EEG Microstates and Developmental Stages
Koenig, T., Prichep, L., Lehmann, D., Sosa, P. V., Braeker, E., Kleinlogel, H., Isenhart, R., & John, E. R. (2002) · NeuroImage · doi:10.1006/nimg.2002.1070 · Cited by 775
Self-citationBush, G., Valera, E. M., & Seidman, L. J. (2005) · Biological Psychiatry · doi:10.1016/j.biopsych.2005.01.034 · Cited by 714
Irani, F., Platek, S. M., Bunce, S., Ruocco, A. C., & Chute, D. (2007) · The Clinical Neuropsychologist · doi:10.1080/13854040600910018 · Cited by 451
Feature-level fusion approaches based on multimodal EEG data for depression recognition
Cai, H., Qu, Z., Li, Z., Zhang, Y., Hu, X., & Hu, B. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.01.008 · Cited by 347
A Meta-analysis of Quantitative EEG Power Associated With Attention-Deficit Hyperactivity Disorder
Snyder, S. M., & Hall, J. R. (2006) · Journal of Clinical Neurophysiology · doi:10.1097/01.wnp.0000221363.12503.78 · Cited by 344
EEG-defined subtypes of children with attention-deficit/hyperactivity disorder
Clarke, A. R., Barry, R. J., McCarthy, R., & Selikowitz, M. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00668-x · Cited by 330
What is Neurofeedback: An Update
Hammond, D. C. (2011) · Journal of Neurotherapy · doi:10.1080/10874208.2011.623090 · Cited by 307
Advances in Quantitative Electroencephalogram Analysis Methods
Thakor, N. V., & Tong, S. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121601 · Cited by 305
BOLD correlates of EEG alpha phase-locking and the fMRI default mode network
Jann, K., Dierks, T., Boesch, C., Kottlow, M., Strik, W., & Koenig, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.001 · Cited by 286
Prichep, L. S., John, E. R., Ferris, S. H., Rausch, L., Fang, Z., Cancro, R., Torossian, C., & Reisberg, B. (2006) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2005.07.021 · Cited by 278
Self-citationInvariant Reversible QEEG Effects of Anesthetics
John, E. R., Prichep, L. S., Kox, W., Valdés-Sosa, P., Bosch-Bayard, J., Aubert, E., Tom, M., diMichele, F., & Gugino, L. D. (2001) · Consciousness and Cognition · doi:10.1006/ccog.2001.0507 · Cited by 274
Self-citationGugino, L. D., Chabot, R. J., Prichep, L. S., John, E. R., Formanek, V., & Aglio, L. S. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.3.421 · Cited by 272
Self-citationA Comparison of the Electroencephalogram between Institutionalized and Community Children in Romania
Marshall, P. J., Fox, N. A., & Group, B. C. (2004) · Journal of Cognitive Neuroscience · doi:10.1162/0898929042304723 · Cited by 268
“A different mechanism proposed for an excess of relative lowfrequency activity in the adult EEG is that GABA release in the nucleus reticularis thalami slows the dominant EEG rhythm and diminishes the transmission of sensory stimuli through the thalamus to the cortex (Hughes & John, 1999).”
BackgroundThe neurophysics of consciousness
John, E. R. (2002) · Brain Research Reviews · doi:10.1016/s0165-0173(02)00142-x · Cited by 262
Self-citationSokhadze, T. M., Cannon, R. L., & Trudeau, D. L. (2008) · Applied Psychophysiology and Biofeedback · doi:10.1007/s10484-007-9047-5 · Cited by 222
“therapies) has been considered in an open case series reported by Kelly (1997). This three year follow-up study presented the treatment outcomes of 19 Dine’ (Navajo) clients.”
BackgroundA field theory of consciousness.
John, E. R. (2001) · Consciousness and Cognition · doi:10.1006/ccog.2001.0508 · Cited by 214
Self-citationMiskovic, V., Ma, X., Chou, C.-A., Fan, M., Owens, M., Sayama, H., & Gibb, B. E. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.013 · Cited by 175
Bayesian estimation of synaptic physiology from the spectral responses of neural masses
Moran, R. J., Stephan, K. E., Kiebel, S. J., Rombach, N., O'Connor, W. T., Murphy, K. J., Reilly, R. B., & Friston, K. J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.01.025 · Cited by 126
Micoulaud-Franchi, J.-A., McGonigal, A., Lopez, R., Daudet, C., Kotwas, I., & Bartolomei, F. (2015) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2015.10.077 · Cited by 111
Review of the therapeutic neurofeedback method using electroencephalography: EEG Neurofeedback
Omejc, N., Rojc, B., Battaglini, P. P., & Marusic, U. (2018) · Bosnian Journal of Basic Medical Sciences · doi:10.17305/bjbms.2018.3785 · Cited by 91
The role of quantitative electroencephalography in child and adolescent psychiatric disorders
Chabot, R. J., di Michele, F., & Prichep, L. (2005) · Child and Adolescent Psychiatric Clinics of North America · doi:10.1016/j.chc.2004.07.005 · Cited by 83
White, D., De Klerk, S., Woods, W., Gondalia, S., Noonan, C., & Scholey, A. (2016) · Nutrients · doi:10.3390/nu8010053 · Cited by 85
Perera, M. P. N., Bailey, N. W., Herring, S. E., & Fitzgerald, P. B. (2019) · Journal of Anxiety Disorders · doi:10.1016/j.janxdis.2018.11.001 · Cited by 67
Barbier, A. J., Hilhorst, M., Vliet, A. V., Snyder, P., Palfreyman, M. G., Gawryl, M., Dgetluck, N., Massaro, M., Tiessen, R., Timmerman, W., et al. (2015) · Clinical Therapeutics · doi:10.1016/j.clinthera.2014.09.013 · Cited by 51
Efficacy of EEG neurofeedback in psychiatry: A comprehensive overview and meta-analysis
J.H. Begemann, M., J.R. Florisse, E., van Lutterveld, R., Kooyman, M., & E. Sommer, I. (2016) · Translational Brain Rhythmicity · doi:10.15761/tbr.1000105 · Cited by 44
“A voluminous literature describes the robustness of EEG abnormalities found in a high proportion of psychiatric patients and the clinical implications [2], depending on the psychiatric disorder targeted.”
BackgroundEEG Biofeedback for Addictive Disorders—The State of the Art in 2004
Trudeau, D. L. (2005) · Journal of Adult Development · doi:10.1007/s10804-005-7030-z · Cited by 34
Dodecanogram (DDG): advancing EEG technology with a high-frequency brain activity measurement device
Singh, P. (2023) · Journal of Multiscale Neuroscience · doi:10.56280/1600841751 · Cited by 17
Metadata
- Authors
- Hughes, J. R., & John, E. R.
- Venue
- The Journal of Neuropsychiatry and Clinical Neurosciences
- Published
- 1999-05
- Volume
- 11
- Issue
- 2
- Pages
- 190-208
- ISSN
- 0895-0172 (ISSN-L)
- 1545-7222
- OpenAlex
- W2068503723
- Cited by
- 489
- References
- 204
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.