Methods for Estimation of Subsample Time Delays of Digitized Echo Signals
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Time delay estimation (TDE) is commonly performed in practice by crosscorrelation of digitized echo signals. Since time delays are generally not integral multiples of the sampling period, the location of the largest sample of the crosscorrelation function (ccf) is an inexact estimator of the location of the peak. Therefore, one must interpolate between the samples of the ccf to improve the estimation precision. Using theory and simulations, we review and compare the performance of several methods for interpolation of the ccf. The maximum likelihood approach to interpolation is the application of a reconstruction filter to the discrete ccf. However, this method can only be approximated in practice and can be computationally intensive. For these reasons, a simple method is widely used that involves fitting a parabola (or other curve) to samples of the ccf in the neighborhood of its peak. We describe and compare two curve-fitting methods: parabolic and cosine interpolation. Curve-fitting interpolation can yield biased time-delay estimates, which may preclude the use of these methods in some applications. The artifactual effect of these bias errors on elasticity imaging by elastography is discussed. We demonstrate that reconstructive interpolation is unbiased. An iterative implementation of the reconstruction procedure is proposed that can reduce the Computation time significantly.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The generalized correlation method for estimation of time delay
Knapp, C., & Carter, G. (1976) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1976.1162830 · Cited by 4,433
Detection, Estimation, and Modulation Theory, Part I
Van Trees, H. L. (2001) · John Wiley & Sons, Inc. eBooks · doi:10.1002/0471221082 · Cited by 3,891
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Self-citationCoherence and time delay estimation
Carter, G. C. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13723 · Cited by 1,200
A digital signal processing approach to interpolation
Schafer, R. W., & Rabiner, L. R. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.9150 · Cited by 554
Algorithms for ambiguity function processing
Stein, S. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163621 · Cited by 496
Flax, S. W., & O’Donnell, M. (1988) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.9333 · Cited by 483
(1993) · NDT & E International · doi:10.1016/0963-8695(93)90667-j · Cited by 395
An overview on the time delay estimate in active and passive systems for target localization
Quazi, A. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163618 · Cited by 393
Angle Independent Ultrasonic Detection of Blood Flow
Trahey, G. E., Allison, J. W., & von Ramm, O. T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325938 · Cited by 386
Research works printed but not linked: 3
- Bendat J.S., 1986, Random Data: Analysis and Measurement
- Céspedes I., Elastography: Imaging of Biological Tissue Elasticity, Ph.D. Dissertation (Dept. of Electrical Engineering, University of Houston, Texas, 1993).
- Trahey G.E., 1988, IEEE Trans. Biomed. Eng., 34, 965
Cited by
Items 101–200 of 431
Fundamental performance assessment of 2-D myocardial elastography in a phased-array configuration
Luo, J., Lee, W.-N., & Konofagou, E. E. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1313 · Cited by 35
de Korte, C. L., Schaar, J. A., Mastik, F., et al. (2003) · Journal of Interventional Cardiology · doi:10.1034/j.1600-0854.2003.8049.x · Cited by 34
Liu, Z., Huang, C., & Luo, J. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2705186 · Cited by 33
Local Elasticity Imaging of Vulnerable Atherosclerotic Coronary Plaques
Baldewsing, R. A., Schaar, J. A., Mastik, F., et al. (2006) · KARGER eBooks · doi:10.1159/000096719 · Cited by 33
Time-delay estimation in ultrasound echo signals using individual sample tracking
Zahiri-Azar, R., & Salcudean, S. E. (2008) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.979 · Cited by 33
Wang, C., Li, T., & Zheng, Y. (2014) · PLoS ONE · doi:10.1371/journal.pone.0101769 · Cited by 35
Noise Performance and Signal-to-Noise Ratio of Shear Strain Elastograms
Kumar, A. T., Ophir, J., & Krouskop, T. A. (2005) · Ultrasonic Imaging · doi:10.1177/016173460502700302 · Cited by 33
Self-citation3D normalized cross-correlation for estimation of the displacement field in ultrasound elastography
Mirzaei, M., Asif, A. A., Fortin, M., et al. (2019) · Ultrasonics · doi:10.1016/j.ultras.2019.106053 · Cited by 31
Stress evaluation by pulse-echo ultrasonic longitudinal wave
Vangi, D. (2001) · Experimental Mechanics · doi:10.1007/bf02323145 · Cited by 31
An Approach to Unbiased Subsample Interpolation for Motion Tracking
McCormick, M. M., & Varghese, T. (2013) · Ultrasonic Imaging · doi:10.1177/0161734613476176 · Cited by 32
“Cespedes et al.(1) examined the theoretical limits for time-delay estimation using cross-correlation with parameters from a typical ultrasound system.”
BackgroundMethodInfluentialClutter filtering influence on blood velocity estimation using speckle tracking
Fadnes, S., Bjærum, S., Torp, H. G., & Løvstakken, L. (2015) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2015.007247 · Cited by 32
“Parabolic subsample interpolation of the estimated grid displacement [20] was further used in the x and z directions, respectively, to improve the velocity resolution.”
MethodMartı́n, J. M., Jiménez, A. R., Seco, F. A., et al. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(02)00211-x · Cited by 31
“If needed, precision can be increased beyond the sampling time by using curvefitting or interpolation methods [8].”
BackgroundCombined AOA/TOA UWB localization
Galler, S. J., Gerok, W., Schroeder, J., et al. (2007) · International Symposium on Communications and Information Technologies · doi:10.1109/iscit.2007.4392171 · Cited by 31
Azar, R. Z., Baghani, A., Salcudean, S. E., & Rohling, R. N. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1709 · Cited by 30
“sub-sample accuracy was achieved using cosine fit [42].”
MethodComparison of shift estimation strategies in spectral elastography
Hoyt, K., Forsberg, F., & Ophir, J. (2005) · Ultrasonics · doi:10.1016/j.ultras.2005.08.006 · Cited by 30
“Though several methods have evolved over the years and have appeared in the literature [17,19], the focus of the comparison made in this paper will be on the parabolic and cosine curving fitting methods due to their relative computational simplicity.”
MethodResultInfluentialSelf-citationElastography: A Decade of Progress (2000-2010)
Ophir, J., Srinivasan, S., Righetti, R., & Thittai, A. K. (2011) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/157340511798038693 · Cited by 30
Self-citationHarper, S. E., Roembke, R. A., Zunker, J. D., Thelen, D. G., & Adamczyk, P. G. (2020) · Sensors · doi:10.3390/s20174805 · Cited by 33
“Cosine fitting of the cross-correlation permits subsample resolution in determining optimal signal delay, resulting in theoretical errors less than 1% of the time delay [45].”
BackgroundCompensation of Multiple Access Interference Effects in CDMA-Based Acoustic Positioning Systems
Seco, F. A., Prieto, J. C., Jiménez, A. R., et al. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2312511 · Cited by 28
Liu, F., Qiang, Y., Zhang, Q., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.10.007 · Cited by 28
Optimized Dynamic Acousto-elasticity Applied to Fatigue Damage and Stress Corrosion Cracking
Haupert, S., Rivière, J., Anderson, B. E., et al. (2014) · Journal of Nondestructive Evaluation · doi:10.1007/s10921-014-0231-2 · Cited by 28
Ebrahimi, A., Loegering, I. F., Martin, J. A., Pomeroy, R. L., Roth, J. D., & Thelen, D. G. (2020) · Experimental Gerontology · doi:10.1016/j.exger.2020.110966 · Cited by 29
Kim, S., Aglyamov, S. R., Park, S., et al. (2011) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1876 · Cited by 27
Phase-Sensitive 2D Motion Estimators Using Frequency Spectra of Ultrasonic Echoes
Hasegawa, H. (2016) · Applied Sciences · doi:10.3390/app6070195 · Cited by 27
SWAVE Imaging of Placental Elasticity and Viscosity: Proof of Concept
Abeysekera, J. M., Ma, M., Pesteie, M., Terry, J., Pugash, D., Hutcheon, J. A., Mayer, C., Lampe, L., Salcudean, S. E., & Rohling, R. N. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.01.014 · Cited by 27
GPU Accelerated Multilevel Lagrangian Carotid Strain Imaging
Meshram, N. H., & Varghese, T. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2841346 · Cited by 30
Calibration of the shear wave speed-stress relationship in ex vivo tendons
Martin, J. A., Schmitz, D. G., Ehlers, A. C., Allen, M. S., & Thelen, D. G. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.04.015 · Cited by 25
“Cosine interpolation was used to compute sub-pixel displacements (Céspedes et al., 1995).”
MethodLocally optimized correlation-guided Bayesian adaptive regularization for ultrasound strain imaging
Mukaddim, R. A., Meshram, N. H., & Varghese, T. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab735f · Cited by 27
“D windowed Sinc interpolation (Céspedes et al., 1995; McCormick and Varghese, 2013; Meshram and Varghese, 2018) for unbiased subsample displacement estimation.”
BackgroundAccurate Estimation of Carotid Luminal Surface Roughness Using Ultrasonic Radio-Frequency Echo
Kitamura, K., Hasegawa, H., & Kanai, H. (2012) · Japanese Journal of Applied Physics · doi:10.1143/jjap.51.07gf08 · Cited by 26
Diurnal and Semidiurnal P‐ and S‐Wave Velocity Changes Measured Using an Airgun Source
Wang, B., Yang, W., Wang, W., et al. (2019) · Journal of Geophysical Research Solid Earth · doi:10.1029/2019jb018218 · Cited by 26
“Both methods perform equally well (e.g., Céspedes et al., 1995).”
MethodThe fundamental mechanisms of the Korotkoff sounds generation
Baranger, J., Villemain, O., Goudot, G., Dizeux, A., Blay, H. L., Mirault, T., Messas, E., Pernot, M., & Tanter, M. (2023) · Science Advances · doi:10.1126/sciadv.adi4252 · Cited by 30
Ram, F., Zaefferer, S., & Raabe, D. (2014) · Journal of Applied Crystallography · doi:10.1107/s1600576713030446 · Cited by 26
Pan, X., Liu, K., Shao, J., et al. (2015) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2015.007245 · Cited by 25
Multiperspective Bistatic Ultrasound Imaging and Elastography of the Ex Vivo Abdominal Aorta
van Hal, V. H. J., de Hoop, H., Muller, J.-W., et al. (2021) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2021.3128227 · Cited by 25
Non-contact and through-clothing measurement of the heart rate using ultrasound vibrocardiography
Jeger‐Madiot, N., Gâteau, J., Fink, M., & Ing, R.-K. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.09.003 · Cited by 25
Scaling analysis of downstream heating and flow dynamics of fires over an inclined surface
Ren, X., Sluder, E. T., Heck, M. V., Grumstrup, T. P., Finney, M. A., Mäkiharju, S. A., & Gollner, M. J. (2022) · Combustion and Flame · doi:10.1016/j.combustflame.2022.112203 · Cited by 23
Analytical phase-tracking-based strain estimation for ultrasound elasticity
Yuan, L., & Pedersen, P. C. (2015) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.006701 · Cited by 27
“It has been demonstrated that unbiased reconstructive interpolation can provide subsample accuracy, however with a heavy computation load [17].”
BackgroundViola, F., Coe, R. L., Owen, K., Guenther, D. A., & Walker, W. F. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9564-2 · Cited by 24
Takahashi, H., Hasegawa, H., & Kanai, H. (2015) · Journal of Medical Ultrasonics · doi:10.1007/s10396-015-0620-x · Cited by 23
“Then, the averaged 2D-CF is up-sampled with a reconstructive interpolation to follow a small displacement between consecutive frames below the sampling interval [21].”
MethodShear wave arrival time estimates correlate with local speckle pattern
McAleavey, S. A., Osapoetra, L. O., & Langdon, J. (2015) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2015.007171 · Cited by 23
Swillens, A., Segers, P., & Løvstakken, L. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.06.021 · Cited by 23
“Since the velocity resolution in speckle tracking is at first determined by the image grid (see further), we interpolated the SAD matrix (parabolic fitting, (Cespedes et al, 1995)) to improve the accuracy.”
MethodMaleke, C., Luo, J., Gamarnik, V., et al. (2010) · Ultrasonic Imaging · doi:10.1177/016173461003200304 · Cited by 23
Estimating the elastographic signal-to-noise ratio using correlation coefficients
Srinivasan, S. S., Kallel, F., & Ophir, J. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00510-5 · Cited by 23
Self-citationReal time strain imaging and in-vivo applications in prostate cancer
Pesavento, A., & Lorenz, A. (2002) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2001.992038 · Cited by 23
“Furthermore, the postcompression signal has to be time-shifted by a sub-sample time shift [3].”
BackgroundJiang, J., & Strother, C. M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2216542 · Cited by 22
Nagaoka, R., Mozumi, M., & Hasegawa, H. (2019) · Japanese Journal of Applied Physics · doi:10.7567/1347-4065/ab0ffa · Cited by 22
Blank, J. L., Thelen, D. G., Allen, M. S., & Roth, J. D. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104964 · Cited by 21
3-D phantom and in vivo cardiac speckle tracking using a matrix array and raw echo data
Byram, B. C., Holley, G., Giannantonio, D. M., et al. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1489 · Cited by 22
The effects of digitization on the elastographic signal-to-noise ratio
Srinivasan, S. S., Kallel, F., & Ophir, J. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00652-x · Cited by 22
Self-citationSelladurai, S., & Thittai, A. K. (2018) · Ultrasonics · doi:10.1016/j.ultras.2018.10.007 · Cited by 21
Mukaddim, R. A., Meshram, N. H., Mitchell, C., et al. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2928546 · Cited by 21
Wavelet-based and data-adaptive methods for time delay estimation in acoustic leak detection
Uchendu, N., Muggleton, J. M., & White, P. R. (2024) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2024.111727 · Cited by 23
Elastography Using Harmonic Ultrasonic Imaging: A Feasibility Study
Desai, R. R., Krouskop, T. A., & Righetti, R. (2010) · Ultrasonic Imaging · doi:10.1177/016173461003200204 · Cited by 20
Liu, Z., Lin, B., Liang, X., & Du, A. (2021) · Measurement · doi:10.1016/j.measurement.2021.109965 · Cited by 22
Ahmadi, N., Ruiz-García, J., Hajsadeghi, F., Azen, S. P., Mack, W. J., Hodis, H. N., & Lerman, A. (2014) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12220 · Cited by 21
In vivo elastographic investigation of ethanol-induced hepatic lesions
Hoyt, K., Forsberg, F., Merritt, C. R. B., et al. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.01.017 · Cited by 20
Self-citationA Kalman-based Doppler tracking algorithm for underwater acoustic spread spectrum communications
Sun, D., Hong, X., & Cui, H. (2021) · Applied Acoustics · doi:10.1016/j.apacoust.2021.108374 · Cited by 19
Albinsson, J., Brorsson, S., Ahlgren, Å. R., & Cinthio, M. (2014) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.05.010 · Cited by 19
Hansen, H. H. G., Richards, M. S., Doyley, M. M., & de Korte, C. L. (2013) · Sensors · doi:10.3390/s130303341 · Cited by 20
Chung, C.-Y., Heebner, J., Baskaran, H., Welter, J. F., & Mansour, J. M. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1356-x · Cited by 20
Echo motion imaging with adaptive clutter filter for assessment of cardiac blood flow
Takahashi, H., Hasegawa, H., & Kanai, H. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.07hf09 · Cited by 19
Cardiac biplane strain imaging: initialin vivoexperience
Lopata, R. G. P., Nillesen, M. M., Verrijp, C., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/4/004 · Cited by 19
“It was shown that this method performed equally well or even better than other interpolation techniques and also proved to be a fast alternative to interpolation of RF lines (Céspedes et al 1995, Lopata et al 2009b).”
MethodNagaoka, R., Ishikawa, K., Mozumi, M., Cinthio, M., & Hasegawa, H. (2020) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ab87f2 · Cited by 18
Li, F., He, Q., Huang, C., Liu, K., Shao, J., & Luo, J. (2016) · Ultrasonics · doi:10.1016/j.ultras.2015.12.015 · Cited by 19
Shaswary, E., Xu, Y., & Tavakkoli, J. (2016) · Ultrasonics · doi:10.1016/j.ultras.2016.03.002 · Cited by 20
Srinivasan, S. S., Ophir, J., & Alam, S. K. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.07.013 · Cited by 18
Self-citationSPIN: Synchronization Signal-Based Positioning Algorithm for IoT Nonterrestrial Networks
Rajendran, V., Chen, J., Lampe, L., Vos, G., & Dost, S. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3283989 · Cited by 19
A hybrid CPU-GPGPU approach for real-time elastography
Yang, X., Deka, S., & Righetti, R. (2011) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.2126 · Cited by 17
“Time-delay estimation (TDE) techniques are applied to the windowed signals to obtain a local displacement estimate [30].”
MethodRotation Elastogram Estimation Using Synthetic Transmit-aperture Technique: A Feasibility Study
Basavarajappa, L., Chintada, B. R., & Thittai, A. K. (2017) · Ultrasonic Imaging · doi:10.1177/0161734616686746 · Cited by 17
Aguilera, T., Seco, F. A., Álvarez, F. J., & Jiménez, A. R. (2017) · Measurement · doi:10.1016/j.measurement.2017.11.046 · Cited by 19
NUMERICAL STUDY OF PORE STRUCTURE EFFECTS ON ACOUSTIC LOGGING DATA IN THE BOREHOLE ENVIRONMENT
Li, T., Wang, Z., Yu, N., et al. (2020) · Fractals · doi:10.1142/s0218348x20500498 · Cited by 17
Plethysmographic arterial waveform strain discrimination by Fisher's method
Kucewicz, J. C., Huang, L., & Beach, K. W. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.04.002 · Cited by 17
Analysis of a hybrid spectral strain estimation technique in elastography
Hoyt, K., Forsberg, F., & Ophir, J. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/2/001 · Cited by 17
“Since these displacements are derived from a discrete valued correlation function, subsample estimation is typically employed in order to improve accuracy (Céspedes et al 1995).”
MethodSelf-citationCovariance analysis of time delay estimates for strained signals
Bilgen, M., & Insana, M. F. (1998) · IEEE Transactions on Signal Processing · doi:10.1109/78.720362 · Cited by 17
“In practice, interpolation routines normally used to locate the cross-correlation peak in sampled data can introduce additional bias [ 18 ].”
Reiter, A. J., Martin, J. A., Knurr, K. A., Adamczyk, P. G., & Thelen, D. G. (2024) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003396 · Cited by 16
Deng, L., Zhang, Y., Chen, Z., Zhao, Z., Zhang, K., & Wu, J. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2951922 · Cited by 16
Harper, S. E., Schmitz, D. G., Adamczyk, P. G., & Thelen, D. G. (2022) · Sensors · doi:10.3390/s22041589 · Cited by 16
“Additional uncertainty appears in computing wave speeds, though cosine fitting of the cross-correlation permits subsample resolution in determining optimal signal delay; this procedure results in theoretical errors less than 1% of the sample period [22,79].”
BackgroundEmerging Ultrasound Technologies for Early Markers of Disease
Feleppa, E. J., Alam, S. K., & Deng, C. X. (2002) · Disease Markers · doi:10.1155/2002/167104 · Cited by 16
Galler, S. J., Schroeder, J., Rahmatollahi, G., et al. (2006) · IEEE/ION Position Location and Navigation Symposium · doi:10.1109/plans.2006.1650604 · Cited by 16
Asari, D., Hasegawa, H., & Kanai, H. (2014) · Japanese Journal of Applied Physics · doi:10.7567/jjap.53.07kf21 · Cited by 15
Nagai, Y., Hasegawa, H., & Kanai, H. (2014) · Japanese Journal of Applied Physics · doi:10.7567/jjap.53.07kf19 · Cited by 15
Direct Digital Surface Model Generation by Semi-Global Vertical Line Locus Matching
Zhang, Y., Zhang, Y., Mo, D., Zhang, Y., & Li, X. (2017) · Remote Sensing · doi:10.3390/rs9030214 · Cited by 15
Shear wave speeds track axial stress in porcine collateral ligaments
Blank, J. L., Thelen, D. G., & Roth, J. D. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103704 · Cited by 15
Characterization of blood mimicking fluid with ultrafast ultrasonic and optical image velocimeters
Omura, M., Nagaoka, R., Yagi, K., Yoshida, K., Yamaguchi, T., & Hasegawa, H. (2022) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ac4ea9 · Cited by 15
Joint deconvolution of building and downhole seismic recordings: an application to three test cases
Petrović, B., Parolai, S., Pianese, G., et al. (2017) · Bulletin of Earthquake Engineering · doi:10.1007/s10518-017-0215-6 · Cited by 15
“…is resampled by interpolation (originally 100 samples per second) in order to obtain the same sampling rate as the data from the downhole sensors (500 samples per second) to improve the resolution of the deconvolution results in the time domain (e.g., Céspedes et al. 1995; Tamim and Ghani 2010).”
BackgroundMethodSavio, F. L., & Bonfanti, M. (2019) · Polymer Testing · doi:10.1016/j.polymertesting.2019.01.005 · Cited by 15
Refining Time Delay Estimate of Complex Signal Using Polynomial Interpolation in Time Domain
Guschina, O. (2021) · Systems of Signals Generating and Processing in the Field of on Board Communications · doi:10.1109/ieeeconf51389.2021.9416076 · Cited by 14
Nguyen, T.-T., Cheng, C.-H., Liu, D., & Le, M.-H. (2021) · Electronics · doi:10.3390/electronics11010045 · Cited by 16
A Kalman Filter Approach for Estimating Tendon Wave Speed from Skin-Mounted Accelerometers
Schmitz, D. G., Thelen, D. G., & Cone, S. G. (2022) · Sensors · doi:10.3390/s22062283 · Cited by 14
Comparison of ultrasonic motion estimators for vascular applications
Miyajo, A., Nagaoka, R., & Hasegawa, H. (2019) · Japanese Journal of Applied Physics · doi:10.7567/1347-4065/ab19b5 · Cited by 14
Martin, J. A., Kindig, M. W., Stender, C. J., et al. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109799 · Cited by 14
“Cosine interpolation was used to estimate the timing of peak cross-correlation with sub-frame accuracy (Céspedes et al., 1995).”
MethodEbrahimi, A., Martin, J. A., Schmitz, D. G., & Thelen, D. G. (2020) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2020.00069 · Cited by 15
Methods based on wavelets for time delay estimation of ultrasound signals
Guetbi, C., Kouamé, D., Ouahabi, A., & Chemla, J.-P. (2002) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs.1998.813947 · Cited by 17
Normal and shear strain imaging using 2D deformation tracking on beam steered linear array datasets
Xu, H., & Varghese, T. (2012) · Medical Physics · doi:10.1118/1.4770272 · Cited by 14
Angular strain estimation method for elastography
Bae, U., & Kim, Y. (2007) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.594 · Cited by 14
“We used the reconstructive interpolation and the cosine interpolation [ 15 ] to estimate displacements with subsample accuracy.”
BackgroundMethodInfluentialSato, M., Hasegawa, H., & Kanai, H. (2014) · Japanese Journal of Applied Physics · doi:10.7567/jjap.53.07kf03 · Cited by 20
The effect of nonlinear signal transformations on bias errors in elastography
Alam, S. K., & Jonathan Ophir, A. (2000) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.818774 · Cited by 14
Self-citationVariance and Covariance of Accumulated Displacement Estimates
Bayer, M., & Hall, T. J. (2013) · Ultrasonic Imaging · doi:10.1177/0161734613479246 · Cited by 13
“To reduce its influence, these simulations used the high sampling frequency of 100 samples per wavelength, with an additional subsample estimation using quadratic fitting around the matching function peak.(23) The normal sampling rate for a commercial ultrasound system, in contrast, might be 40 MHz, which for a signal…”
MethodNon-Destructive Evaluation of Green Ceramic Body Density by Ultrasonic Technique
Kulokas, M., Kazys, R. J., & Mažeika, L. (2011) · Elektronika ir Elektrotechnika · doi:10.5755/j01.eee.111.5.360 · Cited by 13
Svilainis, L., Lukoševičiūtė, K., & Liaukonis, D. (2017) · Ultrasonics · doi:10.1016/j.ultras.2017.01.003 · Cited by 13
“In the ideal case a sinc function should be used, but truncated interpolation function is computationally more efficient [9,13,14,41,42].”
BackgroundMethodInfluentialPianese, G., Petrović, B., Parolai, S., et al. (2018) · Bulletin of Earthquake Engineering · doi:10.1007/s10518-018-0307-y · Cited by 13
“…to avoid the trade-off between time accuracy and frequency accuracy, the resolution of the IIRFs and thus, the accuracy of estimating the time lags can be improved by resampling the recordings before applying the deconvolution interferometry (e.g., Céspedes et al. 1995; Tamim and Ghani 2010).”
Method
Metadata
- Authors
- Céspedes, I., Huang, Y., Ophir, J., & Spratt, S.
- Affiliations
- The University of Texas Medical School Radiology Department - Ultrasonics Laboratory Houston, TX 77030
- Diasonics Ultrasound Inc. San Jose, CA
- ORCID
- Céspedes, I.
- Venue
- Ultrasonic Imaging
- Publisher
- SAGE Publications
- Published
- 1995-04
- Volume
- 17
- Issue
- 2
- Pages
- 142-171
- ISSN
- 0161-7346 (ISSN-L)
- 1096-0910
- OpenAlex
- W2044310882
- Cited by
- 436
- References
- 28
- Citations by year
- 2026: 10 · 2025: 15 · 2024: 11 · 2023: 21 · 2022: 16 · 2021: 17 · 2020: 19 · 2019: 25 · 2018: 22 · 2017: 18 · 2016: 10 · 2015: 20 · 2014: 21 · 2013: 17 · 2012: 16
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Ultrasonic Imaging (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca038515-07, 5r01ca060520-03)
- National Cancer Institute (R01-CA60520, P01-CA64579, R01-CA-38515)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Physical Sciences › Earth and Planetary Sciences › Oceanography › Underwater Acoustics Research
- Keywords
- time delay estimation, echo signal, cross correlation function, interpolation, parabolic interpolation, curve fitting, reconstruction filter, maximum likelihood estimation, bias, elastography, iterative reconstruction
- MeSH terms
- Computer Simulation, Humans, Image Processing, Computer-Assisted, Signal Processing, Computer-Assisted, Time Factors, Ultrasonography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.