Methods for Estimation of Subsample Time Delays of Digitized Echo Signals
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Time delay estimation (TDE) is commonly performed in practice by crosscorrelation of digitized echo signals. Since time delays are generally not integral multiples of the sampling period, the location of the largest sample of the crosscorrelation function (ccf) is an inexact estimator of the location of the peak. Therefore, one must interpolate between the samples of the ccf to improve the estimation precision. Using theory and simulations, we review and compare the performance of several methods for interpolation of the ccf. The maximum likelihood approach to interpolation is the application of a reconstruction filter to the discrete ccf. However, this method can only be approximated in practice and can be computationally intensive. For these reasons, a simple method is widely used that involves fitting a parabola (or other curve) to samples of the ccf in the neighborhood of its peak. We describe and compare two curve-fitting methods: parabolic and cosine interpolation. Curve-fitting interpolation can yield biased time-delay estimates, which may preclude the use of these methods in some applications. The artifactual effect of these bias errors on elasticity imaging by elastography is discussed. We demonstrate that reconstructive interpolation is unbiased. An iterative implementation of the reconstruction procedure is proposed that can reduce the Computation time significantly.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The generalized correlation method for estimation of time delay
Knapp, C., & Carter, G. (1976) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1976.1162830 · Cited by 4,433
Detection, Estimation, and Modulation Theory, Part I
Van Trees, H. L. (2001) · John Wiley & Sons, Inc. eBooks · doi:10.1002/0471221082 · Cited by 3,891
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Self-citationCoherence and time delay estimation
Carter, G. C. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13723 · Cited by 1,200
A digital signal processing approach to interpolation
Schafer, R. W., & Rabiner, L. R. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.9150 · Cited by 554
Algorithms for ambiguity function processing
Stein, S. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163621 · Cited by 496
Flax, S. W., & O’Donnell, M. (1988) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.9333 · Cited by 483
(1993) · NDT & E International · doi:10.1016/0963-8695(93)90667-j · Cited by 395
An overview on the time delay estimate in active and passive systems for target localization
Quazi, A. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163618 · Cited by 393
Angle Independent Ultrasonic Detection of Blood Flow
Trahey, G. E., Allison, J. W., & von Ramm, O. T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325938 · Cited by 386
Research works printed but not linked: 3
- Bendat J.S., 1986, Random Data: Analysis and Measurement
- Céspedes I., Elastography: Imaging of Biological Tissue Elasticity, Ph.D. Dissertation (Dept. of Electrical Engineering, University of Houston, Texas, 1993).
- Trahey G.E., 1988, IEEE Trans. Biomed. Eng., 34, 965
Cited by
Items 301–400 of 431
Chakraborty, B., Liu, Z., Heyde, B., et al. (2016) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2016.7728621 · Cited by 3
“The sub-sample axial and lateral displacements were obtained by applying cosine interpolation around the peak of the NCC [10].”
MethodInfluentialDynamic Acousto-Elastic Testing
Haupert, S., Renaud, G., Rivière, J., et al. (2018) · Springer eBooks · doi:10.1007/978-3-319-94476-0_13 · Cited by 3
Wang, K., Zhang, Y., & Li, Z. (2022) · Optik · doi:10.1016/j.ijleo.2022.169929 · Cited by 3
Mori, S., Arakawa, M., & Kanai, H. (2023) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2022.11.014 · Cited by 3
Martin, J. A., & Thelen, D. G. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111699 · Cited by 3
Lee, C.-T., Chang, C.-H., & Lin, F.-Y. (2025) · Optics Express · doi:10.1364/oe.546754 · Cited by 5
Accuracy of localization of prostate lesions using manual palpation and ultrasound elastography
Kut, C., Schneider, C., Carter‐Monroe, N., et al. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.811683 · Cited by 3
Elderly depression diagnostic of diabetic patients by brain tissue pulsatility imaging
Hachemi, M. E., Réméniéras, J.-P., Desmidt, T., Camus, V., & Tranquart, F. (2010) · Physics Procedia · doi:10.1016/j.phpro.2010.01.090 · Cited by 3
“[18] I.”
Development of novel imaging probe for optical/acoustic radiation imaging (OARI)
Ejofodomi, O. A., Zderic, V., & Zara, J. M. (2013) · Medical Physics · doi:10.1118/1.4824149 · Cited by 3
Ternifi, R., Cazals, X., Desmidt, T., Camus, V., Cottier, J., Patat, F., & Réméniéras, J.-P. (2012) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2012.0236 · Cited by 3
Statistical Analysis of Strain Images Estimated from Overlapped and Filtered Echo Signals
Bilgen, M., Insana, M. F., Hall, T. J., et al. (1997) · Ultrasonic Imaging · doi:10.1177/016173469701900304 · Cited by 3
Cheng, X., Niu, F., Silver, P. G., et al. (2011) · Bulletin of the Seismological Society of America · doi:10.1785/0120100261 · Cited by 3
“We further used a cosine fitting method to estimate the subsample delay times that were not included from the cross-correlation method (De Jong et al., 1990; Cespedes et al., 1995).”
MethodImproved elevational and azimuthal motion tracking using sector scans
Owen, K., Mauldin, F. W., Nguyen, S. C., Tiouririne, M., & Hossack, J. A. (2013) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2616 · Cited by 3
“For subsample estimation, raised-cosine fitting was used because it is among the better computationally-efficient interpolation schemes [27].”
MethodLai, X., & Torp, H. (2002) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1996.584208 · Cited by 3
Subtraction elastography for the evaluation of ablation-induced lesions: a feasibility study
Shao, J., Wang, J., Zhang, Y., et al. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1004 · Cited by 3
Azar, R. Z., Baghani, A., Salcudean, S. E., et al. (2010) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2010.5935746 · Cited by 3
“Following the data acquisition, time series of motion for all the scan lines are estimated using the normalized crosscorrelation (1 mm window length and 50% window overlap) with three point cosine fit for sub-sampling [ 8 ].”
MethodAccurate Estimation of Carotid Luminal Surface Roughness Using Ultrasonic Radio-Frequency Echo
Kitamura, K., Hasegawa, H., & Kanai, H. (2012) · Japanese Journal of Applied Physics · doi:10.7567/jjap.51.07gf08 · Cited by 3
Takahashi, H., Hasegawa, H., & Kanai, H. (2017) · Choonpa Igaku · doi:10.3179/jjmu.jjmu.k.12 · Cited by 3
Zhao, L., & Vantsevich, V. V. (2019) · Vehicle System Dynamics · doi:10.1080/00423114.2019.1627468 · Cited by 3
Deformation imaging by ultrasound for the assessment of regional myocardial function
D’hooge, J., Claus, P., Bijnens, B. H., et al. (2004) · IEEE Symposium on Ultrasonics · doi:10.1109/ultsym.2003.1293345 · Cited by 3
Spectral strain estimation techniques for tissue elasticity imaging
Hoyt, K., & Forsberg, F. (2005) · doi:10.17918/etd-504 · Cited by 3
van der Steen, A. F. W., Schaar, J. A., Mastik, F., et al. (2003) · Ultrasound · doi:10.1177/1742271x0301100203 · Cited by 3
Continuous Time-Delay Estimation From Sampled Measurements
Abdalmoaty, M., & Medvedev, A. V. (2023) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2023.10.534 · Cited by 2
Gu, O., He, B., Xiong, L., et al. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-03008-5 · Cited by 2
“…including original samples in the NCCF, is input into a low-pass filter with a sinc-shaped impulse response to obtain the interpolated samples [33]: where x ( k ) is the NCCF; u and p are the origin and size of the peak-centered region, respectively; and k and t are the times corresponding to…”
Omura, M., Yagi, K., Nagaoka, R., Yoshida, K., Yamaguchi, T., & Hasegawa, H. (2025) · Ultrasonics · doi:10.1016/j.ultras.2025.107589 · Cited by 2
Shear Wave Propagation as a Noninvasive Metric of Loading and Microdamage in Tendon Fascicles
Kotha, S. R., Blank, J. L., Kahr, S. M., Reiter, A. J., Candan, S. Ş., Franck, C., & Thelen, D. G. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.107081 · Cited by 2
Assessment of Ultrasound Velocity Application for Chemical Process Monitoring
Svilainis, L., Rodríguez, A., Liaukonis, D., et al. (2015) · Elektronika ir Elektrotechnika · doi:10.5755/j01.eee.21.4.12783 · Cited by 2
Ultrasonic Technique for Experimental Evaluation of Structural Integrity
Vangi, D. (2001) · Journal of Testing and Evaluation · doi:10.1520/jte12259j · Cited by 2
Hoyt, K. (2011) · The International Journal of Multiphysics · doi:10.1260/1750-9548.5.1.9 · Cited by 2
Detection method for ranging performance of IR laser rangefinder based on aerosol echo simulation
Liu, M., Zhang, G., An, Z., et al. (2015) · Optik · doi:10.1016/j.ijleo.2015.09.182 · Cited by 2
Time delay estimation based on bandpass sampling theorem and bisection searching
Hu, D., Huang, Z. W., Lü, J., & Liang, K. (2015) · International Conference on Fuzzy Systems and Knowledge Discovery (FSKD) · doi:10.1109/fskd.2015.7382256 · Cited by 2
“In addition, these estimators are biased, as shown in [10], [14], because the interpolation process is implemented on statistical function, but not original signal itself.”
BackgroundMethodPerformance comparison of optical flow and block matching methods in shearing and rotating models
Liu, Z., & Luo, J. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2253689 · Cited by 2
“The degree of matching between the reference window and comparison window can be measured by using different criteria, including sum of absolute difference (SAD), sum of squared difference (SSD), normalized cross-correlation (NCC).”
MethodInfluentialContinuous Measurement of Stress‐Induced Travel‐Time Variations at SAFOD
Yang, C., Niu, F., Daley, T. M., et al. (2018) · Seismological Research Letters · doi:10.1785/0220180080 · Cited by 2
Determination of Propagation Times of Finite Ultrasonic Signals in the UFM Measuring Path
Gerasimov, S. I., Glushnev, V. D., & Zhelbakov, I. N. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2096/1/012189 · Cited by 2
Gerasimov, S. I., & Glushnev, V. D. (2022) · International Symposium INFOTEH-JAHORINA (INFOTEH) · doi:10.1109/infoteh53737.2022.9751299 · Cited by 2
Shear wave tensiometry tracks reductions in collateral ligament tension due to incremental releases
Blomquist, M. B., Blank, J. L., Schmitz, D. G., et al. (2022) · Journal of Orthopaedic Research® · doi:10.1002/jor.25400 · Cited by 2
Awad, S. I., Al-Abed, M. A., & Saraira, A. A. A. (2019) · IEEE Jordan International Joint Conference on Electrical Engineering and Information Technology (JEEIT) · doi:10.1109/jeeit.2019.8717446 · Cited by 2
“Methods that can be used for TDE include normalized cross-correlation (XCORR) methods, the sum of absolute differences (SAD) methods, and the sum of squared differences (SSD) methods [5, 6, 7].”
MethodEstimating Regional Myocardial Contraction Using Miniature Transducers on the Epicardium
Nguyễn, T. T., Espinoza, A. W., Hyler, S., et al. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.07.416 · Cited by 2
Guschina, O., & Shevgunov, T. Y. (2020) · Journal of Radio Electronics · doi:10.30898/1684-1719.2020.12.19 · Cited by 2
Crossambiguity and wavelet processing in ultrasound elasticity imaging
Céspedes, E. I., de Korte, C. L., & van der Steen, A. F. W. (2002) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1996.584191 · Cited by 2
Natural Brain Tissue Pulsatility measurement: A pilot study in older depressed patients
Hachemi, M. E., Desmidt, T., Patat, F., Camus, V., Cottier, J., & Réméniéras, J.-P. (2009) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2009.5442037 · Cited by 2
“[ 18 ]. To improve the estimation resolution an overlapping rate of 80% between elementary regions is applied.”
BackgroundEstimation of the correlation amplitude of rf signals: application to microcirculation study
Gens, F., Réméniéras, J.-P., Patat, F., et al. (2002) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.1997.661805 · Cited by 2
Ślak, B. (2020) · Scholarship at UWindsor (University of Windsor) · Cited by 1
Nonparametric surface regression for strain estimation
Lindop, J., Treece, G., Gee, A., et al. (2008) · Cambridge University Engineering Department Publications Database · Cited by 2
GNSS Interference Localization for Vehicular Jammers using low-cost COTS Sensors
Kocher, S., Hansen, J., & Rügamer, A. (2024) · International Conference on Localization and GNSS · doi:10.1109/icl-gnss60721.2024.10578445 · Cited by 1
Nimoh, D., Acquah, I., & Wordui, E. (2025) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/add7e2 · Cited by 1
Gerasimov, S. I., & Glushnev, V. D. (2025) · International Russian Automation Conference (RusAutoCon) · doi:10.1109/rusautocon65989.2025.11177310 · Cited by 1
Alves, M. F. D. S., de Souza, J. C. E., Tiago, M. M., Higuti, R. T., Teixeira, M. A. G., Mehl, A., & Pinto, J. C. (2026) · Measurement · doi:10.1016/j.measurement.2026.121263 · Cited by 1
Hansen, H. H. G., Idzenga, T., & de Korte, C. L. (2012) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2012.0641 · Cited by 1
“To estimate the location of the cross-correlation peak at subsample and sub-line level a 2D parabolic function was fitted through the peak of the cross-correlation function [11;12].”
MethodPerformance Comparison of Algorithms for Estimating the Strain of Soft Tissue from Ultrasound
Li, X., Huang, L., Zhang, G., et al. (2005) · Instrumentation Science & Technology · doi:10.1080/10739140500311254 · Cited by 1
Blood Flow Velocity Measurement: CCF Based on I/Q signal
Wang, J., & Liu, D. C. (2010) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2010.5517241 · Cited by 1
Time-of-flight estimation using synchronized chaotic systems
Wallinger, C. F., & Brandner, M. (2011) · Joint International Workshop on Nonlinear Dynamics and Synchronization and International Symposium on Theoretical Electrical Engineering (INDS & ISTET) · doi:10.1109/inds.2011.6024791 · Cited by 1
Speckle tracking for 3D freehand ultrasound reconstruction
Afsham, N. (2014) · Open Collections · doi:10.14288/1.0167624 · Cited by 1
Costet, A. (2016) · doi:10.7916/d81g0mhb · Cited by 1
Costa‐Júnior, J. F. S., & Machado, J. C. (2017) · Research on Biomedical Engineering · doi:10.1590/2446-4740.01617 · Cited by 1
Meshram, N. H., Jackson, D. C., Mitchell, C., et al. (2020) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc44109.2020.9175911 · Cited by 1
Thermal strain imaging in vivo using interpolated IQ-images
Yin, C., Wang, G., Yang, K., Tu, J., Guo, X., & Zhang, D. (2020) · Ultrasonics · doi:10.1016/j.ultras.2020.106292 · Cited by 1
An Interpolation-Free and Fitting-Less Sub-sample Time-Delay Estimation Algorithm
Teixeira, C., Ruano, M. G., & Pereira, W. C. A. (2013) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-03005-0_73 · Cited by 2
Haji, Y., Mori, S., Arakawa, M., et al. (2022) · Journal of Medical Ultrasonics · doi:10.1007/s10396-022-01229-z · Cited by 1
“(5) was interpolated at the sampling interval by a factor M based on the reconstructed interpolation method [32] by convoluting the sinc function.”
MethodGerasimov, S. I., & Glushnev, V. D. (2023) · International Youth Conference on Radio Electronics, Electrical and Power Engineering (REEPE) · doi:10.1109/reepe57272.2023.10086806 · Cited by 1
Harvey, B. C., Lutchen, K. R., & Barbone, P. E. (2016) · Ultrasonics · doi:10.1016/j.ultras.2016.11.023 · Cited by 1
Singular value decomposition filtering in high-frame-rate cardiac vector flow imaging
Mozumi, M., Nagaoka, R., & Hasegawa, H. (2020) · Bulletin of Electrical Engineering and Informatics · doi:10.11591/eei.v9i1.1858 · Cited by 1
Introduction to quasi-static elastography
Barbone, P. E., Oberai, A. A., & Hall, T. J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-809661-1.00004-2 · Cited by 1
Ultrasonic mapping of endogenous motion in brain tissue
Makūnaitė, M., Jurkonis, R., Matijošaitis, V., & Rastenytė, D. (2019) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2019.8925971 · Cited by 1
“Because the estimated inter-frame motion had integer accuracy, parabolic interpolation [8] of the correlation peak was applied to achieve sub-sample resolution of the inter-frame motion estimates.”
MethodMyocardial Strain Measured by Epicardial Transducers—Comparison Between Velocity Estimators
Nguyễn, T. T., Espinoza, A. W., Hyler, S., et al. (2021) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2021.01.012 · Cited by 1
Gerasimov, S. I., Glushnev, V. D., & Zhelbakov, I. N. (2021) · International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM) · doi:10.1109/icieam51226.2021.9446462 · Cited by 1
3D Elastography Using Freehand Ultrasound
Lindop, J. E., Treece, G. M., Gee, A., et al. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-30136-3_157 · Cited by 1
“Commonly the analysis is made faster by applying peak interpolation techniques [1, 22 , 23] to estimate sub-sample displacements from values of the normalised crosscorrelation to either side.”
MethodCheng, X. (2009) · Rice Research Repository (Rice University) · Cited by 1
Estimation of the correlation amplitude of RF signals in small cutaneous vessels
Gens, F., Remeuieras, J.-P., Diridollou, S., et al. (2000) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.883535 · Cited by 1
“The analytical position of the peak then is obtained by the parabolic interpolation of these points [16].”
Multi-dimensional sub-sample motion estimation: Initial results
Zahiri-Azar, R., Göksel, O., & Salcudean, S. E. (2009) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2009.5441958 · Cited by 1
“Alternatively, with small computational overhead, a curve or polynomial can be fitted to the pattern matching function in order to estimate the sub-sample motion [ 9 ].”
BackgroundA Two Dimensional Speckle Tracking Method Based on Zero Phase Crossing in Ultrasound
Zheng, F. (2015) · University of Minnesota Digital Conservancy (University of Minnesota) · Cited by 1
Wideband cross correlation model method for blood velocity estimation
Štúriková, E., Hoeks, A. P. G., & Luesink, R. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1996.652014 · Cited by 1
Flow velocity estimation using ultrasound signals and wavelet transformation
Guetbi, C., Kouamé, D., Ouahabi, A., Chemla, J.-P., & Bensaada, L. (2002) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.1998.722850 · Cited by 2
MECHANICAL CONSTANTS CHARACTERIZATION OF THIN LAYERS BY LOW FREQUENCY ULTRASONICS
Mittal, R. K., Rus, G., Gallego, R., et al. (2007) · Cited by 1
Mobile robot localisation : error modelling, data synchronisation and vision techniques
Zaman, M. (2006) · University of Surrey Open Research repository · Cited by 1
Velocity resolution improvement for high temporal resolution ultrasonic transducer
Nguyen, T. T., Espinoza, A. W., Hyler, S., et al. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092533 · Cited by 1
“the estimate of the location of the peak in the cross-correlation function [6].”
BackgroundHigh Intensity Focused Ultrasound (HIFU) Thermal Lesion Detection Using Local Harmonic Imaging
Gandhi, N. (2023) · doi:10.32920/24192348 · Cited by 1
Biomechanical Modeling of Atherosclerotic Plaques for Risk Assessment
Akyildiz, A. C. (2013) · EUR Research Repository (Erasmus University Rotterdam) · Cited by 2
Strain Tensor Elastography: 2D and 3D Visualizations
Sosa-Cabrera, D., Krissian, K., González-Fernández, J., Gómez, L., Rovaris, E., Castaño-Moraga, C. A., & Ruiz‐Alzola, J. (2009) · Advances in pattern recognition · doi:10.1007/978-1-84882-299-3_18 · Cited by 2
Ultrasound and photoacoustic imaging for cancer detection and therapy guidance
Kim, S. (2011) · Texas ScholarWorks (Texas Digital Library)
Acute and chronic myocardial infarct differentiation using atrial kick induced strain (AKIS) imaging
Byram, B. C., Oliveri, L., Wolf, P. D., et al. (2013) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2013.0027
“with the peak position refined using parabolic subsample estimation [20].”
MethodHonjo, Y., Hasegawa, H., & Kanai, H. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2935445
2D and 3D Bayesian displacement estimation
Byram, B. C., Rotemberg, V. M., & Trahey, G. E. (2012) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2012.0636
“The peak position was refined using parabolic subsample estimation [10].”
MethodAlgorithms for Ultrasound Elasticity Imaging
Kwon, S. (2012) · Journal of the Korean Society for Nondestructive Testing · doi:10.7779/jksnt.2012.32.5.484
The Feasibility of Myocardial Infarct Visualization Using Atrial Kick Induced Strain (AKIS) Contrast
Byram, B. C., Kim, H., Assche, L. M. V., et al. (2014) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.12.022
Evaluation of shift estimation techniques for spectral-based elastography
Hoyt, K., Forsberg, F., & Ophir, J. (2006) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2005.1603211
“This approach is termed the Strain Filter (SF) [9] and can be regarded as a measure of estimator performance.”
MethodSelf-citationStrain Imaging and Vascular Elasticity
Jerome, J. T. J. (2002)
Fine Elasticity Imaging Utilizin RF-echo Phase Matching
Sumi, C. (1999)
Ultrasound Thyroid Elastography as a Pre-FNA Screening Tool: Algorithms and Clinical Evaluation
Si, L. (2012) · ResearchWorks at the University of Washington (University of Washington)
High Frame Rate Ultrasonic Imaging of Flowing Blood Cells for Assessment of Cardiovascular Dynamics
Takahashi, H. (2015) · Institutional Repositories DataBase (IRDB)
Thury, A. Á., García‐García, H. M., & Regar, E. S. (2011) · Advances in bioinformatics and biomedical engineering book series · doi:10.4018/978-1-61350-095-8.ch004
Epoxy cure monitoring using ultrasonic spread spectrum binary signals
Liaukonis, D., Aleksandrovas, A., & Svilainis, L. (2014) · IEEE Workshop on Advances in Information, Electronic and Electrical Engineering (AIEEE) · doi:10.1109/aieee.2014.7020332
“In case correlation-based ToF position estimation random errors are estimated using Cramer-Rao lower error bound [11]:”
MethodTwo-dimensional simulations of displacement accumulation incorporating shear strain
Bayer, M., & Hall, T. J. (2013) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2013.0092
Model Based Ultrasonic Measurement Technique for Evaluation of the Adhesive Properties
Liaukonis, D., Mažeika, L., Barauskas, R., et al. (2018) · Elektronika ir Elektrotechnika · doi:10.5755/j01.eie.24.5.21840
Cardiac Strain and Strain Rate Imaging
Heyde, B., Mirea, O., & D’hooge, J. (2018) · Wiley eBooks · doi:10.1002/9781119021520.ch11 · Cited by 2
Liu, M., Li, Z. W., Wen, G. Y., et al. (2018) · CRC Press eBooks · doi:10.1201/9780429447082-21
Time-of-Flight Estimation Using Synchronized Chaotic Systems
Wallinger, C. F., & Brandner, M. (2013) · Studies in computational intelligence · doi:10.1007/978-3-642-37781-5_4
Metadata
- Authors
- Céspedes, I., Huang, Y., Ophir, J., & Spratt, S.
- Affiliations
- The University of Texas Medical School Radiology Department - Ultrasonics Laboratory Houston, TX 77030
- Diasonics Ultrasound Inc. San Jose, CA
- ORCID
- Céspedes, I.
- Venue
- Ultrasonic Imaging
- Publisher
- SAGE Publications
- Published
- 1995-04
- Volume
- 17
- Issue
- 2
- Pages
- 142-171
- ISSN
- 0161-7346 (ISSN-L)
- 1096-0910
- OpenAlex
- W2044310882
- Cited by
- 436
- References
- 28
- Citations by year
- 2026: 10 · 2025: 15 · 2024: 11 · 2023: 21 · 2022: 16 · 2021: 17 · 2020: 19 · 2019: 25 · 2018: 22 · 2017: 18 · 2016: 10 · 2015: 20 · 2014: 21 · 2013: 17 · 2012: 16
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Ultrasonic Imaging (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca038515-07, 5r01ca060520-03)
- National Cancer Institute (R01-CA60520, P01-CA64579, R01-CA-38515)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Physical Sciences › Earth and Planetary Sciences › Oceanography › Underwater Acoustics Research
- Keywords
- time delay estimation, echo signal, cross correlation function, interpolation, parabolic interpolation, curve fitting, reconstruction filter, maximum likelihood estimation, bias, elastography, iterative reconstruction
- MeSH terms
- Computer Simulation, Humans, Image Processing, Computer-Assisted, Signal Processing, Computer-Assisted, Time Factors, Ultrasonography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.