Methods for Estimation of Subsample Time Delays of Digitized Echo Signals
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Time delay estimation (TDE) is commonly performed in practice by crosscorrelation of digitized echo signals. Since time delays are generally not integral multiples of the sampling period, the location of the largest sample of the crosscorrelation function (ccf) is an inexact estimator of the location of the peak. Therefore, one must interpolate between the samples of the ccf to improve the estimation precision. Using theory and simulations, we review and compare the performance of several methods for interpolation of the ccf. The maximum likelihood approach to interpolation is the application of a reconstruction filter to the discrete ccf. However, this method can only be approximated in practice and can be computationally intensive. For these reasons, a simple method is widely used that involves fitting a parabola (or other curve) to samples of the ccf in the neighborhood of its peak. We describe and compare two curve-fitting methods: parabolic and cosine interpolation. Curve-fitting interpolation can yield biased time-delay estimates, which may preclude the use of these methods in some applications. The artifactual effect of these bias errors on elasticity imaging by elastography is discussed. We demonstrate that reconstructive interpolation is unbiased. An iterative implementation of the reconstruction procedure is proposed that can reduce the Computation time significantly.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The generalized correlation method for estimation of time delay
Knapp, C., & Carter, G. (1976) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1976.1162830 · Cited by 4,433
Detection, Estimation, and Modulation Theory, Part I
Van Trees, H. L. (2001) · John Wiley & Sons, Inc. eBooks · doi:10.1002/0471221082 · Cited by 3,891
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Self-citationCoherence and time delay estimation
Carter, G. C. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13723 · Cited by 1,200
A digital signal processing approach to interpolation
Schafer, R. W., & Rabiner, L. R. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.9150 · Cited by 554
Algorithms for ambiguity function processing
Stein, S. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163621 · Cited by 496
Flax, S. W., & O’Donnell, M. (1988) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.9333 · Cited by 483
(1993) · NDT & E International · doi:10.1016/0963-8695(93)90667-j · Cited by 395
An overview on the time delay estimate in active and passive systems for target localization
Quazi, A. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163618 · Cited by 393
Angle Independent Ultrasonic Detection of Blood Flow
Trahey, G. E., Allison, J. W., & von Ramm, O. T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325938 · Cited by 386
Research works printed but not linked: 3
- Bendat J.S., 1986, Random Data: Analysis and Measurement
- Céspedes I., Elastography: Imaging of Biological Tissue Elasticity, Ph.D. Dissertation (Dept. of Electrical Engineering, University of Houston, Texas, 1993).
- Trahey G.E., 1988, IEEE Trans. Biomed. Eng., 34, 965
Cited by
Items 201–300 of 431
Basic Study on Detection of Outer Boundary of Arterial Wall Using Its Longitudinal Motion
Numata, T., Hasegawa, H., & Kanai, H. (2007) · Japanese Journal of Applied Physics · doi:10.1143/jjap.46.4900 · Cited by 13
Rodríguez, A., Svilainis, L., Dumbrava, V., et al. (2014) · NDT & E International · doi:10.1016/j.ndteint.2014.06.001 · Cited by 13
A PSF-Shape-Based Beamforming Strategy for Robust 2D Motion Estimation in Ultrafast Data
Saris, A. E. C. M., Fekkes, S., Nillesen, M. M., Hansen, H. H. G., & de Korte, C. L. (2018) · Applied Sciences · doi:10.3390/app8030429 · Cited by 17
Shear wave arrival time estimates correlate with local speckle pattern
McAleavey, S. A., Langdon, J., & Osapoetra, L. O. (2014) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2014.0158 · Cited by 12
Miyajo, A., & Hasegawa, H. (2018) · Japanese Journal of Applied Physics · doi:10.7567/jjap.57.07lf11 · Cited by 12
Yang, C., Li, G., Niu, F., et al. (2018) · Pure and Applied Geophysics · doi:10.1007/s00024-018-2075-7 · Cited by 12
Contrast analysis in ultrafast ultrasound blood flow imaging of jugular vein
Omura, M., Yagi, K., Nagaoka, R., & Hasegawa, H. (2023) · Journal of Medical Ultrasonics · doi:10.1007/s10396-023-01289-9 · Cited by 13
“The normalized cross-correlation function was up-sampled using the reconstructive interpolation method to estimate subsample displacement [27, 28].”
MethodMean Scatterer Spacing Estimation in Normal and Thermally Coagulated Ex Vivo Bovine Liver
Rubert, N. C., & Varghese, T. (2014) · Ultrasonic Imaging · doi:10.1177/0161734613511232 · Cited by 12
Implementation issues in ultrasonic flow imaging
Alam, S. K., & Parker, K. J. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00704-4 · Cited by 12
“Although a three-sample shift is adequate for not missing a peak, error in estimating the peak using interpolation increases when sampling interval increases (Alam and Ophir 2000; Céspedes et al. 1995).”
BackgroundAchilles tendon shear wave speed tracks the dynamic modulation of standing balance
Acuña, S. A., Ebrahimi, A., Pomeroy, R. L., Martin, J. A., & Thelen, D. G. (2019) · Physiological Reports · doi:10.14814/phy2.14298 · Cited by 9
Ebrahimi, A., Kuchler, R. L., Pomeroy, R. L., Loegering, I. F., Martin, J. A., & Thelen, D. G. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.05.023 · Cited by 11
Experimental validation of acoustic radiation force induced shear wave interference patterns
Hoyt, K., Hah, Z., Hazard, C., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/1/21 · Cited by 12
“Subsample interpolation using a parabolic function was employed to improve displacement estimation accuracy (Cespedes et al 1995).”
MethodP4A-2 An In-Vivo Study of Frame Rate Optimization for Myocardial Elastography
Luo, J., Lee, W.-N., Wang, S., et al. (2007) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2007.486 · Cited by 12
Separated Respiratory Phases for In Vivo Ultrasonic Thermal Strain Imaging
Yin, C., Wang, G., Xie, Y., Tu, J., Sun, W., Kong, X., Guo, X., & Zhang, D. (2022) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2022.3149287 · Cited by 11
Stress measurement by laser grating based on laser ultrasonic technology
Qian, F., Xing, G., Wang, K., et al. (2024) · Measurement · doi:10.1016/j.measurement.2024.115049 · Cited by 11
In vivo carotid strain imaging using principal strains in longitudinal view
Meshram, N. H., Mitchell, C., Wilbrand, S. M., et al. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab15c9 · Cited by 11
“Another approach is to use lateral interpolation of the radio frequency (RF) data coupled with interpolation within the similarity matrices used for displacement tracking in elastography applications (Céspedes et al., 1995; McCormick and Varghese, 2013).”
MethodAnalysis of 2-D motion tracking in ultrasound with dual transducers
Abeysekera, J. M., Azar, R. Z., Göksel, O., Rohling, R. N., & Salcudean, S. E. (2011) · Ultrasonics · doi:10.1016/j.ultras.2011.07.011 · Cited by 11
Costa‐Júnior, J. F. S., Elsztain, M. A. D., de Sá, A. M. F. L. M., & Machado, J. C. (2017) · Experimental Mechanics · doi:10.1007/s11340-017-0254-6 · Cited by 11
Applications of Digital Signal Processing Methods in Ultrasonic Flowmeters
Gerasimov, S. I., Glushnev, V. D., & Panov, M. (2018) · International Conference on Information Technologies in Engineering Education (Inforino) · doi:10.1109/inforino.2018.8581723 · Cited by 11
“For the stronger reduction of the interpolation error, well-known methods of digital interpolation [2, 3, 20-25] based on the signal reconstruction at intermediate points of the original lowfrequency samples sequence by digital filters [3, 4], in particular, the UPS upsampling method.”
BackgroundMethodInvestigation of parametric spectral estimation techniques for elasticity imaging
Hoyt, K., Forsberg, F., & Ophir, J. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.04.013 · Cited by 11
Self-citationImage and Signal Processing in Intravascular Ultrasound
Li, W. (1997) · RePub (Erasmus University Rotterdam) · Cited by 10
In vivo bistatic dual-aperture ultrasound imaging and elastography of the abdominal aorta
van Hal, V. H. J., de Hoop, H., van Sambeek, M. R. H. M., Schwab, H., & Lopata, R. G. P. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1320456 · Cited by 11
Feasibility Assessment of LDACS-Based Wide Area Multilateration
Filip, A., Bellido-Manganell, M. A., Gräupl, T., et al. (2022) · IEEE/AIAA Digital Avionics Systems Conference (DASC) · doi:10.1109/dasc55683.2022.9925808 · Cited by 10
Yamane, R., Mori, S., Arakawa, M., et al. (2023) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/acc07a · Cited by 10
Nilsson, T., Ahlgren, Å. R., Albinsson, J., Segstedt, S., Nilsson, J. Å., Jansson, T. T., Persson, H. W., & Cinthio, M. (2013) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2013.0449 · Cited by 10
“Upsampling is time-consuming and the results from parabolic interpolation may be biased [13].”
BackgroundTwo-Dimensional Simulations of Displacement Accumulation Incorporating Shear Strain
Bayer, M., Hall, T. J., Neves, L. P., et al. (2013) · Ultrasonic Imaging · doi:10.1177/0161734613511231 · Cited by 10
Strain measurement from 3D micro-CT images of a breast-mimicking phantom
Lee, S. Y., Kim, G. W., Han, B. H., & Cho, M. H. (2011) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2011.01.001 · Cited by 10
Fourier-Domain Shift Matching: A Robust Time-of-Flight Approach for Shear Wave Speed Estimation
Rosen, D., & Jiang, J. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2811738 · Cited by 10
Interfibrillar shear behavior is altered in aging tendon fascicles
Muench, B. J., Thelen, D. G., & Henak, C. R. (2019) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-019-01251-0 · Cited by 11
布目, 宗., Nagaoka, R., & Hasegawa, H. (2020) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ab78e7 · Cited by 10
Anti-aliasing method for ultrasonic 2D phase-sensitive motion estimator
Mozumi, M., Nagaoka, R., Cinthio, M., & Hasegawa, H. (2020) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ab8c9a · Cited by 10
Atypical triceps surae force and work patterns underlying gait in children with cerebral palsy
Ebrahimi, A., Schwartz, M. H., Martin, J. A., Novacheck, T. F., & Thelen, D. G. (2022) · Journal of Orthopaedic Research® · doi:10.1002/jor.25307 · Cited by 10
Uniform precision ultrasound strain imaging
Treece, G. M., Lindop, J. E., Gee, A., et al. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1330 · Cited by 10
Liu, Z., He, Q., & Luo, J. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2895374 · Cited by 10
Zahiri-Azar, R., Göksel, O., Yao, T. S., et al. (2008) · doi:10.1109/iembs.2008.4650479 · Cited by 10
“This is consistent with the results previously published for 1D tracking [10], [ 6 ].”
BackgroundResultZhang, X., Fan, C., Yang, J., et al. (2026) · Measurement · doi:10.1016/j.measurement.2026.121291 · Cited by 9
Impact of spacing of ultrasound receiving beams on estimation of 2D motion velocity
Mozumi, M., Omura, M., Nagaoka, R., Cinthio, M., & Hasegawa, H. (2021) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/abeac0 · Cited by 9
Needle Insertion Study Using Ultrasound-Based 2D Motion Tracking
Dehghan, E., & Salcudean, S. E. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-85990-1_79 · Cited by 9
“To find the lateral displacement with higher resolution sub-sampling using quadratic functions was employed [ 11 ].”
MethodA combination of parabolic and grid slope interpolation for 2D tissue displacement estimations
Albinsson, J., Ahlgren, Å. R., Jansson, T. T., & Cinthio, M. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1593-7 · Cited by 9
Wang, Y., Bayer, M., Jiang, J., et al. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2948984 · Cited by 9
A new differential positioning method using modulation correlation of signals of opportunity
Webb, T. A., Groves, P. D., Cross, P. A., et al. (2010) · IEEE/ION Position Location and Navigation Symposium · doi:10.1109/plans.2010.5507270 · Cited by 9
Quantification of Endogenous Brain Tissue Displacement Imaging by Radiofrequency Ultrasound
Jurkonis, R., Makūnaitė, M., Baranauskas, M., Lukoševičius, A., Sakalauskas, A., Matijošaitis, V., & Rastenytė, D. (2020) · Diagnostics · doi:10.3390/diagnostics10020057 · Cited by 9
Schouten, G., & Steckel, J. (2019) · IEEE Signal Processing Magazine · doi:10.1109/msp.2019.2903274 · Cited by 10
“This sampling frequency also corresponds to a maximum range accuracy of 4 mm, which can be further enhanced by interpolation [24].”
BackgroundZahiri-Azar, R., & Salcudean, S. E. (2006) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2006.309 · Cited by 11
Ultrasonic Methods for Assessment of Tissue Motion in Elastography
Jiang, J., & Peng, B. (2018) · doi:10.1002/9781119021520.ch4 · Cited by 9
Ultrasound propagation in trabecular bone: A numerical study of the influence of microcracks
Callé, S., Moreschi, H., Renaud, G., et al. (2013) · Ultrasonics · doi:10.1016/j.ultras.2013.08.003 · Cited by 8
Fast Randomized Singular Value Decomposition-Based Clutter Filtering for Shear Wave Imaging
Wang, Y., He, Q., & Luo, J. (2020) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2020.3005426 · Cited by 8
Wang, Y., Xie, X., He, Q., et al. (2022) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2022.3148332 · Cited by 8
Small Ultrasound-Based Corrosion Sensor for Intraday Corrosion Rate Estimation
Thibbotuwa, U. C., Cortés, A., & Irizar, A. (2022) · Sensors · doi:10.3390/s22218451 · Cited by 12
Mozumi, M., Omura, M., Nagaoka, R., Saito, K., & Hasegawa, H. (2023) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/acc07b · Cited by 8
Intravascular palpography for vulnerable plaque assessment
Schaar, J. A., van der Steen, A., & Mastik, F. (2007) · CRC Press eBooks · doi:10.3109/9781439804537-19 · Cited by 8
Cross-spectral phase method for time delay estimation in acoustic leak detection
Uchendu, N., Muggleton, J. M., & White, P. R. (2025) · Applied Acoustics · doi:10.1016/j.apacoust.2025.110695 · Cited by 8
“Another key advantage is its provision of confidence limits for leak location, enhancing reliability compared to methods that only provide a single estimate without uncertainty quantification.”
Saris, A. E. C. M., Nillesen, M. M., Fekkes, S., et al. (2015) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2015.0421 · Cited by 7
“A lot has been published on fitting 1D curves to estimate motion in 1D [10] and 2D, where for 2D the fitting is performed in each direction of the pattern matching function separately [5, 8, 11].”
BackgroundManogharan, P., & Shokouhi, P. (2023) · NDT & E International · doi:10.1016/j.ndteint.2023.102834 · Cited by 7
Adjacent Tissues Reduce Shear Wave Speeds in Axially Loaded Tendons
Blank, J. L., & Thelen, D. G. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.106138 · Cited by 7
A Comparison of Time Delay Estimation Methods for Periodic Signals
Wiens, T. K., & Bradley, S. G. (2009) · Cited by 7
Filter-based compounded delay estimation with application to strain imaging
Liu, P., & Liu, D. (2011) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.2058 · Cited by 7
Honjo, Y., Hasegawa, H., & Kanai, H. (2012) · Japanese Journal of Applied Physics · doi:10.1143/jjap.51.07gf06 · Cited by 7
Göksel, O., Zahiri-Azar, R., & Salcudean, S. E. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352750 · Cited by 7
“The performance of some of these 1D sub-sampling methods such as parabolic and cosine fitting has been studied in the literature [7], [8].”
BackgroundReal Time Strain Imaging — a new Ultrasonic Method for Cancer Detection: First Study Results
Lorenz, A., Pesavento, A., Scheipers, U., et al. (2001) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.2001.46.s1.62 · Cited by 7
Cepstral method for time delay estimation in acoustic leak detection
Uchendu, N., Muggleton, J. M., & White, P. R. (2025) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2025.113448 · Cited by 6
Intraventricular blood flow vector and streamline imaging using high frame rate cardiac ultrasound
Takahashi, H., Hasegawa, H., & Kanai, H. (2014) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2014.0084 · Cited by 6
“The distribution of velocity vectors estimated by the ST with 2D-CF averaging were bridged with a reconstructive interpolation [9] to obtain the densely-mapped velocity vectors.”
MethodRegional shear wave speeds track regional axial stress in nonuniformly loaded fibrous soft tissues
Blank, J. L., Thelen, D. G., & Roth, J. D. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112071 · Cited by 6
Venet, M., Baranger, J., Malik, A., Nguyen, M. B., Mital, S. R., Friedberg, M. K., Pernot, M., Papadacci, C., Salles, S., Chaturvedi, R. R., et al. (2025) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeaf089 · Cited by 10
Mozumi, M., Nagaoka, R., & Hasegawa, H. (2021) · Ultrasonics · doi:10.1016/j.ultras.2021.106650 · Cited by 6
Implementation of Constrained Swept Synthetic Aperture Using a Mechanical Fixture
Bottenus, N. B. (2023) · Applied Sciences · doi:10.3390/app13084797 · Cited by 7
Verma, P., & Doyley, M. M. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.05.019 · Cited by 6
Ultrasonic blood flowmeter with a novel Xero algorithm for a mechanical circulatory support system
Lew, H. M., Shin, H., Lee, M. H., et al. (2021) · Ultrasonics · doi:10.1016/j.ultras.2021.106457 · Cited by 6
Metz, D. (2022) · Nippon Onkyo Gakkaishi/Acoustical science and technology/Nihon Onkyo Gakkaishi · doi:10.1250/ast.43.125 · Cited by 6
“The bias error typically associated with this approach is assumed to be reasonably small, as the sampling rate exceeds the center frequency of the 4–8 Hz processing band by more than one order of magnitude [14].”
BackgroundNguyen, T.-T., Cheng, C.-H., Liu, D., & Le, M.-H. (2022) · Electronics · doi:10.3390/electronics11070985 · Cited by 8
Saharkhiz, N., Kamimura, H. A. S., & Konofagou, E. E. (2023) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2023.03.025 · Cited by 6
Ultrasonic time-of-flight method for non-invasive physiological monitoring of the human brain
Ragauskas, A. J., Daubaris, G., Petkus, V., et al. (2008) · Ultrasound · doi:10.5755/j01.u.63.2.17070 · Cited by 6
Phase root seeking and the Cramer-Rao-Lower bound for strain estimation
Pesavento, A., Lorenz, A., & Ermert, H. (2003) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.1999.849317 · Cited by 6
“in [ 2 ]. In this paper, the strain estimator is also compared to its Cramer-Rao-Lower Bound.”
ResultDirect phase-based strain estimator for ultrasound tissue elasticity imaging
Bae, U., & Kim, Y. R. (2005) · doi:10.1109/iembs.2004.1403421 · Cited by 6
Effect of Clutter Filter in High-Frame-Rate Ultrasonic Backscatter Coefficient Analysis
Omura, M., Yagi, K., Nagaoka, R., Yoshida, K., Yamaguchi, T., & Hasegawa, H. (2023) · Sensors · doi:10.3390/s23052639 · Cited by 5
Kadri, U. (2024) · Scientific Reports · doi:10.1038/s41598-024-60529-1 · Cited by 5
Tracked Ultrasound Elastography (TrUE)
Foroughi, P., Rivaz, H. J., Fleming, I. N., et al. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-15745-5_2 · Cited by 5
“We have implemented normalized cross-correlation (NCC) [10] to recover the displacements and least squares estimation to calculate the strain.”
MethodDelay Estimation Using Instantaneous Frequency and Phase Difference—Simulation Study
Liu, P., & Liu, D. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2524690 · Cited by 5
Honjo, Y., Hasegawa, H., & Kanai, H. (2012) · Japanese Journal of Applied Physics · doi:10.7567/jjap.51.07gf06 · Cited by 5
Liang, H., Zhou, L., Wells, P. N. T., et al. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.10.017 · Cited by 5
Global Tracking of Myocardial Motion in Ultrasound Sequence Images: A Feasibility Study
Wang, Y., Liu, X., Song, X., et al. (2019) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2020026 · Cited by 5
Chen, J., Zhu, C., Pu, Y., Rui, Y., Liu, B., & Apel, D. B. (2025) · Earth energy science. · doi:10.1016/j.ees.2025.03.002 · Cited by 5
Nagai, Y., Mori, S., Arakawa, M., & Kanai, H. (2023) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/acba26 · Cited by 5
Navigator Echo Motion Artifact Suppression in Synthetic Aperture Ultrasound Imaging
Kadah, Y. M., El‐Sharkawy, A. M., & Youssef, A. M. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836501 · Cited by 4
Teixeira, C., Mendes, L. G. A., Ruano, M. G., & Pereira, W. C. D. A. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.024 · Cited by 5
Development and evaluation of ligament phantoms targeted for shear wave tensiometry
Arant, L. R., & Roth, J. D. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104984 · Cited by 4
Remote Hydroacoustic Detection of an Airplane Crash
Metz, D., Obana, K., & Fukao, Y. (2022) · Pure and Applied Geophysics · doi:10.1007/s00024-022-03117-6 · Cited by 4
Nguyen, T. H., Chabah, M., & Sintès, C. (2015) · MTS/IEEE OCEANS Conference (OCEANS) · doi:10.23919/oceans.2015.7404526 · Cited by 4
Yang, W., Liu, J., Cheng, J., et al. (2015) · Tectonophysics · doi:10.1016/j.tecto.2015.03.002 · Cited by 4
“3c) (Céspedes et al., 1995).”
Fundamental analysis of lateral displacement estimation quality in ultrasound elastography
Luo, J., & Konofagou, E. E. (2009) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2009.5193084 · Cited by 4
3D cardiac motion estimation using RF signal decorrelation
Garson, C. D., Li, Y., & Hossack, J. A. (2008) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2008.0115 · Cited by 4
“Subsample motion was estimated by fitting cosines to the 2D correlation estimates and computing the maximum of the cosine functions [15, 16].”
MethodHigh Precision Positioning with a Sensor Network
Concha, J. I., & Oh, J.-H. (2005) · doi:10.1109/issnip.2004.1417436 · Cited by 4
“They depend on the precise mathematical assumptions regarding the signals and noise [1][4].”
BackgroundMultiparametric QUS Analysis for Placental Tissue Characterization
Deeba, F., Ma, M., Pesteie, M., Terry, J., Pugash, D., Hutcheon, J. A., Mayer, C., Salcudean, S. E., & Rohling, R. N. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513095 · Cited by 4
Gerasimov, S., & Zhelbakov, I. N. (2018) · International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM) · doi:10.1109/icieam.2018.8728593 · Cited by 4
“An additional option to improve the accuracy of determining tP can be use the CCF interpolation [35, 39, 41].”
BackgroundMethodInfluentialMirzaei, M., Asif, A. A., Fortin, M., et al. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1804.05305 · Cited by 4
“f windows in the pre-compressed image. Maximization of NCC only provides an integer displacement estimate, and interpolation should be performed to nd a more accurate sub-pixel displacement estimate (Cspedes et al., 1995; Jiang and Hall, 2015; Zahiri-Azar et al., 2010). In this paper a novel technique is introduced to…”
MethodEbrahimi, A., Martin, J. A., Schwartz, M. H., Novacheck, T. F., & Thelen, D. G. (2023) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2023.105871 · Cited by 4
3-D motion tracking and vascular strain imaging using bistatic dual aperture ultrasound acquisitions
de Hoop, H., Maas, E. J., Muller, J.-W., Schwab, H., & Lopata, R. G. P. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad9db2 · Cited by 3
Gachouch, O., Giammarinaro, B., Kangot, T., et al. (2025) · Sensors · doi:10.3390/s25020385 · Cited by 3
On time delay interpolation for improved acoustic reflector localization
Rosseel, H., & van Waterschoot, T. (2025) · The Journal of the Acoustical Society of America · doi:10.1121/10.0039541 · Cited by 3
On the Detecting Bandwidth of Chirped Pulse ϕ-OTDR
Ye, Z., Xu, P., Wen, K., et al. (2025) · Journal of Lightwave Technology · doi:10.1109/jlt.2025.3628906 · Cited by 3
Metadata
- Authors
- Céspedes, I., Huang, Y., Ophir, J., & Spratt, S.
- Affiliations
- The University of Texas Medical School Radiology Department - Ultrasonics Laboratory Houston, TX 77030
- Diasonics Ultrasound Inc. San Jose, CA
- ORCID
- Céspedes, I.
- Venue
- Ultrasonic Imaging
- Publisher
- SAGE Publications
- Published
- 1995-04
- Volume
- 17
- Issue
- 2
- Pages
- 142-171
- ISSN
- 0161-7346 (ISSN-L)
- 1096-0910
- OpenAlex
- W2044310882
- Cited by
- 436
- References
- 28
- Citations by year
- 2026: 10 · 2025: 15 · 2024: 11 · 2023: 21 · 2022: 16 · 2021: 17 · 2020: 19 · 2019: 25 · 2018: 22 · 2017: 18 · 2016: 10 · 2015: 20 · 2014: 21 · 2013: 17 · 2012: 16
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Ultrasonic Imaging (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca038515-07, 5r01ca060520-03)
- National Cancer Institute (R01-CA60520, P01-CA64579, R01-CA-38515)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Physical Sciences › Earth and Planetary Sciences › Oceanography › Underwater Acoustics Research
- Keywords
- time delay estimation, echo signal, cross correlation function, interpolation, parabolic interpolation, curve fitting, reconstruction filter, maximum likelihood estimation, bias, elastography, iterative reconstruction
- MeSH terms
- Computer Simulation, Humans, Image Processing, Computer-Assisted, Signal Processing, Computer-Assisted, Time Factors, Ultrasonography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.