Methods for Estimation of Subsample Time Delays of Digitized Echo Signals
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Time delay estimation (TDE) is commonly performed in practice by crosscorrelation of digitized echo signals. Since time delays are generally not integral multiples of the sampling period, the location of the largest sample of the crosscorrelation function (ccf) is an inexact estimator of the location of the peak. Therefore, one must interpolate between the samples of the ccf to improve the estimation precision. Using theory and simulations, we review and compare the performance of several methods for interpolation of the ccf. The maximum likelihood approach to interpolation is the application of a reconstruction filter to the discrete ccf. However, this method can only be approximated in practice and can be computationally intensive. For these reasons, a simple method is widely used that involves fitting a parabola (or other curve) to samples of the ccf in the neighborhood of its peak. We describe and compare two curve-fitting methods: parabolic and cosine interpolation. Curve-fitting interpolation can yield biased time-delay estimates, which may preclude the use of these methods in some applications. The artifactual effect of these bias errors on elasticity imaging by elastography is discussed. We demonstrate that reconstructive interpolation is unbiased. An iterative implementation of the reconstruction procedure is proposed that can reduce the Computation time significantly.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The generalized correlation method for estimation of time delay
Knapp, C., & Carter, G. (1976) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1976.1162830 · Cited by 4,433
Detection, Estimation, and Modulation Theory, Part I
Van Trees, H. L. (2001) · John Wiley & Sons, Inc. eBooks · doi:10.1002/0471221082 · Cited by 3,891
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Self-citationCoherence and time delay estimation
Carter, G. C. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13723 · Cited by 1,200
A digital signal processing approach to interpolation
Schafer, R. W., & Rabiner, L. R. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.9150 · Cited by 554
Algorithms for ambiguity function processing
Stein, S. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163621 · Cited by 496
Flax, S. W., & O’Donnell, M. (1988) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.9333 · Cited by 483
(1993) · NDT & E International · doi:10.1016/0963-8695(93)90667-j · Cited by 395
An overview on the time delay estimate in active and passive systems for target localization
Quazi, A. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163618 · Cited by 393
Angle Independent Ultrasonic Detection of Blood Flow
Trahey, G. E., Allison, J. W., & von Ramm, O. T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325938 · Cited by 386
Research works printed but not linked: 3
- Bendat J.S., 1986, Random Data: Analysis and Measurement
- Céspedes I., Elastography: Imaging of Biological Tissue Elasticity, Ph.D. Dissertation (Dept. of Electrical Engineering, University of Houston, Texas, 1993).
- Trahey G.E., 1988, IEEE Trans. Biomed. Eng., 34, 965
Cited by
Items 401–431 of 431
Accurate Estimation Method of Arterial Wall Movement in Longitudinal Direction
Iwamori, K., Mori, S., Arakawa, M., et al. (2019) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2019.8925634
“In the block matching method, the normalized correlation function was interpolated using the reconstructive interpolation to track the micron-order movement between frames [8, 9, 11].”
MethodMuromoto, J., Murotsuki, J., Miyashita, S., Hasegawa, H., Taki, H., Kanai, H., & Yaegashi, N. (2020) · Journal of obstetrics and gynaecology research · doi:10.1111/jog.14402 · Cited by 1
“To estimate the time delay, which is smaller than the frame interval, reconstructive interpolation was used to interpolate the cross-correlation function.(8) We confirmed that the sampling frequency, which corresponds to the frame rate, was high enough to include all frequency components of the”
MethodRivera, L., Vera, A., Ramos, A., et al. (2007)
Two-Dimensional Blood Velocity Estimation for Intracardiac Flow Assessment
Fadnes, S. (2014) · BIBSYS Brage (BIBSYS (Norway))
Intravascular Elastography: from idea to clinical tool
de Korte, C. L., Mastik, F., Schaar, J., et al. (2003) · Springer eBooks · doi:10.1007/978-4-431-67871-7_7
Souchon, R. (2004) · Cited by 1
Schaar, J. A., de Korte, C. L., Mastik, F., et al. (2006) · doi:10.1002/9780470987575.ch19
Proposed Methodology for Jitter Measurement
Anthonys, G. (2021) · Springer eBooks · doi:10.1007/978-3-030-94159-8_5
Velocity resolution improvement for high temporal resolution ultrasonic transducer
Nguyễn, T. T., Espinoza, A. W., Hyler, S., et al. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092291
Digital Coherent Ranging Accuracy Improvement Method Based on Interpolation Resampling AlgorithmPreprint
Li, C., Sun, F., Sun, J., et al. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4640730
Chaoyang, 李. L., Jianfeng, 孙. S., Zhiyong, 卢. L., et al. (2024) · Laser & Optoelectronics Progress · doi:10.3788/lop240428
Omura, M., Yagi, K., Nagaoka, R., et al. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.5061423
Cepstral Method for Time Delay Estimation in Acoustic Leak DetectionPreprint
Uchendu, N., Muggleton, J. M., & White, P. R. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.5069845
Shear Wave Propagation as a Noninvasive Metric of Loading and Microdamage in Tendon FasciclesPreprint
Kotha, S., Blank, J. L., Kahr, S. M., et al. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5084898
Contrast analysis in ultrafast ultrasound blood flow imaging of jugular vein
Omura, M., Yagi, K., Nagaoka, R., & Hasegawa, H. (2025) · Choonpa Igaku · doi:10.3179/jjmu.jjmu.k.34
Seismic wave experiments in granular media with applications to asteroids
Gallot, T., Sedofeito, C., Ginares, A., & Tancredi, G. (2025) · Planetary and Space Science · doi:10.1016/j.pss.2025.106153 · Cited by 1
Milakovic, L., Ingram, M., Dandois, F., et al. (2025) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2025.109213
Said, G. (2006) · OpenGrey (Institut de l'Information Scientifique et Technique)
Bader, M., Ning, I. L. C., Nihei, K. T., et al. (2026) · Second International Meeting for Applied Geoscience & Energy · doi:10.1190/image2025-4305216.1
Jeger‐Madiot, N. (2017) · theses.fr (ABES) · doi:10.70675/1c0d8f4az2f27z4c6eza9f2zcbc8d27e92dd · Cited by 2
Deng, J., Zhang, J., Cui, H., et al. (2026) · The Journal of the Acoustical Society of America · doi:10.1121/10.0043473
C‑Siam: a complex-valued Siamese network for ultrasound-based vascular motion estimation
Sejuty, A. T., NGUYEN, N. C. P., & Park, S. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.110889
Chen, G., Xu, L., Sun, F., Liu, H., Zhang, C., Qian, H., Li, F., Xiang, X., Shi, F., & Xu, X. X. (2026) · Measurement · doi:10.1016/j.measurement.2026.122382
Pradhan, S. P., Yavari, A., Lindley, I. D., Binesh, N., Matusov, Y. P., Ghafourian, K., Pedrizzetti, G., & Kheradvar, A. (2026) · Annals of Biomedical Engineering · doi:10.1007/s10439-026-04335-y
“…ZNCC as follows: where Where ( This dual-tracker approach mitigates the complementary failure modes of each method: sequential tracking accumulates drift over time as small frame-to-frame errors compound, while reference tracking degrades due to progressive speckle decorrelation [21–25].”
Shifting gears to power human walking
Martin, J. A., Welte, L., Knurr, K. A., et al. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2524115123
NPRS Performance for GNSS-free NB-IoT NTN Positioning
Gallardo-Duval, I., Ruiz-de-Azua, J. A., Rovira-Garcia, A., et al. (2026) · doi:10.1109/navitec202669090.2026.11692542
Yin, J., He, J., Wang, X., et al. (2026) · Sensing and Imaging · doi:10.1007/s11220-026-00895-4
“Envelope-based arrival detection, analytic-signal processing, and correlation-based time-delay estimation have been widely used to improve timing robustness in ultrasonic and photoacoustic measurements [ 25–28].”
Metadata
- Authors
- Céspedes, I., Huang, Y., Ophir, J., & Spratt, S.
- Affiliations
- The University of Texas Medical School Radiology Department - Ultrasonics Laboratory Houston, TX 77030
- Diasonics Ultrasound Inc. San Jose, CA
- ORCID
- Céspedes, I.
- Venue
- Ultrasonic Imaging
- Publisher
- SAGE Publications
- Published
- 1995-04
- Volume
- 17
- Issue
- 2
- Pages
- 142-171
- ISSN
- 0161-7346 (ISSN-L)
- 1096-0910
- OpenAlex
- W2044310882
- Cited by
- 436
- References
- 28
- Citations by year
- 2026: 10 · 2025: 15 · 2024: 11 · 2023: 21 · 2022: 16 · 2021: 17 · 2020: 19 · 2019: 25 · 2018: 22 · 2017: 18 · 2016: 10 · 2015: 20 · 2014: 21 · 2013: 17 · 2012: 16
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Ultrasonic Imaging (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca038515-07, 5r01ca060520-03)
- National Cancer Institute (R01-CA60520, P01-CA64579, R01-CA-38515)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Physical Sciences › Earth and Planetary Sciences › Oceanography › Underwater Acoustics Research
- Keywords
- time delay estimation, echo signal, cross correlation function, interpolation, parabolic interpolation, curve fitting, reconstruction filter, maximum likelihood estimation, bias, elastography, iterative reconstruction
- MeSH terms
- Computer Simulation, Humans, Image Processing, Computer-Assisted, Signal Processing, Computer-Assisted, Time Factors, Ultrasonography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.