Nonholonomic Modeling of Needle Steering
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
As a flexible needle with a bevel tip is pushed through soft tissue, the asymmetry of the tip causes the needle to bend. We propose that, by using nonholonomic kinematics, control, and path planning, an appropriately designed needle can be steered through tissue to reach a specified 3D target. Such steering capability could enhance targeting accuracy and may improve outcomes for percutaneous therapies, facilitate research on therapy effectiveness, and eventually enable new minimally invasive techniques. In this paper, we consider a first step toward active needle steering: design and experimental validation of a nonholonomic model for steering flexible needles with bevel tips. The model generalizes the standard three degree-of-freedom (DOF) nonholonomic unicycle and bicycle models to 6 DOF using Lie group theory. Model parameters are fit using experimental data, acquired via a robotic device designed for the specific purpose of inserting and steering a flexible needle. The experiments quantitatively validate the bevel-tip needle steering model, enabling future research in flexible needle path planning, control, and simulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Introduction to Robotic Manipulation
Murray, R. M., Li, Z., & Sastry, S. S. (2017) · CRC Press eBooks · doi:10.1201/9781315136370 · Cited by 6,694
Jemal, A., Tiwari, R. C., Murray, T., Ghafoor, A., Samuels, A., Ward, E., Feuer, E. J., & Thun, M. J. (2004) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.54.1.8 · Cited by 3,984
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Force Modeling for Needle Insertion Into Soft Tissue
Okamura, A. M., Simone, C., & O'Leary, M. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831542 · Cited by 830
Self-citationBiomechanics: Mechanical Properties of Living Tissues, 2nd ed.
Fung, Y. C., & Cowin, S. C. (1994) · Journal of Applied Mechanics · doi:10.1115/1.2901550 · Cited by 745
Nonholonomic Modeling of Needle Steering
Webster, R. J., Cowan, N. J., Chirikjian, G., & Okamura, A. M. (2006) · Springer Tracts in Advanced Robotics · doi:10.1007/11552246_4 · Cited by 527
Self-citationNeedle insertion modeling and simulation
DiMaio, S. P., & Salcudean, S. E. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817044 · Cited by 518
A telerobotic assistant for laparoscopic surgery
Taylor, R. H., Funda, J., Eldridge, B., Gomory, S., Gruben, K., LaRose, D., Talamini, M., Kavoussi, L., & Anderson, J. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391776 · Cited by 392
Ultra-Early Hemostatic Therapy for Intracerebral Hemorrhage
Mayer, S. A. (2003) · Stroke · doi:10.1161/01.str.0000046458.67968.e4 · Cited by 215
A Surgery Simulation Supporting Cuts and Finite Element Deformation
Nienhuys, H.-W., & van der Stappen, A. F. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_18 · Cited by 131
Needle Steering and Model-Based Trajectory Planning
DiMaio, S., & Salcudean, S. E. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39899-8_5 · Cited by 128
System for Robotically Assisted Percutaneous Procedures with Computed Tomography Guidance
Masamune, K., Gabor Fichtinger, A., Patriciu, A., Susil, R. C., Taylor, R. H., Kavoussi, L. R., Anderson, J. H., Sakuma, I., Dohi, T., & Stoianovici, D. S. (2001) · Computer Aided Surgery · doi:10.1002/igs.10024 · Cited by 120
Data book on mechanical properties of living cells, tissues, and organs
阿部, 博., 林, 紘., & 佐藤, 正. (1996) · Springer eBooks · Cited by 119
Robotic needle insertion: effects of friction and needle geometry
O'Leary, M. D., Simone, C., Washio, T., Yoshinaka, K., & Okamura, A. M. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2003.1241851 · Cited by 103
Self-citationSensorless planning for medical needle insertion procedures
Alterovitz, R., Goldberg, K., Pouliot, J., Taschereau, R., & Hsu, I.-C. J. (2004) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2003.1249671 · Cited by 83
Schemes for the identification of tissue types and boundaries at the tool point for surgical needles
Brett, P. N., Harrison, A. J., & Thomas, T. A. (2000) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.826856 · Cited by 80
A computational technique for interactive needle insertions in 3D nonlinear material
Nienhuys, H.-W., & van der Stappen, A. F. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1308127 · Cited by 65
Baumann, S. B., Noll, D. C., Kondziolka, D. S., Schneider, W., Nichols, T. E., Mintun, M. A., Lewine, J. D., Yonas, H., Orrison, W. W., & Sclabassi, R. J. (1995) · Journal of Image Guided Surgery · doi:10.1002/(sici)1522-712x(1995)1:4<242::aid-igs7>3.0.co;2-a · Cited by 56
Ulmer, S. C. (2000) · Postgraduate Medicine · doi:10.3810/pgm.2000.5.1.1062 · Cited by 34
Dudek, A. Z., Larson, T. A., Mellskog, C. E., Bloss, L. P., & Obasaju, C. K. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.22.14_suppl.2141 · Cited by 14
Cited by
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Self-citationContinuum Robots for Medical Applications: A Survey
Burgner-Kahrs, J., Rucker, D. C., & Choset, H. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2489500 · Cited by 1,557
A soft robot that navigates its environment through growth
Hawkes, E. W., Blumenschein, L. H., Greer, J. D., & Okamura, A. M. (2017) · Science Robotics · doi:10.1126/scirobotics.aan3028 · Cited by 968
Self-citationMotion planning with sequential convex optimization and convex collision checking
Schulman, J., Duan, Y., Ho, J., Lee, A., Awwal, I., Bradlow, H., Pan, J., Patil, S., Goldberg, K., & Abbeel, P. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364914528132 · Cited by 866
Mechanics of Precurved-Tube Continuum Robots
Webster, R. J., Romano, J. M., & Cowan, N. J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2006868 · Cited by 485
Self-citation
Metadata
- Authors
- Webster, R. J., Kim, J. S., Cowan, N. J., Chirikjian, G. S., & Okamura, A. M.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2006-05
- Volume
- 25
- Issue
- 5-6
- Pages
- 509-525
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2107550832
- Cited by
- 633
- References
- 20
- FWCI
- 19.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.