Nonholonomic Modeling of Needle Steering
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
As a flexible needle with a bevel tip is pushed through soft tissue, the asymmetry of the tip causes the needle to bend. We propose that, by using nonholonomic kinematics, control, and path planning, an appropriately designed needle can be steered through tissue to reach a specified 3D target. Such steering capability could enhance targeting accuracy and may improve outcomes for percutaneous therapies, facilitate research on therapy effectiveness, and eventually enable new minimally invasive techniques. In this paper, we consider a first step toward active needle steering: design and experimental validation of a nonholonomic model for steering flexible needles with bevel tips. The model generalizes the standard three degree-of-freedom (DOF) nonholonomic unicycle and bicycle models to 6 DOF using Lie group theory. Model parameters are fit using experimental data, acquired via a robotic device designed for the specific purpose of inserting and steering a flexible needle. The experiments quantitatively validate the bevel-tip needle steering model, enabling future research in flexible needle path planning, control, and simulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Introduction to Robotic Manipulation
Murray, R. M., Li, Z., & Sastry, S. S. (2017) · CRC Press eBooks · doi:10.1201/9781315136370 · Cited by 6,694
Jemal, A., Tiwari, R. C., Murray, T., Ghafoor, A., Samuels, A., Ward, E., Feuer, E. J., & Thun, M. J. (2004) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.54.1.8 · Cited by 3,984
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Force Modeling for Needle Insertion Into Soft Tissue
Okamura, A. M., Simone, C., & O'Leary, M. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831542 · Cited by 830
Self-citationBiomechanics: Mechanical Properties of Living Tissues, 2nd ed.
Fung, Y. C., & Cowin, S. C. (1994) · Journal of Applied Mechanics · doi:10.1115/1.2901550 · Cited by 745
Nonholonomic Modeling of Needle Steering
Webster, R. J., Cowan, N. J., Chirikjian, G., & Okamura, A. M. (2006) · Springer Tracts in Advanced Robotics · doi:10.1007/11552246_4 · Cited by 527
Self-citationNeedle insertion modeling and simulation
DiMaio, S. P., & Salcudean, S. E. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817044 · Cited by 518
A telerobotic assistant for laparoscopic surgery
Taylor, R. H., Funda, J., Eldridge, B., Gomory, S., Gruben, K., LaRose, D., Talamini, M., Kavoussi, L., & Anderson, J. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391776 · Cited by 392
Ultra-Early Hemostatic Therapy for Intracerebral Hemorrhage
Mayer, S. A. (2003) · Stroke · doi:10.1161/01.str.0000046458.67968.e4 · Cited by 215
A Surgery Simulation Supporting Cuts and Finite Element Deformation
Nienhuys, H.-W., & van der Stappen, A. F. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_18 · Cited by 131
Cited by
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Self-citationContinuum Robots for Medical Applications: A Survey
Burgner-Kahrs, J., Rucker, D. C., & Choset, H. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2489500 · Cited by 1,557
A soft robot that navigates its environment through growth
Hawkes, E. W., Blumenschein, L. H., Greer, J. D., & Okamura, A. M. (2017) · Science Robotics · doi:10.1126/scirobotics.aan3028 · Cited by 968
Self-citationMotion planning with sequential convex optimization and convex collision checking
Schulman, J., Duan, Y., Ho, J., Lee, A., Awwal, I., Bradlow, H., Pan, J., Patil, S., Goldberg, K., & Abbeel, P. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364914528132 · Cited by 866
Mechanics of Precurved-Tube Continuum Robots
Webster, R. J., Romano, J. M., & Cowan, N. J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2006868 · Cited by 485
Self-citationSoft Robots Modeling: A Structured Overview
Armanini, C., Boyer, F., Mathew, A. T., Duriez, C., & Renda, F. (2023) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3231360 · Cited by 336
Medical Robotics and Computer-Integrated Surgery
Taylor, R. H., Menciassi, A., Fichtinger, G., Fiorini, P., & Dario, P. (2016) · Springer Handbooks · doi:10.1007/978-3-319-32552-1_63 · Cited by 325
Mechanics of Flexible Needles Robotically Steered through Soft Tissue
Misra, S., Reed, K. B., Schafer, B. W., Ramesh, K. T., & Okamura, A. M. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910369714 · Cited by 314
Self-citationThree-Dimensional Needle Shape Reconstruction Using an Array of Fiber Bragg Grating Sensors
Roesthuis, R. J., Kemp, M., van den Dobbelsteen, J. J., & Misra, S. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2269836 · Cited by 281
Challenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Stiffness Control of Surgical Continuum Manipulators
Mahvash, M., & Dupont, P. E. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2105410 · Cited by 265
The Stochastic Motion Roadmap: A Sampling Framework for Planning with Markov Motion Uncertainty
Alterovitz, R., Simeon, T., & Goldberg, K. (2007) · Robotics: Science and Systems III · doi:10.15607/rss.2007.iii.030 · Cited by 232
“When restricted to motion in a plane, the bevel direction can be set to point left (b = 0) or right (b = 1) [36].”
BackgroundInfluentialEquilibrium Conformations of Concentric-tube Continuum Robots
Rucker, D. C., Webster, R. J., Chirikjian, G. S., & Cowan, N. J. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910367543 · Cited by 217
“Experiments demonstrate that this framework is more descriptive of physical prototype behavior than previous models it reduces model prediction error by 82% over the calibrated bending-only model, and”
BackgroundMethodResultInfluentialSelf-citationModel-Free Control for Continuum Robots Based on an Adaptive Kalman Filter
Li, M., Kang, R., Branson, D. T., & Dai, J. S. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2775663 · Cited by 195
Dynamics of Continuum and Soft Robots: A Strain Parameterization Based Approach
Boyer, F., Lebastard, V., Candelier, F., & Renda, F. (2021) · IEEE Transactions on Robotics · doi:10.1109/tro.2020.3036618 · Cited by 195
“Finally, for specific technological systems as those recently developed for soft robotics and medical needles [6],[12], the right-hand side of (26) remains valid, whereas the modeling effort is confined to the calculation of Λad in Qad.”
Motion Planning Under Uncertainty for Image-guided Medical Needle Steering
Alterovitz, R., Branicky, M., & Goldberg, K. (2008) · The International Journal of Robotics Research · doi:10.1177/0278364908097661 · Cited by 189
“When inserted, the asymmetric force applied by the bevel causes the needle to bend and follow a curved path through the tissue [56].”
BackgroundInfluentialKnotting/unknotting manipulation of deformable linear objects
Wakamatsu, H., Arai, E., & Hirai, S. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906064819 · Cited by 132
Alambeigi, F., Aghajani Pedram, S., Speyer, J. L., Rosen, J., Iordachita, I., Taylor, R. H., & Armand, M. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2946726 · Cited by 48
“, [3], [8]–[12]).”
Metadata
- Authors
- Webster, R. J., Kim, J. S., Cowan, N. J., Chirikjian, G. S., & Okamura, A. M.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2006-05
- Volume
- 25
- Issue
- 5-6
- Pages
- 509-525
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2107550832
- Cited by
- 633
- References
- 20
- FWCI
- 19.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.