A biologically inspired soft exosuit for walking assistance
The DOI matches its Crossref record; 65 of the 66 references it cites were found in a registry or an index.
Abstract
We present the design and evaluation of a multi-articular soft exosuit that is portable, fully autonomous, and provides assistive torques to the wearer at the ankle and hip during walking. Traditional rigid exoskeletons can be challenging to perfectly align with a wearer’s biological joints and can have large inertias, which can lead to the wearer altering their natural motion patterns. Exosuits, in comparison, use textiles to create tensile forces over the body in parallel with the muscles, enabling them to be light and not restrict the wearer’s kinematics. We describe the biologically inspired design and function of our exosuit, including a simplified model of the suit’s architecture and its interaction with the body. A key feature of the exosuit is that it can generate forces passively due to the body’s motion, similar to the body’s ligaments and tendons. These passively generated forces can be supplemented by actively contracting Bowden cables using geared electric motors, to create peak forces in the suit of up to 200 N. We define the suit–human series stiffness as an important parameter in the design of the exosuit and measure it on several subjects, and we perform human subjects testing to determine the biomechanical and physiological effects of the suit. Results from a five-subject study showed a minimal effect on gait kinematics and an average best-case metabolic reduction of 6.4%, comparing suit worn unpowered versus powered, during loaded walking with 34.6 kg of carried mass including the exosuit and actuators (2.0 kg on both legs, 10.1 kg total).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Soft-robotic systems therefore show great potential in medical and wearable applications.[462–464]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [462]
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
McGeer, T. (1990) · The International Journal of Robotics Research · doi:10.1177/027836499000900206 · Cited by 3,359 · cited 2×
“Finally, both humans and passive dynamic walkers use small amounts of input energy at specific times in the gait cycle during walking (McGeer, 1990; Collins et al., 2005).”
BackgroundEfficient Bipedal Robots Based on Passive-Dynamic Walkers
Collins, S., Ruina, A., Tedrake, R., & Wisse, M. (2005) · Science · doi:10.1126/science.1107799 · Cited by 1,873 · cited 1×
“Finally, both humans and passive dynamic walkers use small amounts of input energy at specific times in the gait cycle during walking (McGeer, 1990; Collins et al., 2005).”
BackgroundLower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327 · cited 1×
“Other systems were designed to augment healthy individuals, but these could also be used with impaired individuals for rehabilitation or assistance purposes, perhaps with modifications to their control strategies (Dollar and Herr, 2008; Herr, 2009).”
BackgroundDesign and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280 · cited 1×
“Some exoskeletons are stationary, mounted above treadmills and used to provide gait retraining or rehabilitation for those with disabilities or injuries (Jezernik et al., 2003; Banala et al., 2007; Veneman et al., 2007).”
BackgroundGait Analysis: Normal and Pathological Function
Grant, A. D. (2010) · JAMA · doi:10.1001/jama.2010.1210 · Cited by 1,123
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958 · cited 1×
“Devices in the former category are intended to be used by paralyzed individuals, enabling them to walk when they were previously unable to do so (Ackerman, 2010; Neuhaus et al., 2011; Esquenazi et al., 2012).”
BackgroundDonelan, J. M., Kram, R., & Kuo, A. D. (2002) · Journal of Experimental Biology · doi:10.1242/jeb.205.23.3717 · Cited by 670
The Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603 · cited 2×
“The distribution of the mass is important as prior biomechanics studies have identified that mass at the foot during walking has a metabolic cost of 7.5% to 8.5% per kg of total added mass, as compared to 1% to 2% for mass at the waist (Rose and Gamble, 2006; Browning et al., 2007).”
BackgroundInfluentialDerivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
Research works printed but not linked: 7
- Brockway JM, 1987, Human Nutrition. Clinical Nutrition, 41, 463
- In H, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Neuhaus PD, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Quintero H, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Rose J, 2006, Human Walking
- 10.1155/2009/829219 · doi:10.1155/2009/829219
- Vanoglio F, 2013, XIII congress of Italian Society of Neurorehabilitation
Cited by
Items 201–300 of 460
Lee, H. D., Park, H., Hong, D. H., & Kang, T. H. (2022) · Actuators · doi:10.3390/act11060166 · Cited by 15
“However, an exoskeleton has a lower degree of freedom (DOF) than the body of the wearer, while the mass and inertia of the mechanism may affect one’s balance when walking [6,7].”
BackgroundA Biologically-inspired Soft Exosuit for Knee Extension Assistance during Stair Ascent
Huang, G. S., Ma, L., Zhu, H., Qian, Y., Leng, Y., & Fu, C. (2020) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm49381.2020.9195271 · Cited by 15
“The reason may be that during level walking the biological knee moment is very small, approximating 20% of the ankle moment, or 40% of the hip moment [11].”
BackgroundMethodEffects of User Intent Changes on Onboard Sensor Measurements During Exoskeleton-Assisted Walking
Higgins, T. M., Schmiedeler, J. P., & Wensing, P. M. (2020) · IEEE Access · doi:10.1109/access.2020.3044255 · Cited by 15
“Force control is common in soft exoskeletons aimed at reducing the metabolic cost of walking [7]–[9] by optimizing the propulsive force timing and amplitude to match the user’s joint-level intentions for a goal-level speed.”
BackgroundA mechatronic leg replica to benchmark human–exoskeleton physical interactions
Dežman, M., Massardi, S., Pinto-Fernández, D., Grosu, V., Rodriguez‐Guerrero, C., Babič, J., & Torricelli, D. (2023) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/accda8 · Cited by 14
“Power transmission issues are related to several factors such as kinematic compatibility, resulting in joint misalignments, and interface design, which affects contact stiffness and relative motion between the limb and the robot [8, 10].”
BackgroundMahdian, Z. S., Wang, H., Refai, M. I. M., Durandau, G., Sartori, M., & MacLean, M. K. (2023) · Journal of Applied Biomechanics · doi:10.1123/jab.2023-0046 · Cited by 15
A hybrid ankle-foot orthosis with soft pneumatic actuation
Marconi, G., Gopalai, A. A., & Chauhan, S. (2024) · Mechatronics · doi:10.1016/j.mechatronics.2024.103171 · Cited by 13
Guo, W., Katiyar, S. A., Davis, S., & Nefti‐Meziani, S. (2025) · Machines · doi:10.3390/machines13111020 · Cited by 15
Design of a Series Elastic Tendon Actuator Based on Gait Analysis for a Walking Assistance Exosuit
Lee, H. D., Moon, J.-I., & Kang, T. H. (2019) · International Journal of Control Automation and Systems · doi:10.1007/s12555-018-0492-0 · Cited by 13
Soft robot review: Actuation and application
Liu, Y. (2022) · International Conference on Electronics and Devices, Computational Science (ICEDCS) · doi:10.1109/icedcs57360.2022.00012 · Cited by 13
Active knee joint exoskeleton for stair ascent augmentation
Zhang, Z., Fan, J., Jin, H., Zheng, T., Zhao, S., Ma, S., Zhao, J., & Zhu, Y. (2020) · Science China Information Sciences · doi:10.1007/s11432-018-9767-6 · Cited by 13
Learning-Based Repetitive Control of a Bowden-Cable-Actuated Exoskeleton with Frictional Hysteresis
Shi, Y., Guo, M., Hui, C., Li, S., Ji, X., Yang, Y., Luo, X., & Xia, D. (2022) · Micromachines · doi:10.3390/mi13101674 · Cited by 13
“proposed a wearable soft exosuit driven by Bowden cables, where the motion of geared motors was transmitted by the relative movement between the inner cable and outer sheath to individual exoskeleton joints [14].”
BackgroundLi, L., Ji, J., Ren, H. J., Gao, L., Li, X., Li, N., Zhang, S., Tang, K., Li, Z., Ren, W., et al. (2026) · The Innovation · doi:10.1016/j.xinn.2026.101307 · Cited by 25
Basla, C., Mariani, G., Wolf, P., Riener, R., & van Hedel, H. J. A. (2024) · Frontiers in Robotics and AI · doi:10.3389/frobt.2024.1335733 · Cited by 12
Sadeghi, A., Mondini, A., & Mazzolai, B. (2018) · Biosystems & biorobotics · doi:10.1007/978-3-030-01887-0_10 · Cited by 12
Assistive Force of a Belt-type Hip Assist Suit for Lifting the Swing Leg during Walking
Guo, S., Xiang, Q., Hashimoto, K., & Jin, S. (2020) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra40945.2020.9196788 · Cited by 12
Qiu, S., Guo, W. P., Zha, F., Deng, J., & Wang, X. (2021) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2021.672582 · Cited by 13
“To avoid the above drawbacks of biosignals, some non-biosignal based active assistance control strategies have been proposed, such as gait phase based control (Asbeck et al., 2015), integral admittance shaping control (Nagarajan et al.”
MethodSy, L. W., Hoang, T. T., Bussu, M., Thai, M. T., Phan, P. T., Low, H., Tsai, D., Brodie, M. A. D., Lovell, N. H., & Do, T. N. (2021) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft51838.2021.9479333 · Cited by 12
An inertial sensing mechanism for measuring gait parameters and gait energy expenditure
Vidyarani, K. R., Talasila, V., Megharjun, N., Supriya, M. S., Prasad, K. J. R., & Prashanth, G. R. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103056 · Cited by 11
Bermejo-García, J., Jorge, D., Romero, F., & Sánchez, F. J. A. (2023) · Mechanics Based Design of Structures and Machines · doi:10.1080/15397734.2023.2248247 · Cited by 11
“4, from the hip joint center to simulate the placement of the cable over the backpack where the actuators would be located (Asbeck, De Rossi, et al. 2015; Jorge et al. 2022b).”
A cable-based series elastic actuator with conduit sensor for wearable exoskeletons
Blumenschein, L. H., McDonald, C. G., & O’Malley, M. K. (2017) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2017.7989790 · Cited by 11
“Though this design decision can limit their overall output strength and speed, the soft exoskeleton concept has been successfully realized as robotic gloves [2]–[5], soft orthoses [6], lower limb devices for metabolic reduction [7], [8] and rehabilitation [9].”
BackgroundLower Extremity Exoskeleton for Stair Climbing Augmentation
Zhang, Z., Zhu, Y., Zheng, T., Zhao, S., Ma, S., Fan, J., & Zhao, J. (2018) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm.2018.8610718 · Cited by 11
“From[10][11], it can be concluded that when level walking, the hip and ankle joints act as driving sources and the knee joint mainly dissipate energy.”
BackgroundUsing force-displacement relations to obtain actuation parameters from artificial muscles
Spinks, G. M., Bakarich, S. E., Aziz, S., Salahuddin, B., & Xin, H. (2019) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2019.03.012 · Cited by 11
Freitas, B., da Silva, M. R., Carvalho, Ó. S. N., Renjewski, D., Fonseca, J. C., Flores, P., & Espregueira‐Mendes, J. (2019) · IEEE Portuguese Meeting on Bioengineering · doi:10.1109/enbeng.2019.8692551 · Cited by 11
“On the other hand, the Wyss Institute developed a soft exoskeleton with the advantage of not including rigid framing elements that could interfere in the comfort of the patient [4].”
A real-time walking pattern recognition method for soft knee power assist wear
Wang, W., Zhang, L., Liu, J., Zhang, B., & Huang, Q. (2020) · International Journal of Advanced Robotic Systems · doi:10.1177/1729881420925291 · Cited by 12
Running Motion Assistance Using a Soft Gait-Assistive Suit and Its Experimental Validation
Miyazaki, T., Kawase, T., Kanno, T., Sogabe, M., Nakajima, Y., & Kawashima, K. (2021) · IEEE Access · doi:10.1109/access.2021.3093209 · Cited by 11
Park, E. J., Kang, J., Su, H., Stegall, P., Miranda, D. L., Hsu, W., Karabas, M., Phipps, N. S., Agrawal, S. K., Goldfield, E. C., et al. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009269 · Cited by 11
“For patients with partial gait impairment, such as stroke survivors, recent developments include textile-based, Bowden-cable actuated soft exosuits [13]–[15] which provide only moderate levels of assistance compared to their rigid counterparts, but are much lighter, lower-profile and wearable.”
BackgroundSelf-citationConcept and Prototype Design of a Soft Knee Exoskeleton with Continuum Structure (SoftKEX)
Zhou, Z., Liu, X., & Wang, Q. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-27526-6_7 · Cited by 11
A Novel Control Method of A Soft Exosuit with Plantar Pressure Sensors
Hu, H., Fang, K., Guan, H., Wu, X., & Chen, C. (2019) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm.2019.8833934 · Cited by 10
“Cable-driven system is used in soft exosuit to transmit force through the cables [11] [12] [13].”
MethodLi, N., Yang, T. Y., Yang, Y., Chen, W., Yu, P., Zhang, C., Xi, N., Zhao, Y., & Wang, W. (2022) · Journal of Bionic Engineering · doi:10.1007/s42235-022-00299-6 · Cited by 10
Zhou, Z., Wang, Z., & Wang, Q. (2020) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim43001.2020.9159027 · Cited by 10
“Different from that, soft exoskeletons [4], [5], use cables anchored to human body by soft fabric to transfer power.”
BackgroundMechanical Design and Preliminary Performance Evaluation of a Passive Arm-support Exoskeleton
Du, Z., Yan, Z., Huang, T., Zhang, Z., Zhang, Z., Bai, O., Huang, Q., & Han, B. (2020) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros45743.2020.9341290 · Cited by 10
“Establishment of the shoulder Model Exoskeletons can provide resistance to movement if the joints of the system are misaligned with the wearer’s joints[20,21].”
BackgroundDesign of a Soft Wearable Device for Hip and Knee Extension Assistance
Park, H., Lan, J., Zhang, J., Chen, K., & Fu, C. (2019) · International Conference on Control, Automation and Robotics (ICCAR) · doi:10.1109/iccar.2019.8813492 · Cited by 10
“In order to assist human walking, several soft wearable devices have been proposed [3-5], these devices removed rigid links which are parts of traditional exoskeletons [6-8].”
BackgroundCharacterization and Lubrication of Tube-Guided Shape-Memory Alloy Actuators for Smart Textiles
Helps, T., Vivek, A., & Rossiter, J. M. (2019) · Robotics · doi:10.3390/robotics8040094 · Cited by 12
McGrath, R., Bodt, B., & Sergi, F. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3039962 · Cited by 10
“stance, can reduce metabolic cost and muscle activation, while subjects walked at fixed GS [14]–[16].”
BackgroundWang, X., Guo, S. L., Song, M., & Wang, P. (2021) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm52023.2021.9536153 · Cited by 10
Development and Testing of Novel Soft Sleeve Actuators
Abboodi, M., & Doumit, M. (2024) · IEEE Access · doi:10.1109/access.2024.3376407 · Cited by 9
“The integration of bellows within textiles, as explored in [4], typically results in a considerable dissipation of actuation energy through the stretching of interfacing layers, thereby compromising their stability and activity.”
BackgroundInfluentialGong, S., Ye, X., Wang, Y., Li, W., Zhang, W., & Shao, L. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116669 · Cited by 9
Nie, J., Sugahara, Y., & Takeda, Y. (2022) · IEEE International Conference on Human-Machine Systems (ICHMS) · doi:10.1109/ichms56717.2022.9980804 · Cited by 9
“Lower limb exoskeleton or exosuit is a possible solution, but it directly adds additional forces/torques to human joints(such as ankle and hip) [6],”
BackgroundDouble Air Chambers Pneumatic Artificial Muscle and Non-Hysteresis Position Control
Saito, N., SATOH, T., & Saga, N. (2024) · Actuators · doi:10.3390/act13080282 · Cited by 9
“In recent years, machines that include automatic controls, such as robots that coexist with humans [1–4] and wearable robotics [5–10], have come to operate in environments that are close to or involve contact with humans.”
BackgroundLeng, Y., Huang, G. S., Lang, M., Qian, Y., Chen, X., Zhang, K., & Fu, C. (2021) · International Conference on Mechatronics and Machine Vision in Practice (M2VIP) · doi:10.1109/m2vip49856.2021.9665002 · Cited by 9
“Shear forces against the skin will cause slipping of the exosuit and chafing if the friction force with the skin is exceeded [20].”
BackgroundA Soft Wearable Robotic Suit for Ankle and Hip Assistance: a Preliminary Study
Jin, S., Guo, S., Hashimoto, K., Xiong, X., & Yamamoto, M. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512599 · Cited by 10
Human Musculoskeletal and Energetic Adaptations to Unilateral Robotic Knee Gait Assistance
Baček, T., Moltedo, M., Serrien, B., Langlois, K. P., Vanderborght, B., Lefeber, D., & Rodriguez‐Guerrero, C. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3114737 · Cited by 11
“The adaptations in healthy persons during pHRI while walking have been studied in the case of the ankle [7], [10]–[15], hip [16], [17], and the hip-ankle multi-joint configuration [18]–[20], but are missing in the case of a knee joint.”
BackgroundSui, D., Chang, B., Hidayah, R., Zhu, Y., & Agrawal, S. K. (2021) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48506.2021.9560775 · Cited by 9
“Their designs have targeted whole body [1], upper/lower limbs [2]–[4] and single joint [5].”
BackgroundDesign Methodology for Soft Wearable Devices—The MOSAR Case
Dávila-Vilchis, J.-M., Avilés, L. A. Z., Ávila-Vilchis, J. C., & Vilchis-González, A. H. (2019) · Applied Sciences · doi:10.3390/app9224727 · Cited by 10
“For example, Soft Exo-suits have been proposed for walking tasks [4,5] and knee rehabilitation [6,7].”
BackgroundHan, M. F., Shi, B., Wang, S., Li, T., Feng, J., & Ma, T. (2020) · Mathematical Problems in Engineering · doi:10.1155/2020/5074858 · Cited by 9
“[15, 16] proposed a multiarticular soft exosuit and a method for evaluating the effect of power assistance.”
MethodImplementation of a passive bi-articular ankle–knee exoskeleton during maximal squat jumping
Wade, L., Lichtwark, G. A., & Farris, D. J. (2024) · Royal Society Open Science · doi:10.1098/rsos.240390 · Cited by 8
Structure design and mechanical analysis of a hybrid rigid-soft knee exoskeleton based on curve beam
Jin, S., Ge, W., & Chen, N. (2024) · Acta Mechanica Sinica · doi:10.1007/s10409-024-24052-x · Cited by 8
Wang, Y., Li, J., Liang, P., & Ye, R. (2025) · Journal of Mechanisms and Robotics · doi:10.1115/1.4067874 · Cited by 8
Minimalistic Soft Exosuit for Assisting the Shoulder via Biomechanics-Aware Optimization
Joshi, S., Beck, I., Seth, A., & Santina, C. D. (2022) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids53995.2022.10000128 · Cited by 8
“the user in predefined motions of the ankle [11], hip [12],”
BackgroundSoft Scissor: A Cartilage-Inspired, Pneumatic Artificial Muscle for Wearable Devices
Rahman, N., Diteesawat, R. S., Hoh, S., Morris, L., Turton, A., Cramp, M., & Rossiter, J. M. (2025) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2025.3527307 · Cited by 8
“The exploration of soft, wearable powered devices for use in rehabilitative and assistive applications has been of particular interest in the recent decade, resulting in various prototypes [7], [8], [9] and even a commercially available product, the ReStore exosuit [10].”
Jung, E. A., Ly, V. T., Buderi, A., Appleton, E., & Teodorescu, M. (2019) · IEEE International Conference on Robotic Computing (IRC) · doi:10.1109/irc.2019.00053 · Cited by 8
“The former is usually a system that consists of springs, or dampeners in order to disperse strain [4], [5] while powered systems require electric impulses in order to create movement [3], [6].”
BackgroundYe, X., Chen, C., Shi, Y., Chen, L., Wang, Z., Zhang, Z., Liu, Y., & Wu, X. (2021) · Micromachines · doi:10.3390/mi12101150 · Cited by 11
Exo Supportive Devices: Summary of Technical Aspects
André, A., & Martins, P. (2023) · Bioengineering · doi:10.3390/bioengineering10111328 · Cited by 5
“In general, these materials enable movement smoothness [80], comfort, portability, flexibility, lightweight (low density) [68,73], adaptation to bioorganisms [66] and even the ability to emulate biological muscles [77].”
BackgroundA Soft Robotic Wrist Orthosis Using Textile Pneumatic Actuators For Passive Rehabilitation
Sepehri, A., Ward, S. R., Tolley, M. T., & Morimoto, T. K. (2024) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft60065.2024.10521992 · Cited by 8
“We determined two further requirements to ensure comfort when donned: (4) Minimize shearing and relative motion between the suit and human, and (5) Maximize suit-skin contact area to minimize normal pressure and maximize interface stiffness [15].”
BackgroundA Unified Active Assistance Control Framework of Hip Exoskeleton for Walking and Balance Assistance
Qiu, S., Guo, W. P., Wang, P., Chen, F., Zha, F., Wang, X., & Deng, J. (2019) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros40897.2019.8968055 · Cited by 8
“The human intention based AWAC include the electromyography (EMG) feedback control [10], the gait-phase-based control [11] and the adaptive oscillator based control [12].”
MethodWang, Z., Huang, G., Liu, B., Zhou, Z., Liang, B., Liu, Y., & Xie, L. (2021) · Journal of Biomechanical Engineering · doi:10.1115/1.4051434 · Cited by 8
A portable exotendon assisting hip and knee joints reduces muscular burden during walking
Cheng, L., Xiong, C., Chen, W., Liang, J., Huang, B., & Xu, X. (2021) · Royal Society Open Science · doi:10.1098/rsos.211266 · Cited by 8
“Many previous studies also reported alterations in kinematics more or less [6,25,31,33,37,44].”
BackgroundGollob, S. D., Mendoza, M. J., Koo, B. H., Centeno, E., Vela, E. A., & Roche, E. T. (2023) · Frontiers in Robotics and AI · doi:10.3389/frobt.2023.1190387 · Cited by 8
A Phase-Invariant Linear Torque-Angle-Velocity Relation Hidden in Human Walking Data
Altinkaynak, E. S., & Braun, D. J. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2899970 · Cited by 9
Clinical Challenges in Soft Robotics
Malappuram, K. M., Chatterjee, K., Homer‐Vanniasinkam, S., & Nain, A. (2025) · Advanced Robotics Research · doi:10.1002/adrr.202400018 · Cited by 7
Modulating Multiarticular Energy during Human Walking and Running with an Unpowered Exoskeleton
Zhou, T., Zhou, Z., Zhang, H., & Chen, W. (2022) · Sensors · doi:10.3390/s22218539 · Cited by 7
“The waist frame was designed to attach to the human body with high stiffness points, which was reported in [8].”
BackgroundForce Tracking Control With Adaptive Stiffness and Iterative Position of Hip-Assistive Soft Exosuits
Chen, Q., Guo, S., & Zhang, D. (2023) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2023.3339779 · Cited by 7
“The human-exosuit system is nonlinear and hysteretic, and its stiffness is relatively low [24].”
BackgroundA Novel Soft Exosuit Based on Biomechanical Analysis for Assisting Lower Extremity
Liu, Y., Chen, C., Lu, J., Liu, Y., Zhang, Y., & Wang, Z. (2021) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom49281.2021.9399024 · Cited by 7
“Rigid structure restricted the freedom of human movements and affected wearing comfort [7], [8].”
BackgroundLoad Carriage During Walking Increases Dynamic Stiffness at Distal Lower Limb Joints
Santos, T. R. T., Fonseca, S. T., Araújo, V. L., Lee, S., Saucedo, F., Allen, S. P., Siviy, C., Souza, T. R., Walsh, C. J., & Holt, K. G. (2021) · Journal of Applied Biomechanics · doi:10.1123/jab.2020-0346 · Cited by 7
Self-citationJung, E. A., Ly, V. T., Cheney, C., Cessna, N., Ngo, M. L., Castro, D., & Teodorescu, M. (2021) · Applied Sciences · doi:10.3390/app11199351 · Cited by 7
Reaction moments matter when designing lower-extremity robots for tripping recovery
Jabeen, S., Baines, P. M., Harlaar, J., Vallery, H., & Berry, A. (2023) · PLoS ONE · doi:10.1371/journal.pone.0280158 · Cited by 7
“Internal reaction systems, are highly favoured in contexts where mobility is a priority and often take the form of wearables such as rigid exoskeletons (EksoNR [Ekso Bionics Inc, Richmond, USA], Indego [Parker Hannifin Corp, Macedonia, USA], ReWalk [ReWalk Robotics Inc, Marlborough, USA]) or compliant tendon-driven ex…”
BackgroundDurandau, G., Rampeltshammer, W. F., van der Kooij, H., & Sartori, M. (2020) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob49111.2020.9224365 · Cited by 7
“pre-determined gait phases [2] or online optimized joint torque patterns that minimize metabolic energy consumption [3].”
BackgroundThe development of posture supporting soft exosuit design for adolescent idiopathic scoliosis
ÇAKMAK, Ş., ÇEĞİNDİR, N., & Yılmaz, H. G. (2021) · International Journal of Clothing Science and Technology · doi:10.1108/ijcst-12-2020-0202 · Cited by 7
Electromagnetic Clutch-Based Ankle Exosuit for Assisting Stroke Survivors With Different Body Sizes
Yin, S., Shi, B., Liu, G., Wang, J., & Zhao, C. (2023) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2023.3286175 · Cited by 9
“Compared with other ankle rehabilitation robots [11], [12], [23], [24] (Table II), the form of a motor bilaterally assisting the ankle could effectively use electrical energy and reduces the weight of the device, and meet the need for abnormal gait correction for stroke survivors.”
BackgroundMethodInfluentialBiomechanical Analysis and Inertial Sensing of Ankle Joint While Stepping on an Unanticipated Bump
Miyatake, T., Lee, S., Galiana, I., Rossi, D. M., Siviy, C., Panizzolo, F. A., & Walsh, C. J. (2016) · Biosystems & biorobotics · doi:10.1007/978-3-319-46532-6_56 · Cited by 7
Self-citationConcept and Prototype Design of an Underwater Soft Exoskeleton
Zhang, Z., Zhou, Z., Zheng, E., Zhou, Y., Zhang, S.-C., Mai, J., & Wang, Q. (2018) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs.2018.8612270 · Cited by 7
“In a series of studies [12]– [15], researchers of the Harvard Bionic Design Laboratory developed a soft assistive device named Soft Exosuit.”
BackgroundHybrid Soft-Rigid Elbow Exosuit: Theory, Mechatronic Design, and Experimental Assessment
Bonab, A. K., Camardella, C., Frisoli, A., & Chiaradia, D. (2026) · IEEE Transactions on Robotics · doi:10.1109/tro.2026.3653884 · Cited by 6
Probabilistic Locomotion Mode Recognition with Wearable Sensors
Martínez-Hernández, U., Mahmood, I., & Dehghani-Sanij, A. A. (2016) · Biosystems & biorobotics · doi:10.1007/978-3-319-46669-9_168 · Cited by 6
“Wearable soft robotics has shown great technological advances in recent years, specially on soft actuators and lowlevel controllers to assist humans in walking activities [1].”
BackgroundHuman Factor Engineering Research for Rehabilitation Robots: A Systematic Review
Song, D., Liu, S., Gao, Y., & Huang, Y. (2023) · Computational Intelligence and Neuroscience · doi:10.1155/2023/2052231 · Cited by 6
Mechatronic Design of a Shank-Free Bilateral Exoskeleton for Loaded Walking
Zhou, Z., Xu, M. Y., Wang, Z., Gao, H., Mai, J., & Wang, Q. (2024) · IEEE International Conference on Advanced Intelligent Mechatronics (AIM) · doi:10.1109/aim55361.2024.10637088 · Cited by 6
“Asbeck et al. presented a multi-articular soft exoskeleton with a total weight of 10.1 kg to provide assistance for loaded walking [13].”
BackgroundMethodInfluentialA Control Method With Terrain Classification and Recognition for Lower Limb Soft Exosuit
Ni, J., Chen, C., Wang, Z., Liu, Y., Wu, X., & Liu, Y. (2021) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom49281.2021.9399014 · Cited by 6
“Therefore, the soft wearable robot [6], [7] composed of soft textiles, soft sensors, and soft actuators have more advantages because of its lightweight, more comfortable, and convenient wearing, and the auxiliary force without interfering with a normal gait.”
BackgroundHarnessing Energy of a Treadmill for Push-Off Assistance During Walking: In-Silico Feasibility Study
Tomc, M., & Matjačić, Z. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.832087 · Cited by 6
“, 2015) as well as soft textile-based interfaces (Asbeck et al., 2015; Awad et al., 2020a) have been proposed.”
BackgroundWearable ankle assistance robot for a human walking with different loads
Li, J., Yang, K., & Yang, D. (2023) · Mechanical sciences · doi:10.5194/ms-14-429-2023 · Cited by 7
“When a load of 22.5 kg is added, the net metabolic cost is reduced by 10 1 6 8 % Asbeck et al. (2015) developed a − 1 provide mechanical power for an ankle, with an inertial measurement unit (IMU) located in the front of the lower leg to judge the gait phase of a human.”
BackgroundInfluentialWang, Z., Song, W., Bian, W., Li, Z., Jia, Z., & Yu, X. (2024) · Journal of Mechanisms and Robotics · doi:10.1115/1.4064636 · Cited by 6
Design, modeling and optimization of a high torque asymmetric dual chamber soft actuator
Wang, Y., Yuan, S., Hou, M., Cui, X., Zhou, S., & Fei, Y. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115635 · Cited by 6
Mišković, L., Dežman, M., & Petrič, T. (2021) · International Conference on Advanced Robotics (ICAR) · doi:10.1109/icar53236.2021.9659353 · Cited by 6
Volume Transfer: A New Design Concept for Fabric‐Based Pneumatic Exosuits
Liu, C., Yang, D., Chen, J., Dai, Y., Jiang, L., & Liu, H. (2024) · Advanced Intelligent Systems · doi:10.1002/aisy.202400039 · Cited by 6
Grimmer, M., Quinlivan, B., Lee, S., Malcolm, P., Rossi, D. M., Siviy, C., & Walsh, C. J. (2016) · Biosystems & biorobotics · doi:10.1007/978-3-319-46532-6_55 · Cited by 6
“2 (a) and (b), using an approach similar to [8], the AMIC used the suit-human series stiffness of the exosuit [5] and averaged ankle kinematics and kinetics data to identify a position trajectory that would produce biologically relevant assistive ankle moments during push-off.”
BackgroundMethodSelf-citationA simple 2D straight-leg passive dynamic walking model without foot-scuffing problem
Li, Q., Liu, G., Tang, J., & Zhang, J. (2016) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2016.7759757 · Cited by 6
“Now, PDW has been extensively used to reveal the principles underlying bipedal locomotion and to design more efficient walking robots, as well as more suitable exoskeletons, exosuits and prostheses [5], [6].”
BackgroundA Simulation-Based Study on a Clutch-Spring Mechanism Reducing Human Walking Metabolic Cost
Shen, Z., Sam, S., Allison, G. T., & Cui, L. (2017) · International Journal of Mechanical Engineering and Robotics Research · doi:10.18178/ijmerr.7.1.55-60 · Cited by 6
“[5] A. T. Asbeck, S. M. De Rossi, K. G. Holt, and C. J. Walsh, "A biologically inspired soft exosuit for walking assistance," The International Journal of Robotics Research, p. 0278364914562476, 2015.”
BackgroundInfluentialDesign of a Variable Stiffness Wrist Brace With an Origami Structural Element
de Oliveira, M. B., Liu, C., Zhao, M., & Felton, S. M. (2018) · ASME Conference on Smart Materials, Adaptive Structures and Intelligent Systems (SMASIS) · doi:10.1115/smasis2018-8049 · Cited by 6
Characterizing Intent Changes in Exoskeleton-Assisted Walking Through Onboard Sensors
Higgins, T. M., Schmiedeler, J. P., & Wensing, P. M. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779503 · Cited by 6
“Soft exoskeletons, or exosuits, have successfully utilized kinematic and gait event-related cues to coordinate the exoskeleton with human motion, achieving reductions in the metabolic cost of walking [1], [2].”
BackgroundA Biologically Inspired Lower Limb Cable Driven Exoskeleton
Yan, L., Ren, L., & Wei, G. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-13841-6_58 · Cited by 5
Chen, Q., Wang, J., Xiang, Q., & Guo, S. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3408308 · Cited by 5
“The main composition of these exosuits is soft textile materials, endowing them with qualities such as lightweight structure, minimal inertia, and ease of putting on and taking off [6].”
BackgroundFlexible Lower Limb Exoskeleton Robot for Rehabilitation Training of Children with Cerebral Palsy
Jiang, H., Zhou, X., Li, X., Chen, Z., Du, Q., & Xie, L. (2024) · Journal of Shanghai Jiaotong University (Science) · doi:10.1007/s12204-024-2760-x · Cited by 5
A Review: Developments in Hardware Systems of Active Ankle Orthoses
Gunaratne, P. N., & Tamura, H. (2024) · Sensors · doi:10.3390/s24248153 · Cited by 5
Simulating Physiological Discomfort of Exoskeletons Using Musculoskeletal Modelling
Shourijeh, M. S., Jung, M., Ko, S.-T., McGrath, M., Stech, N., & Damsgaard, M. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.06.301 · Cited by 5
Derammelaere, S., Copot, C., Haemers, M., Verbelen, F., Vervisch, B., Ionescu, C. M., & Stockman, K. (2018) · European Journal of Control · doi:10.1016/j.ejcon.2018.07.004 · Cited by 5
Design and Experimental Evaluation of Wearable Lower Extremity Exoskeleton with Gait Self-adaptivity
Wang, W., Zhang, L., Cai, K., Wang, Z., Zhang, B., & Huang, Q. (2019) · Robotica · doi:10.1017/s0263574719000663 · Cited by 5
“Trk = (Frf − Frs)a sin α − (Frf − Frs)a 2sin α cos α √ b2 − a2sin(2)α (7)”
BackgroundMulti-Gait Recognition for a Soft Ankle Exoskeleton with Limited Sensors
Ma, L., Leng, Y., Zhang, K., Qian, Y., & Fu, C. (2021) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm52023.2021.9536076 · Cited by 5
Fundamentals for the Design of Lower-Limb Exoskeletons
Ballén-Moreno, F., Gomez-Vargas, D., Langlois, K. P., Veneman, J. F., Cifuentes, C. A., & Múnera, M. (2021) · Springer eBooks · doi:10.1007/978-3-030-79630-3_3 · Cited by 6
Underwater Walking Using Soft Sensorless Gait Assistive Suit
Miyazaki, T., Suzuki, H., Morisaki, D., Kanno, T., Miyazaki, R., Kawase, T., Kawakami, Y., & Kawashima, K. (2019) · IEEE/SICE International Symposium on System Integration (SII) · doi:10.1109/sii.2019.8700346 · Cited by 5
“Various power assistive devices have been developed for various purposes [1][2]: in the welfare field for nursing [3], rehabilitation [4][5], and gait assistance [6][7][8]; in the industrial field for assembling and load-carrying [9][10]; and in the military field [11].”
BackgroundA Focused Review on Soft Robotic Exosuits for Sitting to Standing Transfers
Perera, C. K., Gopalai, A. A., Gouwanda, D., & Nurzaman, S. G. (2024) · Robotics Reports · doi:10.1089/rorep.2023.0025 · Cited by 9
Design and Overground Testing of a Portable Hip Exosuit for Enhancing Running Efficiency
Ciaramella, A., Bagneschi, T., Tricomi, E., Missiroli, F., Xiao-hui, Z., Frisoli, A., & Masia, L. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3503905 · Cited by 4
“Made from soft and adaptable materials, exo-suits align with the natural biomechanics of the human body, promoting comfort and wearability while still providing substantial locomotive assistance [11], [12].”
Stretchable Dielectric Fluid Pumps for Soft Fluid Power Systems
Sun, H., Zhang, L., Tao, C., Huang, Y., Liu, J., & Wang, J. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202500798 · Cited by 4
Metadata
- Authors
- Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J.
- Affiliations
- Harvard University (US)
- Harvard University, Cambridge, MA, USA
- Boston University (US)
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2015-03-16
- Volume
- 34
- Issue
- 6
- Pages
- 744-762
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2169410184
- Semantic Scholar
- 6f5747b1e1a55a0b7c475d4d70e90e139f3e74d5
- Cited by
- 450
- References
- 66
- Citations by year
- 2026: 34 · 2025: 43 · 2024: 38 · 2023: 40 · 2022: 39 · 2021: 63 · 2020: 48 · 2019: 43 · 2018: 42 · 2017: 33 · 2016: 21 · 2015: 4
- FWCI
- 16.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The International Journal of Robotics Research (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- soft exosuit, gait assistance, biologically inspired design, energy cost of walking, loaded walking, gait kinematics, wearable robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.