A biologically inspired soft exosuit for walking assistance
The DOI matches its Crossref record; 65 of the 66 references it cites were found in a registry or an index.
Abstract
We present the design and evaluation of a multi-articular soft exosuit that is portable, fully autonomous, and provides assistive torques to the wearer at the ankle and hip during walking. Traditional rigid exoskeletons can be challenging to perfectly align with a wearer’s biological joints and can have large inertias, which can lead to the wearer altering their natural motion patterns. Exosuits, in comparison, use textiles to create tensile forces over the body in parallel with the muscles, enabling them to be light and not restrict the wearer’s kinematics. We describe the biologically inspired design and function of our exosuit, including a simplified model of the suit’s architecture and its interaction with the body. A key feature of the exosuit is that it can generate forces passively due to the body’s motion, similar to the body’s ligaments and tendons. These passively generated forces can be supplemented by actively contracting Bowden cables using geared electric motors, to create peak forces in the suit of up to 200 N. We define the suit–human series stiffness as an important parameter in the design of the exosuit and measure it on several subjects, and we perform human subjects testing to determine the biomechanical and physiological effects of the suit. Results from a five-subject study showed a minimal effect on gait kinematics and an average best-case metabolic reduction of 6.4%, comparing suit worn unpowered versus powered, during loaded walking with 34.6 kg of carried mass including the exosuit and actuators (2.0 kg on both legs, 10.1 kg total).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Soft-robotic systems therefore show great potential in medical and wearable applications.[462–464]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [462]
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
McGeer, T. (1990) · The International Journal of Robotics Research · doi:10.1177/027836499000900206 · Cited by 3,359 · cited 2×
“Finally, both humans and passive dynamic walkers use small amounts of input energy at specific times in the gait cycle during walking (McGeer, 1990; Collins et al., 2005).”
BackgroundEfficient Bipedal Robots Based on Passive-Dynamic Walkers
Collins, S., Ruina, A., Tedrake, R., & Wisse, M. (2005) · Science · doi:10.1126/science.1107799 · Cited by 1,873 · cited 1×
“Finally, both humans and passive dynamic walkers use small amounts of input energy at specific times in the gait cycle during walking (McGeer, 1990; Collins et al., 2005).”
BackgroundLower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327 · cited 1×
“Other systems were designed to augment healthy individuals, but these could also be used with impaired individuals for rehabilitation or assistance purposes, perhaps with modifications to their control strategies (Dollar and Herr, 2008; Herr, 2009).”
BackgroundDesign and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280 · cited 1×
“Some exoskeletons are stationary, mounted above treadmills and used to provide gait retraining or rehabilitation for those with disabilities or injuries (Jezernik et al., 2003; Banala et al., 2007; Veneman et al., 2007).”
BackgroundGait Analysis: Normal and Pathological Function
Grant, A. D. (2010) · JAMA · doi:10.1001/jama.2010.1210 · Cited by 1,123
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958 · cited 1×
“Devices in the former category are intended to be used by paralyzed individuals, enabling them to walk when they were previously unable to do so (Ackerman, 2010; Neuhaus et al., 2011; Esquenazi et al., 2012).”
BackgroundDonelan, J. M., Kram, R., & Kuo, A. D. (2002) · Journal of Experimental Biology · doi:10.1242/jeb.205.23.3717 · Cited by 670
The Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603 · cited 2×
“The distribution of the mass is important as prior biomechanics studies have identified that mass at the foot during walking has a metabolic cost of 7.5% to 8.5% per kg of total added mass, as compared to 1% to 2% for mass at the waist (Rose and Gamble, 2006; Browning et al., 2007).”
BackgroundInfluentialDerivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
Research works printed but not linked: 7
- Brockway JM, 1987, Human Nutrition. Clinical Nutrition, 41, 463
- In H, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Neuhaus PD, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Quintero H, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Rose J, 2006, Human Walking
- 10.1155/2009/829219 · doi:10.1155/2009/829219
- Vanoglio F, 2013, XIII congress of Italian Society of Neurorehabilitation
Cited by
Items 301–400 of 460
Twisting Soft Sleeve Actuator: Design and Experimental Evaluation
Abboodi, M., & Doumit, M. (2025) · Electronics · doi:10.3390/electronics14204020 · Cited by 4
Lower limb active exoskeletons, exosuits, assistive devices and specifications: a scoping review
Trott, R. E., Kleinig, T. J., Hillier, S. L., Reynolds, K. J., & Hobbs, D. (2026) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-026-01955-2 · Cited by 4
“Two of these devices were soft exoskeletons [113, 114], which arguably could not support the user’s mass because its structural elements only act in tension.”
Design and transmission modeling of a soft elbow exosuit using double artificial tendon system
Shao, Z., Xi, W., & Wu, Q. (2022) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/09544062221129824 · Cited by 4
“Combining (4), (8), (9), (10), and (11), then the output angle can be obtained:”
BackgroundKinethreads: Soft Full-Body Haptic Exosuit using Low-Cost Motor-Pulley Mechanisms
Shen, V., & Harrison, C. (2025) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3746059.3747755 · Cited by 4
Key Technologies of Lower Limb Power-Assisted Exoskeleton Robots: A Review
Li, Y., Sun, H., Wang, C., Yang, Y. F., Fan, C., Zhang, Z., & Rui, Y. (2021) · International Conference on Control, Robotics and Cybernetics (CRC) · doi:10.1109/crc52766.2021.9620147 · Cited by 4
Kadokura, T., Miyazaki, T., Kawase, T., Sogabe, M., & Kawashima, K. (2023) · IEEE Access · doi:10.1109/access.2023.3265580 · Cited by 4
“[13], [14], [15] developed a soft exosuit which is light weight system driven by Bowden cables, and BLEEX (Berkeley Lower Extremity Exoskeleton) [24] was developed to improve carrying capacity and is driven”
BackgroundCooper, M., Canete, S., Eckert-Erdheim, A. M., Kimberley, A., Siviy, C., Baker, T. C., Ellis, T. D., Slade, P., & Walsh, C. J. (2024) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra57147.2024.10610736 · Cited by 4
“Research groups have presented overall power transmission efficiencies[17], [18] or bandwidth measurements [19] of various devices.”
BackgroundSelf-citationReducing Personalization Time and Energy Cost While Walking Outdoors with a Portable Exosuit
Nam, K., Sahoo, S., Kim, Y.-S., Go, D., Choo, J., Park, C., Yang, S., & Lee, G. (2025) · Advanced Robotics Research · doi:10.1002/adrr.202400027 · Cited by 4
Exoskeletons in the context of soldiers: Current status and future research trends
Ma, X., Lv, L., Liu, W., Niu, F., Wang, H., Wang, H., Zhao, L., Wang, Z., & Wang, Z. (2025) · Biomimetic Intelligence and Robotics · doi:10.1016/j.birob.2025.100254 · Cited by 4
Spine-like Joint Link Mechanism to Design Wearable Assistive Devices
Kim, J., Cho, J., Kim, J., Kim, J. T., Han, S.-C., Park, S., & Yoon, H. U. (2022) · Sensors · doi:10.3390/s22062314 · Cited by 4
“, exo-suit [10], exo-glove [29], soft power suit [30], inflatable soft wearable robot [31,32], and so on.”
BackgroundLiu, Y., Chen, C., Wang, Z., Tian, Y.-T., Wang, S., Xiao, Y., Yang, F., & Wu, X. (2024) · Bioengineering · doi:10.3390/bioengineering11020150 · Cited by 4
“The design concept of wearable robotic devices is to provide appropriate joint torques and timing based on biomechanical gait analysis [1,2].”
BackgroundCamp, A. S., Chapman, E., & Cienfuegos, P. J. (2019) · Sage Journals Data · doi:10.25384/sage.c.4656533 · Cited by 4
Shoe-Like Unpowered Exoskeleton With Energy Harvesting for Enhanced Walking Economy
Zhuang, J.-R., Chang, W.-T., & Lin, Y.-M. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3579359 · Cited by 3
“Users often object to their visibility and frequent battery replacements, which can disrupt both rehabilitation and daily activities [21], [22], [23].”
Esser, A., Basla, C., Wolf, P., & Riener, R. (2025) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr66766.2025.11063015 · Cited by 3
“This TDU supports multiple configurations, making it suitable for both upper and lower limb exosuits.”
Development of a string-driven walking assist device powered by upper body muscles
Ohashi, K., Akiyama, Y., Okamoto, S., & Yamada, Y. (2017) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2017.8122811 · Cited by 3
“The string-type wearable assist device applies torque to lower limb joints through the string fixed along the leg portion [11, 12].”
BackgroundAssistive Soft Exoskeletons with Pneumatic Artificial Muscles
Kurita, Y., Thakur, C., & Das, S. (2019) · Springer eBooks · doi:10.1007/978-3-030-34230-2_8 · Cited by 3
Wu, Q., Zhang, Y., & Chen, Y. (2021) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/09596518211014325 · Cited by 3
Terrain environment classification and recognition for soft lower-limb exosuit
Ni, J., Wang, Z., Li, F., Su, Z., Cao, W., & Chen, C. (2021) · IEEE International Conference on Real-time Computing and Robotics (RCAR) · doi:10.1109/rcar52367.2021.9517083 · Cited by 3
Towards open loop control of soft multistable grippers from energy-based modeling
Morgan, H., Osorio-Pinzon, J. C., & Arrieta, A. F. (2023) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft55895.2023.10121986 · Cited by 6
“robots several advantages over conventional hard robots, including facilitated human-machine interaction [5], [6], suitability for medical [7] and wearable devices [8], [9], and adaptability for gripping and manipulation [10]–[12].”
BackgroundSensing and Control Strategies for a Synergy-Based, Cable-Driven Exosuit via a Modular Test Bench
Jayakumar, A., Jorge, D., Bermejo-García, J., Agujetas, R., & Romero, F. (2023) · Sensors · doi:10.3390/s23104713 · Cited by 3
“This restriction was due to the inherent mechanical limitations of cable-driven exosuits, which were described by certain authors based on other state-of-the-art lower-limb, soft-assistive devices, as in [7].”
BackgroundInfluentialLabeling and Detection of Underwater Ankle Motions in Breaststroke With Wearable Sensors
Zhang, Z., Mai, J., & Wang, Q. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3324214 · Cited by 3
“Threshold-based methods using data such as plantar pressure, angle sensors, encoders, and strain gauges can detect the swing phase, standing phase, heel strike, toe off, maximum dorsiflexion of the ankle and other targets effectively [9], [10], [11].”
MethodDesign, modeling, and control of a novel soft-rigid knee joint robot for assisting motion
Li, Y., Wang, Y., Yuan, S., & Fei, Y. (2024) · Robotica · doi:10.1017/s0263574723001777 · Cited by 3
“Tendon-driven soft wearable robot uses soft materials as artificial tendons to assist human movements by stretching the user’s limbs [18].”
BackgroundMethodModeling, Optimization, and Musculoskeletal Simulation of Elbow-Wrist Exosuit
Bonab, A. K., Leonardis, D., Frisoli, A., & Chiaradia, D. (2023) · International Conference on Advanced Robotics (ICAR) · doi:10.1109/icar58858.2023.10406224 · Cited by 3
“The developed exosuits have demonstrated their capabilities in delivering positive assistance and support in targeted joints such as the shoulder [4]–[6], elbow [7]–[9], wrist [10], and hand [11] in the upper limb and the hip [12] and ankle [13], [14] in the lower limb.”
BackgroundOn-body textile hysteresis estimation for personalized physical human-robot interaction
McCann, C. M., Arnold, J., Lehmacher, C., Bertoldi, K., & Walsh, C. J. (2025) · The International Journal of Robotics Research · doi:10.1177/02783649251358840 · Cited by 3
“In some cases, these textiles serve as load bearing structures to transmit actuation forces to the wearer, even mimicking the underlying muscle and tendon load paths (Asbeck et al., 2015; Samper-Escudero et al., 2020).”
Self-citationHuman Activity Recognition with Discrete Cosine Transform in Lower Extremity Exoskeleton
Zhang, Y., An, H., Ma, H., Wei, Q., & Wang, J. (2018) · IEEE International Conference on Intelligence and Safety for Robotics (ISR) · doi:10.1109/iisr.2018.8535705 · Cited by 3
“For example, the soft exoskeletons designed by the Harvard Biodesign Lab are mainly used for walking on flat ground [1], [2] or individually for running scenarios [3]; in [4], the lower extremity exoskeleton was studied separately during the sit-to-stand movement.”
MethodAkiyama, Y., Kushida, R., Okamoto, S., & Yamada, Y. (2020) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2020.3016098 · Cited by 3
“The magnitude and timing of the assist were set by reference values used to assist devices and biomechanics [10], [18], [19].”
BackgroundMethodPresent and future of exoskeleton robots for rehabilitation: Actuation mechanisms review
Baek, H., Bijalwan, V., Khan, A. M., Jeong, M., Vellaiyan, V., & Kim, Y. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-21505-6.00005-0 · Cited by 2
Assist Control of Lifting Motion of Lumbar-Powered Exoskeleton Using IMU Sensors
Fujii, R., Takahashi, Y., Tsuichihara, S., & Yamada, T. (2025) · Journal of Advanced Computational Intelligence and Intelligent Informatics · doi:10.20965/jaciii.2025.p0559 · Cited by 2
Schiebl, J., Elsner, N., Birchinger, P., Aschenbrenner, J., Maufroy, C., Tröster, M., Schneider, U., & Bauernhansl, T. (2025) · Sensors · doi:10.3390/s25154605 · Cited by 2
“No additional studies on the upper arm were identified, whereas thigh and calf interfaces have been examined more frequently [32,42,43].”
InfluentialJammot, M., Esser, A., Wolf, P., Riener, R., & Basla, C. (2025) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra55743.2025.11127825 · Cited by 2
“To overcome the shortcomings in the responsiveness of Bowden cables, various control algorithms, such as position-control [21], adaptive controllers [17], or a backlash term capturing the actuator’s physical limitations [31] were proposed.”
InfluentialGuo, Y. G., Yang, X., Chen, Z., Yan, X., & Liu, F. (2025) · Robotica · doi:10.1017/s0263574725102142 · Cited by 2
“In this form, the direct-drive motors at the exoskeleton joints are replaced by distal cable-driven motors, and components with a relatively large weight in the exoskeleton system, such as motors and power supplies, are placed in a backpack to reduce the weight and inertia on the user’s limbs [11].”
Design, Control, and Evaluation of a Multijoint Lower Limb Soft Exosuit
Long, Y., Chen, J., Guo, H., Dong, W., & Wu, Q. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3607953 · Cited by 2
“Bowden cable, sutured fabric, and fi xed anchor points to the human lower limb joints [15].”
Leestma, J. K., Nathella, S. R., Nuesslein, C. P. O., Mathur, S., Sawicki, G. S., & Young, A. J. (2026) · IEEE Access · doi:10.1109/access.2026.3743865 · Cited by 2
Twisted and Coiled Artificial Muscle-Based Dynamic Fixing System for Wearable Robotics Applications
Leone, S., Garofalo, S., Morano, C., Perrelli, M., Bruno, L., & Carbone, G. (2025) · Actuators · doi:10.3390/act14120581 · Cited by 2
Embodied Intelligence in Wearable Robotics
Hu, C., & Gionfrida, L. (2026) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/1343/1/012014 · Cited by 2
“The integration of these design features ensures that each wearable robot is not only mechanically functional but also ergonomically adapted to the user’s limb, reducing discomfort, friction, and potential injury during extended use [34].”
Zhang, S., Li, J., Li, W., Wang, X., Hong, Y., Li, F., & Wu, X. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3695524 · Cited by 2
“The second category of methods is non-model-based methods, including periodic gait generation strategies based on adaptive oscillators [22], gait generation strategies based on motion prediction [23], and gait generation strategies based on deep reinforcement learning [24].”
Okada, T., Okamoto, S., & Yamada, Y. (2020) · Virtual Reality · doi:10.1007/s10055-020-00452-8 · Cited by 2
Sorozábal, P., Delgado, G., Gutiérrez, Á., & Rocón, E. (2022) · Servizo de Publicacións da UDC eBooks · doi:10.17979/spudc.9788497498418.0128 · Cited by 2
Lee, S., & In, H. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340474 · Cited by 2
“Furthermore, the stiffness of the contact point should be considered because a higher stiffness increases the force transmission performance [1, 2].”
BackgroundKinematics Mathematical Modelling of Lower Limb Exoskeleton for Paralyzed Stroke Patients
Rahman, M. A. B. A., Chettiar, V. C. K., Aman, M. N. S. S., Chin, L. C., Basah, S. N., Takemura, H., & Yeap, E. J. (2024) · Journal of Advanced Research in Applied Sciences and Engineering Technology · doi:10.37934/araset.42.1.5772 · Cited by 2
Uncertainty Estimation of Human-Exoskeleton Interaction Using a Robotic Dummy
Massardi, S., Rodriguez-Cianca, D., Torricelli, D., & Lancini, M. (2024) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea60663.2024.10596858 · Cited by 2
“Therefore, ensuring correct fitting and alignment is crucial to prevent joints misalignments, and consequently relative movements between the exoskeleton frame and the user’s limbs [8].”
BackgroundLiu, Y., Sun, R., Zou, K., Li, Y., & Xu, P. W. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1429605 · Cited by 2
Kim, J., Nam, K., Yang, S., Moon, J., Yang, J., Ryu, J., & Lee, G. (2024) · Soft Robotics · doi:10.1089/soro.2023.0028 · Cited by 2
“Equation (4) and (5) denote the equations from Asbeck et al. 15 representing the logarithmic form of the stiffness model for the pulling and releasing phases, respectively. where P s is the cable travel length, which is denoted in rad unit.”
Soft hip walking assist experimental system featuring variable compliance control
John, S. W., Komatsu, M., Murakami, K., Ozawa, J., & Yamamoto, M. (2017) · International Conference on Consumer Electronics · doi:10.1109/icce.2017.7889370 · Cited by 2
“INTRODUCTION Soft assistance suits have recently been proposed for military load carrying applications [1][2], but we believe they also have significant potential for future consumer applications.”
BackgroundInfluence of maximum assistive force of a soft wearable robotic suit on metabolic cost reduction
Jin, S., Guo, S., Hashimoto, K., & Yamamoto, M. (2017) · IEEE Conference on Cybernetics and Intelligent Systems · doi:10.1109/iccis.2017.8274764 · Cited by 3
Xiloyannis, M., Dhinh, K. B., Cappello, L., Antuvan, C. W., & Masia, L. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-811810-8.00010-5 · Cited by 2
Li, N., Li, J., Yang, T. Y., Yang, Y., Yu, P., Liu, L., Qin, W., & Xi, N. (2019) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio49542.2019.8961616 · Cited by 2
“There are mainly six muscles[10]: ulnar flexor carpi (UFC), radial extensor carpi longus (RECL), radial flexor carpi (RFC), ulnar extensor carpi (UEC), palmar longus (PL) and radial extensor carpi brevis (RECB).”
BackgroundConditions for active assistance control of exoskeleton robot
Qiu, S., Guo, W. P., Zha, F., Wang, X., Sheng, W., Chen, F., & Caldwell, D. G. (2020) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm49381.2020.9195381 · Cited by 2
“Hence, many researches focus on the non-bioelectrical signal based method such as human dynamics model based method [10], adaptive frequency oscillator [11] and gait phase based method [12], [13].”
BackgroundA Novel Gait Prediction Method for Soft Exosuit Base on Limit Cycle and Neural Network
Chen, L., Chen, C., Fang, T., Zhang, Y., Liu, Y., & Wu, X. (2021) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom49281.2021.9398975 · Cited by 2
“It helps the users to reduce metabolic consumption while not interfering with the user’s normal exercise [4].”
BackgroundSimulation design of flexible Unpowerd lower limb exoskeleton
Wang, Y., Diao, Y., Ning, Y., Li, G., & Zhao, G. (2021) · IEEE International Conference on Real-time Computing and Robotics (RCAR) · doi:10.1109/rcar52367.2021.9517465 · Cited by 2
Narayan, J., Kalani, A., & Dwivedy, S. K. (2021) · Springer eBooks · doi:10.1007/978-3-030-58675-1_25-1 · Cited by 2
Dehghani-Sanij, A. A., & Martínez-Hernández, U. (2022) · Springer eBooks · doi:10.1007/978-3-031-07555-1_6 · Cited by 2
Jayakumar, A., Bermejo-García, J., Jorge, D., Agujetas, R., Romero, F., & Sánchez, F. J. A. (2023) · Actuators · doi:10.3390/act12080309 · Cited by 3
Development of a Soft Exosuit for Lifting and Lowering Loads
Moon, Y. J., Choi, M.-S., Lee, W.-L., Park, J., Shin, M., Cho, W., & Song, J.-W. (2023) · International Journal of Control Automation and Systems · doi:10.1007/s12555-022-0122-8 · Cited by 2
“…some studies have been conducted on the installation of a driving unit for the ankle and hip, focusing on the ankle and hip, rather than the knee, as the biological knee moment during walking is relatively small [24] and there are space-related problems installing a driving unit for the knee.”
BackgroundDesign and Evaluation of a Passive Hip Exoskeleton to Reduce the Energy Cost of Human Walking
van Wijdeven, M. A. P. (2016) · Research Repository (Delft University of Technology) · Cited by 2
A Design of Dynamic Exoskeleton for Self-learning Human Movements
Liu, Q., Yao, Y. P., Wang, D., & Peng, Y. (2022) · Proceedings of International Conference on Artificial Life and Robotics · doi:10.5954/icarob.2022.os9-5 · Cited by 1
Wearable Cable-driven Lower Limb Assistive Device with Demonstration System for Walking Assistance
Zhao, C., Lu, X., Li, J., Zhao, Z., & Feng, Y. (2022) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2213/1/012034 · Cited by 1
“[8-10] developed a multi-joint flexible lower-limb exoskeleton based on Bowden thread.”
MethodCompatible Structure Design of a Lower Limb Exoskeleton for Gait Assist
Zhao, D., Zhang, X., & Fu, H. (2021) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio54168.2021.9739409 · Cited by 1
A Segmented Dynamic Movement Primitives-Based Gait Assistive Strategy for Soft Ankle Exosuit
Xu, F., Huang, W., He, H., Li, N., He, H., & Li, K. (2023) · Lecture notes in computer science · doi:10.1007/978-981-99-6480-2_38 · Cited by 1
Choi, J., Feng, J., Cho, J., & Kim, J. (2025) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2025.3548686 · Cited by 1
“This transition aims to reduce excessive skin pressure and improve system autonomy, enhancing daily usability and user acceptance [16].”
Cho, S., Jeon, B., Kim, M. H., Chae, S., Ye, S., Jun, Y.-J., Park, Y., & Park, H. (2025) · Wearable Technologies · doi:10.1017/wtc.2025.10014 · Cited by 1
Staman, K., & van der Kooij, H. (2025) · Actuators · doi:10.3390/act14090443 · Cited by 1
Addressing Exoskeleton Architectural Diversity in Ergonomic and Biomechanical Studies
Min, K. S., Kazerooni, H., Tung, W. Y.-W., Pillai, M. V., & Engelhoven, L. V. (2025) · ASME Letters in Dynamic Systems and Control · doi:10.1115/1.4070144 · Cited by 1
Xu, M. Y., Dai, X., Zhou, Z., Wang, R., Jiang, D., Mai, J., & Wang, Q. (2025) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2025.3619121 · Cited by 1
“To date, plenty of passive [10], [11], [12], [13], [14] and active[15],[16],[17],[18],[19],[20]ankleexoskeletonshavebeen developedtoassistplantarflexorfunction.”
Reducing Lumbar Extensor Exertion in Lifting Tasks With a Powered Back Exosuit
Cullen, I., Nuesslein, C. P. O., & Young, A. J. (2026) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2026.3653879 · Cited by 1
“As such,priorresearchhasfocusedonusingexoskeletonstosupport userssupportinglumbarloadswhilewalkingupright[18],[19] orwhileliftingandloweringstrictlysymmetrically[20].”
A synergy-based lower limb exoskeleton that embodies natural human motor intelligence
Huang, B., Zhang, H., Sun, B.-Y., Chen, W., & Xiong, C. (2026) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/ae39c2 · Cited by 1
“In the field of lower limb wearable robotics, a multi-joint soft exosuit developed by Asbeck et al leverages an actuator to simultaneously assist hip and ankle joint motion during human walking by mimicking the muscle/force coordination mechanism between the two joints [38].”
Kaur, G., Qureshi, I., Bagde, A., Zade, S., & Gadbail, H. N. (2025) · International Conference on Emerging Applications of Material Science and Technology (ICEAMST) · doi:10.1109/iceamst67459.2025.11335767 · Cited by 1
“The integration of multiple sensor modalities, including inertial measurement units (IMUs), electromyographic (EMG) sensors, and force transducers, creates complex design challenges, particularly regarding power consumption and electromagnetic compatibility [5].”
The Metabolic Cost of Walking with a Passive Lower Limb Assistive Device
Martin, J.-P., & Li, Q. (2016) · Lecture notes in electrical engineering · doi:10.1007/978-981-10-2404-7_24 · Cited by 1
Jin, S., Guo, S., Hashimoto, K., & Yamamoto, M. (2017) · International Conference on Control, Automation and Systems (ICCAS) · doi:10.23919/iccas.2017.8204315 · Cited by 2
“Recently, soft walking assistive devices [11–16] are researched to avoid the drawbacks of exoskeletons.”
BackgroundLiu, Y., Liu, Y., Song, Q., Zhao, M., Liu, Y., & Ren, W. (2020) · IEEE Access · doi:10.1109/access.2020.3041744 · Cited by 1
“[7] developed a flexible device to drive the Bowden cable for human walking, and then the device was improved to the Autonomous Multi-Joint Soft Exosuit by which the metabolic cost reduced significantly [8], [9].”
MethodSelf Adjusting Exosuit for Shoulder
He, W., Zhang, W., & Ding, X. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-89095-7_68 · Cited by 1
Ergonomics Design and Assistance Strategy of A-Suit
Zhang, L., Gao, X. H., Cui, Y., Li, J., Ge, R., Jiao, Z., & Zhang, F. (2022) · Micromachines · doi:10.3390/mi13071114 · Cited by 1
“The method of experimental measurement is adopted to calculate the stiffness ktotal [26].”
MethodThe Study of Ankle Assisted Exoskeleton
Han, Y., Chang, J., Jin, Z., Liu, S., & Zhou, L. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-13835-5_15 · Cited by 1
Jeong, D.-H., Kang, D. Y., & Lee, J. S. (2023) · Journal of the Korean Society for Precision Engineering · doi:10.7736/jkspe.022.113 · Cited by 1
Design and Control of a Portable Soft Exosuit by Musculoskeletal Model-Based Optimization
Wang, N., Wang, Z., Li, Z., Xia, S., & Zhang, X. (2023) · Lecture notes in computer science · doi:10.1007/978-981-99-6486-4_34 · Cited by 1
Human-Robot Interaction Control for Multi-Mode Exosuit with Reinforcement Learning
Huang, K., Xu, J., Zhang, T., Zhao, M., Ji, A., Song, G., & Li, Y. (2024) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros58592.2024.10802309 · Cited by 1
“Youfu Li is with the Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, SAR, China (e-mail: meyfli@cityu.edu.hk). move more naturally [3-4].”
Gaskins, T., Gupta, P., Kumar, V., Pratihar, D. K., & Iqbal, F. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-22206-1.00008-5 · Cited by 1
RailBot-Rehab: A Novel Interactive Robotic System for Overground Gait Training
Ashiquzzaman, M., & Shen, X. (2025) · Journal of Medical Devices · doi:10.1115/1.4069291 · Cited by 1
Development and Testing of Novel Soft Sleeve Actuators
Abboodi, M. (2025) · arXiv (Cornell University) · doi:10.20381/ruor-31013 · Cited by 1
Quinlivan, B., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., & Walsh, C. J. (2016)
Self-citationEvaluation of long-term effect on gait improvement for a soft robotic suit
Jin, S., Guo, S., Hashimoto, K., & Yamamoto, M. (2017) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2017.8324655
Exoesqueleto de membro inferior com dois graus de liberdade ativos.
Souit, C. (2018) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.3.2018.tde-20042018-092116
Non-Biological Signal Based Control System for Exoskeletons
Sun, Y. (2017) · DEStech Transactions on Engineering and Technology Research · doi:10.12783/dtetr/3rd/amma2017/14779
The Inverted Muscle Skeleton Approach: Moving Beyond Rigid Exoskeletons
Grootens, M. E., Hekman, E. E. G., & van der Kooij, H. (2018) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2018.8487703
“These shear forces act directly on the skin and underlying tissue of the wearer of the suit, which means that the maximum joint torques are limited by the maximum shear force that the wearer of an exosuit can support [16].”
BackgroundAdaptive Controllers for Assistive Robotic Devices
Koller, J. R. (2017) · Deep Blue (University of Michigan)
Evaluation of a Soft Robotic Knee Exosuit for Assistance in Stair Ascent
Muthukrishnan, N. (2018) · Arizona State University Library Digital Repository (Arizona State University)
The Research on Exoskeletons with Focus on the Locomotion Support
Wang, J., & Lyu, L. (2020) · Pomiary, Automatyka, Robotyka · doi:10.14313/par_236/17
Structure Design and Closed-Loop Control of a Modular Soft-Rigid Pneumatic Lower Limb Exoskeleton
Wang, J., & Fei, Y. (2020) · Springer eBooks · doi:10.1007/978-3-030-43703-9_17
Assist Timing Decision Method for Wire Type Walking Assist Suit by Hip Joint Angular Acceleration
Zhang, J., Murai, H., Ito, A., TSUJIUCHI, N., INOUE, T., Murakami, K., Hanzawa, F., Kishimoto, K., & Ozawa, J. (2020) · IEEE Global Conference on Consumer Electronics (GCCE) · doi:10.1109/gcce50665.2020.9292018
“More recently, wire type assist suits (hereinafter referred to as wire-types) have been developed to solve these problems [1] [2].”
BackgroundHuang, G., Zhou, Z., Liang, B., Nong, J., Liu, Y., & Xie, L. (2020) · doi:10.21203/rs.3.rs-55923/v1
“Two representative robots are exosuits developed by Harvard University and the autonomous robots developed by MIT [3, 5, 9, 10].”
MethodThree-dimensional functionalized film printing for health monitoring
Singh, S., Ramakrishna, S., & Hussain, C. M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823152-4.00007-7 · Cited by 1
Improving the Assisting Efficiency of Ankle Robot through Energy Harvesting of Achilles TendonPreprint
Huang, G., Wang, Z., Liu, B., Zhou, Z., Xian, X., & Xie, L. (2020) · Research Square · doi:10.21203/rs.3.rs-30546/v1
“One advantage is that the small assisting force has little effect on gait [30].”
BackgroundDesign of Intelligent Tourism Etiquette Training Framework based on Attitude Detection System
Ma, S. (2021) · International Conference on Communication and Electronics Systems (ICCES) · doi:10.1109/icces51350.2021.9489042
“It is not possible to improve the quality of national tourism only by relying on the civilized convention on paper [1-4].”
BackgroundThe battle for Port-en-Bessin 6-8 June 1944: a medical officer with a Royal Marine Commando.
Jo, F. (1994) · PubMed · Cited by 1
Narayan, J., Kalani, A., & Dwivedy, S. K. (2022) · Springer eBooks · doi:10.1007/978-3-030-84205-5_25
Jayakumar, A., Jorge, D., Bermejo, G., Agujetas, R., Romero Sánchez, F., & Sánchez, F. J. A. (2022) · Congreso Iberoamericano de Ingeniería Mecánica (CIBIM) · doi:10.5944/bicim2022.102
“Uno de los primeros trabajos que abordan el uso de exosuits de miembro inferior [1],[2] utiliza textiles para la transmisión de fuerza.”
Development of a Passive Exoskeleton for Assistance in Carrying Coronal Plane Loads
Wu, J., Zhang, Y., Zhang, Y., Yan, M., & Wang, X. (2023) · IEEE International Conference on Industrial Engineering and Applications (ICIEA) · doi:10.1145/3587889.3588204
“respiratory flow, and body temperature [17] [18] [19] has large errors and it is difficult to objectively describe how the system makes people feel.”
Background
Metadata
- Authors
- Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J.
- Affiliations
- Harvard University (US)
- Harvard University, Cambridge, MA, USA
- Boston University (US)
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2015-03-16
- Volume
- 34
- Issue
- 6
- Pages
- 744-762
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2169410184
- Semantic Scholar
- 6f5747b1e1a55a0b7c475d4d70e90e139f3e74d5
- Cited by
- 450
- References
- 66
- Citations by year
- 2026: 34 · 2025: 43 · 2024: 38 · 2023: 40 · 2022: 39 · 2021: 63 · 2020: 48 · 2019: 43 · 2018: 42 · 2017: 33 · 2016: 21 · 2015: 4
- FWCI
- 16.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The International Journal of Robotics Research (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- soft exosuit, gait assistance, biologically inspired design, energy cost of walking, loaded walking, gait kinematics, wearable robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.