Does Platelet-Rich Plasma Accelerate Recovery After Rotator Cuff Repair? A Prospective Cohort Study
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Background: Platelet-rich plasma (PRP) has been recently used to enhance and accelerate the healing of musculoskeletal injuries and diseases, but evidence is still lacking, especially on its effects after rotator cuff repair. Hypothesis: Platelet-rich plasma accelerates recovery after arthroscopic rotator cuff repair in pain relief, functional outcome, overall satisfaction, and enhanced structural integrity of repaired tendon. Study Design: Cohort study; Level of evidence, 2. Methods: Forty-two patients with full-thickness rotator cuff tears were included. Patients were informed about the use of PRP before surgery and decided themselves whether to have PRP placed at the time of surgery. Nineteen patients underwent arthroscopic rotator cuff repair with PRP and 23 without. Platelet-rich plasma was prepared via plateletpheresis and applied in the form of a gel threaded to a suture and placed at the interface between tendon and bone. Outcomes were assessed preoperatively and at 3, 6, 12, and finally at a minimum of 16 months after surgery (at an average of 19.7 ± 1.9 months) with respect to pain, range of motion, strength, and overall satisfaction, and with respect to functional scores as determined using the following scoring systems: the American Shoulder and Elbow Surgeon (ASES) system, the Constant system, the University of California at Los Angeles (UCLA) system, the Disabilities of the Arm, Shoulder and Hand (DASH) system, the Simple Shoulder Test (SST) system, and the Shoulder Pain and Disability Index (SPADI) system. At a minimum of 9 months after surgery, repaired tendon structural integrities were assessed by magnetic resonance imaging. Results: Platelet-rich plasma gel application to arthroscopic rotator cuff repairs did not accelerate recovery with respect to pain, range of motion, strength, functional scores, or overall satisfaction as compared with conventional repair at any time point. Whereas magnetic resonance imaging demonstrated a retear rate of 26.7% in the PRP group and 41.2% in the conventional group, there was no statistical significance between the groups ( P = .388). Conclusion: The results suggest that PRP application during arthroscopic rotator cuff repair did not clearly demonstrate accelerated recovery clinically or anatomically except for an improvement in internal rotation. Nevertheless, as the study may have been underpowered to detect clinically important differences in the structural integrity, additional investigations, including the optimization of PRP preparation and a larger randomized study powered for healing rate, are necessary to further determine the effect of PRP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transforming Growth Factor β in Tissue Fibrosis
Epstein, F. H., Border, W. A., & Noble, N. A. (1994) · New England Journal of Medicine · doi:10.1056/nejm199411103311907 · Cited by 3,069
Galatz, L. M., Ball, C. M., Teefey, S. A., Middleton, W. D., & Yamaguchi, K. (2004) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-200402000-00002 · Cited by 2,145 · cited 1×
“biomechanical advances in fixation, rates of retear are still high.(16,24) Tendons consume little energy, and as a consequence healing is slow after injury.”
BackgroundPlatelet-Rich Plasma (PRP): What Is PRP and What Is Not PRP?
Marx, R. E. (2001) · Implant Dentistry · doi:10.1097/00008505-200110000-00002 · Cited by 1,704
Arthroscopic Repair of Full-Thickness Tears of the Supraspinatus: Does the Tendon Really Heal?
Boileau, P. (2005) · The Journal of Bone and Joint Surgery (American) · doi:10.2106/jbjs.d.02035 · Cited by 1,248
Dohan, D. M., Choukroun, J., Diss, A., Dohan, S. L., Dohan, A. J. J., Mouhyi, J., & Gogly, B. (2006) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2005.07.009 · Cited by 1,191
The Roles of Growth Factors in Tendon and Ligament Healing
Molloy, T., Wang, Y., & Murrell, G. A. C. (2003) · Sports Medicine · doi:10.2165/00007256-200333050-00004 · Cited by 948
Results of a second attempt at surgical repair of a failed initial rotator-cuff repair.
DeOrio, J. K., & Cofield, R. H. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466040-00011 · Cited by 919
Comparison of Surgically Repaired Achilles Tendon Tears Using Platelet-Rich Fibrin Matrices
Sánchez, M., Anitua, E., Azofra, J., Andía, I., Padilla, S., & Mujika, I. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546506294078 · Cited by 653
Platelet-Rich Plasma and Platelet Gel: A Review
Everts, P. A. M., Knape, J. T. A., Weibrich, G., Schönberger, J. P. A. M., Hoffmann, J., Overdevest, E. P., Box, H. A. M., & van Zundert, A. (2006) · The Journal of ExtraCorporeal Technology · doi:10.1051/ject/200638174 · Cited by 580 · cited 2×
“For the application to rotator cuff repair, platelet counts in PRP were adjusted with saline to 1000 3 10(3) platelets per microliter.(14) To produce a gel from prepared PRP, 0.”
BackgroundMethodPlatelet rich plasma injection grafts for musculoskeletal injuries: a review
Sampson, S., Gerhardt, M., & Mandelbaum, B. (2008) · Current Reviews in Musculoskeletal Medicine · doi:10.1007/s12178-008-9032-5 · Cited by 576 · cited 1×
“Tendons consume little energy, and as a consequence healing is slow after injury.(37,39) Increasing the speed of healing would allow earlier return to work, sport, and activities of daily living, which would be helpful for both the elite athlete and general public.”
Background
Cited by
Platelet-Rich Plasma: The PAW Classification System
DeLong, J. M., Russell, R. P., & Mazzocca, A. D. (2012) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2012.04.148 · Cited by 623
Chahla, J., Cinque, M. E., Piuzzi, N. S., Mannava, S., Geeslin, A. G., Murray, I. R., Dornan, G. J., Muschler, G. F., & LaPrade, R. F. (2017) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.16.01374 · Cited by 504
Mishra, A. K., Skrepnik, N. V., Edwards, S. G., Jones, G. L., Sampson, S., Vermillion, D. A., Ramsey, M. L., Karli, D. C., & Rettig, A. C. (2014) · The American Journal of Sports Medicine · doi:10.1177/0363546513494359 · Cited by 396
Efficacy of Autologous Platelet-Rich Plasma Use for Orthopaedic Indications: A Meta-Analysis
Sheth, U., Simunovic, N., Klein, G., Fu, F., Einhorn, T. A., Schemitsch, E., Ayeni, O. R., & Bhandari, M. (2012) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.k.00154 · Cited by 294
Jo, C. H., Kim, J. E., Yoon, K. S., & Shin, S. (2012) · The American Journal of Sports Medicine · doi:10.1177/0363546512437525 · Cited by 248
Self-citationWu, P. I.-K., Diaz, R., & Borg-Stein, J. (2016) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2016.06.002 · Cited by 247
“Following initial safety studies,(76) early, underpowered studies demonstrated no significant benefit to pain or function of PRP augmentation during arthroscopic rotator cuff repair.(77,78) Intraoperative local application of autologous PRP to the arthroscopic repair site of complete rotator cuff tears has been associ…”
BackgroundHurley, E. T., Lim Fat, D., Moran, C. J., & Mullett, H. (2019) · The American Journal of Sports Medicine · doi:10.1177/0363546517751397 · Cited by 223
Platelet-rich plasma in tendon-related disorders: results and indications
Filardo, G., Di Matteo, B., Kon, E., Merli, G., & Marcacci, M. (2018) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-016-4261-4 · Cited by 222
Jo, C. H., Shin, J. S., Lee, Y. G., Shin, W. H., Kim, H., Lee, S. Y., Yoon, K. S., & Shin, S. (2013) · The American Journal of Sports Medicine · doi:10.1177/0363546513497925 · Cited by 221
Self-citationPlatelet Derivatives in Regenerative Medicine: An Update
De Pascale, M. R., Sommese, L., Casamassimi, A., & Napoli, C. (2015) · Transfusion Medicine Reviews · doi:10.1016/j.tmrv.2014.11.001 · Cited by 196
Weber, S. C., Kauffman, J. I., Parise, C., Weber, S. J., & Katz, S. D. (2013) · The American Journal of Sports Medicine · doi:10.1177/0363546512467621 · Cited by 194
Platelet-rich Plasma in Orthopaedic Applications: Evidence-based Recommendations for Treatment
Hsu, W. K., Mishra, A., Rodeo, S. R., Fu, F., Terry, M. A., Randelli, P., Canale, S. T., & Kelly, F. B. (2013) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/jaaos-21-12-739 · Cited by 190
Platelet-rich plasma (PRP): Methodological aspects and clinical applications
Marques, L. F., Stessuk, T., Camargo, I. C. C., Sabeh Junior, N., Santos, L. D., & Ribeiro-Paes, J. T. (2015) · Platelets · doi:10.3109/09537104.2014.881991 · Cited by 186
“In this way, authors suggest the use in bigger-sized lesions, since the different methods commercially available may lead to more efficient preparations [90–92].”
MethodChahal, J., Van Thiel, G. S., Mall, N., Heard, W., Bach, B. R., Cole, B. J., Nicholson, G. P., Verma, N. N., Whelan, D. B., & Romeo, A. A. (2012) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2012.03.007 · Cited by 179
Kim, Y. S., Sung, C. H., Chung, S. H., Kwak, S. J., & Koh, Y. G. (2017) · The American Journal of Sports Medicine · doi:10.1177/0363546517702863 · Cited by 176
“Therefore, many efforts to mechanically support the repair construct and biologically enhance tendon-to-bone healing have been undertaken to decrease the failure rate after rotator cuff repair.(10,28) Recently, mesenchymal stem cells (MSCs) have been suggested as a potential cell-based therapy for the treatment of rot…”
Shams, A., El-Sayed, M., Gamal, O., & Ewes, W. (2016) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-016-1826-3 · Cited by 175
RetractedJo, C. H., Shin, J. S., Shin, W. H., Lee, S. Y., Yoon, K. S., & Shin, S. (2015) · The American Journal of Sports Medicine · doi:10.1177/0363546515587081 · Cited by 166
Self-citationPlatelet Rich Plasma in Rotator Cuff Repair
Gamradt, S. C., Rodeo, S. A., & Warren, R. F. (2007) · Techniques in Orthopaedics · doi:10.1097/01.bto.0000261868.03232.dd · Cited by 165
Metadata
- Authors
- Jo, C. H., Kim, J. E., Yoon, K. S., Lee, J. H., Kang, S. B., Lee, J. H., Han, H. S., Rhee, S. H., & Shin, S.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2011-07-07
- Volume
- 39
- Issue
- 10
- Pages
- 2082-2090
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2096274538
- Cited by
- 229
- References
- 38
- FWCI
- 24.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.