A Simulation Study on a Self-Tuning Portable Controller of Blood Glucose
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A self-tuning, nonlinear controller was developed to drive portable or implantable micro-pumps for blood glucose control in diabetic subjects. The parameter estimation is based on a recursive least-square algorithm applied to a discrete time simplified mathematical model of the glucose system; the controller, which is integrated with the estimator, uses an-extended minimum-variance method. The software was designed to drive a micro-controller wearable unit, operating with different kinds of glucose sensors, in order to perform chemical and biological experimentations. Some strategies were introduced to avoid hypoglycaemia, even tolerating a reduction in control speed and accuracy. The whole system was tested in a simulation study, performed on a mathematical model implemented on a personal computer. The tests were performed while simulating different controller structures and settings, and patient responses. They showed a satisfactory control behaviour, mostly as far as stability and robustness are concerned, in all simulated conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Research works printed but not linked: 21
- 10.2337/diacare.13.9.955 · DOI · Paper page
- Kadish A.H., 1964, A servomechanism for glucose monitoring and control. Am J Med Electronics, 3, 82
- 10.1007/BF02477386 · DOI
- Pfeiffer E.F., 1974, A continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system). Horm Metab Res, 6, 339
- Fischer U., 1978, Endokrinologie, 71, 65
- Goriya Y., 1979, Med Prog Technol, 6, 99
- 1976, Biostator GCIIS, Operation Manual.
- Betalike Operating Manual.
- 10.1109/TBME.1983.325203 · DOI · Paper page
- Fischer U., 1984, Int J Artif Organs, 4, 794
- 10.1016/S0140-6736(82)92788-X · DOI · Paper page
- 10.1007/BF00250158 · DOI
- Shichiri M., 1984, Biomed Biochem Acta, 43, 561
- Shichiri M., 1991, Problems awaiting solutions for long term use (Abstract). Med & Biol Eng & Comput, 29, 358
- Vadgama P., 1991, Med & Biol Eng & Comput, 29, 661
- 10.1177/039139889101400805 · DOI
- 10.1177/039139889101400310 · doi:10.1177/039139889101400310
- 10.1049/piee.1975.0252 · doi:10.1049/piee.1975.0252
- 10.1007/BF02442625 · DOI
- 10.1016/0025-5564(84)90114-7 · DOI
- WellsteadP.E., ZarropM.B. Self-tuning systems: control and signal processing. Chichester: John Wiley, 1991: 147.
Cited by
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
“…infused insulin (Cobelli and Mari 1985) and only with the availability of short-acting insulin (Howey et al 1994) could the next generation of control algorithms have been developed (Brunetti et al 1993, Candas and Radziuk 1994, Shichiri et al 1998, Shimoda et al 1997, Trajanoski and Wach 1998).”
BackgroundIn Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Self-citationArtificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Self-citationEl-Khatib, F. H., Jiang, J., & Damiano, E. R. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100208 · Cited by 99
Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility
Cobelli, C., & Kovatchev, B. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231195081 · Cited by 46
Self-citation
Metadata
- Authors
- Brunetti, P., Cobelli, C., Cruciani, P., Fabietti, P. G., Filippucci, F., Santeusanio, F., & Sarti, E.
- Venue
- The International Journal of Artificial Organs
- Publisher
- SAGE Publications
- Published
- 1993-01
- Volume
- 16
- Issue
- 1
- Pages
- 51-57
- ISSN
- 0391-3988 (ISSN-L)
- 1724-6040
- OpenAlex
- W2405719558
- Cited by
- 26
- References
- 1
- FWCI
- 0.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Simulation Study on a Self-Tuning Portable Controller of Blood Glucose. https://app.cochat.ai/papers/10.1177/039139889301600111
- The paper
- Brunetti, P., Cobelli, C., Cruciani, P., Fabietti, P. G., Filippucci, F., Santeusanio, F., & Sarti, E. (1993). A Simulation Study on a Self-Tuning Portable Controller of Blood Glucose. The International Journal of Artificial Organs. https://doi.org/10.1177/039139889301600111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.