Quantifying Human Circadian Pacemaker Response to Brief, Extended, and Repeated Light Stimuli over the Phototopic Range
The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.
Abstract
The authors' previous models have been able to describe accurately the effects of extended (5 h) bright-light (>4000 lux) stimuli on the phase and amplitude of the human circadian pacemaker, but they are not sufficient to represent the surprising human sensitivity to both brief pulses of bright light and light of more moderate intensities. Therefore, the authors have devised a new model in which a dynamic stimulus processor ( Process L) intervenes between the light stimuli and the traditional representation of the circadian pacemaker as a self-sustaining limit-cycle oscillator ( Process P). The overall model incorporating Process L and Process P is intended to allow the prediction of phase shifts to photic stimuli of any temporal pattern (extended and brief light episodes) and any light intensity in the photopic range. Two time constants emerge in the Process Lmodel: the characteristic duration for necessary bright-light pulses to achieve their full effect (5-10 min) and the characteristic stimulus-free (dark) interval that can be tolerated without incurring an excessive penalty in phase shifting (30-80 min). The effect of reducing light intensity is incorporated in Process L as an extension of the time necessary for the light pulse to be fully realized (a power-law relation between time and intensity). This new model generates a number of new testable hypotheses, including the surprising prediction that 24-h cycles consisting of8hof darkness and 16 h of only 3.5 lux would be capable of entraining a large fraction of the adult population (45%). Experimental data on the response of the human circadian system to lower light intensities and briefer stimuli are needed to allow for further refinement and validation of the model proposed here.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The human circadian system integrates across multiple light exposures as short as five minutes [48], even intermittent bright light exposure can shift the circadian phase [43, 66].”
From Effects of light on human circadian rhythms, sleep and mood (2019) · cites this paper as [48]
Citations
Cites
Stability, precision, and near-24-hour period of the human circadian pacemaker
Czeisler, C. A., Duffy, J. F., Shanahan, T. L., Brown, E. N., Mitchell, J. F., Rimmer, D. W., Ronda, J. M., Silva, E. J., Allan, J. S., Emens, J. S., et al. (1999) · Science · doi:10.1126/science.284.5423.2177 · Cited by 1,705 · cited 6×
“13 h (Czeisler et al., 1999), the phase advance due to the light itself is actually larger by ~1.”
BackgroundInfluentialSelf-citationExogenous and Endogenous Components in Circadian Rhythms
Aschoff, J. (1960) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.1960.025.01.004 · Cited by 1,479 · cited 1×
“In the sense of Aschoff (1960), this effect is nonparametric.”
BackgroundShigeyoshi, Y., Taguchi, K., Yamamoto, S., Takekida, S., Yan, L., Tei, H., Moriya, T., Shibata, S., Loros, J. J., Dunlap, J. C., et al. (1997) · Cell · doi:10.1016/s0092-8674(00)80494-8 · Cited by 891 · cited 1×
“Data indicate that mPer1 peaks rapidly after stimulus onset (within 60 min or less) and maximum response can be achieved with a 5-min stimulus of sufficiently bright light (Shigeyoshi et al., 1997).”
BackgroundDose-response relationships for resetting of human circadian clock by light
Boivin, D. B., Duffy, J. F., Kronauer, R. E., & Czeisler, C. A. (1996) · Nature · doi:10.1038/379540a0 · Cited by 559 · cited 3×
“First, extended stimuli using ordinary room light (100-200 lux) have been found to have about half the effectiveness of very bright light (~10,000 lux) (Boivin et al., 1996).”
BackgroundMethodSelf-citationNelson, D. E., & Takahashi, J. S. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018660 · Cited by 316 · cited 2×
“Nelson and Takahashi (1991) measured phase shifts in hamster free-running rhythms as a function of I with the duration of the light pulse as a parameter.”
BackgroundDaan, S., & Pittendrigh, C. S. (1976) · Journal of Comparative Physiology ? A · doi:10.1007/bf01417858 · Cited by 298
The suprachiasmatic nuclei contain a tetrodotoxin-resistant circadian pacemaker.
Schwartz, W. J., Gross, R. A., & Morton, M. T. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.6.1694 · Cited by 257 · cited 2×
“Since Schwartz et al. (1987) showed that neuronal firing is, in an important sense, an epiphenomenon not essential to pacemaker rhythm persistence, it is not clear that neuron firing reflects the response of the underlying biochemical process, at least not immediately.”
BackgroundLight-induced suppression of endogenous circadian amplitude in humans
Jewett, M. E., Kronauer, R. E., & Czeisler, C. A. (1991) · Nature · doi:10.1038/350059a0 · Cited by 253 · cited 1×
“It is bidirectional and has been incorporated to represent the extreme difficulty in timing critical stimuli so as to achieve strong amplitude suppression (Jewett et al., 1991, 1994).”
BackgroundSelf-citationDuffy, J. F., Kronauer, R. E., & Czeisler, C. A. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021593 · Cited by 236 · cited 1×
“This phase-delay “drift” due to τx > 24 has been shown directly by control experiments in which darkness replaced I0 (Duffy et al., 1996).”
BackgroundSelf-citation(1995) · Progress in Brain Research · doi:10.1016/s0079-6123(08)61776-8 · Cited by 224
Research works printed but not linked: 8
- Gershengorn H, 1998, Soc Res Biol Rhythms, 6, 120
- Khalsa SBS, 1997, Sleep Res, 26, 722
- Klerman EB, 1996, Am J Physiol, 270, R271
- Kronauer RE, 1990, Sleep '90, Proceedings of the Tenth European Congress on Sleep Research, 306
- Kronauer RE, 1982, Am J Physiol, 242, R3
- Kronauer RE, 1998, Biological Clocks, Mechanisms and Applications, 63
- Rimmer DW, 1995, Sleep Res, 24, 538
- Zeitzer JM (1999) Physiology and anatomy of human circadian photoreception and melatonin regulation. PhD dissertation, Harvard University, Cambridge, MA.
Cited by
Effects of light on human circadian rhythms, sleep and mood
Blume, C., Garbazza, C., & Spitschan, M. (2019) · Somnologie · doi:10.1007/s11818-019-00215-x · Cited by 695
Daily Light Exposure Patterns Reveal Phase and Period of the Human Circadian Clock
Woelders, T., Beersma, D. G. M., Gordijn, M. C. M., Hut, R. A., & Wams, E. J. (2017) · Journal of Biological Rhythms · doi:10.1177/0748730417696787 · Cited by 106
“One mathematical model that has been particularly accurate in modeling the circadian response to light is the limit-cycle oscillator model developed by Kronauer and others (Kronauer, 1990; Kronauer et al., 1999) with revised versions presented by Jewett et al. (1999) and St. Hilaire et al. (2007b).”
MethodOptimal Schedules of Light Exposure for Rapidly Correcting Circadian Misalignment
Serkh, K., & Forger, D. B. (2014) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1003523 · Cited by 108
“These models contain two components: ‘‘Process L,’’ which simulates phototransduction in the retina [21], and a ‘‘Process P,’’ whose two variables represent the state of the central circadian pacemaker, located in the suprachiasmatic nucleus of the hypothalamus.”
BackgroundResultSelf-citationProbing the Mechanisms of Chronotype Using Quantitative Modeling
Phillips, A. J. K., Chen, P. Y., & Robinson, P. A. (2010) · Journal of Biological Rhythms · doi:10.1177/0748730410369208 · Cited by 97
“The term (1− bx)(1− by) is included to account for the experimentally observed circadian phase dependence of light sensitivity (Kronauer et al., 1999).”
BackgroundMethodInfluentialUnweaving the human response in daylighting design
Andersen, M. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.03.014 · Cited by 114
Metadata
- Authors
- Kronauer, R. E., Forger, D. B., & Jewett, M. E.
- Affiliations
- Brigham and Women's Hospital (US)
- Harvard University (US)
- ORCID
- Forger, Daniel B.
- Venue
- Journal of Biological Rhythms
- Publisher
- SAGE Publications
- Published
- 1999-12
- Volume
- 14
- Issue
- 6
- Pages
- 501-516
- ISSN
- 0748-7304 (ISSN-L)
- 1552-4531
- OpenAlex
- W4247702682
- Cited by
- 74
- References
- 19
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 4 · 2023: 8 · 2022: 7 · 2021: 4 · 2020: 9 · 2019: 5 · 2018: 6 · 2017: 3 · 2016: 3 · 2015: 2 · 2014: 1 · 2013: 6 · 2012: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Biological Rhythms (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and Work-Related Fatigue
- Physical Sciences › Environmental Science › Global and Planetary Change › Impact of Light on Environment and Health
- Keywords
- circadian pacemaker, phase shift, bright light exposure, light intensity, limit-cycle oscillators, circadian entrainment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantifying Human Circadian Pacemaker Response to Brief, Extended, and Repeated Light Stimuli over the Phototopic Range. https://app.cochat.ai/papers/10.1177/074873049901400609
- The paper
- Kronauer, R. E., Forger, D. B., & Jewett, M. E. (1999). Quantifying Human Circadian Pacemaker Response to Brief, Extended, and Repeated Light Stimuli over the Phototopic Range. Journal of Biological Rhythms. https://doi.org/10.1177/074873049901400609
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.