Application of Electromechanical Impedance Technique for Engineering Structures: Review and Future Issues
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
The recent advent of highly durable engineering materials and the advancement of latest structural design theories have made possible the fabrication of more efficient engineering structures. However, the safety and reliability of these structures remains the primary challenge and concern for engineers. Especially, for those structures which involve human traffic and huge investments such as the aerospace structures and bridges. Therefore, there is a compelling need to have high-quality online structural health monitoring (SHM) of such structures. The development of a real-time, in-service, and smart material-based SHM method has recently attracted the interest of a large number of academic and industrial researchers. In the recent past, piezoceramic (PZT) transducer has evolved as an efficient smart material, which is usually employed in electro mechanical impedance (EMI) and guided ultrasonic wave propagation techniques. In EMI technique, a PZT transducer interact with the host structure to result in unique health signature, as an inverse function of structural impedance, when it is subjected to high-frequency structural excitations in the presence of electric field. Using the self-actuating and sensing capabilities of PZT transducers, the EMI models attempted to detect loadings on, and damages in, the structures to be monitored. This article reviews some of the advancements in the field of PZT-based SHM made over the past two decades in engineering structures. This article also provides an insight into the possible future work and improvements required for PZT-based EMI technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Summary Review of Vibration-Based Damage Identification Methods
Doebling, S. W., Farrar, C. R., & Prime, M. B. (1998) · The Shock and Vibration Digest · doi:10.1177/058310249803000201 · Cited by 2,823 · cited 1×
“Unlike low frequency global excitations models (Pandey et al., 1991; Doebling et al., 1998), this highfrequency-based EMI models are limited to local area.”
Use of piezoelectric actuators as elements of intelligent structures
Crawley, E. F., & de Luis, J. (1987) · AIAA Journal · doi:10.2514/3.9792 · Cited by 2,602 · cited 1×
“Several PZT structure interaction models have been developed in the last couple of decades, first by Crawley and Luis (1987) and Liang et al. (1994), and subsequently by Chaudhry et al. (1995), Sun et al. (1995), Park (2000), Park et al. (2000a,b), Giurgiutiu et al. (1999), Giurgiutiu et al.…”
Damage detection from changes in curvature mode shapes
Pandey, A. K., Biswas, M., & Samman, M. M. (1991) · Journal of Sound and Vibration · doi:10.1016/0022-460x(91)90595-b · Cited by 2,077 · cited 1×
“Unlike low frequency global excitations models (Pandey et al., 1991; Doebling et al., 1998), this highfrequency-based EMI models are limited to local area.”
Structural Health Monitoring with Piezoelectric Wafer Active Sensors
(2014) · Elsevier eBooks · doi:10.1016/c2013-0-00155-7 · Cited by 1,398
Overview of Piezoelectric Impedance-Based Health Monitoring and Path Forward
Park, G., Sohn, H., Farrar, C. R., & Inman, D. J. (2003) · The Shock and Vibration Digest · doi:10.1177/05831024030356001 · Cited by 1,060 · cited 8×
“…interact with the host structure to result-in a unique health signature, when subjected to high-frequency structural excitations in the presence of electric field (Liang et al., 1994; Giurgiutiu and Zagrai 2000; Niezrecki et al., 2001; Chopra, 2002; Park et al., 2003a,b; Annamdas and Soh, 2007a,b).”
InfluentialLiang, C., Sun, F. P., & Rogers, C. A. (1994) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9400500102 · Cited by 790 · cited 10×
“…interact with the host structure to result-in a unique health signature, when subjected to high-frequency structural excitations in the presence of electric field (Liang et al., 1994; Giurgiutiu and Zagrai 2000; Niezrecki et al., 2001; Chopra, 2002; Park et al., 2003a,b; Annamdas and Soh, 2007a,b).”
InfluentialReview of State of Art of Smart Structures and Integrated Systems
Chopra, I. (2002) · AIAA Journal · doi:10.2514/2.1561 · Cited by 787 · cited 1×
“…interact with the host structure to result-in a unique health signature, when subjected to high-frequency structural excitations in the presence of electric field (Liang et al., 1994; Giurgiutiu and Zagrai 2000; Niezrecki et al., 2001; Chopra, 2002; Park et al., 2003a,b; Annamdas and Soh, 2007a,b).”
Fundamental Understanding of Piezoelectric Strain Sensors
Sirohi, J., & Chopra, I. (2000) · Journal of Intelligent Material Systems and Structures · doi:10.1106/8bfb-gc8p-xq47-ycq0 · Cited by 777 · cited 3×
“Crawley and de Luis (1987), Sirohi and Chopra (2000), respectively, modeled the actuation and sensing of generic beam elements by an adhesively bonded PZT transducer.”
A Self-Sensing Piezoelectric Actuator for Collocated Control
Dosch, J. J., Inman, D. J., & Garcia, E. (1992) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9200300109 · Cited by 767
Journal of intelligent material systems and structures
(1990) · Materials & Design (1980-2015) · doi:10.1016/0261-3069(90)90079-y · Cited by 691
Piezoelectric Wafer Embedded Active Sensors for Aging Aircraft Structural Health Monitoring
Victor Giurgiutiu, B., Zagrai, A., & Bao, J. J. (2002) · Structural Health Monitoring · doi:10.1177/147592170200100104 · Cited by 623 · cited 2×
“Giurgiutiu et al. (2002) combined the EMI technique with wave propagation approach for crack detection in aircraft components.”
Low-cost piezocomposite actuator for structural control applications:
Wilkie, W. K., Bryant, R. G., High, J. W., Fox, R. L., Hellbaum, R. F., Jalink, Jr., Little, B. D., & Mirick, P. H. (2000) · SPIE Proceedings · doi:10.1117/12.388175 · Cited by 469 · cited 2×
“The MFC actuator (http:// www.smart-material.com/MFC,2009), developed by researchers at NASA (2008) Langley Research Center (Wilkie et al., 2000) has the capability to restrict actuations to either 1 or 2 directions.”
Impedance-Based Health Monitoring of Civil Structural Components
Park, G., Cudney, H. H., & Inman, D. J. (2000) · Journal of Infrastructure Systems · doi:10.1061/(asce)1076-0342(2000)6:4(153 · Cited by 460 · cited 4×
“Researchers in the past tested the applicability of both surface bonded and embedded PZTs on same type of host structures (Park et al., 2000a,b).”
InfluentialPerformance of smart piezoceramic patches in health monitoring of a RC bridge
Soh, C. K., Tseng, K. K.-H., Bhalla, S., & Gupta, A. (2000) · Smart Materials and Structures · doi:10.1088/0964-1726/9/4/317 · Cited by 407 · cited 1×
“Soh et al. (2000) established the damage detection and localization ability of these transducers for real-life reinforced concrete (RC) structures by monitoring a 5m span RC bridge during its destructive load testing.”
Self-citationStructural Health Monitoring by Piezo-Impedance Transducers. I: Modeling
Bhalla, S., & Soh, C. K. (2004) · Journal of Aerospace Engineering · doi:10.1061/(asce)0893-1321(2004)17:4(154 · Cited by 351 · cited 5×
“The surface-bonded PZT transducer should have thin adhesive layer preferably one-third of the thickness of PZT transducer (Bhalla and Soh, 2004c).”
InfluentialSelf-citationHydrosystems engineering and management
Mays, L. W., & Tung, Y. (1991) · Cited by 310
Electro-Mechanical Impedance Method for Crack Detection in Thin Plates
Zagrai, A., & Victor Giurgiutiu, B. (2001) · Journal of Intelligent Material Systems and Structures · doi:10.1177/104538901320560355 · Cited by 297 · cited 1×
“…subsequently by Chaudhry et al. (1995), Sun et al. (1995), Park (2000), Park et al. (2000a,b), Giurgiutiu et al. (1999), Giurgiutiu et al. (2002), Zagrai and Giurgiutiu (2001), Bandar and Abdulmalik (2003), Bhalla et al. (2002a,b), Naidu, (2004), Annamdas and Soh (2006a,b), and Yang et al.…”
Impedance-Based Structural Health Monitoring for Temperature Varying Applications.
PARK, G., KABEYA, K., CUDNEY, H. H., & INMAN, D. J. (1999) · JSME International Journal Series A · doi:10.1299/jsmea.42.249 · Cited by 284 · cited 1×
“The high-frequency range used for the EMI method has a number of advantages as outlined by Park et al. (1999, 2003b).”
Improving Accessibility of the Impedance-Based Structural Health Monitoring Method
Peairs, D. M., Park, G., & Inman, D. J. (2004) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x04039914 · Cited by 278 · cited 2×
“This was again a step ahead of previously developed strain measuring technique (Peairs et al., 2004a,b).”
PIEZOELECTRIC WAFER ACTIVE SENSORS
Giurgiutiu, V. (2008) · Structural Health Monitoring · doi:10.1016/b978-012088760-6.50008-8 · Cited by 275
Feasibility of using impedance‐based damage assessment for pipeline structures
Park, G., Cudney, H. H., & Inman, D. J. (2001) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.72 · Cited by 272 · cited 2×
“MFC actuators offer high performance and flexibility suitable for use in inflatable structures (Park et al., 2001b) or curvilinear surfaces as they are not as brittle as the PZT transducers.”
Structural Damage Detection Using a Minimum Rank Update Theory
Zimmerman, D. C., & Kaouk, M. (1994) · Journal of Vibration and Acoustics · doi:10.1115/1.2930416 · Cited by 265
Qualitative impedance-based health monitoring of civil infrastructures
Ayres, J. W., Lalande, F., Chaudhry, Z., & Rogers, C. A. (1998) · Smart Materials and Structures · doi:10.1088/0964-1726/7/5/004 · Cited by 232 · cited 1×
“The study was then extended to a large-scale prototype truss joint by Ayres et al. (1998).”
Electromechanical Impedance Modeling for Adhesively Bonded Piezo-Transducers
Bhalla, S., & Soh, C. K. (2004) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x04046309 · Cited by 231 · cited 5×
“The surface-bonded PZT transducer should have thin adhesive layer preferably one-third of the thickness of PZT transducer (Bhalla and Soh, 2004c).”
InfluentialSelf-citationGiurgiutiu, V., & Zagrai, A. (2005) · Structural Health Monitoring · doi:10.1177/1475921705049752 · Cited by 229 · cited 2×
“Similar neural network technique was presented by Giurgiutiu and Zagrai (2005).”
Xu, Y. G., & Liu, G. R. (2002) · Journal of Intelligent Material Systems and Structures · doi:10.1177/104538902761696733 · Cited by 172 · cited 1×
“Researchers (Xu and Liu, 2002; Bhalla and Soh, 2004a,b,c) have suggested that the PZT transducer should be bonded to the structure using an adhesive of high shear modulus and smallest practicable thickness.”
Yang, Y., Lim, Y. Y., & Soh, C. K. (2008) · Smart Materials and Structures · doi:10.1088/0964-1726/17/3/035008 · Cited by 162 · cited 5×
“It should also be kept away from atmospheric influences (like humidity, moisture, and temperature) (Yang et al., 2008a,b), acidic/alkaline attacks (due to rain or sea water exposures), and electrical or magnetic zone (Lin et al., 1988).”
InfluentialSelf-citationVictor Giurgiutiu, B., & Rogers, C. A. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.316923 · Cited by 158 · cited 2×
“These EMImodels were attempted for detection of external loadings on (Abe et al., 2000; Ong et al., 2002; Mall, 2002; Annamdas et al., 2007) and damages in the (Sun et al., 1995; Giurgiutiu and Rogers 1998; Yang et al., 2009) structures to be monitored.”
Piezoelectric Active Sensor Self-Diagnostics Using Electrical Admittance Measurements
Park, G., Farrar, C. R., Rutherford, A. C., & Robertson, A. N. (2006) · Journal of vibration and acoustics · doi:10.1115/1.2202157 · Cited by 156 · cited 1×
“The length and width influence the signature in horizontal plane, whereas thickness in vertical plane (Esteban, 1996; Park et al., 2006; Annamdas, 2007) of admittance signature.”
Yamashita, K., Katata, H., Okuyama, M., Miyoshi, H., Kato, G., Aoyagi, S., & Suzuki, Y. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(02)00037-7 · Cited by 152 · cited 2×
“The applications of PZT transducers are too abundant to list; however, they are mainly used in the fields of ultrasonics (Yamashita et al., 2002), noise and vibration control (Wu et al.”
Impedance-Based Structural Health Monitoring with Artificial Neural Networks
Lopes, V., Park, G., Cudney, H. H., & Inman, D. J. (2000) · Journal of Intelligent Material Systems and Structures · doi:10.1106/h0ev-7pwm-qyhw-e7vf · Cited by 142 · cited 2×
“Additionally, integration of EMI with genetic algorithm (Xu et al., 2004), neural network (Lopes et al., 2000) etc., can be useful in NDE applications.”
Local-area health monitoring of aircraft via piezoelectric actuator/sensor patches
Chaudhry, Z. A., Joseph, T., Sun, F. P., & Rogers, C. A. (1995) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.208264 · Cited by 133 · cited 2×
“…applications in real life structures even after its success in both laboratories and preliminary practical applications in aerospace (for example, Chaudhry et al., 1995 monitored a Piper Model 601P airplane) and civil structures (Yang et al. 2008a monitored an underground transit station in…”
Bhalla, S. (2004) · DR-NTU (Nanyang Technological University) · Cited by 115
Influence of loading on the electromechanical admittance of piezoceramic transducers
Annamdas, V. G. M., Yang, Y., & Soh, C. K. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/5/045 · Cited by 111 · cited 8×
“These EMImodels were attempted for detection of external loadings on (Abe et al., 2000; Ong et al., 2002; Mall, 2002; Annamdas et al., 2007) and damages in the (Sun et al., 1995; Giurgiutiu and Rogers 1998; Yang et al., 2009) structures to be monitored.”
InfluentialSelf-citationSohn, H., Park, H. W., Law, K. H., & Farrar, C. R. (2006) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x0606629 · Cited by 107 · cited 1×
“The restriction/control of actuation by such new generation transducers may be used to monitor the health of structures without the need for baseline signature (Sohn et al., 2007).”
Development of an extremely compact impedance-based wireless sensing device
Overly, T. G. S., Park, G., Farinholt, K. M., & Farrar, C. R. (2008) · Smart Materials and Structures · doi:10.1088/0964-1726/17/6/065011 · Cited by 100 · cited 1×
“In addition, they often have the benefit of being portable and more importantly can be implemented on a computer chip, which is about the size of a postage stamp, making it possible to implement the new system in the field (Overly et al., 2008).”
An outlier analysis framework for impedance-based structural health monitoring
Park, G., Rutherford, A. C., Hoon Sohn, A., & Farrar, C. R. (2004) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2004.10.013 · Cited by 93 · cited 1×
“Park et al. (2005) presented an outlier analysis framework for EMI to quantify damage.”
Health monitoring and active control of composite structures using piezoceramic patches
Schulz, M. J., Pai, P. F., & Inman, D. J. (1999) · Composites Part B Engineering · doi:10.1016/s1359-8368(99)00034-7 · Cited by 87 · cited 2×
“…(Crawley, 1984, Crawley and de Luis, 1987) demonstrated the use of smart PZT transducer for SHM and vibration control, this was later verified by many researchers in later decades (Crawley and Anderson, 1990; Mayne and Dosch, 1994; Wu et al., 1994; Schulz et al., 1999; Inman, 2001; Kim, 2002).”
Three-Dimensional Electromechanical Impedance Model. II: Damage Analysis and PZT Characterization
Annamdas, V. G. M., & Soh, C. K. (2006) · Journal of Aerospace Engineering · doi:10.1061/(asce)0893-1321(2007)20:1(63 · Cited by 43 · cited 2×
“…the PZT material during its life time, damping due to atmospheric factors like humidity, moisture and heat, acidic, or alkaline attacks from sea water exposure (Yang et al., 2008a,b), and presence of electrical or magnetic zone (Lin et al., 1988) near the PZT transducer (Annamdas and Soh, 2007a,b).”
Self-citationDesign of a wireless active sensing unit for structural health monitoring
Lynch, J. P., Sundararajan, A., Law, K. H., Hoon Sohn, A., & Farrar, C. R. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.545572 · Cited by 38 · cited 1×
“Sensitivity of the EMI technique to detect minor defects is also comparable to that of the ultrasonic methods; however, ultrasonic methods are unable to detect cracks perpendicular to the surface of wave propagation (Bechmann and Fair, 1958; Giurgiutiu and Rogers, 1997; Lynch et al., 2004).”
Analysis of the sensing region of a PZT actuator-sensor
Esteban, J. (1996) · VTechWorks (Virginia Tech) · Cited by 32
Feasibility of Using the Piezoelectric Properties of Wood for Structural Health Monitoring
Garza, C., Wheat, D. L., & Kallivokas, L. F. (2006) · ASCE Structures Congress · doi:10.1061/40889(201)89 · Cited by 4 · cited 3×
“, 2008), aerospace (Giurgiutiu, 2007; M7 aerospace service and innovative solutions for the aerospace industry, 2008), mechanical, medical, wooden (Gaza et al., 2006) and biological systems.”
Cited by
Piezoelectric Transducer-Based Structural Health Monitoring for Aircraft Applications
Qing, X., Li, W., Wang, Y., & Sun, H. (2019) · Sensors · doi:10.3390/s19030545 · Cited by 446
Sensors for process and structural health monitoring of aerospace composites: A review
Rocha, H., Semprimoschnig, C., & Nunes, J. P. (2021) · Engineering Structures · doi:10.1016/j.engstruct.2021.112231 · Cited by 368
Na, W. S., & Baek, J. (2018) · Sensors · doi:10.3390/s18051307 · Cited by 336
Structural Damage Detection Using a Minimum Rank Update Theory
Zimmerman, D. C., & Kaouk, M. (1994) · Journal of Vibration and Acoustics · doi:10.1115/1.2930416 · Cited by 265
Annamdas, V. G., & Radhika, M. A. (2013) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x13481254 · Cited by 176
“Furthermore, it should also work for wider frequency ranges so that the damage detection can be effective (Annamdas and Soh, 2010; Park et al., 2003; Park and Inman, 2007).”
BackgroundMethodSelf-citation
Metadata
- Authors
- Annamdas, V. G. M., & Soh, C. K.
- Venue
- Journal of Intelligent Material Systems and Structures
- Publisher
- SAGE Publications
- Published
- 2009-11-11
- Volume
- 21
- Issue
- 1
- Pages
- 41-59
- ISSN
- 1045-389X (ISSN-L)
- 1530-8138
- OpenAlex
- W2122912160
- Cited by
- 218
- References
- 42
- FWCI
- 7.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.