Adaptive Closed-Loop Control Provides Blood-Glucose Regulation Using Dual Subcutaneous Insulin and Glucagon Infusion in Diabetic Swine
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Background: In order to stave off deleterious complications of the disease, the ultimate task for people with diabetes is to maintain their blood glucose in euglycemic range. Despite technological advancements, conventional open-loop therapy often results in prolonged hyperglycemia and episodic hypoglycemia, in addition to necessitating carbohydrate counting, frequent glucose monitoring, and drug administration. The logical conclusion in the evolution of exogenous insulin therapy is to develop an automated closed-loop control system. Methods: Eleven closed-loop control experiments were conducted in four anesthetized diabetic pigs, with carbohydrate loads simulated by intravenous glucose administration through ear-vein catheters. Type 1 diabetes-like pathology was induced using intravenous administration of cytotoxin streptozotocin. The augmented model-predictive control algorithm accounts for the accumulation of subcutaneous insulin, which is critical in avoiding excessive insulin dosing. Results: Control results consistently showed successful blood-glucose regulation to euglycemic range within 80–120 minutes after intravenous glucose loads, with no incidence of hypoglycemia. This is consistent with a negative oral glucose tolerance test for diabetes and is the optimal postprandial regulation that can be achieved with subcutaneous insulin administration. Results also demonstrated the potency of subcutaneous glucagon in staving off episodic hypoglycemia and revealed efficacy of the control algorithm in coping with a twofold variation in subject weights, while simultaneously overlooking erratic blood-glucose fluctuations. Conclusions: Using an automated adaptive glucose-control system, we show successful blood-glucose regulation in vivo and establish, definitively, the plausibility and practicality of closed-loop blood-glucose control using subcutaneous insulin and glucagon infusion in type 1 diabetes. The control system strikes an intricate balance between tight blood-glucose control and optimal drug consumption, while simultaneously maintaining emphasis on simplicity and reliability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977
Model predictive control: Theory and practice—A survey
García, C. E., Prett, D. M., & Morari, M. (1989) · Automatica · doi:10.1016/0005-1098(89)90002-2 · Cited by 5,284
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Generalized predictive control—Part I. The basic algorithm
Clarke, D. W., Mohtadi, C., & Tuffs, P. S. (1987) · Automatica · doi:10.1016/0005-1098(87)90087-2 · Cited by 3,799
Ljung, L. (1999) · Wiley Encyclopedia of Electrical and Electronics Engineering · doi:10.1002/047134608x.w1046 · Cited by 3,778
Lee, J. H., Kaisare, N. S., & García, C. E. (2007) · Springer eBooks · doi:10.1002/9781394333325.fmatter · Cited by 3,766
Åström, K. J., & Wittenmark, B. (1973) · Automatica · doi:10.1016/0005-1098(73)90073-3 · Cited by 1,583
Generalized Predictive Control
Camacho, E. F., & Bordons, C. (2007) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-0-85729-398-5_4 · Cited by 916
Gerich, J. E., Langlois, M., Noacco, C., Karam, J. H., & Forsham, P. H. (1973) · Science · doi:10.1126/science.182.4108.171 · Cited by 688
Clarke, D. W., & Gawthrop, P. J. (1979) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1979.0145 · Cited by 612
A model-based algorithm for blood glucose control in Type I diabetic patients
Parker, R. S., Doyle, F. J., & Peppas, N. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740877 · Cited by 500
An Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Diabetes-Induced Accelerated Atherosclerosis in Swine
Gerrity, R. G., Natarajan, R., Nadler, J. L., & Kimsey, T. (2001) · Diabetes · doi:10.2337/diabetes.50.7.1654 · Cited by 270
The intravenous route to blood glucose control
Parker, R. S., Doyle, F. J., & Peppas, N. A. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.897829 · Cited by 236
Extended least squares and their applications to adaptive control and prediction in linear systems
Lai, T., & Wei, C.-Z. (1986) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1986.1104138 · Cited by 184
Implantable closed-loop glucose-sensing and insulin delivery: the future for insulin pump therapy
Renard, É. (2002) · Current Opinion in Pharmacology · doi:10.1016/s1471-4892(02)00216-3 · Cited by 171
Mini-Dose Glucagon Rescue for Hypoglycemia in Children With Type 1 Diabetes
Haymond, M. W., & Schreiner, B. (2001) · Diabetes Care · doi:10.2337/diacare.24.4.643 · Cited by 114
Advances Toward the Implantable Artificial Pancreas for Treatment of Diabetes
Jaremko, J., & Rorstad, O. (1998) · Diabetes Care · doi:10.2337/diacare.21.3.444 · Cited by 112
Feedback control dynamics for glucose controlled insulin infusion system.
Clemens, A. H. (1979) · PubMed · Cited by 95
Optimal insulin infusion resulting from a mathematical model of blood glucose dynamics
Fisher, M. E., & Teo, K. L. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.18755 · Cited by 89
Shichiri, M., Kawamori, R., Hakui, N., Yamasaki, Y., & Abe, H. (1984) · Diabetes · doi:10.2337/diab.33.12.1200 · Cited by 85
Marliss, E. B., Murray, F. T., Stokes, E. F., Zinman, B., Nakhooda, A. F., Denoga, A., Leibel, B. S., & Albisser, A. M. (1977) · Diabetes · doi:10.2337/diab.26.7.663 · Cited by 70
Does Physiological Blood Glucose Control Require an Adaptive Control Strategy?
Fischer, U., Schenk, W., Salzsieder, E., Albrecht, G., Abel, P., & Freyse, E.-J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326068 · Cited by 66
The Challenge of Type 1 Diabetes Mellitus
Eiselein, L., Schwartz, H. J., & Rutledge, J. (2004) · ILAR Journal · doi:10.1093/ilar.45.3.231 · Cited by 66
Further Results on Least Squares Based Adaptive Minimum Variance Control
Guo, L. (1994) · SIAM Journal on Control and Optimization · doi:10.1137/s0363012992229604 · Cited by 57
Plum, A., Agersø, H., & Andersen, L. (2000) · Drug Metabolism and Disposition · doi:10.1016/s0090-9556(24)15122-7 · Cited by 56
An adaptive plasma glucose controller based on a nonlinear insulin/glucose model
Candas, B., & Radziuk, J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284922 · Cited by 49
Insulin lispro: a fast-acting insulin analog.
Noble, S. L., Johnston, E., & Walton, B. (1998) · PubMed · Cited by 39
An Improved Control Algorithm for an Artificial B-Cell
Botz, C. K. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324639 · Cited by 38
Quinn, J. A., Snyder, S. L., Berghoff, J. L., Colombo, C. S., & Jacobi, J. (2006) · Pharmacotherapy The Journal of Human Pharmacology and Drug Therapy · doi:10.1592/phco.26.10.1410 · Cited by 32
Adaptive control of the human glucose-regulatory system
Pagurek, B., Riordon, J. S., & Mahmoud, S. A. (1972) · Medical & Biological Engineering & Computing · doi:10.1007/bf02477386 · Cited by 30
El-Khatib, F. H., Jiang, J., Gerrity, R. G., & Damiano, E. R. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.0006 · Cited by 29
Self-citationA Simulation Study on a Self-Tuning Portable Controller of Blood Glucose
Brunetti, P., Cobelli, C., Cruciani, P., Fabietti, P. G., Filippucci, F., Santeusanio, F., & Sarti, E. (1993) · The International Journal of Artificial Organs · doi:10.1177/039139889301600111 · Cited by 26
Balkin, M. S., Mascioli, C., Smith, V., Al-Nachawati, H., Mehrishi, S., Saydain, G., Slone, H., Alessandrini, J., & Brown, L. (2006) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.673 · Cited by 24
Optimal feedback glycaemia regulation in diabetics
Bellomo, G., Brunetti, P., Calabrese, G., Mazzotti, D., Sarti, E., & Vincenzi, A. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442800 · Cited by 22
Novel Control System for Blood Glucose Using a Model Predictive Method
Kan, S., Onodera, H., Furutani, E., Aung, T., Araki, M., Nishimura, H., Maetani, S., & Imamura, M. (2000) · ASAIO Journal · doi:10.1097/00002480-200011000-00004 · Cited by 14
Blood glucose regulation: an output feedback approach
Femat, R., & Ruiz-Velazquez, E. (2003) · The proceedings of the IEEE Conference on Control Applications/The proceedings of the ... IEEE Conference on Control Applications · doi:10.1109/cca.1999.801158 · Cited by 7
Research works printed but not linked: 9
- Eiselein L, 2004, LAR J., 45, 231
- Reckless J, 2004, Diabetes Primary Care., 6, 134
- Clemens AH, 1979, Med Prog Technol., 6, 91
- Femat R, 1999, Proc IEEE Intl Conf Control App., 1, 1290
- El-Khatib FH, 2005, System identification and adaptive closed-loop glucose control in a type 1 diabetic swine model [dissertation]
- 10.1016/0005-1098(87)90087-2 · DOI · Paper page
- 10.1016/0005-1098(89)90002-2 · DOI · Paper page
- Noble SL, 1998, Am Fam Physician., 57, 279
- 10.1089/dia.2006.0006 · DOI · Paper page
Cited by
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403
“For the mathematical formulation of the algorithm, see SM Notes 1 and 2 and (17, 18).”
BackgroundMethodResultInfluentialSelf-citationClosed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Diagnosis and management of pancreatic cystic neoplasms: current evidence and guidelines
van Huijgevoort, N. C. M., del Chiaro, M., Wolfgang, C. L., van Hooft, J. E., & Besselink, M. G. (2019) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-019-0195-x · Cited by 263
Metadata
- Authors
- El-Khatib, F. H., Jiang, J., & Damiano, E. R.
- Affiliations
- Boston University (US)
- Corresponding author
- Damiano, Edward R.
- ORCID
- Jiang, John
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2007-03
- Volume
- 1
- Issue
- 2
- Pages
- 181-192
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC2771467
- OpenAlex
- W2101160802
- Cited by
- 99
- References
- 39
- Citations by year
- 2025: 2 · 2024: 2 · 2022: 1 · 2021: 4 · 2020: 4 · 2019: 6 · 2018: 10 · 2017: 6 · 2016: 3 · 2015: 8 · 2014: 7 · 2013: 7 · 2012: 9
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Optimization
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Keywords
- closed-loop glucose control, type 1 diabetes, subcutaneous insulin infusion, model predictive control, adaptive control, blood glucose regulation, streptozotocin-induced diabetes, porcine model, hypoglycemia prevention, postprandial blood glucose
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.