Significant Insulin Dose Errors May Occur if Blood Glucose Results are Obtained from Miscoded Meters
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective: The objective of this study was to determine inaccuracies of miscoded blood glucose (BG) meters and potential errors in insulin dose based on values from these meters. Research Design: Fasting diabetic subjects at three clinical centers participated in a 2-hour meal tolerance test. At various times subjects' blood was tested on five BG meters and on a Yellow Springs Instruments laboratory glucose analyzer. Some meters were purposely miscoded. Using the BG values from these meters, along with three insulin dose algorithms, Monte Carlo simulations were conducted to generate ideal and simulated-meter glucose values and subsequent probability of insulin dose errors based on normal and empirical distribution assumptions. Results: Maximal median percentage biases of miscoded meters were +29% and −37%, while maximal median percentage biases of correctly coded meters were only +0.64% and −10.45% ( p = 0.000, χ 2 test, df = 1). Using the low-dose algorithm and the normal distribution assumption, the combined data showed that the probability of insulin error of ±1U, ±2, ±3, ±4, and ±5U for miscoded meters could be as high as 49.6, 50.0, 22.3, 1.4, and 0.04%, respectively. This is compared to manually, correctly coded meters where the probability of error of ±1, ±2, and ±3U could be as high as 44.6, 7.1, and 0.49%, respectively. There was no instance of a ±4 or ±5U insulin dose error with a manually, correctly coded meter. For autocoded meters, the probability of ±1 and ±2U could be as high as 35.4 and 1.4%, respectively. For autocoded meters there were no calculated insulin dose errors above ±2U. The probability of insulin misdosing with either manually, correctly coded or autocoded meters was significantly lower than that with miscoded meters. Results using empirical distributions showed similar trends of insulin dose errors. Conclusions: Blood glucose meter coding errors may result in significant insulin dosing errors. To avoid error, patients should be instructed to code their meters correctly or be advised to use an autocoded meter that showed superior performance over manually, correctly coded meters in this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Management of diabetes and hyperglycemia in hospitals.
Clement, S., Braithwaite, S. S., Magee, M. F., Ahmann, A., Smith, E. P., Schafer, R. G., Hirsch, I. B., & on behalf of the Diabetes in Hospitals Writing Committee (2004) · Diabetes Care · doi:10.2337/diacare.27.2.553 · Cited by 1,266
Skeie, S., Thue, G., Nerhus, K., & Sandberg, S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.7.994 · Cited by 131
Kristensen, G. B. B., Nerhus, K., Thue, G., & Sandberg, S. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.031575 · Cited by 68
Research works printed but not linked: 11
- 10.1373/clinchem.2004.033167 · DOI
- 10.1089/dia.2006.8.347 · DOI · Paper page
- 2004, Health Devices, 33, 251
- Alto WA, 2002, J Am Board Fam Pract., 15, 1
- 10.1177/014572170002600610 · DOI · Paper page
- 10.3928/0098-9134-19940201-04 · DOI
- 10.12968/bjon.1994.3.19.1021 · doi:10.12968/bjon.1994.3.19.1021
- 10.1177/014572170403000119 · DOI · Paper page
- 10.4158/EP.9.2.137 · DOI
- 10.1056/NEJMoa011300 · DOI · Paper page
- 10.1093/clinchem/47.2.209 · DOI · Paper page
Cited by
Factors affecting blood glucose monitoring: sources of errors in measurement
Ginsberg, B. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300438 · Cited by 348
Hijacking an insulin pump: Security attacks and defenses for a diabetes therapy system
Li, C., Raghunathan, A., & Jha, N. K. (2011) · 2011 IEEE 13th International Conference on e-Health Networking, Applications and Services · doi:10.1109/health.2011.6026732 · Cited by 324
Boettcher, C., Dost, A., Wudy, S. A., Flechtner-Mors, M., Borkenstein, M., Schiel, R., Weitzel, D., Bechtold-Dalla Pozza, S., Wolf, J., Holl, R. W., et al. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0262 · Cited by 35
Bailey, T., Wallace, J. F., Greene, C., Pardo, S., Brown, D., Pflug, B., & Klaff, L. J. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.06.001 · Cited by 14
Rao, A., Wiley, M., Iyengar, S., Nadeau, D., & Carnevale, J. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400118 · Cited by 12
Metadata
- Authors
- Raine, C. H., Schrock, L. E., Edelman, S. V., Mudaliar, S. R. D., Zhong, W., Proud, L. J., & Parkes, J. L.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2007-03
- Volume
- 1
- Issue
- 2
- Pages
- 205-210
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2156605723
- Cited by
- 43
- References
- 3
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Significant Insulin Dose Errors May Occur if Blood Glucose Results are Obtained from Miscoded Meters. https://app.cochat.ai/papers/10.1177/193229680700100211
- The paper
- Raine, C. H., Schrock, L. E., Edelman, S. V., Mudaliar, S. R. D., Zhong, W., Proud, L. J., & Parkes, J. L. (2007). Significant Insulin Dose Errors May Occur if Blood Glucose Results are Obtained from Miscoded Meters. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229680700100211
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.