Glucose Clamp Algorithms and Insulin Time-Action Profiles
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Motivation: Most current insulin pumps include an insulin-on-board (IOB) feature to help subjects avoid problems associated with “insulin stacking.” In addition, many control algorithms proposed for a closed-loop artificial pancreas make use of IOB to reduce the probability of hypoglycemic events that often occur due to the integral action of the controller. The IOB curves are generated from the pharmacodynamic (time-activity profiles) actions of subcutaneous insulin, which are obtained from glycemic clamp studies. Methods: Glycemic clamp algorithms are reviewed and in silico studies are performed to analyze the effect of glucose meter bias and noise on glycemic control and the manipulated glucose infusion rates. The glucose infusion rates are used to obtain insulin time-activity profiles, which are then used to generate IOB curves. Results: A model-based, three-step-ahead controller is shown to be equivalent to a proportional-integral control algorithm with time-delay compensation. A systematic glucose meter bias of +6 mg/dl results in a decrease in the glucose area under the curve of 3% but no change in the IOB profiles. Conclusions: Based on these preliminary simulation studies, a substantial amount of glucose meter bias and noise during a glycemic clamp can be tolerated with little net effect on the IOB curves. It is suggested that handheld glucose meters can therefore be used in clamp studies if the measurements are filtered (averaged) before processing by the control algorithm. Clinical studies are needed to confirm these preliminary results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Control engineering approaches have been applied to the glucose–insulin closed-loop system [99]”
From Health behavior models in the age of mobile interventions: are our theories up to the task? (2011) · cites this paper as [99]
Citations
Cites
Glucose clamp technique: a method for quantifying insulin secretion and resistance.
DeFronzo, R. A., Tobin, J. D., & Andres, R. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.237.3.e214 · Cited by 7,425
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Process Control: Modeling, Design and Simulation
Bequette, B. W. (2002) · Medical Entomology and Zoology · Cited by 815
Self-citationAn Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Mudaliar, S. R., Lindberg, F. A., Joyce, M., Beerdsen, P., Strange, P., Lin, A., & Henry, R. R. (1999) · Diabetes Care · doi:10.2337/diacare.22.9.1501 · Cited by 276
Clinical Control of Diabetes by the Artificial Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., Zingg, W., Schipper, H., & Gander, R. (1974) · Diabetes · doi:10.2337/diab.23.5.397 · Cited by 272
Insulin Control of Glucose Metabolism in Man
Insel, P. A., Liljenquist, J. E., Tobin, J. D., Sherwin, R. S., Watkins, P., Andres, R., & Berman, M. (1975) · Journal of Clinical Investigation · doi:10.1172/jci108006 · Cited by 244
Insulin Kinetics in Type-1 Diabetes: Continuous and Bolus Delivery of Rapid Acting Insulin
Wilinska, M. E., Chassin, L. J., Schaller, H. C., Schaupp, L., Pieber, T. R., & Hovorka, R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839639 · Cited by 237
Bolus Calculator: A Review of Four “Smart” Insulin Pumps
Zisser, H., Robinson, L., Bevier, W., Dassau, E., Ellingsen, C., Doyle, F. J., & Jovanovic, L. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0284 · Cited by 164
Heinemann, L., Weyer, C., Rauhaus, M., Heinrichs, S., & Heise, T. (1998) · Diabetes Care · doi:10.2337/diacare.21.11.1910 · Cited by 163
Ellingsen, C., Dassau, E., Zisser, H., Grosman, B., Percival, M. W., Jovanovič, L., & Doyle, F. J. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300319 · Cited by 153
Lee, H., & Bequette, B. W. (2009) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.03.002 · Cited by 115
Self-citationTime-Action Profiles of Novel Premixed Preparations of Insulin Lispro and NPL Insulin
Heise, T., Weyer, C., Serwas, A., Heinrichs, S., Osinga, J., Roach, P., Woodworth, J., Gudat, U., & Heinemann, L. (1998) · Diabetes Care · doi:10.2337/diacare.21.5.800 · Cited by 110
Feedback control dynamics for glucose controlled insulin infusion system.
Clemens, A. H. (1979) · PubMed · Cited by 95
Insulin glulisine: a faster onset of action compared with insulin lispro
Heise, T., Nosek, L., Spitzer, H., Heinemann, L., Niemöller, E., Frick, A. D., & Becker, R. H. A. (2007) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2007.00746.x · Cited by 90
Heise, T., Eckers, U., Kanc, K., Nielsen, J., & Nosek, L. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0019 · Cited by 54
Mathematical Modeling Research to Support the Development of Automated Insulin-Delivery Systems
Steil, G. M., & Reifman, J. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300223 · Cited by 50
Development of the Biostator Glucose clamping algorithm.
Clemens, A. H., Hough, D. L., & D'Orazio, P. A. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.9.1899 · Cited by 49
Ponchner, M., Heine, R. J., Pernet, A., Manning, I., Francis, A. J., Cook, D., Ørskov, H., & Alberti, K. G. M. M. (1984) · Diabetologia · doi:10.1007/bf00262213 · Cited by 41
An Analysis of How to Measure Glucose during Glucose Clamps: Are Glucose Meters Ready for Research?
Hompesch, M., & Rave, K. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200522 · Cited by 25
Development and testing of a simple algorithm for a glucose clamp
Furler, S. M., Zelenka, G. S., & Kraegen, E. W. (1986) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442689 · Cited by 19
A new glucose-clamp algorithm-theoretical considerations and computer simulations
Palazzo, P., & Viti, V. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55645 · Cited by 11
A new Glucose Clamp Algorithm: Clinical Validation
Campostano, A., Altomonte, F., Bessarione, D., Casu, M., Triolo, A., & Lamedica, G. (1991) · The International Journal of Artificial Organs · doi:10.1177/039139889101400711 · Cited by 5
FreeStyle Mini™ Blood Glucose Results Are Accurate and Suitable for Use in Glycemic Clamp Protocols
Cohen, O., Shaklai, S., Gabis, E., & Pani, M. A. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200521 · Cited by 5
Research works printed but not linked: 7
- Lee H, 2009, J Diabetes Sci Technol., 3, A101
- Walsh J, 2006, Pumping insulin.
- Heinemann L, 2004, Time-action profiles of insulin preparations
- DeFronzo RA, 1979, Am J Physiol., 237, E214
- Clemens AH, 1979, Med Prog Technol., 6, 91
- Bergman RN, 1979, Am J Physiol., 236, E667
- Lee H, Biomed Signal Process Control.
Cited by
Health behavior models in the age of mobile interventions: are our theories up to the task?
Riley, W. T., Rivera, D. E., Atienza, A. A., Nilsen, W., Allison, S. M., & Mermelstein, R. (2011) · Translational Behavioral Medicine · doi:10.1007/s13142-011-0021-7 · Cited by 978
Challenges and recent progress in the development of a closed-loop artificial pancreas
Bequette, B. W. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.007 · Cited by 183
“Finan, Zisser, Jovanovič, Bevier, and Seborg (2007), and Lee and Bequette (2009) show that even the sign of the gain between insulin and glucose concentration can be wrong; it should be negative, but identification techniques may yield a positive gain, due to the simultaneous effect of the meal.”
BackgroundInfluentialSelf-citationLee, S., Kim, J., Park, S. W., Jin, S., & Park, S. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3002022 · Cited by 108
Insulin Stacking Versus Therapeutic Accumulation: Understanding the Differences
Heise, T., & Meneghini, L. F. (2014) · Endocrine Practice · doi:10.4158/ep13090.ra · Cited by 87
Automatic regulatory control in type 1 diabetes without carbohydrate counting
Colmegna, P. H., Garelli, F., Battista, H. D., & Sánchez‐Peña, R. (2018) · Control Engineering Practice · doi:10.1016/j.conengprac.2018.02.003 · Cited by 81
Metadata
- Authors
- Bequette, B. W.
- Affiliations
- Rensselaer Polytechnic Institute (US)
- Corresponding author
- Bequette, B. Wayne
- ORCID
- Bequette, B. Wayne
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2009-09
- Volume
- 3
- Issue
- 5
- Pages
- 1005-1013
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC2769898
- OpenAlex
- W14770939
- Cited by
- 43
- References
- 25
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 1 · 2021: 5 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 3 · 2016: 1 · 2015: 1 · 2014: 4 · 2013: 5 · 2012: 3
- Type
- conference abstract
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Optimization
- Keywords
- insulin on board, glucose infusion rate, PI controller, time delay compensation, hypoglycemia
- MeSH terms
- Algorithms, Blood Glucose, Computer Simulation, Diabetes Mellitus, Equipment Design, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Models, Biological, Predictive Value of Tests, Reproducibility of Results, Glucose Clamp Technique, Pancreas, Artificial, Diagnostic Equipment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.