Glucose Clamp Algorithms and Insulin Time-Action Profiles
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Motivation: Most current insulin pumps include an insulin-on-board (IOB) feature to help subjects avoid problems associated with “insulin stacking.” In addition, many control algorithms proposed for a closed-loop artificial pancreas make use of IOB to reduce the probability of hypoglycemic events that often occur due to the integral action of the controller. The IOB curves are generated from the pharmacodynamic (time-activity profiles) actions of subcutaneous insulin, which are obtained from glycemic clamp studies. Methods: Glycemic clamp algorithms are reviewed and in silico studies are performed to analyze the effect of glucose meter bias and noise on glycemic control and the manipulated glucose infusion rates. The glucose infusion rates are used to obtain insulin time-activity profiles, which are then used to generate IOB curves. Results: A model-based, three-step-ahead controller is shown to be equivalent to a proportional-integral control algorithm with time-delay compensation. A systematic glucose meter bias of +6 mg/dl results in a decrease in the glucose area under the curve of 3% but no change in the IOB profiles. Conclusions: Based on these preliminary simulation studies, a substantial amount of glucose meter bias and noise during a glycemic clamp can be tolerated with little net effect on the IOB curves. It is suggested that handheld glucose meters can therefore be used in clamp studies if the measurements are filtered (averaged) before processing by the control algorithm. Clinical studies are needed to confirm these preliminary results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Control engineering approaches have been applied to the glucose–insulin closed-loop system [99]”
From Health behavior models in the age of mobile interventions: are our theories up to the task? (2011) · cites this paper as [99]
Citations
Cites
Glucose clamp technique: a method for quantifying insulin secretion and resistance.
DeFronzo, R. A., Tobin, J. D., & Andres, R. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.237.3.e214 · Cited by 7,425
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Process Control: Modeling, Design and Simulation
Bequette, B. W. (2002) · Medical Entomology and Zoology · Cited by 815
Self-citationAn Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Mudaliar, S. R., Lindberg, F. A., Joyce, M., Beerdsen, P., Strange, P., Lin, A., & Henry, R. R. (1999) · Diabetes Care · doi:10.2337/diacare.22.9.1501 · Cited by 276
Clinical Control of Diabetes by the Artificial Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., Zingg, W., Schipper, H., & Gander, R. (1974) · Diabetes · doi:10.2337/diab.23.5.397 · Cited by 272
Insulin Control of Glucose Metabolism in Man
Insel, P. A., Liljenquist, J. E., Tobin, J. D., Sherwin, R. S., Watkins, P., Andres, R., & Berman, M. (1975) · Journal of Clinical Investigation · doi:10.1172/jci108006 · Cited by 244
Insulin Kinetics in Type-1 Diabetes: Continuous and Bolus Delivery of Rapid Acting Insulin
Wilinska, M. E., Chassin, L. J., Schaller, H. C., Schaupp, L., Pieber, T. R., & Hovorka, R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839639 · Cited by 237
Bolus Calculator: A Review of Four “Smart” Insulin Pumps
Zisser, H., Robinson, L., Bevier, W., Dassau, E., Ellingsen, C., Doyle, F. J., & Jovanovic, L. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0284 · Cited by 164
Research works printed but not linked: 7
- Lee H, 2009, J Diabetes Sci Technol., 3, A101
- Walsh J, 2006, Pumping insulin.
- Heinemann L, 2004, Time-action profiles of insulin preparations
- DeFronzo RA, 1979, Am J Physiol., 237, E214
- Clemens AH, 1979, Med Prog Technol., 6, 91
- Bergman RN, 1979, Am J Physiol., 236, E667
- Lee H, Biomed Signal Process Control.
Cited by
Health behavior models in the age of mobile interventions: are our theories up to the task?
Riley, W. T., Rivera, D. E., Atienza, A. A., Nilsen, W., Allison, S. M., & Mermelstein, R. (2011) · Translational Behavioral Medicine · doi:10.1007/s13142-011-0021-7 · Cited by 978
Challenges and recent progress in the development of a closed-loop artificial pancreas
Bequette, B. W. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.007 · Cited by 183
“Finan, Zisser, Jovanovič, Bevier, and Seborg (2007), and Lee and Bequette (2009) show that even the sign of the gain between insulin and glucose concentration can be wrong; it should be negative, but identification techniques may yield a positive gain, due to the simultaneous effect of the meal.”
BackgroundInfluentialSelf-citationLee, S., Kim, J., Park, S. W., Jin, S., & Park, S. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3002022 · Cited by 108
Insulin Stacking Versus Therapeutic Accumulation: Understanding the Differences
Heise, T., & Meneghini, L. F. (2014) · Endocrine Practice · doi:10.4158/ep13090.ra · Cited by 87
Automatic regulatory control in type 1 diabetes without carbohydrate counting
Colmegna, P. H., Garelli, F., Battista, H. D., & Sánchez‐Peña, R. (2018) · Control Engineering Practice · doi:10.1016/j.conengprac.2018.02.003 · Cited by 81
Bondía, J., Romero‐Vivó, S., Ricarte, B., & Díez, J.-L. (2018) · IEEE Control Systems · doi:10.1109/mcs.2017.2766312 · Cited by 71
El Youssef, J., Castle, J. R., Bakhtiani, P. A., Haidar, A., Branigan, D. L., Breen, M., & Ward, W. K. (2014) · Diabetes Care · doi:10.2337/dc14-0803 · Cited by 52
Reinforcement Learning Models and Algorithms for Diabetes Management
Yau, K. A., Chong, Y.-W., Fan, X., Wu, C., Saleem, Y., & Lim, P.-C. (2023) · IEEE Access · doi:10.1109/access.2023.3259425 · Cited by 51
Modeling and control of pharmacodynamics
Beck, C. L. (2015) · European Journal of Control · doi:10.1016/j.ejcon.2015.04.006 · Cited by 47
Postprandial response improvement via safety layer in closed-loop blood glucose controllers
Vargas, F. M. L., Garelli, F., Battista, H. D., & Vehí, J. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.10.003 · Cited by 42
Artificial Neural Networks Based Controller for Glucose Monitoring during Clamp Test
Catalogna, M., Cohen, E., Fishman, S., Halpern, Z., Nevo, U., & Ben-Jacob, E. (2012) · PLoS ONE · doi:10.1371/journal.pone.0044587 · Cited by 41
Nguyen, T.-T. P., Jacobs, P. G., Castle, J. R., Wilson, L. M., Kuehl, K. S., Branigan, D. L., Gabo, V. B., Guillot, F. H., Riddell, M. C., Haidar, A., et al. (2020) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00534.2020 · Cited by 33
Continuous Glucose Monitoring Enables the Detection of Losses in Infusion Set Actuation (LISAs)
Howsmon, D., Cameron, F., Baysal, N., Ly, T., Forlenza, G., Maahs, D., Buckingham, B., Hahn, J., & Bequette, B. (2017) · Sensors · doi:10.3390/s17010161 · Cited by 27
Self-citationBhatia, A., Tawade, S., Mastim, M. A., Kitabi, E. N., Gopalakrishnan, M., Shah, M., Yeshamaina, S., Gobburu, J. V. S., Sahib, M. K., Thakur, D., et al. (2018) · Acta Diabetologica · doi:10.1007/s00592-018-1113-3 · Cited by 20
Progress in Development of an Artificial Pancreas
Klonoff, D. C., Cobelli, C., Kovatchev, B. P., & Zisser, H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300502 · Cited by 20
Piña, A., Holly, L. E., Zerr, A. A., & Rivera, D. E. (2014) · Journal of Clinical Child & Adolescent Psychology · doi:10.1080/15374416.2014.888667 · Cited by 19
Lee, J. J., Dassau, E., Zisser, H., Harvey, R. A., Jovanovic, L. G., & Doyle, F. J. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700127 · Cited by 18
Resalat, N., Youssef, J. E., Reddy, R., & Jacobs, P. G. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.2270 · Cited by 15
Challenges and progress in the development of a closed-loop artificial pancreas
Bequette, B. W. (2012) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2012.6315593 · Cited by 15
Self-citationUse of Automated Bolus Calculators for Diabetes Management
Schwartz, F., & Marling, C. R. (2010) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2013.09.02.92 · Cited by 11
Young, G. M., Jacobs, P. G., Tyler, N. S., Nguyen, T.-T. P., Castle, J. R., Wilson, L. M., Branigan, D. L., Gabo, V. B., Guillot, F. H., Riddell, M. C., et al. (2023) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00298.2022 · Cited by 9
Liu, H., Li, T., Yu, H., Li, J., Tan, H., & Yu, Y. (2022) · Frontiers in Pharmacology · doi:10.3389/fphar.2022.899798 · Cited by 9
Tao, Y., Zhu, M., Pu, J., Zhang, P., Wan, L., & Tang, C. (2021) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.786613 · Cited by 9
Liu, H., Yu, H., Sun, L., Qiao, J., Wan, S., Li, S., Li, J., Tan, H., & Yu, Y. (2021) · Scientific Reports · doi:10.1038/s41598-021-88782-8 · Cited by 7
Bequette, B. W., Cameron, F. M., Baysal, N., Howsmon, D. P., Buckingham, B. A., Maahs, D. M., & Levy, C. J. (2016) · Processes · doi:10.3390/pr4040039 · Cited by 6
Self-citationPrecision and accuracy of hyperglycemic clamps in a multicenter study
Mather, K. J., Tjaden, A. H., Hoehn, A., Nadeau, K. J., Buchanan, T. A., Kahn, S. E., Arslanian, S. A., Caprio, S., Atkinson, K. M., Cree‐Green, M., et al. (2021) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00598.2020 · Cited by 5
Ranjan, A. G., Wendt, S. L., Schmidt, S., Madsbad, S., Holst, J. J., Madsen, H., Knudsen, C., Jørgensen, J. B., & Nørgaard, K. (2017) · Basic & Clinical Pharmacology & Toxicology · doi:10.1111/bcpt.12907 · Cited by 5
100 Years of insulin: A chemical engineering perspective
Bequette, B. W. (2023) · Korean Journal of Chemical Engineering · doi:10.1007/s11814-022-1308-8 · Cited by 3
Self-citationChang, Y. C., & Jusko, W. J. (2025) · The Journal of Clinical Pharmacology · doi:10.1002/jcph.70010 · Cited by 2
Antwerp, B. V. (2014) · Wiley eBooks · doi:10.1002/9781118903681.ch6 · Cited by 2
Liu, H., Li, T., Yu, H., Chen, X., Li, J., Tan, H., & Yu, Y. (2025) · Clinical Pharmacokinetics · doi:10.1007/s40262-025-01590-5 · Cited by 1
Automated Insulin Dosing for Type 1 Diabetes
Bequette, B. W. (2021) · Springer eBooks · doi:10.1007/978-3-030-44184-5_100131 · Cited by 1
Self-citationDongre, S. A., Kulkarni, G. A., Thapa, D., Ghade, N. S., Lona, J., Prajapati, H. K., Mehta, H., Guttikar, S., Krishnan, A. R., & Sonar, S. M. (2025) · Clinical Pharmacology in Drug Development · doi:10.1002/cpdd.1510 · Cited by 1
Use of Automated Bolus Calculators for Diabetes Management
Schwartz, F., & Marling, C. R. (2013) · US Endocrinology · doi:10.17925/use.2013.09.02.124 · Cited by 1
Reminding Me of the Future: Episodic Future Thinking as A Strategy for Mobile Health Interventions
Qin, Y. (2021) · University Libraries (University of Maryland) · doi:10.13016/r1ko-24nw · Cited by 1
Modelling the Molecular Transportation of Subcutaneously Injected Salubrinal
Chen, A. B., Zhang, P., Duan, Z., Wang, G., & Yokota, H. (2011) · Biomedical Engineering and Computational Biology · doi:10.4137/becb.s7050 · Cited by 1
Strategies to mitigate hypoglycaemia in the artificial pancreas
Bondía, J., & Vehí, J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815655-1.00018-1
Computer simulation model and automatic control of glucose clamp
Maghoul, P. (2021) · eScholarship@McGill (McGill) · doi:10.82308/47829
Liu, H., Li, T., Chen, X., Yu, H., Men, Y., Tan, H., Li, J., & Yu, Y. (2026) · Pharmaceutics · doi:10.3390/pharmaceutics18091051
Practicable Measures and Indices of Insulin Resistance in Nutrition Research
Hattersley, J. G., & Weickert, M. O. (2013) · Current Obesity Reports · doi:10.1007/s13679-013-0071-x
Automated Insulin Dosing for Type 1 Diabetes
Bequette, B. W. (2019) · Springer eBooks · doi:10.1007/978-1-4471-5102-9_100131-1
Self-citationControlling Human Physiology via Drugs and Devices
Hahn, J., & Howsmon, D. P. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-14081-5.00009-x
Reinforcement and federated learning for privacy-preserving glucose regulation: A review
Abdelfattah, S., Karma, R. B., Karma, R. B., & Baniya, B. K. (2026) · Artificial Intelligence in Health · doi:10.36922/aih026050010
Liu, H., Li, T., Chen, X., Yu, H., & Yu, Y. (2025) · World Journal of Diabetes · doi:10.4239/wjd.v16.i2.101779
Bhatia, A., Tawade, S., Mastim, M. A., Kitabi, E. N., Gopalakrishnan, M., Shah, M. A., Yeshamaina, S., Gobburu, J. V. S., Sahib, M. K., Thakur, D., et al. (2020) · Acta Diabetologica · doi:10.1007/s00592-020-01617-2
Metadata
- Authors
- Bequette, B. W.
- Affiliations
- Rensselaer Polytechnic Institute (US)
- Corresponding author
- Bequette, B. Wayne
- ORCID
- Bequette, B. Wayne
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2009-09
- Volume
- 3
- Issue
- 5
- Pages
- 1005-1013
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC2769898
- OpenAlex
- W14770939
- Cited by
- 43
- References
- 25
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 1 · 2021: 5 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 3 · 2016: 1 · 2015: 1 · 2014: 4 · 2013: 5 · 2012: 3
- Type
- conference abstract
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Optimization
- Keywords
- insulin on board, glucose infusion rate, PI controller, time delay compensation, hypoglycemia
- MeSH terms
- Algorithms, Blood Glucose, Computer Simulation, Diabetes Mellitus, Equipment Design, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Models, Biological, Predictive Value of Tests, Reproducibility of Results, Glucose Clamp Technique, Pancreas, Artificial, Diagnostic Equipment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.