Closed-Loop Artificial Pancreas Using Subcutaneous Glucose Sensing and Insulin Delivery and a Model Predictive Control Algorithm: The Virginia Experience
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Recent progress in the development of clinically accurate continuous glucose monitors (CGMs), automated continuous insulin infusion pumps, and control algorithms for calculating insulin doses from CGM data have enabled the development of prototypes of subcutaneous closed-loop systems for controlling blood glucose (BG) levels in type 1 diabetes. The use of a new personalized model predictive control (MPC) algorithm to determine insulin doses to achieve and maintain BG levels between 70 and 140 mg/dl overnight and to control postprandial BG levels is presented. METHODS: Eight adults with type 1 diabetes were studied twice, once using their personal open-loop systems to control BG overnight and for 4 h following a standardized meal and once using a closed-loop system that utilizes the MPC algorithm to control BG overnight and for 4 h following a standardized meal. Average BG levels, percentage of time within BG target of 70-140 mg/dl, number of hypoglycemia episodes, and postprandial BG excursions during both study periods were compared. RESULTS: With closed-loop control, once BG levels achieved the target range (70-140 mg/dl), they remained within that range throughout the night in seven of the eight subjects. One subject developed a BG level of 65 mg/dl, which was signaled by the CGM trend analysis, and the MPC algorithm directed the discontinuance of the insulin infusion. The number of overnight hypoglycemic events was significantly reduced (p = .011) with closed-loop control. Postprandial BG excursions were similar during closed-loop and open-loop control. CONCLUSION: Model predictive closed-loop control of BG levels can be achieved overnight and following a standardized breakfast meal. This "artificial pancreas" controls BG levels as effectively as patient-directed open-loop control following a morning meal but is significantly superior to open-loop control in preventing overnight hypoglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Meal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Self-citationWeinzimer, S. A., Steil, G. M., Swan, K. L., Dziura, J., Kurtz, N., & Tamborlane, W. V. (2008) · Diabetes Care · doi:10.2337/dc07-1967 · Cited by 567
Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473
Model Predictive Control of Type 1 Diabetes: An in Silico Trial
Magni, L., Raimondo, D. M., Bossi, L., Dalla Man, C., De Nicolao, G., Kovatchev, B., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100603 · Cited by 317
Self-citationGIM, Simulation Software of Meal Glucose–Insulin Model
Dalla Man, C., Raimondo, D. M., Rizza, R. A., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100303 · Cited by 253
Model-based blood glucose control for type 1 diabetes via parametric programming
Dua, P., Doyle, F. J., & Pistikopoulos, E. N. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.878075 · Cited by 198
The development of Biostator, a Glucose Controlled Insulin Infusion System (GCIIS).
Clemens, A. H., Chang, P. H., & Myers, R. W. (1977) · PubMed · Cited by 191
Detection of a Meal Using Continuous Glucose Monitoring
Dassau, E., Bequette, B. W., Buckingham, B. A., & Doyle, F. J. (2008) · Diabetes Care · doi:10.2337/dc07-1293 · Cited by 143
Cited by
Items 101–199 of 199
Artificial Pancreas Systems: An Integrated Multivariable Adaptive Approach
Turksoy, K., Quinn, L. T., Littlejohn, E., & Çınar, A. (2014) · IFAC Proceedings Volumes · doi:10.3182/20140824-6-za-1003.00815 · Cited by 18
“Model-predictive controllers (MPC) used in vivo (Bruttomesso et al., 2009; Clarke et al., 2009; Breton et al., 2012) needed modification of model parameters for different patients in these studies.”
Lee, J. J., Dassau, E., Zisser, H., Harvey, R. A., Jovanovic, L. G., & Doyle, F. J. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700127 · Cited by 18
Continuous Glucose Monitoring and Trend Accuracy: News About a Trend Compass
Signal, M., Gottlieb, R., Compte, A. L., & Chase, J. G. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814533091 · Cited by 17
“Several pilot studies have investigated closed loop control in people with diabetes [10-12], but the methods are still being developed and it is not used as a standard therapy.”
BackgroundHerrero, P., El-Sharkawy, M., Daniels, J., Jugnee, N., Uduku, C. N., Reddy, M., Oliver, N. S., & Georgiou, P. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819881456 · Cited by 17
Diabetes - Damages and Treatments
Rigobelo, E. C. (2011) · InTech eBooks · doi:10.5772/1823 · Cited by 17
Diabetes Technology: Monitoring, Analytics, and Optimal Control
Kovatchev, B. P. (2018) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a034389 · Cited by 17
“During 2008 – 2012, promising results were re-ported by several groups (Weinzimer et al. 2008; Bruttomesso et al. 2009; Clarke et al. 2009; El-Khatib et al. 2010; Hovorka et al. 2010, 2011; Renard et al. 2010; Zisser et al. 2011, 2014; Bre-ton et al. 2012; Russell et al. 2012; Luijf et al. 2013;…”
BackgroundSelf-citationArtificial Pancreas System for Type 1 Diabetes—Challenges and Advancements
Kapil, S., Saini, R., WANGNOO, S. K., & Dhir, S. (2020) · Exploratory Research and Hypothesis in Medicine · doi:10.14218/erhm.2020.00028 · Cited by 16
Messer, L. H., Berget, C., Ernst, A., Towers, L., Slover, R. H., & Forlenza, G. P. (2021) · Pediatric Diabetes · doi:10.1111/pedi.13183 · Cited by 16
Clinical Requirements for Closed-Loop Control Systems
Clarke, W. L., & Renard, É. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600233 · Cited by 16
Self-citationChallenges and progress in the development of a closed-loop artificial pancreas
Bequette, B. W. (2012) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2012.6315593 · Cited by 15
Automated Insulin Delivery—The Light at the End of the Tunnel
Turksoy, K., Frantz, N., Quinn, L., Dumin, M., Kilkus, J. M., Hibner, B. A., Çınar, A., & Littlejohn, E. (2017) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2017.02.055 · Cited by 14
Quiroz, G., Flores‐Gutiérrez, C., & Femat, R. (2011) · Optimal Control Applications and Methods · doi:10.1002/oca.989 · Cited by 14
Favero, S. D., Pillonetto, G., Cobelli, C., & Nicolao, G. D. (2011) · IFAC Proceedings Volumes · doi:10.3182/20110828-6-it-1002.01929 · Cited by 12
Propuesta de un algoritmo de control en lazo cerrado para la diabetes tipo 1
Rodríguez-Herrero, A. (2010) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.3681 · Cited by 12
Deployment of modular MPC for type 1 diabetes control: the Italian experience 2008–2016
Favero, S. D., Toffanin, C., Magni, L., & Cobelli, C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815655-1.00016-8 · Cited by 11
Artificial pancreas systems: experiences from concept to commercialisation
Rodríguez-Sarmiento, D. L., Vargas, F. M. L., & Maira, G. (2022) · Expert Review of Medical Devices · doi:10.1080/17434440.2022.2150546 · Cited by 11
“performance limitations against postprandial hyperglycemic events were found [77].”
BackgroundArtificial pancreas for type 1 diabetes: Closed-loop algorithm based on Error Dynamics Shaping
Cormerais, H., & Richard, P.-Y. (2012) · Journal of Process Control · doi:10.1016/j.jprocont.2012.05.008 · Cited by 11
Nonlinear glucose–insulin control considering delays—Part II: Control algorithm
Mythreyi, K., Subramanian, S. C., & Kumar, R. K. (2014) · Control Engineering Practice · doi:10.1016/j.conengprac.2014.02.012 · Cited by 11
Sanz, A. J. L., Rossetti, P., Ampudia‐Blasco, F. J., Vehí, J., & Bondía, J. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2012.12.003 · Cited by 11
Recent Advances in the Prevention of Hypoglycemia in Type 1 Diabetes
Realsen, J., & Chase, H. P. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0150 · Cited by 10
Real-Time Insulin Bolusing for Unannounced Meals Using CGM Measurements
Turksoy, K., & Çınar, A. (2015) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2015.10.142 · Cited by 10
Integrating Compartment Models with Recursive System Identification
Hajizadeh, I., Rashid, M. M., & Çınar, A. (2018) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2018.8431822 · Cited by 10
“Various control techniques are proposed in literature to maintain homeostasis and BGC near normal levels (80 − 140 mg/dL) [1]–[13].”
BackgroundAll Insulin Pumps Are Not Equivalent: A Bench Test Assessment for Several Basal Rates
Girardot, S., Jacquemier, P., Mousin, F., Rendekeu, C., Hardy, S., & Riveline, J. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0486 · Cited by 10
“Moreover, the standard does not include compulsory testing for the lowest BR, 12–16 although CSII are commonly used in both the pediatric population 17,18 and CLS. 19,20 In this context, as previously suggested by Heinemann et al., 13 the available evidence on the safety and efficacy of CSII remains limited.”
Automated closed-loop insulin delivery: system components, performance, and limitations
Rashid, M. M., Hajizadeh, I., Samadi, S., Sevil, M., Hobbs, N., Brandt, R., & Çınar, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816714-4.00015-6 · Cited by 9
Modern clinical management helps reducing the impact of type 1 diabetes in children
Scaramuzza, A. E., & Zuccotti, G. (2015) · Pharmacological Research · doi:10.1016/j.phrs.2015.03.001 · Cited by 9
Garcia‐Tirado, J., Colmegna, P. H., Corbett, J. P., Özaslan, B., & Breton, M. D. (2019) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2019.8814728 · Cited by 9
Self-citationRevert, A., Rossetti, P., Calm, R., Vehí, J., & Bondía, J. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400617 · Cited by 9
Diabetes Technology Meeting 2020
Shang, T., Zhang, J. Y., Bequette, B. W., Raymond, J. K., Coté, G. L., Sherr, J. L., Castle, J. R., Pickup, J. C., Pavlovic, Y., Espinoza, J., et al. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211016480 · Cited by 9
“102,103 A second approach would be to innovate on rapid acting insulin delivery with faster PK/PD profiles.”
BackgroundModelling the effect of insulin on the disposal of meal-attributable glucose in type 1 diabetes
García-García, F., Hovorka, R., Wilinska, M. E., Elleri, D., & Hernando, M. E. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1509-6 · Cited by 8
“Concerning applicability, the mechanistic model derived here could be integrated into the in silico metabolic simulation of meals [1, 6, 11, 19, 24, 30], in order to optimize postprandial insulin infusion regimes.”
MethodThe significance of LPV modeling of a widely used T1DM model
Szalay, P., Eigner, G., Kozlovszky, M., Rudas, I. J., & Kovács, L. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610304 · Cited by 8
Therapies for Type 1 Diabetes: Is a Cure Possible?
Chuzho, N., Mishra, N., Tandon, N., & Kumar, N. (2022) · Current Diabetes Reviews · doi:10.2174/1573399819666221202161259 · Cited by 7
Blood glucose regulation using a neural network predictor with a fuzzy logic controller
Allam, F., Nossair, Z., Gomma, H. W., Ibrahim, I., & Abdelsalam, M. (2013) · Journal of Intelligent & Fuzzy Systems · doi:10.3233/ifs-120648 · Cited by 6
Modified control algorithms for patients with type 1 diabetes mellitus undergoing exercise
Liu, S.-W., Huang, H., Lin, C.-H., & Chien, I. (2014) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2014.06.005 · Cited by 6
Hypoglycemia Prevention in Closed-Loop Artificial Pancreas for Patients with Type 1 Diabetes
Abu-Rmileh, A., & García-Gabín, W. (2011) · InTech eBooks · doi:10.5772/22647 · Cited by 6
“…artificial pancreas systems and their advantage over conventional treatment has been proved in several clinical studies (Atlas et al. (2010); Clarke et al. (2009); Hovorka et al. (2010); Steil et al. (2011; 2006); Weinzimer et al. (2008)), and a wide spectrum of control algorithms has been…”
BackgroundMethodContinuous Glucose Monitoring and Tight Glycaemic Control in Critically Ill Patients
Signal, M. (2013) · UC Research Repository (University of Canterbury) · doi:10.26021/3559 · Cited by 6
Automated optimal glycaemic control using a physiology based pharmacokinetic, pharmacodynamic model
Schaller, S., Schuppert, A., & Mitsos, A. (2015) · RWTH Publications (RWTH Aachen) · Cited by 6
Ensuring Stability and Fidelity of Recursively Identified Control-Relevant Models
Hajizadeh, I., Rashid, M. M., & Çınar, A. (2018) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2018.09.075 · Cited by 5
Design of dual hormone blood glucose therapy and comparison with single hormone using MPC algorithm
Dias, C. C., Kamath, S. R., & Vidyasagar, S. (2020) · IET Systems Biology · doi:10.1049/iet-syb.2020.0053 · Cited by 5
Closing the Loop: Another Step Forward
Weinstock, R. S. (2011) · Diabetes Care · doi:10.2337/dc11-1217 · Cited by 5
“Pilot closed-loop feasibility studies lasting up to 24 h have reported promising results in lessening hypoglycemia (6,10,12,19).”
BackgroundDias, C. C., Kamath, S. R., & Vidyasagar, S. (2019) · Amity International Conference on Artificial Intelligence (AICAI) · doi:10.1109/aicai.2019.8701401 · Cited by 4
Mei, Y., Huynh, T., Khor, R., & Rollins, D. K. (2019) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.4043335 · Cited by 4
Automated insulin delivery systems for people with type 1 diabetes
Sevil, M., Rashid, M. M., Hajizadeh, I., Askari, M. R., Hobbs, N., Brandt, R., Park, M., Quinn, L., & Çınar, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819838-4.00027-4 · Cited by 4
Hybrid Closed-Loop Insulin Delivery Systems for People With Type 1 Diabetes
Service, C. H. T. A. (2021) · Canadian Journal of Health Technologies · doi:10.51731/cjht.2021.50 · Cited by 4
Challenges and Opportunities in Design of Control Algorithm for Artificial Pancreas
Ghorbani, M., & Bogdan, P. (2014) · DROPS (Schloss Dagstuhl – Leibniz Center for Informatics) · doi:10.4230/oasics.mcps.2014.49 · Cited by 4
Automatic Glycemia Regulation of Type I Diabetes
MohammadRidha, T. (2017) · theses.fr (ABES) · doi:10.70675/c8095ce6z5ef9z48edz90faz7d0b926f23a3 · Cited by 4
Forlenza, G. P., Tabatabai, I., & Lewis, D. M. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0073 · Cited by 3
Ferguson, A. M., & Lin, A. C. (2024) · Annals of Biomedical Engineering · doi:10.1007/s10439-024-03529-6 · Cited by 3
Pilot Study of a Prototype Minimally Invasive Intradermal Continuous Glucose Monitor
Weinstock, R. S., Bristol, S., Armenia, A., Gesswein, A. C., Bequette, B. W., & Willis, J. P. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600627 · Cited by 3
Overcoming control challenges in the Artificial Pancreas
Hachimi, M. E., Ballouk, A., & Lebbar, H. (2016) · International Conference on Intelligent Systems: Theories and Applications · doi:10.1109/sita.2016.7772321 · Cited by 3
“In 2009 research efforts presented in [32] were the first clinical investigation of linear model predictive algorithms in artificial pancreas that reported the superiority of using this approach over PID controller.”
MethodManrique-Córdoba, J., Romero-Ante, J. D., Albán, Ó. A. V., Vicente-Samper, J. M., & Sabater-Navarro, J. M. (2020) · Revista Iberoamericana de Automática e Informática Industrial RIAI · doi:10.4995/riai.2019.11161 · Cited by 3
“…et al., 2010), (Steil et al., 2011), (Weinzimer et al., 2012), control basado en modelo y predictivo de modelo (MPC) (Bruttomesso et al., 2009), (Clarke et al., 2009), (Breton et al., 2012), control por lógica difusa (Nimri et al., 2012), (Mauseth et al., 2013) y control adaptativo (Turksoy…”
BackgroundArtificial Pancreas: A Review of Fundamentals and Inpatient and Outpatient Studies
Favero, S. D., Bruttomesso, D., & Cobelli, C. (2014) · Frontiers in diabetes · doi:10.1159/000363512 · Cited by 3
Toward Automation of Insulin Delivery - Management Solutions for Type 1 Diabetes
Nimri, R., & Phillip, M. (2015) · Endocrine development · doi:10.1159/000439321 · Cited by 3
Continuous monitoring blood glucose level in clinical practice and new methods for its analysis
Dreval', A. V., Dreval, O., & Starostina, E. G. (2013) · Problems of Endocrinology · doi:10.14341/probl201359441-49 · Cited by 3
“По отношению к суточной амплитуде колебаний изменение гликемии за 5 мин оказывается незначительным и потому кривая гликемии условно считается непрерывной [20].”
Insulin Pumps and Artificial Pancreas
Taleb, N., Gingras, V., & RABASA-LHORET, R. P. R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.65407-7 · Cited by 3
Abu-Rmileh, A. (2013) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 3
Sawyer, A., Forlenza, G. P., & Wadwa, R. P. (2025) · Expert Review of Medical Devices · doi:10.1080/17434440.2025.2585061 · Cited by 2
“BG patterns over-night and after breakfast were compared and found a reduction in overnight hypoglycemia on the MPC algorithm and similar post-prandial BG in both systems [51].”
Davis, G. M., Forlenza, G. P., Gehr, B., Pemberton, J. S., Penfornis, A., Do, D., Huyett, L. M., & Ly, T. T. (2026) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2026.113450 · Cited by 2
Adaptive control of artificial pancreas systems for treatment of type 1 diabetes
Hajizadeh, I., Askari, M. R., Sevil, M., Hobbs, N., Brandt, R., Rashid, M. M., & Çınar, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-821350-6.00003-2 · Cited by 2
A Novel Index to Evaluate the Blood Glucose Controllability of Type I Diabetic Patients
Campetelli, G., Musulin, E., BASUALDO, M. S., & Rigalli, A. (2011) · IFAC Proceedings Volumes · doi:10.3182/20110828-6-it-1002.03627 · Cited by 2
“Lately, the Juvenile Diabetes Research Foundation (JDRF) Artificial Pancreas Project, a consortium of groups, has been doing clinical trials at different institutions like University of Virginia (Clarke et al., 2009) to accelerate the development of the so dreamed artificial pancreas.”
BackgroundProgress with Closed-loop Systems in Type 1 Diabetes
Leelarathna, L., & Hovorka, R. (2010) · US Endocrinology · doi:10.17925/use.2010.06.1.58 · Cited by 2
IMPLANTABLE BIOSENSORS FOR PHYSIOLOGIC STATUS MONITORING DURING HEMORRHAGE
Kotanen, C. N. (2013) · TigerPrints (Clemson University) · Cited by 2
K, R. K., Narayanan, S., & Sivakumaran, N. (2022) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-6684-5092-5.ch014 · Cited by 1
Saliva Glucose Determination by Biosensor: Method Comparison to Chemiluminescence Immunoassay
Şemsi, R., Kökbaş, U., Arslan, B., Ergünol, E., Dinçel, A. S., & Kayrın, L. (2024) · Biochemistry (Moscow) Supplement Series B Biomedical Chemistry · doi:10.1134/s1990750824600286 · Cited by 1
“Innovative devices like iQuickit and iBGStar have been developed for transferring data to mobile devices, enhancing the usability of salivary glucose measurements [14, 15].”
A new closed-loop strategy for the treatment of type 1 diabetes based on Error Dynamics Shaping
Cormerais, H., Richard, P.-Y., Poirier, J. Y., & Guilhem, I. (2011) · IFAC Proceedings Volumes · doi:10.3182/20110828-6-it-1002.01436 · Cited by 1
Bondía, J., Sanz, A. J. L., Rossetti, P., Ampudia‐Blasco, F. J., & Vehí, J. (2011) · IFAC Proceedings Volumes · doi:10.3182/20110828-6-it-1002.02006 · Cited by 1
“…postprandial glucose control (after meals) is one of the biggest challenges found not only in current open-loop strategies, but also in closedloop control as demonstrated by clinical results of artificial pancreas prototypes (Bruttomesso et al., 2009; Clarke et al., 2009; Hovorka et al., 2010).”
BackgroundLiquid Metal Enabled Wearable Electronics
Liu, J., & Yi, L. (2018) · Springer series in biomaterials science and engineering · doi:10.1007/978-981-10-5607-9_14 · Cited by 1
Rollins, D. K. (2021) · IntechOpen eBooks · doi:10.5772/intechopen.99340 · Cited by 1
“FFPC is now evaluated on the in silico continuous stirred tank reactor (CSTR) in Figure 7 and described in [13] and taken from [5] with some minor modifications.”
MethodAutomated Glucose Control: A Review
Bhat, O., Khan, D. A., & Yousuf, R. (2021) · International Journal of E-Health and Medical Communications · doi:10.4018/ijehmc.20211101.oa12 · Cited by 1
Comparing Closed-loop Control of Drug Infusion using MPC and PID
Setati, T., Perold, W. J., Fourie, P., & Withey, D. (2022) · International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC) · doi:10.5220/0010783700003123 · Cited by 1
“…infusion systems, it was proven that MPC closed-loop control systems are more efficient than the standard open-loop infusion of insulin, and that patients’ in- sulin levels remained within the set-point range more often than in the open-loop case (Clarke et al., 2009) (Bruttomesso et al., 2009).”
BackgroundMethodInfluentialTechnological advances in pregnancy complicated by type 1 diabetes
Murphy, H. R., Elleri, D., Kumareswaran, K., & Hovorka, R. (2011) · Practical Diabetes · doi:10.1002/pdi.1568 · Cited by 1
Uncertainty in Postprandial Model Identification in type 1 Diabetes
Sanz, A. J. L. (2014) · RiuNet (Universitat Politècnica de València) · doi:10.4995/thesis/10251/37191 · Cited by 1
“published a study on 20 T1DM patients using an MPC controller tuned with the UVA simulator [62] [15].”
BackgroundMethodGessner, A. E. (2012) · doi:10.18130/v32w99 · Cited by 1
Brahim, N. B. (2016) · theses.fr (ABES) · doi:10.70675/3935a360zf8a8z49e0z91f8z2d19a0fb1187 · Cited by 1
“! ! in the UVA system [120],[121], the insulin delivery is in inverse proportion to the predicted risk for hypoglycemia using a T1D physiological model to estimate the patient’s metabolic state.”
MethodFrayne, M. C. H. (2024) · doi:10.11575/prism/46544 · Cited by 1
Pirog, A. (2017) · theses.fr (ABES) · doi:10.70675/1e7796a6z2caaz44f1z915azf222f6adf1d6 · Cited by 1
In Vitro and in Silico approach of continuous subcutaneous insulin infusion system reliability
Girardot, S. (2020) · theses.fr (ABES) · doi:10.70675/4f3118b9zebc2z40b9z9baczafa4dd39494c · Cited by 1
Keenan, D. B., & Steil, G. M. (2014) · Wiley eBooks · doi:10.1002/9781118873434.ch51
Wireless System with Multianalyte Implantable Biotransducer
Kotanen, C. N., & Guiseppi‐Elie, A. (2013) · Springer eBooks · doi:10.1007/978-1-4614-1674-6_3
García-García, F. (2015) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.37805
Measure for measure: consequences, detection and treatment of hyperglycaemia
Hermanides, J. (2010) · UvA-DARE (University of Amsterdam)
Clarke, W. L. (2010) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2012.08.01.22
“Current research has evolved into the testing of various control algorithms which use CGM data to guide intermittent insulin infusions.(29,30,40) This rapidly developing field holds great promise for children with type 1 diabetes and their parents.”
Self-citationThe artificial pancreas, a challenge to research
van Bon, A. C. (2013) · UvA-DARE (University of Amsterdam)
Robust strategies for glucose control in type 1 diabetes
Tomás, A. R. (2015) · RiuNet (Universitat Politècnica de València) · doi:10.4995/thesis/10251/56001
Progress with Closed-loop Systems in Type 1 Diabetes
Leelarathna, L., & Hovorka, R. (2010) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2010.06.02.31
Closed-Loop Interstitial Fluid Sensing Continuous Glucose Monitor
Hood, W. (2016) · Undergraduate Research Day · doi:10.15786/13703389
Model-Based Closed-Loop Glucose Control in Critical Illness
Knab, T. D. (2017) · D-Scholarship@Pitt (University of Pittsburgh)
Basal Insulin Adjustments and Continuous Glucose Monitoring During Exercise in Type 1 Diabetes
Zaharieva, D. P. (2018) · YorkSpace (York University)
Impact of Sensing and Actuation Characteristics on Artificial Pancreas Design
Huyett, L. M. (2016) · eScholarship (California Digital Library)
Graphene‐Based Biosensors: Fundamental Concepts, Outline of Utility, and Future Scopes
Kar, S., & Sarswat, P. K. (2019) · Wiley eBooks · doi:10.1002/9781119468455.ch87
Identificación de modelos relevantes al control de glicemia en personas con diabetes mellitus tipo 1
Giraldo, H., & David, J. (2020)
MAH, U. E., & Woafo, P. (2020) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519420500554
IoT-Based Health Monitoring System for Post-Covid with Diabetes
Lakshmi, P. P., & Sivagami, M. (2024) · Lecture notes in networks and systems · doi:10.1007/978-981-97-2671-4_20
Znaczenie technicznego wyposażenia dla przebiegu cukrzycy typu 1 u dzieci
(2015) · Wielkopolska Digital Library
Ma, K. (2025) · HARVEST (University of Saskatchewan)
Advanced Technology in Diabetes: Sensors and Pumps
Forlenza, G. P. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-11985-9.00023-8
Charchaoui, F., Ouardi, A. E., & Abdoun, O. (2026) · International Conference on Circuit, Systems and Communication (ICCSC) · doi:10.1109/iccsc71566.2026.11650379
“The devices that followed over the next four decades gradually converged on a hybrid closed-loop design: a CGM sensor paired with an insulin pump whose delivery rate is adjusted by a Model Predictive Control or PID algorithm [6]– [8].”
CONTROL OF CONSTRAINED BIOSYSTEMS
Tomás, A. R. (2011)
Metadata
- Authors
- Clarke, W. L., Anderson, S., Breton, M., Patek, S., Kashmer, L., & Kovatchev, B.
- Affiliations
- University of Virginia Health System (US)
- University of Virginia (US)
- Corresponding author
- Clarke, William L.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2009-09
- Volume
- 3
- Issue
- 5
- Pages
- 1031-1038
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC2769907
- OpenAlex
- W2084515220
- Semantic Scholar
- 7825bcf3b20f24d934b8176fd1e7cc7f62220060
- Cited by
- 185
- References
- 14
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 4 · 2023: 2 · 2022: 5 · 2021: 6 · 2020: 12 · 2019: 12 · 2018: 15 · 2017: 5 · 2016: 6 · 2015: 12 · 2014: 21 · 2013: 28 · 2012: 15
- Type
- conference abstract
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01dk051562-23)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK 51562)
- National Center for Research Resources (M01RR000847, M01-RR 00847)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- artificial pancreas, type 1 diabetes, model predictive control, continuous glucose monitoring, continuous insulin infusion, glycemic control, hypoglycemia prevention, postprandial glucose excursions
- MeSH terms
- Adult, Algorithms, Blood Glucose, Computer Simulation, Diabetes Mellitus, Type 1, Dietary Carbohydrates, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Male, Middle Aged, Models, Biological, Pilot Projects, Predictive Value of Tests, Time Factors, Blood Glucose Self-Monitoring, Treatment Outcome, Pancreas, Artificial, Postprandial Period, Diagnostic Equipment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.