Glucose Sensor Membranes for Mitigating the Foreign Body Response
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Continuous glucose monitoring devices remain limited in their duration of use due to difficulties presented by the foreign body response (FBR), which impairs sensor functionality immediately following implantation via biofouling and leukocyte infiltration. The FBR persists through the life of the implant, culminating with fibrous encapsulation and isolation from normal tissue. These issues have led researchers to develop strategies to mitigate the FBR and improve tissue integration. Studies have often focused on abating the FBR using various outer coatings, thereby changing the chemical or physical characteristics of the sensor surface. While such strategies have led to some success, they have failed to fully integrate the sensor into surrounding tissue. To further address biocompatibility, researchers have designed coatings capable of actively releasing biological agents (e.g., vascular endothelial growth factor, dexamethasone, and nitric oxide) to direct the FBR to induce tissue integration. Active release approaches have proven promising and, when combined with biocompatible coating materials, may ultimately improve the in vivo lifetime of subcutaneous glucose biosensors. This article focuses on strategies currently under development for mitigating the FBR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“1 All implantable medical devices perturb the host medium, damage capillaries, and ultimately lead to an immune response that includes (1) formation of a provisional matrix (minutes–hours), (2) acute inflammation (days), (3) chronic inflammation (weeks), (4) granulation tissue formation (weeks), and (5) fibrous capsul…”
BackgroundBiological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465 · cited 2×
“Current strategies for improving glucose sensor biocompatibility may be grouped into two areas: (1) passive coatings and (2) active release.”
BackgroundNitric oxide donors: chemical activities and biological applications
Wang, P. G., Xian, M., Tang, X., Wu, X., Wen, Z., Cai, T., & Janczuk, A. J. (2002) · Chemical Reviews · doi:10.1021/cr000040l · Cited by 1,337
Reducing implant-related infections: active release strategies
Hetrick, E. M., & Schoenfisch, M. H. (2006) · Chemical Society Reviews · doi:10.1039/b515219b · Cited by 1,201
Self-citationMethods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Refai, A. K., Textor, M., Brunette, D. M., & Waterfield, J. D. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30075 · Cited by 296
Edelman, J. L., Lutz, D., & Castro, M. R. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2004.09.013 · Cited by 246
Cao, H., Mchugh, K., Chew, S. Y., & Anderson, J. M. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32609 · Cited by 243
Concurrent delivery of dexamethasone and VEGF for localized inflammation control and angiogenesis
Patil, S. D., Papadmitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.013 · Cited by 230
Cited by
Hydrogel interfaces for merging humans and machines
Yuk, H., Wu, J., & Zhao, X. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00483-4 · Cited by 661
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Self-citationZhang, D., Chen, Q., Shi, C., Chen, M., Ma, K., Wan, J., & Liu, R. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007226 · Cited by 303
Didyuk, O., Econom, N., Guardia, A., Livingston, K., & Klueh, U. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819899394 · Cited by 175
The effect of nitric oxide surface flux on the foreign body response to subcutaneous implants
Nichols, S. P., Koh, A., Brown, N. L., Rose, M. B., Sun, B., Slomberg, D. L., Riccio, D. A., Klitzman, B., & Schoenfisch, M. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.053 · Cited by 67
“However, complete avoidance of the FBR has yet to be achieved and the field of biomaterials has evolved to include the design of coatings that actively release FBR mediators [10].”
BackgroundSelf-citation
Metadata
- Authors
- Koh, A., Nichols, S. P., & Schoenfisch, M. H.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2011-09
- Volume
- 5
- Issue
- 5
- Pages
- 1052-1059
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2124082567
- Cited by
- 41
- References
- 40
- Type
- conference abstract
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Glucose Sensor Membranes for Mitigating the Foreign Body Response. https://app.cochat.ai/papers/10.1177/193229681100500505
- The paper
- Koh, A., Nichols, S. P., & Schoenfisch, M. H. (2011). Glucose Sensor Membranes for Mitigating the Foreign Body Response. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681100500505
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.