The UVA/PADOVA Type 1 Diabetes Simulator: New Features
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index; 10 of the 22 sources its claims cite were checked for support.
Abstract
Recent studies have provided new insights into nonlinearities of insulin action in the hypoglycemic range and into glucagon kinetics as it relates to response to hypoglycemia. Based on these data, we developed a new version of the UVA/PADOVA Type 1 Diabetes Simulator, which was submitted to FDA in 2013 (S2013). The model of glucose kinetics in hypoglycemia has been improved, implementing the notion that insulin-dependent utilization increases nonlinearly when glucose decreases below a certain threshold. In addition, glucagon kinetics and secretion and action models have been incorporated into the simulator: glucagon kinetics is a single compartment; glucagon secretion is controlled by plasma insulin, plasma glucose below a certain threshold, and glucose rate of change; and plasma glucagon stimulates with some delay endogenous glucose production. A refined statistical strategy for virtual patient generation has been adopted as well. Finally, new rules for determining insulin to carbs ratio (CR) and correction factor (CF) of the virtual patients have been implemented to better comply with clinical definitions. S2013 shows a better performance in describing hypoglycemic events. In addition, the new virtual subjects span well the real type 1 diabetes mellitus population as demonstrated by good agreement between real and simulated distribution of patient-specific parameters, such as CR and CF. S2013 provides a more reliable framework for in silico trials, for testing glucose sensors and insulin augmented pump prediction methods, and for closed-loop single/dual hormone controller design, testing, and validation.
Overview
CoChat Summary
TL;DR
The paper presents S2013, a new version of the UVA/PADOVA Type 1 Diabetes Simulator, adding hypoglycemia-aware glucose utilization, glucagon secretion/action, updated joint parameter distributions, and stricter virtual-subject generation. The authors argue that S2013 better describes hypoglycemic events and better matches real CR and CF distributions, while remaining FDA-submitted for preclinical in silico use.
Key findings
- The original S2008 simulator included a population of 300 in silico subjects: 100 adults, 100 adolescents, and 100 children; the paper says S2008 had been used by 32 research groups and reported in 63 peer-reviewed publications.
- S2013 adds a hypoglycemia model with a threshold set at 60 mg/dl and incorporates glucagon kinetics/secretion/action, including a 1-compartment glucagon kinetics model and a 2-compartment subcutaneous glucagon transit model.
- The new simulator was assessed on 32 T1DM subjects in an unpublished clamp dataset and on 13 data sets from 11 adults with T1DM in a bihormonal closed-loop clinical trial; the paper states the model fits glucose data well before the threshold and underestimates data afterward as expected.
- In simulation results for 100 adults, 100 adolescents, and 100 children, the paper reports that the distributions of CR and CF “well reproduce” real patients, and that children had higher CFs than adolescents and adults; the table reports mean weight, insulin needs, CHO ratio, and fasting plasma glucose for each group.
Methods
- The paper is a simulator-development paper comparing S2013 to S2008, describing changes to the glucose-insulin model, counterregulation, parameter distributions, and virtual patient generation.
- It uses simulation and model identification/assessment on two empirical datasets: 32 T1DM subjects undergoing hyperinsulinemic euglycemic and hypoglycemic clamps, and 11 adults with T1DM (13 data sets) from a 27-hour bihormonal closed-loop study with 3 carbohydrate-rich meals.
- Main analyses include fitting the hypoglycemia model, simulating 50 g CHO meal tests for CR estimation, using the 1700 rule for CF, and filtering virtual subjects by CR thresholds, steady-state glucose > 300 mg/dl, and Mahalanobis distance below the 95% percentile.
Limitations
- The authors explicitly state that the subcutaneous glucagon model “suffers some important limitations,” because it was hard to isolate insulin’s effect on glucagon response since insulin is constantly changing, and glucagon is given repeatedly in the study.
- They note that both S2008 and S2013 were validated and accepted by FDA for a single meal scenario only; multiple-meal scenarios can be simulated, but results would not be realistic because the simulator does not include time-varying parameters.
- Evident from the text: the paper repeatedly presents validation and comparison results, but it does not report formal performance metrics such as error estimates, p-values, or confidence intervals for the simulator comparisons.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
6 Valid · 2 Not valid · 5 Not checked · 24 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The development of artificial pancreas control algorithms in the past few years has been accelerated by computer simulation; for example, in silico testing has provided directions for clinical studies and ruling out of ineffective control scenarios in a cost-effective manner. 1,2”
What the sources say
- Supportedcites [1] matched to “Diabetes: Models, Signals, and Control” (2009) source
Section IV.D says in silico testing supported authorization of a clinical trial, helped rule out ineffective control scenarios, and produced preclinical results in a fraction of the time and cost of animal trials. This supports the claim that simulation accelerated artificial-pancreas algorithm development, while the paper cautions that simulation does not replace clinical trials. (LLM, conf=0.93)
- Partly supportedcites [2] matched to “Artificial Pancreas: Past, Present, Future” (2011) sourceExperimental — accuracy not yet measured
In “A step forward: in silico experiments replacing animal trials” (page unavailable), the paper says simulation is already used to test control algorithms efficiently and at a fraction of the time and cost of animal trials. But it says simulation *will* greatly accelerate future artificial-pancreas development; it does not establish that algorithm development had already accelerated in the past few years. (LLM, conf=0.85)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“This model was assessed on a clinical data set kindly provided by Dr Damiano's group (Boston University), which was collected in a bihormonal closed-loop clinical trial. 15”
What the sources say
- Could not verifycites [15] matched to “Duration of type I diabetes affects glucagon and glucose responses to insulin-induced hypoglycemia.” (1984)Experimental — accuracy not yet measured
The Patients and Methods passages (page not provided) describe insulin-tolerance tests and measurements of glucose and pancreatic glucagon, not an assessment of a subcutaneous glucagon transport model. Searches for the model, Dr. Damiano’s group, and a bihormonal closed-loop trial found no passage addressing the attributed claim. (LLM, conf=0.76)
plainn = 11- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“This phenomenon has been described during hyperinsulemic clamps in T1DM. 9,10”
What the sources say
- Partly supportedcites [9] matched to “Modeling Insulin‐Glucose Dynamics during Insulin Induced Hypoglycemia. Evaluation of Glucose Counterregulation” (1999) sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) reports that, during hyperinsulinemic clamps in patients with type 1 diabetes, a lower glucose nadir was associated with faster model-estimated insulin utilization. It does not describe insulin action increasing within a patient as glucose crosses a particular threshold; the reported association is across subjects. (LLM, conf=0.85)
- Not checked — no full text of the sourcecites [10] matched to “Dynamic network model of glucose counterregulation in subjects with insulin-requiring diabetes” (2000) source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The choice to include glucagon secretion was based on our recent data in T1DM 23 showing a nonnegligible glucagon secretion.”
What the sources say
- Partly supportedcites [23] matched to “Diurnal Pattern of Insulin Action in Type 1 Diabetes” (2013) sourceExperimental — accuracy not yet measured
The Results section (page unavailable) reports measurable plasma glucagon concentrations in people with type 1 diabetes and a postprandial increase that differed by meal. That supports including glucagon in a model, but the paper reports concentrations rather than directly measuring secretion or establishing its magnitude as “nonnegligible.” (LLM, conf=0.82)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“S2013 shows a better performance in describing hypoglycemic events.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
13 more claims
Create a free account to see all 37 claims and every source verdict.
- It may state two separate claims as one. 17
- Probably not a substantial claim. 5
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“On the contrary, the Hovorka model and the UVAPadova model were originally formulated to represent the physiological behaviour of T1DM individuals, and no modification is necessary for the purpose of the present work.”
From A comparison among three maximal mathematical models of the glucose-insulin system (2021) · cites this paper as [23]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This model is indeed included in the EGP module of the UVa/Padova T1D simulator [32–34].”
From Modeling the effect of glucagon on endogenous glucose production in healthy individuals under meal-like conditions (2025) · cites this paper as [33]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While the Hovorka model and the UVAPadova Simulator only describe the glucose metabolism of a subject with type 1 diabetes, the Sorensen model was formulated to simulate the behaviour of both normal and diabetic individuals.”
From A comparison among three maximal mathematical models of the glucose-insulin system (2021) · cites this paper as [23]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The training set, which spanned a wide range of pre-meal conditions and patient characteristics, was created in silico by the UVa/Padova T1D Simulator [38], a simulation tool that includes a model of glucose-insulin-glucagon dynamics in subjects with T1D, accepted by the FDA to substitute preclinical trials of certain insulin treatments.”
From Advanced Diabetes Management Using Artificial Intelligence and Continuous Glucose Monitoring Sensors (2020) · cites this paper as [38]
The cited source says what the claim attributes to it.
In the citing paper
“Another example is compartmental glucose-insulin models, which have been used to generate virtual cohorts to evaluate automated insulin pumps [38,39]”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [38]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ T1DM Simulator 2013 (S2013)
“which was collected in a bihormonal closed-loop clinical trial. 15”
§ References
“15. Lorenzi M, Bohannon N, Tsalikian E, et al. Duration of type 1 diabetes affects glucagon and glucose responses to insulininduced hypoglycemia. West J Med . 1984;141:467-471.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ T1DM Simulator 2013 (S2013)
“only subjects who met the following criteria have been included in the new in silico population: (1) CR ≤ 30 g/U for adult and adolescents and CR ≤ 40 g/U for children”
§ Simulation Results
“| CHO ratio (g/U) | 15.9 (5.3) | 7.2 | 29.5 | 16.0 (5.9) | 5.3 | 32.2 | 23.6 (6.6) | 8.0 | 33.7 |”
Citations
Cites
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874 · cited 1×
“where G(t) is plasma glucose concentration, I(t) is plasma insulin concentration, GIR(t) is exogenous glucose infusion rate, SG, SI, and p 2 are model parameters, and risk is defined as in (11-12).”
BackgroundSelf-citationIn Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Self-citationArtificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Self-citationDiabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
Self-citationA Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403
A Comparison of Childhood and Adult Type I Diabetes Mellitus
Karjalainen, J., Salmela, P., Ilonen, J., Surcel, H.-M., & Knip, M. (1989) · New England Journal of Medicine · doi:10.1056/nejm198904063201401 · Cited by 279
Age of Onset and Type of Diabetes
Laakso, M., & Pyörälä, K. (1985) · Diabetes Care · doi:10.2337/diacare.8.2.114 · Cited by 245
Evaluating the Efficacy of Closed-Loop Glucose Regulation via Control-Variability Grid Analysis
Magni, L., Raimondo, D. M., Man, C. D., Breton, M., Patek, S., De Nicolao, G., Cobelli, C., & Kovatchev, B. P. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200414 · Cited by 207
Self-citationIncidence of Type 1 and Type 2 Diabetes in Adults Aged 30–49 Years
Bruno, G., Runzo, C., Cavallo-Perin, P., Merletti, F., Rivetti, M., Pinach, S., Novelli, G., Trovati, M., Cerutti, F., Pagano, G., et al. (2005) · Diabetes Care · doi:10.2337/diacare.28.11.2613 · Cited by 187
Closing the Loop: The Adicol Experience
Hovorka, R., Chassin, L. J., Wilinska, M. E., Canonico, V., Akwi, J. A., Federici, M. O., Massi-Benedetti, M., Hutzli, I., Zaugg, C., Kaufmann, H., et al. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774197990 · Cited by 154
Research works printed but not linked: 4
- Bergman RN, 1979, Am J Physiol, 236, E667
- Lorenzi M, 1984, West J Med, 141, 467
- Walsh J, Pumping Insulin. Everything You Need for Success with an Insulin Pump, 2000, 105
- Davidson PC, 2003, Diabetes Technol Ther, 5, 237
Cited by
Items 301–400 of 786
Frei, T., Chang, C.-H., Filo, M., Arampatzis, A., & Khammash, M. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.12.06.412304 · Cited by 11
“Our results propose a closed-loop alternative to open-loop replacement therapy with exogenous insulin, which in the case of T1DM is prescribed for life.”
BackgroundInfluentialBlood Glucose Prediction for Type-1 Diabetics using Deep Reinforcement Learning
Domanski, P., Ray, A., Firouzi, F., Lafata, K. J., Chakrabarty, K., & Pflüger, D. (2023) · IEEE International Conference on Digital Health (ICDH) · doi:10.1109/icdh60066.2023.00042 · Cited by 16
“R) [14], Padova T1D Simulator [15], Web-based Simulation Tool [16], Simglucose [17], GluCoEnv [18], to name a few.”
Ibrahim, M., Beneyto, A., Contreras, I., & Vehí, J. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108154 · Cited by 13
Emi-Johnson, O. G., & Nkrumah, K. J. (2025) · Cureus · doi:10.7759/cureus.82437 · Cited by 44
Glucagon – the new ‘insulin’ in the pathophysiology of diabetes
Farhy, L. S., & McCall, A. L. (2015) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/mco.0000000000000192 · Cited by 10
Regularization Techniques to Overcome Overparameterization of Complex Biochemical Reaction Networks
Howsmon, D. P., & Hahn, J. (2016) · IEEE Life Sciences Letters · doi:10.1109/lls.2016.2646498 · Cited by 11
“INTRODUCTION MODELS of biochemical reaction networks composed of ordinary differential equations (ODEs) have been successfully employed for a variety of purposes, including summarizing experimental evidence [1], distinguishing between possible mechanisms [2], and reducing experimental burden [3].”
BackgroundMcGrath, T., Murphy, K. G., & Jones, N. S. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0736 · Cited by 12
“These efforts have begun to show fruit, leading to a simulation model approved for preclinical testing of insulin delivery algorithms [23,24] and closed-loop insulin pumps now being brought to market.”
Fault Detection in Artificial Pancreas: A Model-Free approach
Meneghetti, L., Terzi, M., Susto, G. A., Favero, S. D., & Cobelli, C. (2018) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2018.8619048 · Cited by 13
“called UVA/Padova T1D simulator, [17].”
Self-citationAngrisani, L., Annuzzi, G., Arpaïa, P., Bozzetto, L., Cataldo, A., Corrado, A., Benedetto, E. D., Capua, V. D., Prevete, R., & Vallefuoco, E. (2022) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc48687.2022.9806611 · Cited by 12
“The literature [14]–[17] has investigated the ANN algorithms, either using data from diabetic patients or computer-simulated patients, commonly named virtual patients [18], as those obtained in [19].”
MethodDecision making for safety and risk in healthcare and process systems
Sontakke, M., Okpanum, J., Yerimah, L. E., Rebmann, A., Ghosh, S., & Bequette, B. W. (2023) · Chemical Engineering Science · doi:10.1016/j.ces.2023.118866 · Cited by 15
Real-Time Insulin Bolusing for Unannounced Meals Using CGM Measurements
Turksoy, K., & Çınar, A. (2015) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2015.10.142 · Cited by 10
Contreras, I., Vehí, J., VISENTIN, R., & Vettoretti, M. (2017) · IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies · doi:10.1109/chase.2017.61 · Cited by 10
“Due to the lack of profiled data, we use the UVA/Padova T1D simulator [10], a software accepted by U.S. Food and Drug Administration as a substitute for preclinical trials for certain insulin treatments.”
MethodNear-optimal feedback control for postprandial glucose regulation in type 1 diabetes
Sanz, R., García, P., Romero‐Vivó, S., Díez, J.-L., & Bondía, J. (2022) · ISA Transactions · doi:10.1016/j.isatra.2022.06.033 · Cited by 10
A framework for modeling and analyzing cyber-physical systems using statistical model checking
Alshalalfah, A.-L., Mohamed, O. A., & Ouchani, S. (2023) · Internet of Things · doi:10.1016/j.iot.2023.100732 · Cited by 13
Towards System Level Security Analysis of Artificial Pancreas Via UPPAAL-SMC
Alshalalfah, A.-L., Hamad, G. B., & Mohamed, O. A. (2019) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2019.8702440 · Cited by 11
“different compartments of the body based on a commonlyused physiological model [15].”
BackgroundMethodInfluentialFushimi, E., Serafini, M. C., Battista, H. D., & Garelli, F. (2020) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-020-02213-w · Cited by 11
Visentin, R., Schiavon, M., Giegerich, C., Klabunde, T., Man, C. D., & Cobelli, C. (2018) · 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513234 · Cited by 9
“Plasma insulin kinetic is described by the twocompartment model already implemented in the UVA/Padova T1D simulator [3]:”
BackgroundMethodSelf-citationRenuse, S., Benson, L. M., Vanderboom, P. M., RUCHI, F., YADAV, Y. R., Johnson, K. L., Brown, B. C., Peterson, J. A., Basu, R., McCormick, D., et al. (2022) · Clinical Proteomics · doi:10.1186/s12014-022-09344-2 · Cited by 9
“The proposed method will also allow, for the first time, to precisely determine the key paracrine interaction, its dysregulation and help develop an explicit glucagon model for testing in the FDA-approved T1D simulator [17, 18] prior to clinical trials.”
MethodConstrained Versus Unconstrained Model Predictive Control for Artificial Pancreas
Toffanin, C., & Magni, L. (2023) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2023.3291564 · Cited by 11
“The linear saturated MPC (S-MCP) proposed in [34] obtained promising results both in vivo [9], [10], [35] and in silico [34], [36], [37], using the previous version of the UVA/Padova simulator (S2013) [32].”
BackgroundMethodInfluentialQin, X., Xia, Y., Zutshi, A., Fan, C., & Deshmukh, J. V. (2023) · ACM Transactions on Cyber-Physical Systems · doi:10.1145/3635160 · Cited by 14
Edge AI Empowered Personalized Privacy-Preserving Glucose Prediction with Federated Deep Learning
Yang, X., & Li, J. (2023) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom56612.2023.10472368 · Cited by 11
“Due to the limited patient data availability, many studies on glucose prediction have utilized simulators like the UVA/Padova Type 1 diabetes simulator, approved by the Food and Drug Administration [33].”
MethodLu, X., Cai, D., Liu, W., Ji, L., & Shi, D. (2025) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2025.3548101 · Cited by 10
“The performance of the algorithm is first evaluated utilizing a 10-adult cohort from the UVa / Padova T1DM Simulator [35].”
Godoy, J. L., Sereno, J. E., & Rivadeneira, P. S. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102715 · Cited by 11
Neural identification of Type 1 Diabetes Mellitus for care and forecasting of risk events
Sánchez, O. D., Alanís, A. Y., Ruiz-Velazquez, E., & Murillo, R. V. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2021.115367 · Cited by 10
Subramanian, V., Bagger, J. I., Harihar, V., Holst, J. J., Knop, F. K., & Villsbøll, T. (2023) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00278.2023 · Cited by 12
Deployment of modular MPC for type 1 diabetes control: the Italian experience 2008–2016
Favero, S. D., Toffanin, C., Magni, L., & Cobelli, C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815655-1.00016-8 · Cited by 11
Self-citationGlucose Regulation for Subjects with Type 1 Diabetes Using Active Disturbance Rejection Control
Cai, D., Song, J., Wang, J., & Shi, D. (2019) · Chinese Control Conference (CCC) · doi:10.23919/chicc.2019.8866391 · Cited by 9
“Using the 10-patient cohort of the FDA accepted UVA/Padova simulator [26], and following the 12-hour in silico protocol with 1 unannounced/announced meal of 60g carbohydrate (CHO) at 9:00, the controller parameters are tuned with the goal of achieving basic glucose control based on ADRC.”
MethodInfluentialÇankaya, N., & Aydoğdu, Ö. (2020) · IEEE Access · doi:10.1109/access.2020.3015454 · Cited by 10
Koutný, T., & Úbl, M. (2020) · Procedia Computer Science · doi:10.1016/j.procs.2020.10.048 · Cited by 10
“(1) Bergman model [28] combined with Hovorka’s absorption model [10] and Koutny’s diffusion model, which calculates the interstitial fluid glucose level (IG) [15, 16], UVA/Padova (2) S2013[31] and (3) S2017 [32] models.”
MethodPredicting continuous blood glucose level using deep learning
Shahid, S., Hussain, S., & Khan, W. A. (2021) · IEEE/ACM International Conference on Utility and Cloud Computing Companion (UCC Companion) · doi:10.1145/3492323.3495598 · Cited by 9
“The data used in this study is a simulated data of 10 T1DM of different ages; we generated a dataset using an open-source simulator named Simglucose [10].”
MethodIntegrating Compartment Models with Recursive System Identification
Hajizadeh, I., Rashid, M. M., & Çınar, A. (2018) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2018.8431822 · Cited by 10
“Simulation case studies involving in silico subjects from the University of Virginia/Padova (UVA/Padova) metabolic simulator demonstrate the improvement in prediction ability of the proposed approach [19].”
BackgroundMethodOn Ensuring that Intelligent Machines Are Well-BehavedPreprint
Thomas, P. S., da Silva, B. C., Barto, A. G., & Brunskill, E. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1708.05448 · Cited by 15
“H . Figure 2 shows the result of applying both our Seldonian algorithm and a similar algorithm designed using the standard approach. For this experiment we used a detailed metabolic simulator [Dalla Man et al., 2014]. Given the recent surge of real-world machine learning applications and the corresponding surge of pot…”
MethodInfluentialA Dual-Hormone Closed-Loop Delivery System for Type 1 Diabetes Using Deep Reinforcement LearningPreprint
Zhu, T., Li, K., & Georgiou, P. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1910.04059 · Cited by 14
Towards Safe Policy Improvement for Non-Stationary MDPsPreprint
Chandak, Y., Jordan, S. M., Theocharous, G., White, M., & Thomas, P. S. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2010.12645 · Cited by 34
“Non-Stationary Diabetes Treatment: This environment is based on an open-source implementation [68] of the FDA approved Type-1 Diabetes Mellitus simulator (T1DMS) [44, 37] for treatment of Type-1 diabetes.”
Schiavon, M., Galderisi, A., Basu, A., Kudva, Y. C., Cengiz, E., & Dalla Man, C. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0397 · Cited by 8
“Another limitation concerns the need to fix some parameters (GEZI, V G , r 1 , and r 2 ) to population values 3,25,36 and to calculate others from population models (CL) using anthropometric data.”
Synthetic biomedical data generation in support of In Silico Clinical Trials
Simalatsar, A. (2023) · Frontiers in Big Data · doi:10.3389/fdata.2023.1085571 · Cited by 12
“An updated version of the T1DM simulator that included a model of counter-regulation and a new description of glucose dynamics in hypoglycemia has been presented in 2013 (Man et al., 2014) and was also approved by the FDA.”
BackgroundMethodInfluentialPanagiotou, M., Brigato, L., Streit, V., Hayoz, A., Proennecke, S., Athanasopoulos, S., Olsen, M. T., Brok, E. J. D., Svensson, C. H., Makrilakis, K., et al. (2025) · IEEE Access · doi:10.1109/access.2025.3600738 · Cited by 9
Hwang, M., Rachim, V. P., Yoo, J., Lee, Y., & Park, S. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01994-4 · Cited by 13
Securing automated insulin delivery systems: A review of security threats and protective strategies
Niu, Y., & Lam, S.-K. (2025) · Computers & Security · doi:10.1016/j.cose.2025.104733 · Cited by 12
“Additionally, AID systems-faulty data, generated by the testbed described by Zhou et al. [126], comprises synthetic data from closed-loop simulations, including both safe and hazardous data traces from 20 patient profiles, providing a useful source for evaluating fault detection and risk management.”
Harnessing Nonlinear Mechanics to Transform Medical Diagnostics
Nataraj, C., & Hemmati, S. (2025) · Applied Mechanics Reviews · doi:10.1115/1.4070319 · Cited by 10
“…decline (essential for insulin production) and years-long disease progression [138] and virtual patient populations such as the UVA/Padova simulator [139] from University of Virginia and University of Padova demonstrate how variability and uncertainty can be integrated into translational tools.”
Olçomendy, L., Pirog, A., Bornat, Y., Cieslak, J., Gucik‐Derigny, D., Henry, D., Catargi, B., & Renaud, S. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175292 · Cited by 12
“First published in 2007, the metabolic model has been updated over the years to include increasingly complex and realistic physiological mechanism [9], [10].”
BackgroundGlucose Prediction using Wide-Deep LSTM Network for Accurate Insulin Dosing in Artificial Pancreas
Kalita, D., & Mirza, K. B. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9870983 · Cited by 13
“The dataset used for training and validation consisted of in silico data, generated for 10 adults using the UVA/Padova simulator [6].”
MethodPrendin, F., Díez, J.-L., Favero, S. D., Sparacino, G., Facchinetti, A., & Bondía, J. (2022) · Sensors · doi:10.3390/s22228682 · Cited by 10
“These in silico simulations have been performed by exploiting a modified setup of the educational version of the UVA/Padova simulator [28].”
MethodNoise modeling of tumor size measurements from animal experiments for virtual patient generation
Puskás, M., Gergics, B., Gombos, B., Füredi, A., Szakács, G., Kovács, L., & Drexler, D. A. (2023) · IEEE International Conference on Intelligent Engineering Systems (INES) · doi:10.1109/ines59282.2023.10297747 · Cited by 12
“The measured variable during the experiments is the full tumor volume, which is the sum of the living and experiments for virtual patient generation”
MethodFratus, M., & Alam, M. A. (2023) · Biomedical Microdevices · doi:10.1007/s10544-023-00683-x · Cited by 8
“An artificial pancreas is a prime example, as it detects glucose levels and administers insulin accordingly (Dalla Man et al. 2014).”
Importance Sampling with Unequal Support
Thomas, P. S., & Brunskill, E. (2017) · AAAI Publications (The Association for the Advancement of Artificial Intelligence (AAAI)) · doi:10.1609/aaai.v31i1.10932 · Cited by 8
“We used the subject “Adult#003” in the Type 1 Diabetes Metabolic Simulator (T1DMS) (Dalla Man et al., 2014)—a simulator that has been approved by the US Food and Drug Administration as a substitute for animal trials in pre-clinical testing of treatment policies for type 1 diabetes.”
MethodGaetano, A. D., Gaz, C., & Panunzi, S. (2019) · PLoS ONE · doi:10.1371/journal.pone.0211331 · Cited by 9
A Robust Control solution for Glycaemia Regulation of Type-1 Diabetes Mellitus
Cassany, L., Gucik‐Derigny, D., Cieslak, J., Henry, D., Franco, R., de Loza, A. F., Ríos, H., Olçomendy, L., Pirog, A., Bornat, Y., et al. (2021) · European Control Conference (ECC) · doi:10.23919/ecc54610.2021.9654888 · Cited by 11
A Robust H∞ Control Approach for Blood Glucose Regulation in Type-1 Diabetes
Cassany, L., Gucik‐Derigny, D., Cieslak, J., Henry, D., Franco, R., de Loza, A. F., Ríos, H., Olçomendy, L., Pirog, A., Bornat, Y., et al. (2021) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2021.10.299 · Cited by 10
Chen, J., Xiao, R., Wang, L., Zhu, L., & Shi, D. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3137618 · Cited by 9
Úbl, M., Koutný, T., Cioppa, A. D., Falco, I. D., Tarantino, E., & Scafuri, U. (2022) · Sensors · doi:10.3390/s22239445 · Cited by 9
“S2008 [30] S2013 [31] S2017 [18] T1DMS [17] DMMS.”
Sun, X., Çınar, A., Liu, J., Rashid, M. M., & Yu, X. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104551 · Cited by 8
Zafar, A., Lewis, D. M., & Shahid, A. (2023) · Healthcare · doi:10.3390/healthcare11060779 · Cited by 11
“In [8], simulated data from UVA-Padova [21] (360 simulated days of 10 patients) and OhioT1DM dataset (8 weeks of clinical trials on 6 patients) were employed to train a dilated recurrent neural network (D-RNN) with prediction RMSE of 20.1 mg/dL.”
MethodInfluentialLema-Pérez, L., Aguirre-Zapata, E., & Garcia‐Tirado, J. (2015) · IEEE Colombian Conference on Automatic Control (CCAC) · doi:10.1109/ccac.2015.7345212 · Cited by 10
“In 2013, in view of the importance of glucagon role in the blood glucose homoeostatic mechanism to regulate the hypoglycaemia and considering the close relationship between all the hormones secreted by the pancreas, like glucagon secretion controlled by plasma insulin, plasma glucose below a certain threshold and gluc…”
BackgroundUVa/Padova T1DMS dynamic model revision: For embedded model control
Molano-Jimenez, A., & Vargas, F. M. L. (2017) · IEEE Colombian Conference on Automatic Control (CCAC) · doi:10.1109/ccac.2017.8276390 · Cited by 8
“2) Oral Absorption Model The oral absorption model is described using the amount of glucose in stomach sto Q (solid 1 sto Q and liquid phase 2 sto Q ) and the glucose mass in the intestine gut Q as in [1]”
BackgroundMethodInfluentialAdaptive Model Predictive Control for Nonlinearity in Biomedical Applications
Hajizadeh, I., Rashid, M. M., Sevil, M., Brandt, R., Samadi, S., Hobbs, N., & Çınar, A. (2018) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2018.11.061 · Cited by 9
Shi, D., Dassau, E., & Doyle, F. J. (2018) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2018.8619675 · Cited by 9
“accepted Universities of Virginia/Padova simulator [18] for two in silico scenarios.”
MethodInfluentialA Novel Glucose Controller using Insulin Sensitivity Modulation for Management of Type 1 Diabetes
Güemes, A., Herrero, P., & Georgiou, P. (2019) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2019.8702535 · Cited by 9
“2) [28] was employed to implement, identify and test the performance of the controllers (see right panel in Fig.”
MethodKalman filter and sliding mode observer in artificial pancreas: an in-silico comparison
Sala-Mira, I., Siket, M., Eigner, G., Bondía, J., & Kovács, L. (2020) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2020.12.617 · Cited by 8
“The references for RMSE computation were collected from the Dalla-Man model which is implemented in the simulator (Dalla Man et al. (2014)), while the estimated signal units were modified accordingly to match the Dalla-Man ones.”
MethodInfluentialData-driven meal events detection using blood glucose response patterns
de Carvalho, D. F., Kaymak, U., Gorp, P. M. E. V., & van Riel, N. A. W. (2023) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-023-02380-4 · Cited by 7
“However, the models are trained on real data (not synthetically generated through simulators [19, 49]), which are very likely to contain the same type of issues: potentially wrong reported and missing values.”
Rapid Prototyping of Neuro-Fuzzy Inverse Optimal Control as Applied to T1DM Patients
Ríos, Y. Y., García-Rodríguez, J. A., Sanchez, E. N., Alanís, A. Y., & Ruiz-Velazquez, E. (2018) · IEEE Latin American Conference on Computational Intelligence (LA-CCI) · doi:10.1109/la-cci.2018.8625241 · Cited by 8
“Since 2008, this simulator is approved by the Food and Drug Administration (FDA) for the preclinical testing of control strategies in Artificial Pancreas [17], [18].”
BackgroundThe use of peak over threshold methods to characterise blood glucose curves
Szigeti, M., Ferenci, T., & Kovács, L. (2020) · IEEE International Symposium on Applied Computational Intelligence and Informatics (SACI) · doi:10.1109/saci49304.2020.9118838 · Cited by 6
van Sloun, B., Goossens, G. H., Erdõs, B., O’Donovan, S. D., Singh‐Povel, C. M., Geurts, J. M. W., van Riel, N. A. W., & Arts, I. C. W. (2023) · iScience · doi:10.1016/j.isci.2023.106218 · Cited by 8
Sun, X., Liu, J., Çınar, A., Yu, X., & Tan, S. (2023) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2023.3291560 · Cited by 10
“The efficiency of the proposed ET-MPC challenged by unannounced meals is evaluated by using a cohort of 30 subjects (ten adolescents, ten adults, and ten children) in the FDA-accepted UVA/Padova simulator [37], [38], [39], [40], TABLE I”
BackgroundMethodAlanís, A. Y., Sánchez, O. D., Vaca-González, A., & Rangel-Heras, E. (2023) · Mathematics · doi:10.3390/math11194065 · Cited by 8
“For its part, the UVA/Padova Diabetes simulator is representative of a DM population observed in a clinical trial [48].”
BackgroundRodríguez-Sarmiento, D. L., Jutinico, A. L., & Vargas, F. M. L. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106166 · Cited by 7
Conformance verification for neural network models of glucose-insulin dynamics
Kushner, T., Sankaranarayanan, S., & Breton, M. D. (2020) · International Conference on Hybrid Systems: computation and control · doi:10.1145/3365365.3382210 · Cited by 16
Self-citationΑθανασίου, Μ., Zarkogianni, K., Konstantinos, K., & Nikita, K. S. (2021) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe52308.2021.9635246 · Cited by 23
“DATASET The development and evaluation of the proposed personalized meal detection model was based on data generated by the UVA-PADOVA T1DM Simulator [16].”
MethodInfluentialVilla-Tamayo, M. F., Maira, G., Vargas, F. M. L., & Rivadeneira, P. S. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.796521 · Cited by 8
“The model parameters have been identified for the 10-adult virtual subjects available in the commercial version of the UVA/ Padova simulator (36).”
MethodLS-GRUNet: Glucose Forecasting Using Deep Learning for Closed-loop Diabetes Management
Kalita, D., & Mirza, K. B. (2022) · IEEE International Conference for Convergence in Technology (I2CT) · doi:10.1109/i2ct54291.2022.9824867 · Cited by 13
Halvorsen, M., Benam, K. D., Khoshamadi, H., & Fougner, A. L. (2022) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc51059.2022.9992638 · Cited by 8
“Models describing the glucose dynamics are not limited in the literature, and they range from minimal [13] to quite complex [14].”
BackgroundRobust μ-Controller for Automatic Glucose Regulation for Type I Diabetes Mellitus
Kralev, J. K., & Slavov, T. N. (2023) · Mathematics · doi:10.3390/math11183856 · Cited by 8
Furió-Novejarque, C., Sala-Mira, I., Díez, J.-L., & Bondía, J. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107968 · Cited by 7
Tailoring the Padova Type 2 Diabetes Simulator for Treatment Guidance in Target Populations
VISENTIN, R., Schiavon, M., Bonet, J., Riz, M., Wagenhuber, B., & Man, C. D. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3352153 · Cited by 9
“An example of such in silico tools is the UVA/Padova type 1 diabetes (T1D) simulator [2], [3], [4] that has been accepted and widely used as decision support system for testing several diabetes technology treatments, such as artificial pancreas prototypes (e.g., [5], [6], [7]) and, more recently,…”
MethodSelf-citationOptimality of Unconstrained Pulse Inputs to the Bergman Minimal Model
Townsend, C., & Seron, M. M. (2017) · IEEE Control Systems Letters · doi:10.1109/lcsys.2017.2734691 · Cited by 7
“Recently, research has focused on comprehensive models of glucose dynamics which are generally preferred to test treatment policies and control algorithms, for example [6].”
BackgroundShi, D., Dassau, E., & Doyle, F. J. (2018) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2018.8431902 · Cited by 8
“In this section, we evaluate the performance of the proposed controller design method on the academic 10-patient cohort of the UVA/Padova T1DM simulator [23].”
MethodInfluentialGlycemic Control of People With Type 1 Diabetes Based on Probabilistic Constraints
Nandi, S., & Singh, T. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2869365 · Cited by 10
“Since the traditional exponentially decaying models for glucose appearance in the Bergman model seem to depart from the glucose appearance rates from the FDA approved T1DMS simulator [11], a gut-dynamicmodel is included resulting in a sixth order model.”
MethodA phenomenological-based semi-physical model of the kidneys and its role in glucose metabolism
Lema-Pérez, L., Builes-Montaño, C. E., & Álvarez, H. (2020) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2020.110489 · Cited by 10
Computer simulations can replace in-vivo experiments for implantable medical devices
Sorgüven, E., Bozkurt, S., & Baldock, C. (2021) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-021-00978-4 · Cited by 8
Ríos, Y. Y., García-Rodríguez, J. A., Sanchez, E. N., Alanís, A. Y., Ruiz-Velazquez, E., & García, A. P. (2021) · ISA Transactions · doi:10.1016/j.isatra.2021.07.045 · Cited by 7
A Simple Soft Computing Structure for Modeling and Control
Redjimi, H., & Tar, J. K. (2021) · Machines · doi:10.3390/machines9080168 · Cited by 7
Artificial Pancreas: from Control-to-Range to Control-to-Target
Incremona, G. P., Messori, M., Toffanin, C., Cobelli, C., & Magni, L. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.1152 · Cited by 9
“In this paper, the proposed IMPC is synthesized on a linear time-invariant model, the structure of which is obtained from the linearization around a suitable working point of the more complex nonlinear model described in [Dalla Man et al., 2014].”
MethodSelf-citationSala, I., Díez, J.-L., & Bondía, J. (2018) · European Control Conference (ECC) · doi:10.23919/ecc.2018.8550123 · Cited by 8
“In this section, UVa-Padova simulator [31] is employed to assess the behavior of the observer.”
MethodPhysiological models for artificial pancreas development
VISENTIN, R., Schiavon, M., Basu, R., Basu, A., Man, C. D., & Cobelli, C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815655-1.00015-6 · Cited by 11
Self-citationShortcomings in the Evaluation of Blood Glucose Forecasting
Lee, J. M., Pop‐Busui, R., Lee, J. M., Fleischer, J., & Wiens, J. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3424665 · Cited by 12
“The simulator has been approved by the FDA as a replacement for pre-clinical trials in evaluating closed-loop algorithms and has been used by dozens of research groups in academia [25].”
A closed-loop microneedle-integrated physiological model for predictive glycemic management
Fratus, M., & Alam, M. A. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2523517122 · Cited by 9
Ultimate Bounds for a Diabetes Mathematical Model Considering Glucose Homeostasis
Gamboa, D., Coria, L. N., & Valle, P. A. (2022) · Axioms · doi:10.3390/axioms11070320 · Cited by 6
Gonzalez-Flo, E., Kheirabadi, E., Rodríguez‐Caso, C., & Macía, J. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1149698 · Cited by 6
Reiterer, F., Reiter, M., del Re, L., Christensen, M. B., & Nørgaard, K. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818770694 · Cited by 7
Nonlinear Machine Learning Models for Insulin Bolus Estimation in Type 1 Diabetes Therapy
Noaro, G., Cappon, G., Sparacino, G., Favero, S. D., & Facchinetti, A. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176021 · Cited by 7
“The UVa/Padova T1D Simulator [8] was used to generate data of 100 subjects for training and testing the new models.”
MethodRobust Polytopic-LPV Body-Weight-Dependent Control of Blood Glucose in Type-1 Diabetes
Vafamand, N., Asemani, M. H., Mobayen, S., & Pujol, G. (2021) · IEEE Access · doi:10.1109/access.2021.3095216 · Cited by 7
“presented, such as UVA/Padova simulator [6], [7], Hovorka model [8], deep reinforcement learning model [9], 19-order Sorensen model [10], linear empirical dynamic model [11], Tolic model [12], and Bergman minimal model [13].”
MethodDynamic of Glucose Homeostasis in Virtual Patients: A Comparison between Different Behaviors
Alonso‐Bastida, A., Adam‐Medina, M., Posada, R., Salazar-Piña, D. A., Osorio-Gordillo, G. L., & Valdés, L. G. V. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19020716 · Cited by 6
“[14] based on mathematical models develop virtual patients (children, adolescents and adults) with type 1 diabetes mellitus (T1DM) for the development of applications in-silico related to glycemic control.”
BackgroundMPC-guided Imitation Learning of Bayesian Neural Network Policies for the Artificial Pancreas
Chen, H., Paoletti, N., Smolka, S. A., & Lin, S. (2021) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc45484.2021.9683240 · Cited by 12
“, a linearized version of the nonlinear model [2] in the Typezeror insulin delivery algorithm [5]) or favor simpler control algorithms (e.”
BackgroundMethodPacini, G., Åhrén, B., Göbl, C. S., & Tura, A. (2022) · Biomedicines · doi:10.3390/biomedicines10051060 · Cited by 6
A software interface for in silico testing of type 2 diabetes treatments
VISENTIN, R., Cobelli, C., & Man, C. D. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106973 · Cited by 7
Self-citationArtificial Pancreas Control for Diabetes using TD3 Deep Reinforcement Learning
Mackey, A., & Furey, E. (2022) · Irish Signals and Systems Conference · doi:10.1109/issc55427.2022.9826219 · Cited by 9
Furió-Novejarque, C., Sanz, R., Ritschel, T. K. S., Reenberg, A. T., Ranjan, A. G., Nørgaard, K., Díez, J.-L., Jørgensen, J. B., & Bondía, J. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.106605 · Cited by 7
Annuzzi, G., Bozzetto, L., Cataldo, A., Criscuolo, S., & Pesola, M. (2023) · ACTA IMEKO · doi:10.21014/actaimeko.v12i2.1453 · Cited by 8
“Among the ML techniques, the use of ANNs in prediction of blood glucose was investigated in several studies [28]–[35], using data from real T1D patients and virtual patients [36], as those obtained with UVA/Padova simulator [37].”
MethodGlucose Rate-of-Change and Insulin-on-Board Jointly Weighted Zone Model Predictive Control
Deshpande, S., Doyle, F. J., & Dassau, E. (2023) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2023.3291573 · Cited by 7
“where Ip and Il are insulin in the plasma and liver compartments, Isc1 and Isc2 are insulin mass in the two subcutaneous compartments from delivered insulin and described using a linear model [26], and m∗ and ka∗ are the virtual subjectspecific parameters.”
BackgroundMethodInfluentialMessori, M., Toffanin, C., Favero, S. D., Nicolao, G. D., Cobelli, C., & Magni, L. (2015) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2015.10.143 · Cited by 6
Self-citation
Metadata
- Authors
- Man, C. D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., & Cobelli, C.
- Affiliations
- University of Padua (IT)
- University of Virginia (US)
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2014-01
- Volume
- 8
- Issue
- 1
- Pages
- 26-34
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC4454102
- OpenAlex
- W2129995532
- Cited by
- 791
- References
- 25
- Citations by year
- 2026: 49 · 2025: 85 · 2024: 76 · 2023: 89 · 2022: 69 · 2021: 76 · 2020: 91 · 2019: 77 · 2018: 66 · 2017: 47 · 2016: 30 · 2015: 23 · 2014: 10
- FWCI
- 29.50
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, hypoglycemia, glucose kinetics, virtual patients, correction factors, in silico clinical trials, artificial pancreas, glucose sensor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-09, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-09 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.