Nonadjunctive Use of Continuous Glucose Monitoring for Diabetes Treatment Decisions
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
While self-monitoring of blood glucose (SMBG) is the current standard used by people with diabetes to manage glucose levels, recent improvements in accuracy of continuous glucose monitoring (CGM) technology are making it very likely that diabetes-related treatment decisions will soon be made based on CGM values alone. Nonadjunctive use of CGM will lead to a paradigm shift in how patients manage their glucose levels and will require substantial changes in how care providers educate their patients, monitor their progress, and provide feedback to help them manage their diabetes. The approval to use CGM nonadjunctively is also a critical step in the pathway toward FDA approval of an artificial pancreas system, which is further expected to transform diabetes care for people with type 1 diabetes. In this article, we discuss how nonadjunctive CGM is expected to soon replace routine SMBG and how this new usage scenario is expected to transform health outcomes and patient care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894 · cited 2×
“In the STAR-3 trial, comparing the use of multiple daily insulin injections (MDI) to sensor-augmented pump use, it was the increased frequency of sensor use, and not the use of pumps per se, that was associated with a greater reduction in A1C.(23) This association of reduced A1C with CGM use was confirmed by the SWITC…”
ResultThreshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652 · cited 1×
“The MiniMed 530G insulin pump system and the Medtronic Veo insulin pump can suspend insulin if the sensor falls below a threshold and the user doesn’t respond to an alarm.(29) Likewise the Medtronic 640G insulin pump system provides a predictive low glucose suspend if the patient is not responding to alarms and the sy…”
Methodthe SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494 · cited 1×
“The reduction in A1C largely dissipated when the CGM was blinded, and returned when the CGM data were again unblinded.(24) They found that when CGM systems were used in real-time, subjects demonstrated more intensive manipulation of insulin delivery, with an increase in the number of insulin boluses, more frequent use…”
MethodHome Use of an Artificial Beta Cell in Type 1 Diabetes
Thabit, H., Tauschmann, M., Allen, J. M., Leelarathna, L., Hartnell, S., Wilinska, M. E., Acerini, C. L., Dellweg, S., Benesch, C., Heinemann, L., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509351 · Cited by 450
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318
Delays in Minimally Invasive Continuous Glucose Monitoring Devices: A Review of Current Technology
Keenan, D. B., Mastrototaro, J. J., Voskanyan, G., & Steil, G. M. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300528 · Cited by 198 · cited 1×
“Delay can also be imparted due to smoothing of the signal during processing.(16) Interfering substances, particularly acetaminophen and to a lesser degree vitamin C, can artificially raise sensor values when they are oxidized at the indicating electrode.”
BackgroundClinical accuracy of a continuous glucose monitoring system with an advanced algorithm
Bailey, T. S., Chang, A., & Christiansen, M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814559746 · Cited by 168 · cited 1×
“2-22 mmol/L).(28) The Randomized Trial Comparing Continuous Glucose Monitoring With and Without Routine Blood Glucose Monitoring in Adults with Type 1 Diabetes (REPLACE-BG) is currently underway, evaluating the nonadjunctive use of the Dexcom system with the 505 algorithm in adults with type 1 diabetes (T1D) using ins…”
MethodJacobs, P. G., Resalat, N., El Youssef, J., Reddy, R., Branigan, D., Preiser, N., Condon, J., & Castle, J. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815609371 · Cited by 105
Self-citationHelton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500318 · Cited by 102
Cited by
Exercise management in type 1 diabetes: a consensus statement
Riddell, M. C., Gallen, I. W., Smart, C. E., Taplin, C. E., Adolfsson, P., Lumb, A. N., Kowalski, A., Rabasa-Lhoret, R., McCrimmon, R. J., Hume, C., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30014-1 · Cited by 903
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Continuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176
“It is becoming a common perception that CGM sensors are accurate enough to be used for therapeutic decisions [46] and the academic research is now focused on this new challenge, i.e., demonstrating both the safety and efficacy of CGM sensors for the nonadjunctive use.”
BackgroundContinuous glucose monitoring: Current use in diabetes management and possible future applications
Vettoretti, M., Cappon, G., Acciaroli, G., Facchinetti, A., & Sparacino, G. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818774078 · Cited by 96
“Moreover, some CGM devices received regulatory approval for nonadjunctive use; that is, the patient can make treatment decisions without using confirmatory self-monitoring of blood glucose (SMBG) measurements obtained by finger stick, except in certain situations (eg, rapidly changing glucose levels or CGM readings th…”
BackgroundWearable physiological systems and technologies for metabolic monitoring
Gao, W., Brooks, G. A., & Klonoff, D. C. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00407.2017 · Cited by 91
Metadata
- Authors
- Castle, J. R., & Jacobs, P. G.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2016-07-09
- Volume
- 10
- Issue
- 5
- Pages
- 1169-1173
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2342075066
- Cited by
- 56
- References
- 11
- FWCI
- 9.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.