Continuous Glucose Monitoring (CGM) Adherence in Youth With Type 1 Diabetes: Associations With Biomedical and Psychosocial Variables
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Continuous glucose monitoring (CGM) remains underutilized in youth with type 1 diabetes (T1D). There is a need to investigate factors associated with CGM use. METHOD: In 61 T1D youth, CGM use was ascertained by downloads reflecting the 4-week periods preceding 3- and 6-month study visits. Demographic and clinical data were obtained from chart review and interview. Youth and parents completed validated psychosocial surveys at baseline and 6 months. RESULTS: Youth (52% male, 93% Caucasian, 80% pump treated) were 12.7 ± 2.9 years old, with T1D for 6.3 ± 3.8 years; mean A1c was 7.9 ± 0.9%. Mean CGM use was 4.1 ± 2.1 days/week (median = 4.8) at 3 months and 3.4 ± 2.3 days/week (median = 3.9) at 6 months. At 3 and 6 months, 15% and 20% of youth, respectively, had stopped using CGM. At 6 months, youth using CGM 6-7 days/week had more frequent BG monitoring ( P = .05), less insulin omission ( P = .02), and greater probability of A1c < 7.5% ( P = .01) than youth using CGM less often. Youth using CGM 6-7 days/week consistently over the 6 months demonstrated lower A1c at 3 months compared to baseline ( P = .03) and the improvement was sustained at 6 months ( P = .5, 3 vs 6 months); youth using CGM less often had no significant A1c change. Baseline BG monitoring ≥8 times/day or A1c within target (<7.5%) predicted greater CGM use (6-7 days/week) at 6 months (OR = 4.6, P = .02). There was no deterioration of psychosocial functioning with CGM use. CONCLUSIONS: Consistent and durable CGM use in youth with T1D is associated with treatment adherence and improved glycemic control without increasing psychosocial distress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Varni, J. W., Seid, M., & Kurtin, P. S. (2001) · Medical Care · doi:10.1097/00005650-200108000-00006 · Cited by 5,131
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254 · cited 7×
“Indeed, according to recent data from the Type 1 Diabetes Exchange Clinic Registry, a minority of patients in the registry were using CGM, and only 5 to 13% of pediatric patients were using CGM.(7) Several barriers may affect consistent CGM use in pediatrics as the CGM places multiple demands on the patient, the famil…”
BackgroundMethodInfluentialPickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541 · cited 2×
“CGM has been shown to improve outcomes, particularly when used on a near-daily basis.(1,3,4) However, data from previous studies have shown that only a small proportion of patients with T1D use CGM consistently, especially in the pediatric age group.”
BackgroundMethodThe effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
McKnight, J. A., Wild, S. H., Lamb, M. J. E., Cooper, M. N., Jones, T. W., Davis, E. A., Hofer, S., Fritsch, M., Schober, E., Svensson, J., et al. (2015) · Diabetic Medicine · doi:10.1111/dme.12676 · Cited by 343 · cited 6×
“In addition, the study sample was unique in many aspects due to the large proportion of participants treated with insulin pump therapy, the high frequency of BG monitoring at baseline, and the relatively low mean A1c compared to other samples of youth with T1D,7 and, therefore, the results may not be generalizable to…”
BackgroundInfluentialReal-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318 · cited 8×
“At 3 and 6 months, 15% and 20% of youth, respectively, had stopped using CGM.”
BackgroundResultInfluentialEffectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Mauras, N., Beck, R., Xing, D., Ruedy, K., Buckingham, B., Tansey, M., White, N. H., Weinzimer, S. A., Tamborlane, W., Kollman, C., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1746 · Cited by 204
Markowitz, J. T., Volkening, L. K., Butler, D. A., Antisdel‐Lomaglio, J., Anderson, B. J., & Laffel, L. M. B. (2012) · Diabetic Medicine · doi:10.1111/j.1464-5491.2011.03434.x · Cited by 122
Self-citation
Cited by
Missed and Mistimed Insulin Doses in People with Diabetes: A Systematic Literature Review
Robinson, S., Newson, R. S., Liao, B., Kennedy-Martin, T., & Battelino, T. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0164 · Cited by 73
Parental depression and diabetes-specific distress after the onset of type 1 diabetes in children
Noser, A. E., Dai, H., Marker, A. M., Raymond, J. K., Majidi, S., Clements, M. A., Stanek, K. R., & Patton, S. R. (2019) · Health Psychology · doi:10.1037/hea0000699 · Cited by 57
Boucher, S. E., Gray, A. R., Wiltshire, E. J., de Bock, M. I., Galland, B. C., Tomlinson, P. A., Rayns, J. A., MacKenzie, K. E., Chan, H., Rose, S., et al. (2020) · Diabetes Care · doi:10.2337/dc20-0613 · Cited by 51
Barriers to continuous glucose monitoring in people with type 1 diabetes: clinician perspectives
Lanning, M. S., Tanenbaum, M. L., Wong, J. J., & Hood, K. K. (2020) · Diabetes Spectrum · doi:10.2337/ds19-0039 · Cited by 40
Distinct patterns of daily glucose variability by pubertal status in youth with type 1 diabetes
Zhu, J., Volkening, L. K., & Laffel, L. M. (2020) · Diabetes Care · doi:10.2337/dc19-0083 · Cited by 30
Self-citation
Metadata
- Authors
- Giani, E., Snelgrove, R., Volkening, L. K., & Laffel, L. M.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2016-11
- Volume
- 11
- Issue
- 3
- Pages
- 476-483
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2547042582
- Cited by
- 71
- References
- 11
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Glucose Monitoring (CGM) Adherence in Youth With Type 1 Diabetes: Associations With Biomedical and Psychosocial Variables. https://app.cochat.ai/papers/10.1177/1932296816676280
- The paper
- Giani, E., Snelgrove, R., Volkening, L. K., & Laffel, L. M. (2017). Continuous Glucose Monitoring (CGM) Adherence in Youth With Type 1 Diabetes: Associations With Biomedical and Psychosocial Variables. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296816676280
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.